Engine parameters
The Chevrolet Corvette has 101 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
1-2 shift error CORVETTE_1_2_SHIFT_ERROR
- Request
22 19 97 - Service 22
DID 1997 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 1988 to 2019.
1-2 shift time CORVETTE_1_2_SHIFT_TIME
- Request
22 19 93 - Service 22
DID 1993 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 1988 to 2019.
2-3 shift error CORVETTE_2_3_SHIFT_ERROR
- Request
22 19 98 - Service 22
DID 1998 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 1988 to 2019.
2-3 shift time CORVETTE_2_3_SHIFT_TIME
- Request
22 19 94 - Service 22
DID 1994 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 1988 to 2019.
3-4 shift error CORVETTE_3_4_SHIFT_ERROR
- Request
22 19 99 - Service 22
DID 1999 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 1988 to 2019.
3-4 shift time CORVETTE_3_4_SHIFT_TIME
- Request
22 19 95 - Service 22
DID 1995 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 1988 to 2019.
Air conditioning high side pressure CORVETTE_AC_HIGH_SIDE_P
- Request
22 15 64 - Service 22
DID 1564 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2.02)- Range
- 0 to 515.1 psi
- Unit
- psi
In testing for 1988 to 2019.
Air filter life remaining CORVETTE_AIRFILT_LIFEConfirmed
- Request
22 36 A7 - Service 22
DID 36A7 - Module
DA11 - Every
30 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Air filter life remaining CORVETTE_AIRFILT_LIFE_7E0
- Request
22 36 A7 - Service 22
DID 36A7 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2019.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.
Air/fuel ratio, commanded CORVETTE_AIR_FUEL_RAT_CMD
- Request
22 11 9E - Service 22
DID 119E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Number
In testing for 1988 to 2019.
Balance rate, cylinder 1 CORVETTE_BALANCE_RATE_CYL_1
- Request
22 16 2F - Service 22
DID 162F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 1988 to 2019.
Balance rate, cylinder 2 CORVETTE_BALANCE_RATE_CYL_2
- Request
22 16 30 - Service 22
DID 1630 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 1988 to 2019.
Balance rate, cylinder 3 CORVETTE_BALANCE_RATE_CYL_3
- Request
22 16 31 - Service 22
DID 1631 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 1988 to 2019.
Balance rate, cylinder 4 CORVETTE_BALANCE_RATE_CYL_4
- Request
22 16 32 - Service 22
DID 1632 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 1988 to 2019.
Balance rate, cylinder 5 CORVETTE_BALANCE_RATE_CYL_5
- Request
22 16 33 - Service 22
DID 1633 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 1988 to 2019.
Balance rate, cylinder 6 CORVETTE_BALANCE_RATE_CYL_6
- Request
22 16 34 - Service 22
DID 1634 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 1988 to 2019.
Balance rate, cylinder 7 CORVETTE_BALANCE_RATE_CYL_7
- Request
22 16 35 - Service 22
DID 1635 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 1988 to 2019.
Balance rate, cylinder 8 CORVETTE_BALANCE_RATE_CYL_8
- Request
22 16 36 - Service 22
DID 1636 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 512)- Range
- -512 to 511
- Unit
- Number
In testing for 1988 to 2019.
Barometric pressure, V8 CORVETTE_BAROMETRIC_P_V8
- Request
22 11 9D - Service 22
DID 119D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 1988 to 2019.
Boost pressure, actual CORVETTE_BP_ACTConfirmed
- Request
22 20 E3 - Service 22
DID 20E3 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Boost pressure, actual CORVETTE_BP_ACT_7E0
- Request
22 20 E3 - Service 22
DID 20E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 1988 to 2019.
Boost pressure, desired CORVETTE_BP_DES
- Request
22 32 8A - Service 22
DID 328A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
In testing for 1988 to 2019.
Brake pressure CORVETTE_BPConfirmed
- Request
22 4A 7C - Service 22
DID 4A7C - Module
DA28 - Every
250 ms - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val × 100 − 1000)- Range
- -13800 to 11700 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.
