Engine parameters
The Audi A7 has 489 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2020. Supported for 2021.
Adaptive mode A7_ADAPTIVE_MODE
- Request
22 10 11 - Service 22
DID 1011 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Air conditioning compressor pressure A7_AC_COMP_P
- Request
22 10 17 - Service 22
DID 1017 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2019 to 2026.
Air conditioning compressor pressure, linear raw value A7_AC_COMP_P_LINEAR_RAW
- Request
22 15 C7 - Service 22
DID 15C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070
- Unit
- Raw value
In testing for 2019 to 2026.
Air conditioning compressor refrigerant pressure A7_AC_COMP_REFRIGERANT_P
- Request
22 10 48 - Service 22
DID 1048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2019 to 2026.
Air conditioning compressor torque A7_AC_COMP_TQ
- Request
22 10 1A - Service 22
DID 101A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Air conditioning compressor torque request A7_AC_COMP_TQ_REQ
- Request
22 10 23 - Service 22
DID 1023 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Air conditioning refrigerant pressure A7_AC_REFRIGERANT_P
- Request
22 41 2A - Service 22
DID 412A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534
- Unit
- Raw value
In testing for 2019 to 2026.
Air filling A7_AIR_FILLING
- Request
22 12 1C - Service 22
DID 121C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 11719 ÷ 500000)- Range
- 0 to 1536 %
- Unit
- %
In testing for 2019 to 2026.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2012. Supported for 2016.
Air leakage A7_AIR_LEAKAGE
- Request
22 11 B8 - Service 22
DID 11B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2019 to 2026.
Air mass A7_AIR_MASS
- Request
22 13 CD - Service 22
DID 13CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047
- Unit
- Raw value
In testing for 2010 to 2018.
Air mass meter 1 A7_MQB_AIR_MASS_1Confirmed
- Request
22 10 24 - Service 22
DID 1024 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x01B5 = 437 → (437 × 1000 ÷ 10000) = 43.7
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Air mass, specified value A7_AIR_MASS_SPEC
- Request
22 10 4C - Service 22
DID 104C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2010 to 2018.
Ambient air temperature, v1 A7_AAT_V1Confirmed
- Request
22 14 F8 - Service 22
DID 14F8 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0ACE = 2766 → (2766 × 0.18 − 460) = 37.88 °F
- Formula
(val × 0.18 − 460)- Range
- -460 to 11336.3 °F
- Unit
- °F
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Ambient temperature A7_AAT_7E0
- Request
22 10 00 - Service 22
DID 1000 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2010 to 2018.
Ambient temperature A7_AAT_7E0_2
- Request
22 11 23 - Service 22
DID 1123 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Aux. hydraulic pump internal temperature A7_AUX_HYDRAULIC_PMP_T
- Request
22 51 A6 - Service 22
DID 51A6 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Aux. hydraulic pump, current A7_AUX_HYDRAULIC_PMP
- Request
22 4E 76 - Service 22
DID 4E76 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 A
- Unit
- A
In testing for 2019 to 2026.
Barometric pressure A7_BAROMETRIC_P
- Request
22 15 09 - Service 22
DID 1509 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 kPa
- Unit
- kPa
In testing for 2019 to 2026.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2020. Supported for 2012, 2016, 2021.
Boost pressure commanded A7_PQ35_BOOST_P_CMDConfirmed
- Request
22 11 49 - Service 22
DID 1149 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2020.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2020.
Boost pressure, actual A7_BOOST_P_ACT
- Request
22 11 F0 - Service 22
DID 11F0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2019 to 2026.
Boost regulator feedback A7_BOOST_REGULATOR_FEEDBACKConfirmed
- Request
22 11 CC - Service 22
DID 11CC - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x184C = 6220 → (6220 ÷ 100) = 62.2 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Break pressure A7_BREAK_P
- Request
22 2B 21 - Service 22
DID 2B21 - Module
713 → 77D - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 152999 ÷ 10000000 − 42.503)- Range
- -543 to 458 bar
- Unit
- bar
In testing for 2019 to 2026.
Bypass valve high pressure turbine inlet, activation A7_BYPASS_VLV_HIGH_P
- Request
22 39 FF - Service 22
DID 39FF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2019 to 2026.
Bypass valve high pressure turbine inlet, actual value A7_BYPASS_VLV_HIGH_P_ACT
- Request
22 39 FC - Service 22
DID 39FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 25 ÷ 2048)- Range
- -400 to 399 %
- Unit
- %
In testing for 2019 to 2026.
Bypass valve high pressure turbine inlet, offset closed A7_BYPASS_VLV_HIGH_P_TURBINE
- Request
22 39 FD - Service 22
DID 39FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.012207)- Range
- -399 to 399 %
- Unit
- %
In testing for 2019 to 2026.
Bypass valve high pressure turbine inlet, offset open A7_BYPASS_VLV_HIGH_P_TURBINE_INLET
- Request
22 39 FE - Service 22
DID 39FE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.012207)- Range
- -399 to 399 %
- Unit
- %
In testing for 2019 to 2026.
Bypass valve high pressure turbine inlet, target value A7_BYPASS_VLV_HIGH_P_TGT
- Request
22 39 FB - Service 22
DID 39FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 25 ÷ 2048)- Range
- -400 to 399 %
- Unit
- %
In testing for 2019 to 2026.
Bze_q_elad A7_BZE_Q_ELAD
- Request
22 12 3A - Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2019 to 2026.
Bze_q_lad A7_BZE_Q_LAD
- Request
22 12 3A - Service 22
DID 123A - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2019 to 2026.
Cabin temperature A7_C7_CABIN_TConfirmed
- Request
22 26 13 - Service 22
DID 2613 - Module
746 → 7B0 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x12D5 = 4821 → (4821 ÷ 256) = 18.832031 °C
- Formula
(val ÷ 256)- Range
- -128 to 127.99 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2018. Not supported for 2020.
Cabin temperature A7_CABIN_T
- Request
22 26 13 - Service 22
DID 2613 - Module
746 → 7B0 - Every
5 s
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 100 °C
- Unit
- °C
Supported for 2011 to 2012. Not supported for 2020.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012, 2020. Supported for 2016, 2021.
Camshaft adaptation exhaust bank 1, phase position A7_CAM_ADPT_EXH_BANK_1
- Request
22 11 28 - Service 22
DID 1128 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2010 to 2018.
Camshaft adaptation intake bank 1, phase position A7_CAM_ADPT_INT_BANK_1
- Request
22 11 25 - Service 22
DID 1125 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2010 to 2018.
Camshaft adaptation, counter due to knock A7_CAM_ADPT_CNT_KNOCK
- Request
22 52 3B - Service 22
DID 523B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Camshaft adaptation, intake deviation A7_CAM_ADPT_INT_DEV
- Request
22 4F F5 - Service 22
DID 4FF5 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2019 to 2026.
Camshaft adjustment, exhaust bank 1, actual value A7_CAM_ADJ_EXH_BANK_1_ACT
- Request
22 13 6C - Service 22
DID 136C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °
- Unit
- °
In testing for 2019 to 2026.
Camshaft adjustment, exhaust bank 1, specified value A7_CAM_ADJ_EXH_BANK_1_SPEC
- Request
22 13 71 - Service 22
DID 1371 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262 to 262 °
- Unit
- °
In testing for 2019 to 2026.
Camshaft adjustment, exhaust bank 2, actual value A7_CAM_ADJ_EXH_BANK_2_ACT
- Request
22 13 6D - Service 22
DID 136D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °
- Unit
- °
In testing for 2019 to 2026.
Camshaft adjustment, exhaust bank 2, specified value A7_CAM_ADJ_EXH_BANK_2_SPEC
- Request
22 13 72 - Service 22
DID 1372 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262 to 262 °
- Unit
- °
In testing for 2019 to 2026.
Camshaft adjustment, intake bank 1, actual value A7_CAM_ADJ_INT_BANK_1_ACT
- Request
22 13 6E - Service 22
DID 136E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °
- Unit
- °
In testing for 2019 to 2026.
Camshaft adjustment, intake bank 1, specified value A7_CAM_ADJ_INT_BANK_1_SPEC
- Request
22 13 73 - Service 22
DID 1373 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 125)- Range
- -262 to 262 °
- Unit
- °
In testing for 2019 to 2026.
Camshaft end position A7_PQ35_CAMS_ENDConfirmed
- Request
22 13 41 - Service 22
DID 1341 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x00C3 = 195 → (195 ÷ 5) = 39 °
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 °
- Unit
- °
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Camshaft position, deviation from the base position A7_CAM_POS_DEV_BASE_POS
- Request
22 13 85 - Service 22
DID 1385 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2019 to 2026.
Camshaft start position A7_PQ35_CAMS_STARTConfirmed
- Request
22 10 07 - Service 22
DID 1007 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x20CF = 8399 → (8399 ÷ 5) = 1,679.8 °
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Cat. temperature, bank 1 A7_CAT_T_BANK_1
- Request
22 12 98 - Service 22
DID 1298 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 273.15)- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2010 to 2018.
Cat. temperature, bank 2 A7_CAT_T_BANK_2
- Request
22 12 99 - Service 22
DID 1299 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 273.15)- Range
- -273 to 3822 °C
- Unit
- °C
In testing for 2010 to 2018.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2020. Supported for 2016, 2021.
Catalyst temperature, calculated A7_CAT_T_CALC
- Request
22 15 15 - Service 22
DID 1515 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 − 50)- Range
- -50 to 1225 °C
- Unit
- °C
In testing for 2019 to 2026.
Charge air cooler downstream air pressure A7_AIR_P_CAC_DS
- Request
22 10 56 - Service 22
DID 1056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2019 to 2026.
Clutch #1 maximum temperature A7_PQ35_CLUTCH_1_MAXIMUM_T
- Request
22 11 18 - Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2010, 2013 to 2026
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2010, 2013 to 2019, 2021 to 2026. Supported for 2011 to 2012. Not supported for 2020.
Clutch #2 maximum temperature A7_PQ35_CLUTCH_2_MAXIMUM_T
- Request
22 11 18 - Service 22
DID 1118 - Module
7E1 → 7E9 - Every
3600 s - Testing for 2010, 2013 to 2026
Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2010, 2013 to 2019, 2021 to 2026. Supported for 2011 to 2012. Not supported for 2020.
Clutch 0 temperature calculated A7_C7_CLUTCH_0_T_CALCULATEDConfirmed
- Request
22 12 0F - Service 22
DID 120F - Module
7E1 → 7E9 - Every
5 s - Testing for 2010, 2013 to 2017
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x02BC = 700 → (700 ÷ 10) = 70 °C
- Formula
(val ÷ 10)- Range
- -40 to 600 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2017.
