Bentley Bentayga

Control parameters

The Bentley Bentayga has 44 control parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Absolute pedal position, drive BENTLEY_APP_D

  • Request22 F4 49
  • Service 22DID F449
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute pedal position, drive BENTLEY_APP_D

  • Request22 F4 49
  • Service 22DID F449
  • Module746 → 7B0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position BENTLEY_APP_PE

  • Request22 F4 49
  • Service 22DID F449
  • Module7E6
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position 1 BENTLEY_APP1

  • Request22 F4 49
  • Service 22DID F449
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal position 2 BENTLEY_APP2

  • Request22 F4 4A
  • Service 22DID F44A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Accelerator pedal release detection threshold voltage BENTLEY_APP_REDUCE_V

  • Request22 10 29
  • Service 22DID 1029
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2015 to 2026.

Brake BENTLEY_BRAKE_PRESSED

  • Request22 08 05
  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Brake booster low pressure, actual BENTLEY_BRAKE_BOOSTER_LOW_P_ACT

  • Request22 14 90
  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 39063 ÷ 1000000)
Range
0 to 2559.9937
Unit
Raw value

In testing for 2015 to 2026.

Brake booster pressure BENTLEY_BRAKE_BOOSTER_P

  • Request22 11 CF
  • Service 22DID 11CF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 500000)
Range
0 to 2559
Unit
Raw value

In testing for 2015 to 2026.

Brake booster pressure BENTLEY_BRAKE_BOOSTER_P_V2

  • Request22 20 05
  • Service 22DID 2005
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 bar
Unit
bar

In testing for 2015 to 2026.

Brake booster pressure BENTLEY_BRAKE_BST_P

  • Request22 20 05
  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 bar
Unit
bar

In testing for 2015 to 2026.

Brake booster pressure BENTLEY_PQ35_BRAKE_BOOSTER_P

  • Request22 20 05
  • Service 22DID 2005
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.08291753)
Range
0 to 5434
Unit
Raw value

In testing for 2015 to 2026.

Brake booster raw pressure BENTLEY_BRAKE_BOOSTER_RAW_P

  • Request22 11 D1
  • Service 22DID 11D1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2015 to 2026.

Brake booster, actual vacuum BENTLEY_BRAKE_BOOSTER_ACT

  • Request22 14 90
  • Service 22DID 1490
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 25)
Range
-1310 to 1310
Unit
Raw value

In testing for 2015 to 2026.

Brake light BENTLEY_BRAKE_LIGHT_ON

  • Request22 08 05
  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Brake light reading valid? BENTLEY_BRAKE_LIGHT_ON_VALID

  • Request22 08 05
  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2015 to 2026.

Brake pedal position BENTLEY_BRAKE_PEDAL_POS

  • Request22 10 5D
  • Service 22DID 105D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12207 ÷ 1000000)
Range
0 to 100 %
Unit
%

In testing for 2015 to 2026.

Brake pressure BENTLEY_BRAKE_P

  • Request22 2B 21
  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 152999 ÷ 10000000 − 42.503)
Range
-543.8501 to 458.8288 bar
Unit
bar

In testing for 2015 to 2026.

Brake pressure BENTLEY_BRAKE_P_7E0

  • Request22 18 D0
  • Service 22DID 18D0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Brake pressure BENTLEY_BRAKE_P_7E0_V2

  • Request22 19 5D
  • Service 22DID 195D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2015 to 2026.

Brake pressure BENTLEY_BRAKE_P_V2

  • Request22 10 5C
  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 bar
Unit
bar

In testing for 2015 to 2026.

Brake pressure BENTLEY_BRAKE_PRES

  • Request22 10 5C
  • Service 22DID 105C
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2015 to 2026.

Brake pressure BENTLEY_MQB_TCM_BRAKE_P

  • Request22 38 03
  • Service 22DID 3803
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 bar
Unit
bar

In testing for 2015 to 2026.

Brake pressure BENTLEY_PQ35_BRAKE_P

  • Request22 18 D0
  • Service 22DID 18D0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2015 to 2026.

Brake pressure reading valid? BENTLEY_BRAKE_PRESSED_VALID

  • Request22 08 05
  • Service 22DID 0805
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2015 to 2026.