Calculated engine oil pressure CORVETTE_EOP_CALC
- Request
22 1C 1B - Service 22
DID 1C1B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 1988 to 2019.
Calculated engine oil temperature CORVETTE_EOT_CALC
Pelican can show this parameter as the engine oil temperature.
- Request
22 11 54 - Service 22
DID 1154 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2019.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2024 to 2025. Supported for 2020 to 2021, 2023.
Cooling fan command CORVETTE_COOLING_FAN_CMD
- Request
22 38 12 - Service 22
DID 3812 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2019.
Cooling fan motor command CORVETTE_COOLING_FAN_MOTOR_CMD
- Request
22 13 AF - Service 22
DID 13AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2019.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.
Engine oil absolute pressure CORVETTE_EOP_ABS
- Request
22 23 44 - Service 22
DID 2344 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 1988 to 2019.
Engine oil absolute pressure sensor CORVETTE_EO_APConfirmed
- Request
22 23 44 - Service 22
DID 2344 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Engine oil life remaining CORVETTE_EO_LIFE_REMAINING
- Request
22 4D C0 - Service 22
DID 4DC0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2019.
Engine oil life remaining CORVETTE_EOLConfirmed
- Request
22 4D C0 - Service 22
DID 4DC0 - Module
DA11 - Every
30 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Engine oil pressure CORVETTE_EOP
- Request
22 23 45 - Service 22
DID 2345 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 1988 to 2019.
Engine oil pressure CORVETTE_EOP_DA11
- Request
22 14 70 - Service 22
DID 1470 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 1988 to 2019.
Engine oil pressure CORVETTE_EOP_DA11_2
- Request
22 14 70 - Service 22
DID 1470 - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 400 ÷ 100)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2020 to 2026.
Engine oil pressure 2 CORVETTE_EOP_2
Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.
- Request
22 11 5C - Service 22
DID 115C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3 ÷ 5 − 21.6)- Range
- -21.6 to 131.39 psi
- Unit
- psi
In testing for 1988 to 2019.
Engine oil pressure control solenoid valve command CORVETTE_EOP_CTRL_SOLENOID_VALVE_CMD
- Request
22 33 18 - Service 22
DID 3318 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2019.
Engine oil pressure, actual CORVETTE_EOP_ACTConfirmed
- Request
22 23 45 - Service 22
DID 2345 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Engine oil temperature CORVETTE_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 15 3E - Service 22
DID 153E - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Engine oil temperature CORVETTE_EOT_7E0
Pelican can show this parameter as the engine oil temperature.
- Request
22 00 5C - Service 22
DID 005C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2019.
Engine oil temperature CORVETTE_EOT_DA11
- Request
22 15 3E - Service 22
DID 153E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 215 °C
- Unit
- °C
In testing for 1988 to 2019.
Engine oil temperature CORVETTE_EOT_DA11_2_2
Pelican can show this parameter as the engine oil temperature.
- Request
22 00 5C - Service 22
DID 005C - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2020 to 2026.
Engine torque CORVETTE_ENG_TQ
- Request
22 19 DE - Service 22
DID 19DE - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 2019.
Engine torque CORVETTE_ENG_TQ_7E0
- Request
22 20 3F - Service 22
DID 203F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 N·m
- Unit
- N·m
In testing for 1988 to 2019.
Evaporative emissions purge CORVETTE_EVAPORATIVE
- Request
22 11 70 - Service 22
DID 1170 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2019.
Heated oxygen sensor CORVETTE_HEATED_OXYGEN_SENS
- Request
22 11 45 - Service 22
DID 1145 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mV
- Unit
- mV
In testing for 1988 to 2019.
Idle air control position CORVETTE_IDLE_AIR_CTRL_POS
- Request
22 11 72 - Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Injector duty cycle bank 1 CORVETTE_INJECTOR_DUTY_CYCLE_BANK_1
- Request
22 12 C3 - Service 22
DID 12C3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 150 ÷ 10000)- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 1988 to 2019.