Clutch 0 temperature calculated A7_MQB_DL382_CLUTCH_0_T_CALCULATEDConfirmed
- Request
22 12 0F - Service 22
DID 120F - Module
7E1 → 7E9 - Every
5 s - Testing for 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0026 = 38 → 38 °C
- Formula
val- Range
- -40 to 600 °C
- Unit
- °C
Confirmed for 2020. In testing for 2021 to 2026.
Clutch 1 temperature A7_PQ35_CLUTCH_1_TConfirmed
- Request
22 10 2B - Service 22
DID 102B - Module
7E1 → 7E9 - Every
5 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 °C
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Clutch 2 temperature A7_PQ35_CLUTCH_2_TConfirmed
- Request
22 10 2C - Service 22
DID 102C - Module
7E1 → 7E9 - Every
5 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 °C
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Clutch temperature calculated A7_MQB_DL382_CLUTCH_T_CALCULATEDConfirmed
- Request
22 18 E3 - Service 22
DID 18E3 - Module
7E1 → 7E9 - Every
5 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0045 = 69 → 69 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2020.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2020.
Commanded crankshaft torque A7_CMD_CRANK_TQ
- Request
22 11 E0 - Service 22
DID 11E0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2020. Supported for 2021.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. Supported for 2021.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. Supported for 2012, 2016.
Compression test cylinder 1 A7_PQ35_COMPRESSION_TEST_CYL_1Confirmed
- Request
22 11 29 - Service 22
DID 1129 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 2) = 0 rpm
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Compression test cylinder 2 A7_PQ35_COMP_TEST_CYL_2
- Request
22 11 2A - Service 22
DID 112A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 rpm
- Unit
- rpm
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Control module temperature A7_CTRL_MODULE_T
- Request
22 03 01 - Service 22
DID 0301 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Control module temperature A7_ECU_TEMP
- Request
22 02 8D - Service 22
DID 028D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
Not supported for 2011 to 2012, 2016.
Control module temperature A7_ECU_TEMP_KConfirmed
- Request
22 02 8D - Service 22
DID 028D - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0B79 = 2937 → (2937 ÷ 10 − 273.1) = 20.6 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2020. In testing for 2019, 2021 to 2026.
Converter loss torque A7_MQB_TCM_CONVERTER_LOSS_TORQUEConfirmed
- Request
22 10 10 - Service 22
DID 1010 - Module
7E1 → 7E9 - Every
250 ms - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0046 = 70 → (70 ÷ 20) = 3.5 N·m
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Coolant at engine start A7_CLT_ENG_START
- Request
22 12 91 - Service 22
DID 1291 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Coolant circulation pump, control A7_CLT_CIRCULATION_PMP
- Request
22 16 7E - Service 22
DID 167E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2019 to 2026.
Coolant fan 1 activation, $1117 A7_CLT_FAN_1_ACTIVATION_1117
- Request
22 11 17 - Service 22
DID 1117 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2019 to 2026.
Coolant fan 1 duty cycle A7_PQ35_COOL_FAN_1_DUTYConfirmed
- Request
22 11 16 - Service 22
DID 1116 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Coolant fan 2 duty cycle A7_PQ35_COOL_FAN_2_DUTYConfirmed
- Request
22 11 14 - Service 22
DID 1114 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x03E8 = 1000 → (1000 ÷ 100) = 10 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Coolant fan activation, actual value A7_CLT_FAN_ACTIVATION_ACT
- Request
22 26 06 - Service 22
DID 2606 - Module
70E → 778 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2019 to 2026.
Coolant fan activation, specified value A7_CLT_FAN_ACTIVATION_SPEC
- Request
22 26 07 - Service 22
DID 2607 - Module
70E → 778 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2019 to 2026.
Coolant fan, requested by A/C A7_CLT_FAN_REQ_AC
- Request
22 10 18 - Service 22
DID 1018 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 1000000)- Range
- -399 to 399 %
- Unit
- %
In testing for 2019 to 2026.
Coolant temperature at engine outlet, calculated A7_ECT_ENG_OUTLET_CALC
- Request
22 10 64 - Service 22
DID 1064 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Coolant temperature at radiator outlet A7_COOLANT_TConfirmed
- Request
22 11 35 - Service 22
DID 1135 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0EC3 = 3779 → (3779 ÷ 10 − 273.1) = 104.8 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Coolant temperature at radiator outlet v.1 A7_ECT_RADIATOR_OUTLET_V_1
- Request
22 15 CD - Service 22
DID 15CD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2019 to 2026.
Cooling fan 1 A7_COOLING_FAN_1
- Request
22 11 30 - Service 22
DID 1130 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2019 to 2026.
Cooling fan 2 A7_COOLING_FAN_2
- Request
22 11 2E - Service 22
DID 112E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2019 to 2026.
Correction factor of oil temperature for engine protection A7_CORR_FACTOR_OIL_T
- Request
22 3F 4F - Service 22
DID 3F4F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 100000000)- Range
- 0 to 7.99
- Unit
- Number
In testing for 2019 to 2026.
Current N215 pressure control valve 1 A7_CURRENT_N215_P_CTRL_1
- Request
22 10 24 - Service 22
DID 1024 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2019 to 2026.
Current N216 pressure control valve 2 A7_CURRENT_N216_P_CTRL_2
- Request
22 10 26 - Service 22
DID 1026 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2019 to 2026.
Current N217 pressure control valve 3 A7_CURRENT_N217_P_CTRL_3
- Request
22 10 28 - Service 22
DID 1028 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2019 to 2026.
Current N218 pressure control valve 4 A7_CURRENT_N218_P_CTRL_4
- Request
22 10 25 - Service 22
DID 1025 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2019 to 2026.
Current N233 pressure control valve 5 A7_CURRENT_N233_P_CTRL_5
- Request
22 10 27 - Service 22
DID 1027 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2019 to 2026.
Current N443 pressure control valve 7 main pressure A7_CURRENT_N443_P_CTRL_7_P
- Request
22 10 2A - Service 22
DID 102A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2019 to 2026.
Current solenoid A7_CURRENT_SOLENOID
- Request
22 10 37 - Service 22
DID 1037 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 mA
- Unit
- mA
In testing for 2019 to 2026.
Current type of driver counter A7_CURRENT_TYPE_DRIVER
- Request
22 10 13 - Service 22
DID 1013 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Cylinder head temperature, actual A7_CYL_HEAD_T_ACT
- Request
22 10 65 - Service 22
DID 1065 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Desired torque filtered A7_DES_TQ_FILTERED
- Request
22 10 64 - Service 22
DID 1064 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Desired torque raw A7_DES_TQ_RAW
- Request
22 10 61 - Service 22
DID 1061 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Diesel particulate filter air pressure sensor, raw A7_MQB_DPF_AIR_P_SENSOR_RAW_VALUEConfirmed
- Request
22 16 2F - Service 22
DID 162F - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0007 = 7 → 7
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Diesel particulate filter ash load limit A7_DPF_ASH_LOAD_LIM
- Request
22 40 6B - Service 22
DID 406B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Diesel particulate filter counter for regeneration time A7_DPF_CNT_REGEN_TIME
- Request
22 39 F9 - Service 22
DID 39F9 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100)- Range
- 0 to 42949672 s
- Unit
- s
In testing for 2019 to 2026.
Diesel particulate filter differential pressure A7_DPF_DIFF_P
- Request
22 20 84 - Service 22
DID 2084 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2019 to 2026.
Diesel particulate filter differential pressure offset A7_PQ35_DPF_DIFF_P_OFFSETConfirmed
- Request
22 10 F1 - Service 22
DID 10F1 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0002 = 2 → 2
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Diesel particulate filter differential pressure raw value, bank 1 A7_DPF_DIFF_P_RAW_BANK_1
- Request
22 16 6B - Service 22
DID 166B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2018.
Diesel particulate filter differential pressure raw value, bank 2 A7_DPF_DIFF_P_RAW_BANK_2
- Request
22 16 6C - Service 22
DID 166C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2018.
Diesel particulate filter differential pressure variant 2 A7_PQ35_DPF_DIFF_P_2Confirmed
- Request
22 10 F3 - Service 22
DID 10F3 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0007 = 7 → 7
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Diesel particulate filter differential pressure, dynamic offset A7_MQB_DPF_DIFF_P_DYNAMIC_OFFSETConfirmed
- Request
22 15 B8 - Service 22
DID 15B8 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Diesel particulate filter exhaust gas flow volume A7_MQB_DPF_EXH_VOLConfirmed
- Request
22 11 E6 - Service 22
DID 11E6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 1000 ÷ 10000) = 0
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Number
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Diesel particulate filter field regeneration, cancel conditions A7_DPF_FIELD_REGEN
- Request
22 29 F7 - Service 22
DID 29F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter field regeneration, lock status A7_DPF_FIELD_REGEN_LOCK
- Request
22 20 88 - Service 22
DID 2088 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter field regeneration, request status A7_DPF_FIELD_REGEN_REQ
- Request
22 20 87 - Service 22
DID 2087 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter inlet temperature A7_PQ35_DPF_IN_TConfirmed
- Request
22 11 B2 - Service 22
DID 11B2 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x1166 = 4454 → (4454 ÷ 10 − 273.1) = 172.3 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Diesel particulate filter offset for differential pressure A7_DPF_OFFSET_DIFF_P
- Request
22 20 85 - Service 22
DID 2085 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2019 to 2026.
Diesel particulate filter oil ash mass A7_DPF_OIL_ASH_MASS
- Request
22 40 6C - Service 22
DID 406C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729
- Unit
- Raw value
In testing for 2019 to 2026.
Diesel particulate filter oil ash volume A7_DPF_OIL_ASH_VOLUME
- Request
22 20 8B - Service 22
DID 208B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 L
- Unit
- L
In testing for 2019 to 2026.
Diesel particulate filter oil ash volume, bank 1 A7_DPF_OIL_ASH_VOLUME_1
- Request
22 14 B9 - Service 22
DID 14B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 L
- Unit
- L
In testing for 2010 to 2018.
Diesel particulate filter oil ash volume, bank 2 A7_DPF_OIL_ASH_VOLUME_2
- Request
22 14 5F - Service 22
DID 145F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 L
- Unit
- L
In testing for 2010 to 2018.
Diesel particulate filter outlet temperature A7_PQ35_DPF_OUT_TConfirmed
- Request
22 10 F9 - Service 22
DID 10F9 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x105D = 4189 → (4189 ÷ 10 − 273.1) = 145.8 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Diesel particulate filter regeneration cancel conditions A7_DPF_REGEN_CANCEL
- Request
22 13 7C - Service 22
DID 137C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter service regeneration, duration with heat-up A7_DPF_SERVICE_REGEN
- Request
22 11 C3 - Service 22
DID 11C3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100)- Range
- 0 to 42949672 s
- Unit
- s
In testing for 2019 to 2026.
Diesel particulate filter soot mass calculated, bank 1 A7_DPF_SOOT_MASS_CALC_1
- Request
22 14 BA - Service 22
DID 14BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2018.