Brake system vacuum pump active BENTLEY_BRAKE_SYSTEM_VACUUM

  • Request22 39 5E
  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2015 to 2026.

Brake vacuum pump BENTLEY_ENG_BRAKE_PUMP

  • Request22 39 5E
  • Service 22DID 395E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Directional stability control active BENTLEY_CSS_ACT

  • Request22 18 B6
  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Directional stability control last activation distance BENTLEY_CSS_ODO_LAST

  • Request22 18 B6
  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 31 of the reply, 24 bits.

Formula
val
Range
0 to 1 km
Unit
km

In testing for 2015 to 2026.

Directional stability control steering torque BENTLEY_CSS_STR_TRQ

  • Request22 18 B6
  • Service 22DID 18B6
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 1 N·m
Unit
N·m

In testing for 2015 to 2026.

Downshift point adaptation voltage BENTLEY_DOWNSHIFT_ADAPT_V

  • Request22 10 28
  • Service 22DID 1028
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2015 to 2026.

Electronic differential lock: front left brake temperature BENTLEY_EDL_FR_L_BRAKE_T

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 23 of the reply, 16 bits. The value is signed.

Formula
(val × 0.5)
Range
-20 to 300 °C
Unit
°C

In testing for 2015 to 2026.

Electronic differential lock: front right brake temperature BENTLEY_EDL_FR_R_BRAKE_T

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits. The value is signed.

Formula
(val × 0.5)
Range
-20 to 300 °C
Unit
°C

In testing for 2015 to 2026.

Electronic differential lock: rear left brake temperature BENTLEY_EDL_RR_L_BRAKE_T

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed.

Formula
(val × 0.5)
Range
-20 to 300 °C
Unit
°C

In testing for 2015 to 2026.

Electronic differential lock: rear right brake temperature BENTLEY_EDL_RR_R_BRAKE_T

  • Request22 18 0C
  • Service 22DID 180C
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
(val × 0.5)
Range
-20 to 300 °C
Unit
°C

In testing for 2015 to 2026.

Hill descent control active BENTLEY_HDC_ACT

  • Request22 18 08
  • Service 22DID 1808
  • Module713 → 77D
  • Every5 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2015 to 2026.

Hill descent control incline angle BENTLEY_HDC_INC

  • Request22 18 08
  • Service 22DID 1808
  • Module713 → 77D
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2015 to 2026.

Parking brake, air gap - left BENTLEY_PARKING_BRAKE_AIR

  • Request22 00 05
  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 mm
Unit
mm

In testing for 2015 to 2026.

Parking brake, air gap - right BENTLEY_PARKING_BRAKE_AIR_GAP

  • Request22 00 05
  • Service 22DID 0005
  • Module752 → 7BC
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 mm
Unit
mm

In testing for 2015 to 2026.

Pressure in brake servo unit BENTLEY_P_BRAKE_SERVO_UNIT

  • Request22 20 05
  • Service 22DID 2005
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375
Unit
Raw value

In testing for 2015 to 2026.

Requested brake torque, auxiliary system BENTLEY_REQ_BRAKE_TQ

  • Request22 16 10
  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2015 to 2026.

Steering wheel angle BENTLEY_STEER_ANGLE

Positive is rotated to the left, negative is rotated to the right.

  • Request22 2B 29
  • Service 22DID 2B29
  • Module713 → 77D
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.768 to 32.767 rad
Unit
rad

In testing for 2015 to 2026.

Steering wheel angle BENTLEY_STEER_ANGLE_V2

  • Request22 03 46
  • Service 22DID 0346
  • ModuleFC00 → FE0076
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 °
Unit
°

In testing for 2015 to 2026.

Control › Pedals

Accelerator pedal position sensor 1 BENTLEY_APP_POS1

  • Request22 20 61
  • Service 22DID 2061
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65 V
Unit
V

In testing for 2015 to 2026.

Accelerator pedal position sensor 2 BENTLEY_APP_POS2

  • Request22 20 62
  • Service 22DID 2062
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65 V
Unit
V

In testing for 2015 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.