Injector duty cycle bank 2 CORVETTE_INJECTOR_DUTY_CYCLE_BANK_2
- Request
22 12 C4 - Service 22
DID 12C4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 150 ÷ 10000)- Range
- 0 to 983.025 ms
- Unit
- ms
In testing for 1988 to 2019.
Injector pulse width, cylinder 1 CORVETTE_INJ_WIDTH_CYL_1
- Request
22 11 93 - Service 22
DID 1193 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 65.535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 1988 to 2019.
Injector pulse width, cylinder 7 CORVETTE_INJ_WIDTH_CYL_7
- Request
22 11 99 - Service 22
DID 1199 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 65.535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 1988 to 2019.
Injector pulse width, cylinder 8 CORVETTE_INJ_WIDTH_CYL_8
- Request
22 12 9A - Service 22
DID 129A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 65.535)- Range
- 0 to 1000 ms
- Unit
- ms
In testing for 1988 to 2019.
Intake air temperature 2 CORVETTE_IAT_2
- Request
22 15 38 - Service 22
DID 1538 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2019.
Knock retard CORVETTE_KNOCK_RETARD
- Request
22 11 A6 - Service 22
DID 11A6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 22 ÷ 100)- Range
- 0 to 56.1 °
- Unit
- °
In testing for 1988 to 2019.
Knock retard, alternate CORVETTE_KNOCK_RETARD_ALT
- Request
22 12 5D - Service 22
DID 125D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °
- Unit
- °
In testing for 1988 to 2019.
Knock sensor active counter CORVETTE_KNOCK_SENS_ACTIVE
- Request
22 12 5E - Service 22
DID 125E - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Last shift time CORVETTE_LAST_SHIFT_TIME
- Request
22 19 92 - Service 22
DID 1992 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.375 s
- Unit
- s
In testing for 1988 to 2019.
Mass airflow sensor CORVETTE_MAFConfirmed
- Request
22 00 10 - Service 22
DID 0010 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Mass airflow sensor CORVETTE_MAF_7E0
- Request
22 00 10 - Service 22
DID 0010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 1988 to 2019.
Misfire current, cylinder 7 CORVETTE_MIS_CURRENT_7
- Request
22 11 EC - Service 22
DID 11EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Misfire current, cylinder 8 CORVETTE_MIS_CURRENT_8
- Request
22 11 ED - Service 22
DID 11ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Misfire history, cylinder 1 CORVETTE_MIS_HISTORY_1
- Request
22 12 01 - Service 22
DID 1201 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019.
Misfire history, cylinder 2 CORVETTE_MIS_HISTORY_2
- Request
22 12 02 - Service 22
DID 1202 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019.
Misfire history, cylinder 3 CORVETTE_MIS_HISTORY_3
- Request
22 12 03 - Service 22
DID 1203 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019.
Misfire history, cylinder 4 CORVETTE_MIS_HISTORY_4
- Request
22 12 04 - Service 22
DID 1204 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019.
Misfire history, cylinder 5 CORVETTE_MIS_HISTORY_5
- Request
22 11 F8 - Service 22
DID 11F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019.
Misfire history, cylinder 6 CORVETTE_MIS_HISTORY_6
- Request
22 11 F9 - Service 22
DID 11F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019.
Misfire history, cylinder 7 CORVETTE_MIS_HISTORY_7
- Request
22 11 FA - Service 22
DID 11FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019.
Misfire history, cylinder 8 CORVETTE_MIS_HISTORY_8
- Request
22 11 FB - Service 22
DID 11FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2019.