Diesel particulate filter soot mass calculated, bank 2 A7_DPF_SOOT_MASS_CALC_2
- Request
22 14 5E - Service 22
DID 145E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2018.
Diesel particulate filter soot mass measured, bank 1 A7_DPF_SOOT_MASS_MEAS_1
- Request
22 14 BB - Service 22
DID 14BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2018.
Diesel particulate filter soot mass measured, bank 2 A7_DPF_SOOT_MASS_MEAS_2
- Request
22 14 5D - Service 22
DID 145D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2018.
Diesel particulate filter soot measured A7_DPF_SOOT_MEAS
- Request
22 20 8C - Service 22
DID 208C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Diesel particulate filter soot volume in exhaust, mg/m^3 A7_DPF_SOOT_VOLUME_EXH_M_3
- Request
22 18 C0 - Service 22
DID 18C0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter statistics current avg. temperature after DPF A7_DPF_STATISTICS_T
- Request
22 15 7C - Service 22
DID 157C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Diesel particulate filter statistics current avg. temperature after part.filter A7_DPF_STATISTICS_CURRENT_AVG_T
- Request
22 40 01 - Service 22
DID 4001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2019 to 2026.
Diesel particulate filter statistics current calculated charging rate, g/km A7_DPF_STATISTICS_CURRENT_G
- Request
22 40 07 - Service 22
DID 4007 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 100000000)- Range
- -3.99 to 3.99
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter statistics current measured charging rate, g/km A7_DPF_STATISTICS_G
- Request
22 40 05 - Service 22
DID 4005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 100000000)- Range
- -3.99 to 3.99
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter surface temperature A7_DPF_SFC_TConfirmed
- Request
22 10 44 - Service 22
DID 1044 - Module
7E0 → 7E8 - Every
300 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x118A = 4490 → (4490 ÷ 10 − 273.1) = 175.9 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Diesel particulate filter time since last regeneration A7_DPF_TIME_SINCE_REGEN
- Request
22 20 89 - Service 22
DID 2089 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 1193046 h
- Unit
- h
In testing for 2019 to 2026.
Diesel particulate filter time since last regeneration, h, bank 1 A7_DPF_TIME_SINCE_REGEN_H_1
- Request
22 14 34 - Service 22
DID 1434 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 1193046
- Unit
- Raw value
In testing for 2010 to 2018.
Diesel particulate filter time since last regeneration, h, bank 2 A7_DPF_TIME_SINCE_REGEN_H_2
- Request
22 14 64 - Service 22
DID 1464 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 1193046
- Unit
- Raw value
In testing for 2010 to 2018.
Differential pressure A7_PQ35_DIFF_PConfirmed
- Request
22 14 F5 - Service 22
DID 14F5 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0005 = 5 → 5
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Driving mode sensor, hall sensor a A7_DRIVING_MODE_SENS
- Request
22 21 0D - Service 22
DID 210D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Driving position A7_DRIVING_POS
- Request
22 21 0E - Service 22
DID 210E - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Driving resistance index A7_DRIVING_RES_INDEX
- Request
22 21 08 - Service 22
DID 2108 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127
- Unit
- Number
In testing for 2019 to 2026.
Dynamic torque limitation A7_DYNAMIC_TQ_LIM
- Request
22 10 67 - Service 22
DID 1067 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Ea888b boost pressure control, adaptation value 0 A7_EA888B_BOOST_P_CTRL_0
- Request
22 11 FF - Service 22
DID 11FF - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359 to 356
- Unit
- Raw value
In testing for 2019 to 2026.
Ea888b boost pressure control, adaptation value 1 A7_EA888B_BOOST_P_CTRL_1
- Request
22 12 00 - Service 22
DID 1200 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359 to 356
- Unit
- Raw value
In testing for 2019 to 2026.
Ea888b boost pressure control, adaptation value 2 A7_EA888B_BOOST_P_CTRL_2
- Request
22 12 01 - Service 22
DID 1201 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359 to 356
- Unit
- Raw value
In testing for 2019 to 2026.
Ea888b boost pressure control, adaptation value 3 A7_EA888B_BOOST_P_CTRL_3
- Request
22 12 02 - Service 22
DID 1202 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 281 ÷ 100)- Range
- -359 to 356
- Unit
- Raw value
In testing for 2019 to 2026.
Ea888b boost pressure regulator, commanded A7_EA888B_BOOST_P_CMD
- Request
22 11 A3 - Service 22
DID 11A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Early ignition counter, total, cylinder 1 A7_EARLY_IGN_CNT_TOT_1
- Request
22 17 15 - Service 22
DID 1715 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Early ignition counter, total, cylinder 2 A7_EARLY_IGN_CNT_TOT_2
- Request
22 17 18 - Service 22
DID 1718 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Early ignition counter, total, cylinder 3 A7_EARLY_IGN_CNT_TOT_3
- Request
22 17 16 - Service 22
DID 1716 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Early ignition counter, total, cylinder 4 A7_EARLY_IGN_CNT_TOT_4
- Request
22 17 17 - Service 22
DID 1717 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Early ignition counter:, cylinder 1 A7_EARLY_IGN_CNT_CYL_1
- Request
22 17 22 - Service 22
DID 1722 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Early ignition counter:, cylinder 2 A7_EARLY_IGN_CNT_CYL_2
- Request
22 17 25 - Service 22
DID 1725 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Early ignition counter:, cylinder 3 A7_EARLY_IGN_CNT_CYL_3
- Request
22 17 23 - Service 22
DID 1723 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Early ignition counter:, cylinder 4 A7_EARLY_IGN_CNT_CYL_4
- Request
22 17 24 - Service 22
DID 1724 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Effective injection duration A7_EFFECTIVE_INJ_DUR
- Request
22 15 E7 - Service 22
DID 15E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2019 to 2026.
EGT after catalyst, model bank 1 A7_EGT_AFTER_CAT_MODEL_1
- Request
22 2A E9 - Service 22
DID 2AE9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.023438 − 273.15)- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2019 to 2026.
EGT after catalyst, model bank b A7_EGT_AFTER_CAT_MODEL_B
- Request
22 2A E3 - Service 22
DID 2AE3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.023438 − 273.15)- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2019 to 2026.
EGT after catalyst, modeled A7_EGT_AFTER_CAT
- Request
22 12 72 - Service 22
DID 1272 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
EGT at lambda sensor 1, modeled A7_EGT_LAMBDA_SENS_1
- Request
22 13 9C - Service 22
DID 139C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Electric motor 1 rpm A7_EM_RPM_1Confirmed
- Request
22 11 51 - Service 22
DID 1151 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2010 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -100 to 100 rpm
- Unit
- rpm
Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.
Electric motor 1 torque A7_EM_TORQ_1Confirmed
- Request
22 11 53 - Service 22
DID 1153 - Module
7E0 → 7E8 - Every
10.25 s - Testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x5781 = 22401 → (22401 ÷ 32) = 700.03125 N·m
- Formula
(val ÷ 32)- Range
- -1000 to 1000 N·m
- Unit
- N·m
Confirmed for 2011 to 2012, 2016, 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026.
Electric motor 2 rpm A7_EM_RPM_2Confirmed
- Request
22 11 52 - Service 22
DID 1152 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFFFF = -1 → (-1 ÷ 2) = -0.5 rpm
- Formula
(val ÷ 2)- Range
- -100 to 100 rpm
- Unit
- rpm
Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.
Electric motor 2 torque A7_EM_TORQ_2Confirmed
- Request
22 11 54 - Service 22
DID 1154 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x8888 = -30584 → (-30584 ÷ 32) = -955.75 N·m
- Formula
(val ÷ 32)- Range
- -1000 to 1000 N·m
- Unit
- N·m
Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.
Energy balance of last driving cycle A7_ENERGY_BALANCE_LAST
- Request
22 2A 15 - Service 22
DID 2A15 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 Ah
- Unit
- Ah
In testing for 2019 to 2026.
Engine compartment temperature raw value A7_ENG_COMPARTMENT_T
- Request
22 46 B1 - Service 22
DID 46B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2019 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2012, 2020. Supported for 2016, 2021.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2020.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2020.
Engine oil level A7_PQ35_OIL_LVLConfirmed
- Request
22 11 BC - Service 22
DID 11BC - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x25AD = 9645 → (9645 ÷ 250) = 38.58 mm
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 mm
- Unit
- mm
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Engine oil level current value A7_ENG_OIL_LEVEL
- Request
22 58 D1 - Service 22
DID 58D1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2019 to 2026.
Engine oil temperature A7_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 10 E6 - Service 22
DID 10E6 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 60)- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2010 to 2018.
Engine oil temperature A7_EOT_7E0
Pelican can show this parameter as the engine oil temperature.
- Request
22 20 2F - Service 22
DID 202F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2019 to 2026.
Engine oil temperature A7_EOT_V2Confirmed
Scaling is unknown, needs further validation.
- Request
22 11 BE - Service 22
DID 11BE - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2011 to 2012, 2016, 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026.
Engine oil temperature sensor 2 A7_EOT_SENS_2
Pelican can show this parameter as the engine oil temperature.
- Request
22 40 D5 - Service 22
DID 40D5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2019 to 2026.
Engine oil temperature, pulse sensor A7_EOT_PULS
- Request
22 17 9E - Service 22
DID 179E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Engine outlet coolant temperature calculated A7_ENG_OUTLET_ECT_CALC
- Request
22 10 63 - Service 22
DID 1063 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Engine protection, torque limit A7_ENG_PROTECTION_TQ
- Request
22 2B C0 - Service 22
DID 2BC0 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2020. Supported for 2012, 2016, 2021.
Engine start quantity A7_PQ35_ENG_START_QTYConfirmed
- Request
22 10 69 - Service 22
DID 1069 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x070C = 1804 → (1804 ÷ 100) = 18.04
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Engine torque A7_ENG_TQ
- Request
22 10 10 - Service 22
DID 1010 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2010 to 2018.
Engine torque A7_ENG_TQ_7E1
- Request
22 20 02 - Service 22
DID 2002 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Engine torque A7_PQ35_ENG_TORQUEConfirmed
- Request
22 15 5A - Service 22
DID 155A - Module
7E0 → 7E8 - Every
250 ms - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 32) = 0 N·m
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 N·m
- Unit
- N·m
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Engine torque A7_PQ35_ENG_TRQConfirmed
- Request
22 10 47 - Service 22
DID 1047 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x013F = 319 → (319 ÷ 10) = 31.9 N·m
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Engine torque loss A7_MQB_TCM_ENGINE_TORQUE_LOSS
- Request
22 10 0F - Service 22
DID 100F - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35 N·m
- Unit
- N·m
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Environment data camshaft input 1 A7_PQ35_ENVD_CAM_IN_1Confirmed
- Request
22 12 13 - Service 22
DID 1213 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Evaporator temperature A7_EVAPORATOR_T
- Request
22 42 BB - Service 22
DID 42BB - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Excessive temperature protection A7_EXCESSIVE_T
- Request
22 21 17 - Service 22
DID 2117 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Exhaust camshaft, adaptation bias A7_EXH_CAM_ADPT_BIAS
- Request
22 17 4A - Service 22
DID 174A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2019 to 2026.