Misfires, current, cylinder 1 CORVETTE_MIS_1Confirmed
- Request
22 12 06 - Service 22
DID 1206 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Misfires, current, cylinder 1 CORVETTE_MISFIRES_C1_CUR
- Request
22 12 06 - Service 22
DID 1206 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Misfires, current, cylinder 2 CORVETTE_MIS_2Confirmed
- Request
22 12 05 - Service 22
DID 1205 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Misfires, current, cylinder 2 CORVETTE_MISFIRES_C2_CUR
- Request
22 12 05 - Service 22
DID 1205 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Misfires, current, cylinder 3 CORVETTE_MIS_3Confirmed
- Request
22 12 07 - Service 22
DID 1207 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Misfires, current, cylinder 3 CORVETTE_MISFIRES_C3_CUR
- Request
22 12 07 - Service 22
DID 1207 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Misfires, current, cylinder 4 CORVETTE_MIS_4Confirmed
- Request
22 12 08 - Service 22
DID 1208 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Misfires, current, cylinder 4 CORVETTE_MISFIRES_C4_CUR
- Request
22 12 08 - Service 22
DID 1208 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Misfires, current, cylinder 5 CORVETTE_MIS_5Confirmed
- Request
22 11 EA - Service 22
DID 11EA - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Misfires, current, cylinder 5 CORVETTE_MISFIRES_C5_CUR
- Request
22 11 EA - Service 22
DID 11EA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Misfires, current, cylinder 6 CORVETTE_MIS_6Confirmed
- Request
22 11 EB - Service 22
DID 11EB - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Misfires, current, cylinder 6 CORVETTE_MISFIRES_C6_CUR
- Request
22 11 EB - Service 22
DID 11EB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Misfires, current, cylinder 7 CORVETTE_MISFIRES_C7_CUR
- Request
22 11 EC - Service 22
DID 11EC - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Misfires, current, cylinder 8 CORVETTE_MISFIRES_C8_CUR
- Request
22 11 ED - Service 22
DID 11ED - Module
DA11 → 2AF111 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2020 to 2026.
Outside air temperature CORVETTE_AAT
- Request
22 11 61 - Service 22
DID 1161 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2019.
Particulate filter pressure CORVETTE_DPF_PRESSConfirmed
- Request
22 34 D8 - Service 22
DID 34D8 - Module
DA11 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 10000)- Range
- 0 to 655.35 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Pressure control solenoid current, actual CORVETTE_P_CTRL_SOLENOID_ACT
- Request
22 19 9E - Service 22
DID 199E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2019.
Pressure control solenoid current, reference CORVETTE_P_CTRL_SOLENOID
- Request
22 19 9F - Service 22
DID 199F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1988 to 2019.
Remaining oil life CORVETTE_REMAINING_OIL_LIFE
- Request
22 11 9F - Service 22
DID 119F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2019.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023.
Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 08 - Service 01
PID 08 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2025. Supported for 2006 to 2007, 2012, 2015, 2020 to 2021, 2023 to 2024.
Total knock retard CORVETTE_TOTAL_KNOCK_RETARD
- Request
22 12 D9 - Service 22
DID 12D9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 45 ÷ 100)- Range
- 0 to 114.75 °
- Unit
- °
In testing for 1988 to 2019.
Total misfire CORVETTE_TOTAL_MISFIRE
- Request
22 12 00 - Service 22
DID 1200 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2019.
Transmission fluid temperature CORVETTE_TFTConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 19 40 - Service 22
DID 1940 - Module
DA18 - Every
1 s - Testing for 1988 to 2023, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- 0 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. In testing for 1988 to 2014, 2016 to 2022, 2026. Not supported for 2015, 2023.
Transmission fluid temperature, variant 1 CORVETTE_ATF_T_VAR_1
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 19 40 - Service 22
DID 1940 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2019.
Transmission fluid temperature, variant 3 CORVETTE_ATF_T_VAR_3
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 19 40 - Service 22
DID 1940 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2019.
Transmission fluid temperature, variant 8 CORVETTE_ATF_T_VAR_8
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 28 0D - Service 22
DID 280D - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2019.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2024 to 2025. Supported for 2020.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2024 to 2025. Supported for 2020.