Exhaust camshaft, adaptation sensor tolerance A7_EXH_CAM_ADPT_SENS
- Request
22 17 55 - Service 22
DID 1755 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2019 to 2026.
Exhaust gas jet volume in particle filter, m^3/h A7_EXH_GAS_JET_VOLUME_M_3_H
- Request
22 3D 7E - Service 22
DID 3D7E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364
- Unit
- Number
In testing for 2019 to 2026.
Exhaust gas recirculation valve duty A7_PQ35_EGR_DUTYConfirmed
- Request
22 10 C2 - Service 22
DID 10C2 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x1CED = 7405 → (7405 ÷ 100) = 74.05 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Exhaust gas temperature before catalyst, modeled A7_EGT_PRE_CAT_MODELED
- Request
22 14 21 - Service 22
DID 1421 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Exhaust gas temperature sensor 1 A7_EXH_GAS_T_SENS_1
- Request
22 16 6F - Service 22
DID 166F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2018.
Exhaust gas temperature sensor 1 A7_PQ35_EXH_GAS_T_1Confirmed
- Request
22 10 FB - Service 22
DID 10FB - Module
7E0 → 7E8 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x1113 = 4371 → (4371 ÷ 10 − 273.1) = 164 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Exhaust gas temperature sensor 1, bank 2 A7_EXH_GAS_T_SENS_1_2
- Request
22 16 70 - Service 22
DID 1670 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2018.
Exhaust gas temperature sensor 2 A7_PQ35_EXHAUST_GAS_T_SENSOR_2Confirmed
- Request
22 14 F7 - Service 22
DID 14F7 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x1357 = 4951 → (4951 ÷ 10 − 273.1) = 222 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -3549.9 to 3003.6 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Exhaust gas temperature sensor 3 A7_EXH_GAS_T_SENS_3
- Request
22 14 BE - Service 22
DID 14BE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2018.
Exhaust gas temperature sensor 3, bank 2 A7_EXH_GAS_T_SENS_3_2
- Request
22 15 6F - Service 22
DID 156F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2010 to 2018.
Exhaust phase deviation, actual value A7_EXH_PHASE_DEV_ACT
- Request
22 41 85 - Service 22
DID 4185 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2019 to 2026.
Exhaust phase deviation, after chain replacement A7_EXH_PHASE_DEV_AFTER
- Request
22 41 7D - Service 22
DID 417D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2019 to 2026.
Exhaust phase deviation, after repair A7_EXH_PHASE_DEV_AFTER_REPAIR
- Request
22 41 81 - Service 22
DID 4181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2019 to 2026.
Exhaust timing chain extension, mileage since last adaptation A7_EXH_TIM_CHAIN
- Request
22 51 49 - Service 22
DID 5149 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Field limit value A7_PQ35_FIELD_LIMConfirmed
- Request
22 11 F6 - Service 22
DID 11F6 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0A88 = 2696 → (2696 ÷ 100) = 26.96
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Friction torque A7_FRICTION_TQ
- Request
22 10 65 - Service 22
DID 1065 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Front defrost flap air outlet temperature A7_FRONT_DEFROST_FLAP_T
- Request
22 42 C8 - Service 22
DID 42C8 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Front left deflector temperature A7_CLIMATE_FR_L_DEFL_TConfirmed
- Request
22 26 0C - Service 22
DID 260C - Module
746 → 7B0 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x46 = 70 → (70 ÷ 3) = 23.333333 °C
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Front right deflector temperature A7_CLIMATE_FR_R_DEFL_TConfirmed
- Request
22 26 0D - Service 22
DID 260D - Module
746 → 7B0 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x49 = 73 → (73 ÷ 3) = 24.333333 °C
- Formula
(val ÷ 3)- Range
- 0 to 84.915 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Fuel metering valve position A7_PQ35_FUEL_METERConfirmed
- Request
22 11 48 - Service 22
DID 1148 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Fuel temperature A7_PQ35_FUEL_TConfirmed
- Request
22 16 2D - Service 22
DID 162D - Module
7E0 → 7E8 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0BBB = 3003 → (3003 ÷ 10 − 273.1) = 27.2 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Generator current A7_GEN_CURRENT
- Request
22 2A 1C - Service 22
DID 2A1C - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2019 to 2026.
Generator load A7_PQ35_GEN_LOADConfirmed
- Request
22 10 5C - Service 22
DID 105C - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Generator load normalized value A7_GEN_LOAD_NORM
- Request
22 15 CA - Service 22
DID 15CA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2019 to 2026.
Generator load signal A7_GEN_LOAD_SIG
- Request
22 10 1C - Service 22
DID 101C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2019 to 2026.
Generator power A7_GEN_POWER
- Request
22 10 97 - Service 22
DID 1097 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 94247 ÷ 10000)- Range
- 0 to 617647 W
- Unit
- W
In testing for 2019 to 2026.
Generator torque request A7_GEN_TQ_REQ
- Request
22 10 1B - Service 22
DID 101B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Glow plug preheat time A7_PQ35_PREHEAT_TConfirmed
- Request
22 11 1F - Service 22
DID 111F - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 100) = 0 ms
- Formula
(val × 100)- Range
- -3276800 to 3276700 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Heater circulation pump, nominal value A7_HEATER_CIRCULATION
- Request
22 16 7F - Service 22
DID 167F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2019 to 2026.
Height correction A7_HEIGHT_CORR
- Request
22 11 36 - Service 22
DID 1136 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0000610348)- Range
- 0 to 3.99
- Unit
- Number
In testing for 2019 to 2026.
High pressure control, adaptation A7_HIGH_P_CTRL_ADPT
- Request
22 11 D2 - Service 22
DID 11D2 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2000)- Range
- -16.38 to 16.38
- Unit
- Raw value
In testing for 2019 to 2026.
High pressure EGR actuator, activation A7_HIGH_P_EGR_ACTUATOR
- Request
22 13 34 - Service 22
DID 1334 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2019 to 2026.
Humidity sensor, relative humidity A7_HUMIDITY_SENS_REL
- Request
22 50 36 - Service 22
DID 5036 - Module
70E → 778 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 99 ÷ 200)- Range
- 0 to 32439 %
- Unit
- %
In testing for 2019 to 2026.
Hybrid temperature A7_MQB_TCM_HYBRID_TConfirmed
- Request
22 11 96 - Service 22
DID 1196 - Module
7E1 → 7E9 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0381 = 897 → 897 °C
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
ID of current driving program A7_ID_CURRENT_DRIVING
- Request
22 10 12 - Service 22
DID 1012 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Injection amount deviation cylinder 1 A7_PQ35_INJ_DEV_CYL_1Confirmed
- Request
22 10 FF - Service 22
DID 10FF - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0023 = 35 → (35 ÷ 100) = 0.35
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injection amount deviation cylinder 2 A7_INJ_AMOUNT_DEV_CYL_2
- Request
22 11 06 - Service 22
DID 1106 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2018.
Injection amount deviation cylinder 2 A7_PQ35_INJ_DEV_CYL_2Confirmed
- Request
22 11 05 - Service 22
DID 1105 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0002 = 2 → (2 ÷ 100) = 0.02
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injection amount deviation cylinder 3 A7_PQ35_INJ_DEV_CYL_3Confirmed
- Request
22 11 00 - Service 22
DID 1100 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x002E = 46 → (46 ÷ 100) = 0.46
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injection amount deviation cylinder 4 A7_PQ35_INJ_DEV_CYL_4Confirmed
- Request
22 11 04 - Service 22
DID 1104 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x000B = 11 → (11 ÷ 100) = 0.11
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injection amount deviation cylinder 5 A7_INJ_AMOUNT_DEV_CYL_5
- Request
22 11 07 - Service 22
DID 1107 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2010 to 2018.
Injection quantity deviation, cylinder 1 A7_INJ_QTY_DEV_CYL_1
- Request
22 20 46 - Service 22
DID 2046 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Injection quantity deviation, cylinder 2 A7_INJ_QTY_DEV_CYL_2
- Request
22 20 4A - Service 22
DID 204A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Injection quantity deviation, cylinder 3 A7_INJ_QTY_DEV_CYL_3
- Request
22 20 48 - Service 22
DID 2048 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Injection quantity deviation, cylinder 4 A7_INJ_QTY_DEV_CYL_4
- Request
22 20 47 - Service 22
DID 2047 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Injection quantity deviation, cylinder 5 A7_INJ_QTY_DEV_CYL_5
- Request
22 20 4B - Service 22
DID 204B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Injection quantity deviation, cylinder 6 A7_INJ_QTY_DEV_CYL_6
- Request
22 20 49 - Service 22
DID 2049 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Injector 1 rail pressure calibration point 1 A7_PQ35_INJ_1_RAIL_P_1Confirmed
- Request
22 10 D0 - Service 22
DID 10D0 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0133 = 307 → (307 ÷ 20000) = 0.01535 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injector 1 rail pressure calibration point 2 A7_PQ35_INJ_1_RAIL_P_2Confirmed
- Request
22 10 D6 - Service 22
DID 10D6 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0011 = 17 → (17 ÷ 20000) = 0.00085 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Injector 1 rail pressure calibration point 3 A7_PQ35_INJ_1_RAIL_P_3Confirmed
- Request
22 10 DC - Service 22
DID 10DC - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFE1A = -486 → (-486 ÷ 20000) = -0.0243 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injector 2 rail pressure calibration point 1 A7_PQ35_INJ_2_RAIL_P_1Confirmed
- Request
22 10 D3 - Service 22
DID 10D3 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0001 = 1 → (1 ÷ 20000) = 0.00005 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Injector 2 rail pressure calibration point 2 A7_PQ35_INJ_2_RAIL_P_2Confirmed
- Request
22 10 D9 - Service 22
DID 10D9 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFF64 = -156 → (-156 ÷ 20000) = -0.0078 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injector 2 rail pressure calibration point 3 A7_PQ35_INJ_2_RAIL_P_3Confirmed
- Request
22 10 DF - Service 22
DID 10DF - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFEB4 = -332 → (-332 ÷ 20000) = -0.0166 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injector 2, rail pressure calibration point 1 A7_INJ_2_RAIL_P_1
- Request
22 10 D4 - Service 22
DID 10D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2018.
Injector 2, rail pressure calibration point 2 A7_INJ_2_RAIL_P_2
- Request
22 10 DA - Service 22
DID 10DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2018.
Injector 2: rail pressure calibration point 2 A7_INJ_2_RAIL_P_CAL_PT_2_1474
- Request
22 14 74 - Service 22
DID 1474 - Module
7E0 → 7E8 - Every
300 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20)- Range
- -1638.4 to 1638.35
- Unit
- Raw value
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Injector 3 rail pressure calibration point 1 A7_PQ35_INJ_3_RAIL_P_1Confirmed
- Request
22 10 D1 - Service 22
DID 10D1 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x00E7 = 231 → (231 ÷ 20000) = 0.01155 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injector 3 rail pressure calibration point 2 A7_PQ35_INJ_3_RAIL_P_2Confirmed
- Request
22 10 D2 - Service 22
DID 10D2 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x00BA = 186 → (186 ÷ 20000) = 0.0093 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injector 3 rail pressure calibration point 3 A7_PQ35_INJ_3_RAIL_P_3Confirmed
- Request
22 10 DD - Service 22
DID 10DD - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFF94 = -108 → (-108 ÷ 20000) = -0.0054 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injector 4 rail pressure calibration point 2 A7_PQ35_INJ_4_RAIL_P_2Confirmed
- Request
22 10 D8 - Service 22
DID 10D8 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFF4F = -177 → (-177 ÷ 20000) = -0.00885 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Injector 4 rail pressure calibration point 3 A7_PQ35_INJ_4_RAIL_P_3Confirmed
- Request
22 10 DE - Service 22
DID 10DE - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 20000) = 0 ms
- Formula
(val ÷ 20000)- Range
- -1.6384 to 1.63 ms
- Unit
- ms
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Injector 4, rail pressure calibration point 2 A7_INJ_4_RAIL_P_2
- Request
22 10 D7 - Service 22
DID 10D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2018.
Injector 5, rail pressure calibration point 1 A7_INJ_5_RAIL_P_1
- Request
22 10 D5 - Service 22
DID 10D5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2018.
Injector 5, rail pressure calibration point 2 A7_INJ_5_RAIL_P_2
- Request
22 10 DB - Service 22
DID 10DB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2018.
Injector 5, rail pressure calibration point 3 A7_INJ_5_RAIL_P_3
- Request
22 10 E1 - Service 22
DID 10E1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 20000)- Range
- -1.63 to 1.63 ms
- Unit
- ms
In testing for 2010 to 2018.
Inlet flaps - actual value A7_INLET_FLAPS_ACT
- Request
22 11 9D - Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Inlet flaps - requested value A7_INLET_FLAPS_REQ
- Request
22 11 A0 - Service 22
DID 11A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Inside temperature A7_INSIDE_T
- Request
22 26 13 - Service 22
DID 2613 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 50)- Range
- -50 to 6503 °C
- Unit
- °C
In testing for 2019 to 2026.
Intake air temperature A7_IAT
- Request
22 10 01 - Service 22
DID 1001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2010 to 2018.
Intake air temperature A7_IAT_7E0
- Request
22 14 9E - Service 22
DID 149E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2019 to 2026.
Intake air temperature raw value A7_IAT_RAW
- Request
22 15 C0 - Service 22
DID 15C0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2020.
Intake camshaft adaptation unit 1 phase length A7_PQ35_CAMS_ADAPT_PHASE_1Confirmed
- Request
22 12 FE - Service 22
DID 12FE - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xFF27 = -217 → (-217 ÷ 50) = -4.34 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Intake camshaft signal edge position adapted edge 2 A7_PQ35_CAMS_EDGE_POS_2Confirmed
- Request
22 11 89 - Service 22
DID 1189 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0xFFFF = 65535 → (65535 ÷ 16 − 32) = 4,063.9375 °
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Intake camshaft signal edge position adapted edge 3 A7_PQ35_CAMS_EDGE_POS_3Confirmed
- Request
22 11 8A - Service 22
DID 118A - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0xFFFF = 65535 → (65535 ÷ 16 − 32) = 4,063.9375 °
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Intake camshaft signal edge position adapted edge 4 A7_PQ35_CAMS_EDGE_POS_4Confirmed
- Request
22 11 8B - Service 22
DID 118B - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x5092 = 20626 → (20626 ÷ 16 − 32) = 1,257.125 °
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Intake camshaft signal edge position adapted edge 5 A7_PQ35_CAMS_EDGE_POS_5
- Request
22 11 8C - Service 22
DID 118C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Intake camshaft signal edge position adapted edge 6 A7_PQ35_CAMS_EDGE_POS_6
- Request
22 11 8D - Service 22
DID 118D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Intake camshaft signal edge position adapted edge 7 A7_PQ35_CAMS_EDGE_POS_7
- Request
22 11 8E - Service 22
DID 118E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Intake camshaft signal edge position adapted edge 8 A7_PQ35_CAMS_EDGE_POS_8
- Request
22 11 8F - Service 22
DID 118F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 32)- Range
- -32 to 4063.937 °
- Unit
- °
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Intake camshaft, adaptation bias A7_INT_CAM_ADPT_BIAS
- Request
22 17 4B - Service 22
DID 174B - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2019 to 2026.
Intake camshaft, adaptation sensor tolerance A7_INT_CAM_ADPT_SENS
- Request
22 17 40 - Service 22
DID 1740 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.021973)- Range
- -720 to 719 °
- Unit
- °
In testing for 2019 to 2026.
Intake manifold pressure, commanded A7_INT_MANIFOLD_P_CMD
- Request
22 11 DD - Service 22
DID 11DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2019 to 2026.
Intake manifold pressure, corrected A7_INT_MANIFOLD_P
- Request
22 11 DA - Service 22
DID 11DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2019 to 2026.
Intake model air mass flow filtered value A7_INT_MODEL_AIR_MASS
- Request
22 11 AB - Service 22
DID 11AB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2019 to 2026.
Intake phase deviation, actual value A7_INT_PHASE_DEV_ACT
- Request
22 18 00 - Service 22
DID 1800 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2019 to 2026.
Intake phase deviation, after chain replacement A7_INT_PHASE_DEV_AFTER
- Request
22 41 7B - Service 22
DID 417B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2019 to 2026.
Intake phase deviation, after repair A7_INT_PHASE_DEV_AFTER_REPAIR
- Request
22 41 7F - Service 22
DID 417F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °
- Unit
- °
In testing for 2019 to 2026.
Intake timing chain extension, mileage since last adaptation A7_INT_TIM_CHAIN
- Request
22 51 6C - Service 22
DID 516C - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2019 to 2026.
Integrated mass of air since engine start A7_INTEGRATED_MASS_AIR
- Request
22 11 75 - Service 22
DID 1175 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8889 ÷ 25000)- Range
- 0 to 23301
- Unit
- Raw value
In testing for 2019 to 2026.
Integrated mass of air since the first engine start A7_INTEGRATED_MASS_AIR_SINCE
- Request
22 17 43 - Service 22
DID 1743 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8889 ÷ 25000)- Range
- 0 to 23301
- Unit
- Raw value
In testing for 2019 to 2026.
Intercooler air output temperature A7_PQ35_INTERCOOLER_AIR_OUTPUT_TConfirmed
- Request
22 16 28 - Service 22
DID 1628 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0B61 = 2913 → (2913 ÷ 10 − 273.1) = 18.2 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Kick down A7_MQB_TCM_KICK_DOWNConfirmed
- Request
22 21 14 - Service 22
DID 2114 - Module
7E1 → 7E9 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Kilometers driven since last event on K1 A7_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1Confirmed
- Request
22 11 5A - Service 22
DID 115A - Module
7E1 → 7E9 - Every
30 s - Testing for 2010, 2013 to 2026
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10)- Range
- 0 to 7000 km
- Unit
- km
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Kilometers driven since last event on K2 A7_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2Confirmed
- Request
22 11 5C - Service 22
DID 115C - Module
7E1 → 7E9 - Every
30 s - Testing for 2010, 2013 to 2026
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10)- Range
- 0 to 7000 km
- Unit
- km
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Knock retard 4 A7_KNOCK_RETARD_4
- Request
22 10 E7 - Service 22
DID 10E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2010 to 2018.
Knock retard 6 A7_KNOCK_RETARD_6
- Request
22 10 E5 - Service 22
DID 10E5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2010 to 2018.
Knock retard:, cylinder 1 A7_KNOCK_RETARD_CYL_1
- Request
22 13 F2 - Service 22
DID 13F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2010 to 2018.
Knock retard:, cylinder 2 A7_KNOCK_RETARD_CYL_2
- Request
22 13 F3 - Service 22
DID 13F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2010 to 2018.
Knock retard:, cylinder 3 A7_KNOCK_RETARD_CYL_3
- Request
22 13 F4 - Service 22
DID 13F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2010 to 2018.
Knock retard:, cylinder 4 A7_KNOCK_RETARD_CYL_4
- Request
22 13 F5 - Service 22
DID 13F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2010 to 2018.
Knock retard:, cylinder 5 A7_KNOCK_RETARD_CYL_5
- Request
22 13 F6 - Service 22
DID 13F6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2010 to 2018.
Knock retard:, cylinder 6 A7_KNOCK_RETARD_CYL_6
- Request
22 13 F7 - Service 22
DID 13F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 − 48)- Range
- -48 to 47.62 °
- Unit
- °
In testing for 2010 to 2018.
Knock sensor, cylinder 1 A7_KNOCK_SENS_CYL_1
- Request
22 12 0E - Service 22
DID 120E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 7.62e-7)- Range
- 0 to 3272
- Unit
- Number
In testing for 2019 to 2026.
Knock sensor, cylinder 2 A7_KNOCK_SENS_CYL_2
- Request
22 12 12 - Service 22
DID 1212 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 7.62e-7)- Range
- 0 to 3272
- Unit
- Number
In testing for 2019 to 2026.
Knock sensor, cylinder 3 A7_KNOCK_SENS_CYL_3
- Request
22 12 10 - Service 22
DID 1210 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 7.62e-7)- Range
- 0 to 3272
- Unit
- Number
In testing for 2019 to 2026.
Knock sensor, cylinder 4 A7_KNOCK_SENS_CYL_4
- Request
22 12 0F - Service 22
DID 120F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 7.62e-7)- Range
- 0 to 3272
- Unit
- Number
In testing for 2019 to 2026.
Knock sensor, cylinder 6 A7_KNOCK_SENS_CYL_6
- Request
22 12 11 - Service 22
DID 1211 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 7.62e-7)- Range
- 0 to 3272
- Unit
- Number
In testing for 2019 to 2026.
Lambda output value A7_LAMBDA_OUTPUT
- Request
22 15 D4 - Service 22
DID 15D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 199997 ÷ 6553500000)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2019 to 2026.
Launch control counter A7_LAUNCH_CTRL_CNT
- Request
22 38 F1 - Service 22
DID 38F1 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Left central air outlet temperature A7_LEFT_CENTRAL_AIR_T
- Request
22 42 C5 - Service 22
DID 42C5 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Left foot well air outlet temperature A7_LEFT_FOOTWELL_AIR_T
- Request
22 42 BC - Service 22
DID 42BC - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Left rear foot well air outlet temperature A7_LEFT_REAR_FOOTWELL_T
- Request
22 42 C1 - Service 22
DID 42C1 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Left rear upper air outlet temperature A7_LEFT_REAR_HI_AIR_T
- Request
22 42 BE - Service 22
DID 42BE - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Left side air outlet temperature A7_LEFT_SIDE_AIR_OUTLET_T
- Request
22 42 C3 - Service 22
DID 42C3 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2020. Supported for 2021.
Long term fuel trim at idle - direct injection A7_LONG_TERM_FUEL_TRIM_IDLE
- Request
22 17 7E - Service 22
DID 177E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 3 ÷ 64)- Range
- -1536 to 1535 %
- Unit
- %
In testing for 2019 to 2026.
Long term fuel trim at idle - port injection A7_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ
- Request
22 17 80 - Service 22
DID 1780 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 3 ÷ 64)- Range
- -1536 to 1535 %
- Unit
- %
In testing for 2019 to 2026.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Request
01 56 - Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2020.
Long term throttle adaptation to MAF sensor A7_LONG_TERM_THROTTLE
- Request
22 11 3A - Service 22
DID 113A - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0000610351)- Range
- 0 to 3.99 %
- Unit
- %
In testing for 2019 to 2026.
M009, desired solenoid out 10 A7_M009_DES_SOLENOID_10
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
M009, desired solenoid out 11 A7_M009_DES_SOLENOID_11
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
M009, desired solenoid out 12 A7_M009_DES_SOLENOID_12
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
M009, desired solenoid out 13 A7_M009_DES_SOLENOID_13
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
M009, desired solenoid out 14 A7_M009_DES_SOLENOID_14
- Request
22 10 2E - Service 22
DID 102E - Module
7E1 → 7E9 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
Main catalyst aging factor A7_MAIN_CAT_AGING
- Request
22 14 F9 - Service 22
DID 14F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 24581 ÷ 8054700000)- Range
- 0 to 0.199
- Unit
- Number
In testing for 2019 to 2026.
Main injection duration A7_PQ35_MAIN_INJ_DURATIONConfirmed
- Request
22 14 CF - Service 22
DID 14CF - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x02A2 = 674 → (674 × 0.4 ÷ 1000) = 0.2696 ms
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Main injection start position A7_PQ35_MAIN_INJ_STARTConfirmed
- Request
22 11 F2 - Service 22
DID 11F2 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 50) = 0 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Manifold absolute pressure, raw value A7_MAP_RAW
- Request
22 11 DC - Service 22
DID 11DC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2019 to 2026.
Mass air flow through throttle A7_MAF_THROUGH_THROTTLE
- Request
22 11 AC - Service 22
DID 11AC - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2019 to 2026.
Mass air flow, commanded A7_MAF_CMD
- Request
22 11 AD - Service 22
DID 11AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2019 to 2026.
Mass airflow sensor 1 bank 1 raw value A7_MQB_MAF_1_B1_RAWConfirmed
- Request
22 10 26 - Service 22
DID 1026 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 1000 ÷ 10000) = 0
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Max permissible engine torque A7_MAX_PERMISSIBLE_ENG
- Request
22 21 1A - Service 22
DID 211A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Maximum ECU temperature A7_MAX_ECU_T
- Request
22 46 49 - Service 22
DID 4649 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Mean injection quantity A7_MEAN_INJ_QUANTITYConfirmed
- Request
22 11 39 - Service 22
DID 1139 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x37FA = 14330 → (14330 ÷ 100) = 143.3
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Median injection timing A7_MEDIAN_INJ_TIM
- Request
22 12 8C - Service 22
DID 128C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2010 to 2018.
Misfires / 1000 revolutions, cylinder 1 A7_MISFIRES_1000REV_C1Confirmed
- Request
22 11 47 - Service 22
DID 1147 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Misfires / 1000 revolutions, cylinder 2 A7_MISFIRES_1000REV_C2Confirmed
- Request
22 11 4A - Service 22
DID 114A - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Misfires counter:, cylinder 1 A7_MIS_CNT_1
- Request
22 14 7E - Service 22
DID 147E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Misfires counter:, cylinder 2 A7_MIS_CNT_2
- Request
22 14 82 - Service 22
DID 1482 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Misfires counter:, cylinder 3 A7_MIS_CNT_3
- Request
22 14 80 - Service 22
DID 1480 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Misfires counter:, cylinder 4 A7_MIS_CNT_4
- Request
22 14 7F - Service 22
DID 147F - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Misfires counter:, cylinder 5 A7_MIS_CNT_5
- Request
22 14 83 - Service 22
DID 1483 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Misfires counter:, cylinder 6 A7_MIS_CNT_6
- Request
22 14 81 - Service 22
DID 1481 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Misfires for 1000 revolutions, cylinder 1 A7_MIS_1000_REVOLUTIONS_1
- Request
22 29 1D - Service 22
DID 291D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires for 1000 revolutions, cylinder 2 A7_MIS_1000_REVOLUTIONS_2
- Request
22 29 20 - Service 22
DID 2920 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires for 1000 revolutions, cylinder 3 A7_MIS_1000_REVOLUTIONS_3
- Request
22 29 1E - Service 22
DID 291E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires for 1000 revolutions, cylinder 4 A7_MIS_1000_REVOLUTIONS_4
- Request
22 29 1F - Service 22
DID 291F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires per 1000 revolutions 2 A7_MIS_PER_1000_2
- Request
22 11 4B - Service 22
DID 114B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Misfires per 1000 revolutions 4 A7_MIS_PER_1000_4
- Request
22 11 4C - Service 22
DID 114C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2018.
Misfires total A7_MISFIRES_TOTALConfirmed
- Request
22 11 46 - Service 22
DID 1146 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Misfires, cylinder 1 A7_MIS_1
- Request
22 29 66 - Service 22
DID 2966 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, cylinder 2 A7_MIS_2
- Request
22 29 69 - Service 22
DID 2969 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, cylinder 3 A7_MIS_3
- Request
22 29 67 - Service 22
DID 2967 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, cylinder 3 A7_MISFIRES_C3_ECMConfirmed
- Request
22 11 50 - Service 22
DID 1150 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x5DE1 = 24033 → 24,033
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Misfires, cylinder 4 A7_MIS_4
- Request
22 29 68 - Service 22
DID 2968 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Number of automatic engine starts A7_NUM_AUTOMATIC_ENG
- Request
22 29 99 - Service 22
DID 2999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Number of engine starts, manual A7_NUM_ENG_STARTS
- Request
22 29 98 - Service 22
DID 2998 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Number of injections A7_NUM_INJECTIONS
- Request
22 43 0E - Service 22
DID 430E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Oil ash limit A7_OIL_ASH_LIM
- Request
22 17 93 - Service 22
DID 1793 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Oil ash residue A7_PQ35_OIL_ASH_RESIDUEConfirmed
- Request
22 17 8C - Service 22
DID 178C - Module
7E0 → 7E8 - Every
1 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 10) = 0
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Raw value
Confirmed for 2020. In testing for 2010 to 2019, 2021 to 2026.
Oil dynamic average measurement A7_PQ35_OIL_DYN_AVGConfirmed
- Request
22 12 3F - Service 22
DID 123F - Module
7E0 → 7E8 - Every
30 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0xFFB7 = 65463 → (65463 ÷ 250) = 261.852 mm
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Oil last dynamic measurement A7_PQ35_OIL_DYN_LASTConfirmed
- Request
22 12 3C - Service 22
DID 123C - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x018D = 397 → (397 ÷ 250) = 1.588 mm
- Formula
(val ÷ 250)- Range
- 0 to 262.14 mm
- Unit
- mm
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Oil level A7_OIL_LEVELConfirmed
- Request
22 11 BA - Service 22
DID 11BA - Module
7E0 → 7E8 - Every
15 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x457A = 17786 → (17786 ÷ 2500) = 7.1144 cm
- Formula
(val ÷ 2500)- Range
- 0 to 26.2 cm
- Unit
- cm
Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.
Oil level method 1 A7_OIL_LEVEL_METHOD_1
- Request
22 1A F9 - Service 22
DID 1AF9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2019 to 2026.
Oil level method 2 A7_OIL_LEVEL_METHOD_2
- Request
22 1A FA - Service 22
DID 1AFA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2019 to 2026.
Oil level method 3 A7_OIL_LEVEL_METHOD_3
- Request
22 1A FB - Service 22
DID 1AFB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2019 to 2026.
Oil level, average dynamic value A7_OIL_LEVEL_AVG
- Request
22 15 B9 - Service 22
DID 15B9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2019 to 2026.
Oil level, static measurement A7_OIL_LEVEL_STATIC
- Request
22 40 CE - Service 22
DID 40CE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 127)- Range
- -127 to 3968 mm
- Unit
- mm
In testing for 2010 to 2018.
Oil p A7_OIL_P
- Request
22 25 CD - Service 22
DID 25CD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2019 to 2026.
Oil pressure control valve activation pulse duty factor A7_OIL_P_CTRL_VLV
- Request
22 25 D0 - Service 22
DID 25D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2019 to 2026.
Oil pressure control valve, activation pulse duty factor A7_OIL_P_CTRL_VLV_ACTIVATION
- Request
22 4F 97 - Service 22
DID 4F97 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2019 to 2026.
Oil pressure sensor-piston cooling nozzle switch, status A7_OIL_P_SENS_PISTON
- Request
22 15 BD - Service 22
DID 15BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Oil pressure sensor, raw value A7_OIL_P_SENS_RAW
- Request
22 1B 02 - Service 22
DID 1B02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Oil pressure switch valve activation A7_OIL_P_SWITCH_VLV
- Request
22 13 B8 - Service 22
DID 13B8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Oil pressure target A7_OIL_P_TGT
- Request
22 25 CF - Service 22
DID 25CF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2019 to 2026.
Oil pressure target A7_OIL_P_TGT_7E0
- Request
22 4F 70 - Service 22
DID 4F70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2019 to 2026.
Oil pressure, actual value A7_OIL_P_ACT_7E0
- Request
22 17 7D - Service 22
DID 177D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 kPa
- Unit
- kPa
In testing for 2019 to 2026.
Oil pressure, actual value A7_OIL_P_ACT_7E0_2
- Request
22 1B 04 - Service 22
DID 1B04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2019 to 2026.
Oil sump temperature A7_OIL_SUMP_T
- Request
22 15 B7 - Service 22
DID 15B7 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2019 to 2026.
Oil temp 2 A7_PQ35_ENGINE_OIL_T_2
- Request
22 17 9C - Service 22
DID 179C - Module
7E0 → 7E8 - Every
5 s - Testing for 2010 to 2019, 2021 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
In testing for 2010, 2013 to 2019, 2021 to 2026. Supported for 2020. Not supported for 2011 to 2012.
Oil thermal wear A7_DASH_OIL_THERMAL_WEARConfirmed
- Request
22 22 4B - Service 22
DID 224B - Module
714 → 77E - Every
300 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0031 = 49 → 49 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Outside temperature A7_OUTSIDE_T
- Request
22 22 0C - Service 22
DID 220C - Module
714 → 77E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 50)- Range
- -50 to 77.5 °C
- Unit
- °C
In testing for 2019 to 2026.
Overall energy balance A7_OVERALL_ENERGY
- Request
22 2A 17 - Service 22
DID 2A17 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits. The value is signed.
- Formula
(val × 21 ÷ 20)- Range
- -8808038 to 8808037 Ah
- Unit
- Ah
In testing for 2019 to 2026.
Oxygen sensor 1 bank 1 lambda value A7_PQ35_O2_SEN_1_LAMBDAConfirmed
- Request
22 11 3D - Service 22
DID 113D - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0D05 = 3333 → (3333 ÷ 100) = 33.33
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Number
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Particle sensor, cleaning deviation reaction time A7_PARTICLE_SENS
- Request
22 44 F5 - Service 22
DID 44F5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -32.76 to 32.76
- Unit
- Number
In testing for 2019 to 2026.
Particle sensor, exhaust temperature A7_PARTICLE_SENS_EXH_T
- Request
22 44 F8 - Service 22
DID 44F8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2019 to 2026.
Particle sensor, soot volume in exhaust A7_PARTICLE_SENS_SOOT
- Request
22 44 F7 - Service 22
DID 44F7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2019 to 2026.
Particle sensor, surface temperature A7_PARTICLE_SENS_T
- Request
22 44 FB - Service 22
DID 44FB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16 − 273.15)- Range
- -2321 to 1774 °C
- Unit
- °C
In testing for 2019 to 2026.
Particle sensor, time in op.mode measurement A7_PARTICLE_SENS_TIME
- Request
22 46 D4 - Service 22
DID 46D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2019 to 2026.
Pilot injection 1 duration A7_PQ35_PRE_INJ_1_DURATIONConfirmed
- Request
22 14 D0 - Service 22
DID 14D0 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 0.4 ÷ 1000) = 0 ms
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Pilot injection 1 start position A7_PQ35_PRE_INJ_1_STARTConfirmed
- Request
22 14 C7 - Service 22
DID 14C7 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x02C2 = 706 → (706 ÷ 50) = 14.12 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Pilot injection 2 duration A7_PQ35_PRE_INJ_2_DURATIONConfirmed
- Request
22 14 D1 - Service 22
DID 14D1 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 0.4 ÷ 1000) = 0 ms
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Pilot injection 2 start A7_PQ35_PRE_INJ_2_STARTConfirmed
- Request
22 14 C8 - Service 22
DID 14C8 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x006A = 106 → (106 ÷ 50) = 2.12 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Pilot injection 3, start A7_PRE_INJ_3_START
- Request
22 16 31 - Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 21973 ÷ 1000000)- Range
- -720 to 719 °
- Unit
- °
In testing for 2019 to 2026.
Piston cooling nozzles, control A7_PISTON_COOLING
- Request
22 16 F4 - Service 22
DID 16F4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Post injection 1: quantity specified value A7_PQ35_POST_INJ_1_QTY_SPECConfirmed
- Request
22 16 3C - Service 22
DID 163C - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Post injection 2: quantity specified value A7_PQ35_POST_INJ_2_QTY_SPECConfirmed
- Request
22 16 3B - Service 22
DID 163B - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Post injection 3: quantity specified value A7_PQ35_POST_INJ_3_QTY_SPECConfirmed
- Request
22 16 7D - Service 22
DID 167D - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 100) = 0
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Post-injection 1 duration A7_PQ35_POST_INJ_1_DURATIONConfirmed
- Request
22 14 CC - Service 22
DID 14CC - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 0.4 ÷ 1000) = 0 ms
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Post-injection 1 start position A7_PQ35_POST_INJ_1_STARTConfirmed
- Request
22 11 F4 - Service 22
DID 11F4 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 50) = 0 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Post-injection 2 duration A7_PQ35_POST_INJ_2_DURATIONConfirmed
- Request
22 14 CD - Service 22
DID 14CD - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 0.4 ÷ 1000) = 0 ms
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Post-injection 2 start position A7_PQ35_POST_INJ_2_STARTConfirmed
- Request
22 11 F3 - Service 22
DID 11F3 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 50) = 0 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Post-injection 3 activation duration A7_PQ35_POST_INJ_3_ACTIVATION_DURATIONConfirmed
- Request
22 14 CE - Service 22
DID 14CE - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x1D5B = 7515 → (7515 × 0.4 ÷ 1000) = 3.006 ms
- Formula
(val × 0.4 ÷ 1000)- Range
- -13.1072 to 13.1068 ms
- Unit
- ms
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Post-injection 3 start position A7_PQ35_POST_INJ_3_STARTConfirmed
- Request
22 11 31 - Service 22
DID 1131 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 50) = 0 °
- Formula
(val ÷ 50)- Range
- -655.36 to 655.34 °
- Unit
- °
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Pressure before throttle valve - actual value A7_P_BEFORE_THROTTLE_ACT
- Request
22 11 EE - Service 22
DID 11EE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2019 to 2026.
Pressure before throttle valve - sensor measured A7_P_BEFORE_THROTTLE
- Request
22 11 EF - Service 22
DID 11EF - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 21333 ÷ 546125)- Range
- 0 to 2559
- Unit
- Raw value
In testing for 2019 to 2026.
Pressure sensor 1 temperature A7_MQB_DL382_P_SENSOR_1_TConfirmed
- Request
22 13 2A - Service 22
DID 132A - Module
7E1 → 7E9 - Every
5 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0029 = 41 → 41 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Pressure sensor 2 temperature A7_MQB_DL382_P_SENSOR_2_TConfirmed
- Request
22 13 2B - Service 22
DID 132B - Module
7E1 → 7E9 - Every
5 s - Testing for 2010 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0029 = 41 → 41 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.
Pressure supply actual pressure A7_MQB_DQ200_P_SUPPLY_ACTUAL_PConfirmed
- Request
22 11 91 - Service 22
DID 1191 - Module
7E1 → 7E9 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0xA603 = -23037 → (-23037 ÷ 100) = -230.37 bar
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 bar
- Unit
- bar
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Pressure supply actual pressure analog digital value A7_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE
- Request
22 10 2D - Service 22
DID 102D - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Radiator fan commanded duty A7_CLIMATE_RAD_FAN_CMD_DUTYConfirmed
- Request
22 26 07 - Service 22
DID 2607 - Module
746 → 7B0 - Every
2 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2.5) = 0 %
- Formula
(val ÷ 2.5)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Radiator outlet coolant temperature commanded A7_PQ35_RAD_COOL_T_CMDConfirmed
- Request
22 11 11 - Service 22
DID 1111 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0E25 = 3621 → (3621 ÷ 10 − 273.1) = 89 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Radiator output coolant temp: actual A7_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUALConfirmed
- Request
22 16 26 - Service 22
DID 1626 - Module
7E0 → 7E8 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0B4B = 2891 → (2891 ÷ 10 − 273.1) = 16 °C
- Formula
(val ÷ 10 − 273.1)- Range
- -273.1 to 6280.4 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Rated drive torque A7_RATED_DRIVE_TQ
- Request
22 14 A1 - Service 22
DID 14A1 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Reached maximum temperature A7_PQ35_REACHED_MAXIMUM_T
- Request
22 11 17 - Service 22
DID 1117 - Module
7E1 → 7E9 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Reducing agent tank volume, act. value filtered A7_REDUCING_AGENT_TANK_ACT
- Request
22 1A 6C - Service 22
DID 1A6C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 L
- Unit
- L
In testing for 2019 to 2026.
Refrigerant pressure A7_CLIMATE_REFRIG_PConfirmed
- Request
22 26 05 - Service 22
DID 2605 - Module
746 → 7B0 - Every
5 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x22 = 34 → (34 ÷ 5) = 6.8 bar
- Formula
(val ÷ 5)- Range
- 0 to 51 bar
- Unit
- bar
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Refrigerant pressure A7_REFRIGERANT_P
- Request
22 26 05 - Service 22
DID 2605 - Module
70E → 778 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 bar
- Unit
- bar
In testing for 2019 to 2026.
Regulation factor total A7_PQ35_REG_FACTORConfirmed
- Request
22 10 E4 - Service 22
DID 10E4 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x2000 = 8192 → (8192 ÷ 10000) = 0.8192 %
- Formula
(val ÷ 10000)- Range
- 0 to 3.276 %
- Unit
- %
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Relative load value A7_REL_LOAD
- Request
22 12 16 - Service 22
DID 1216 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 913 ÷ 38950)- Range
- 0 to 1536
- Unit
- Number
In testing for 2019 to 2026.
Requested torque, amount for auxiliary units A7_REQ_TQ_AMOUNT
- Request
22 10 BE - Service 22
DID 10BE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Reserve torque A7_RESERVE_TQ
- Request
22 10 6A - Service 22
DID 106A - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Result of crankcase ventilation test, fail A7_RESULT_CRANKCASE
- Request
22 15 CC - Service 22
DID 15CC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Result of crankcase ventilation test, successful A7_RESULT_CRANKCASE_VENTILATION_TEST
- Request
22 15 CB - Service 22
DID 15CB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Right central air outlet temperature A7_RIGHT_CENTRAL_AIR_T
- Request
22 42 C6 - Service 22
DID 42C6 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Right foot well air outlet temperature A7_RIGHT_FOOTWELL_AIR_T
- Request
22 42 BD - Service 22
DID 42BD - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Right rear foot well air outlet temperature A7_RIGHT_REAR_FOOTWELL_T
- Request
22 42 C2 - Service 22
DID 42C2 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Right rear upper air outlet temperature A7_RIGHT_REAR_HI_AIR_T
- Request
22 42 C0 - Service 22
DID 42C0 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Right side air outlet temperature A7_RIGHT_SIDE_AIR_T
- Request
22 42 C4 - Service 22
DID 42C4 - Module
70E → 778 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 50)- Range
- -50 to 4045 °C
- Unit
- °C
In testing for 2019 to 2026.
Route data, active A7_ROUTE_DATA_ACTIVE
- Request
22 28 2C - Service 22
DID 282C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Sensor for particle filter differential pressure, raw value A7_SENS_PARTICLE_FLT_P
- Request
22 39 E9 - Service 22
DID 39E9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2019 to 2026.
Service interval extension, max oil level A7_WIV_MAX_OIL_LEVEL
- Request
22 12 30 - Service 22
DID 1230 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2019 to 2026.
Service interval extension, min oil level A7_WIV_MIN_OIL_LEVEL
- Request
22 12 31 - Service 22
DID 1231 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 250)- Range
- 0 to 262 mm
- Unit
- mm
In testing for 2019 to 2026.
Service limit value A7_PQ35_SRV_LIMConfirmed
- Request
22 12 CB - Service 22
DID 12CB - Module
7E0 → 7E8 - Every
30 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x0D20 = 3360 → (3360 ÷ 100) = 33.6
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2020. Supported for 2021.
SIM card, SIM card in main unit A7_SIM_CARD_SIM_CARD
- Request
22 18 14 - Service 22
DID 1814 - Module
773 → 7DD - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Simulated DPF temperature A7_SIMULATED_DPF_T
- Request
22 3D 7F - Service 22
DID 3D7F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2019 to 2026.
Smoke limit A7_PQ35_LIM_SMOKEConfirmed
- Request
22 13 01 - Service 22
DID 1301 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x06D6 = 1750 → (1750 ÷ 10) = 175 N·m
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Solenoid current A7_SOLENOID_CURRENT
- Request
22 18 00 - Service 22
DID 1800 - Module
70F → 779 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 6250000)- Range
- -63.99 to 63.99 A
- Unit
- A
In testing for 2019 to 2026.
Spark efficiency deviation at part load A7_SPARK_EFFICIENCY_DEV
- Request
22 11 2D - Service 22
DID 112D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 781 ÷ 1000)- Range
- 0 to 199 %
- Unit
- %
In testing for 2019 to 2026.
Static torque limitation A7_STATIC_TQ_LIM
- Request
22 10 66 - Service 22
DID 1066 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Status CC ECU, temperature. st.disc A7_STAT_CC_ECU_T_ST
- Request
22 11 0A - Service 22
DID 110A - Module
70F → 779 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 39 ÷ 2500)- Range
- -511 to 511 °C
- Unit
- °C
In testing for 2019 to 2026.
Temperature after evaporator A7_CLIMATE_T_AFTER_EVAPConfirmed
- Request
22 26 12 - Service 22
DID 2612 - Module
746 → 7B0 - Every
5 s - Testing for 2010, 2013 to 2026
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 3)- Range
- -42.624 to 42.291 °C
- Unit
- °C
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Temperature status, controller A7_STAT_NIA_T
- Request
22 11 01 - Service 22
DID 1101 - Module
70F → 779 - Every
5 s - Testing
Bits 136 to 151 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2019 to 2026.
Temperature status, RPS A7_STAT_NIA_T_RPS
- Request
22 11 01 - Service 22
DID 1101 - Module
70F → 779 - Every
5 s - Testing
Bits 152 to 167 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2019 to 2026.
Temperature status, SBC A7_STAT_NIA_T_SBC
- Request
22 11 01 - Service 22
DID 1101 - Module
70F → 779 - Every
5 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2019 to 2026.
Thermostat, actual A7_THERMOSTAT_ACT
- Request
22 44 18 - Service 22
DID 4418 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 1000000)- Range
- 0 to 799 %
- Unit
- %
In testing for 2019 to 2026.
Thermostat, commanded A7_THERMOSTAT_CMD
- Request
22 44 17 - Service 22
DID 4417 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12207 ÷ 1000000)- Range
- 0 to 799 %
- Unit
- %
In testing for 2019 to 2026.
Throttle regulator nominal value A7_THROTTLE_REGULATOR
Pelican can show this parameter as the throttle position.
- Request
22 16 C5 - Service 22
DID 16C5 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 %
- Unit
- %
In testing for 2019 to 2026.
Throttle valve adapter position A7_PQ35_THROT_VALVE_ADAPTConfirmed
- Request
22 12 FC - Service 22
DID 12FC - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0519 = 1305 → (1305 ÷ 100) = 13.05 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Time in after-run A7_TIME_AFTERRUN
- Request
22 10 3A - Service 22
DID 103A - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2019 to 2026.
Time since reset A7_TIME_SINCE_RESET
- Request
22 10 3B - Service 22
DID 103B - Module
7E1 → 7E9 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 30)- Range
- 0 to 7650 ms
- Unit
- ms
In testing for 2019 to 2026.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2020. Supported for 2021.
Torque factor A7_TQ_FACTOR
- Request
22 21 19 - Service 22
DID 2119 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Torque increase request from ESP A7_TQ_INCREASE_REQ_ESP
- Request
22 13 40 - Service 22
DID 1340 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Torque limit A7_PQ35_LIM_TRQConfirmed
- Request
22 10 6B - Service 22
DID 106B - Module
7E0 → 7E8 - Every
250 ms - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0674 = 1652 → (1652 ÷ 10) = 165.2 N·m
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Torque limitation A7_TQ_LIM
- Request
22 10 7D - Service 22
DID 107D - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Torque loss adaptation at idle A7_TQ_LOSS_ADPT_IDLE
- Request
22 12 25 - Service 22
DID 1225 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Torque loss adaptation, A/C compressor A7_TQ_LOSS_ADPT_AC_COMP
- Request
22 12 23 - Service 22
DID 1223 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Torque reduction due to exhaust temperature A7_PQ35_TRQ_RED_EXH_TConfirmed
- Request
22 10 E3 - Service 22
DID 10E3 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x2000 = 8192 → (8192 ÷ 10000) = 0.8192
- Formula
(val ÷ 10000)- Range
- -3.2768 to 3.276
- Unit
- Number
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Torque reduction request from ESP A7_TQ_REDUCTION_REQ_ESP
- Request
22 13 3F - Service 22
DID 133F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Torque transmitting function, ratio A7_TQ_TRANSMITTING
- Request
22 21 05 - Service 22
DID 2105 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Number
In testing for 2019 to 2026.
Total mass of gasoline and ethyl alcohol in oil A7_TOT_MASS_GASOLINE
- Request
22 17 13 - Service 22
DID 1713 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.021333)- Range
- 0 to 1398
- Unit
- Raw value
In testing for 2019 to 2026.
Transmission drag torque A7_TCM_DRAG_TQ
- Request
22 10 21 - Service 22
DID 1021 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Transmission torque losses A7_TCM_TQ_LOSSES
- Request
22 10 22 - Service 22
DID 1022 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Turbine actuator 1 bank 1 activation A7_PQ35_TURB_ACT_1_B1Confirmed
- Request
22 11 7E - Service 22
DID 117E - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x199A = 6554 → (6554 ÷ 100) = 65.54 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Turbine actuator 1 bank 1: activation A7_ACT
- Request
22 11 2C - Service 22
DID 112C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.
Valve lift system, result of last switch, intake A7_VLV_LIFT_SYSTEM
- Request
22 16 BE - Service 22
DID 16BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Valve lift system, valve lift, exhaust A7_VLV_LIFT_SYSTEM_VLV
- Request
22 16 BB - Service 22
DID 16BB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Valve lift system, valve lift, intake A7_VLV_LIFT_SYSTEM_VLV_LIFT
- Request
22 16 BA - Service 22
DID 16BA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Valve timing, the difference between the, actual and the set angle A7_VLV_TIM_DIFF_ACT_SET
- Request
22 10 EC - Service 22
DID 10EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °
- Unit
- °
In testing for 2019 to 2026.
Variable valve timing, intake, bank 1, regulation A7_VARIABLE_VLV_TIM_INT_1
- Request
22 12 7B - Service 22
DID 127B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030517549)- Range
- 0 to 199 %
- Unit
- %
In testing for 2019 to 2026.
Variable valve timing, intake, bank 1, switch on A7_VARIABLE_VLV_TIM_INT_1_ON
- Request
22 12 7D - Service 22
DID 127D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030517549)- Range
- 0 to 199 %
- Unit
- %
In testing for 2019 to 2026.
Wear index A7_PQ35_WEAR_IDXConfirmed
- Request
22 10 E2 - Service 22
DID 10E2 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0003 = 3 → 3 m
- Formula
val- Range
- -32768 to 32767 m
- Unit
- m
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Engine › DPF
Diesel particulate filter field regeneration lock status A7_PQ35_DPF_FIELD_REGEN_LOCKConfirmed
- Request
22 11 C1 - Service 22
DID 11C1 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Diesel particulate filter fuel consumption since last regeneration A7_PQ35_DPF_FUEL_CON_REGENConfirmed
- Request
22 11 5A - Service 22
DID 115A - Module
7E0 → 7E8 - Every
30 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0AA8 = 2728 → (2728 ÷ 100) = 27.28 L
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 L
- Unit
- L
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Distance since last regeneration A7_PQ35_DIST_LAST_REGENConfirmed
- Request
22 11 56 - Service 22
DID 1156 - Module
7E0 → 7E8 - Every
30 s - Testing for 2010, 2013 to 2015, 2017 to 2026
Example reply from a 2016 Audi A7.
Bits 0 to 31 of the reply, 32 bits.
0x00049BE3 = 302051 → (302051 ÷ 1000) = 302.051 km
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
Confirmed for 2011 to 2012, 2016. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2020.
Regeneration duration A7_PQ35_REGEN_DURConfirmed
- Request
22 13 47 - Service 22
DID 1347 - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 31 of the reply, 32 bits.
0x00000000 = 0 → 0 min
- Formula
val- Range
- 0 to 4294967295 min
- Unit
- min
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Service regeneration status A7_PQ35_SRV_REGEN_STATConfirmed
- Request
22 11 5C - Service 22
DID 115C - Module
7E0 → 7E8 - Every
30 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 7 of the reply, 8 bits.
0x05 = 5 → 5
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Soot index A7_PQ35_SOOT_IDXConfirmed
- Request
22 13 54 - Service 22
DID 1354 - Module
7E0 → 7E8 - Every
30 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → 0 m
- Formula
val- Range
- -32768 to 32767 m
- Unit
- m
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.
Soot mass calculated A7_PQ35_SOOT_MASS_CALCConfirmed
- Request
22 11 4F - Service 22
DID 114F - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2019, 2021 to 2026
Example reply from a 2020 Audi A7.
Bits 0 to 15 of the reply, 16 bits.
0x3E08 = 15880 → (15880 ÷ 100) = 158.8
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.
Soot mass measured A7_PQ35_SOOT_MASS_MEASConfirmed
- Request
22 11 4E - Service 22
DID 114E - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0039 = 57 → (57 ÷ 100) = 0.57
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Engine › EGR
High press EGR closing v2 A7_PQ35_HIGH_P_EGR_CLOSING_VAR_2Confirmed
- Request
22 F4 2C - Service 22
DID F42C - Module
7E0 → 7E8 - Every
1 s - Testing for 2010, 2013 to 2026
Example reply from a 2012 Audi A7.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x15 = 21 → 21 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.
Engine › Internal
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2020.
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2020.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2020.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2020. Supported for 2021.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2012. Supported for 2016.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2020. Supported for 2021.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8196)- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2012. Supported for 2016.