Battery parameters
The Chevrolet Malibu has 4 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Charge air cooler temperature sensor 1 MALIBU_CHARGE_AIR_COOLER_T_SNS_1
- Request
22 30 AD - Service 22
DID 30AD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2016, 2018 to 2024. Not supported for 2017.
Charge air cooler temperature sensor 2 MALIBU_CHARGE_AIR_COOLER_T_SNS_2
- Request
22 30 AE - Service 22
DID 30AE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2016, 2018 to 2024. Not supported for 2017.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2016 to 2017, 2022 to 2023. Supported for 2013, 2015, 2018 to 2021, 2024.
Ignition 1 voltage MALIBU_IGN_1_VConfirmed
- Request
22 11 41 - Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing for 1997 to 2016, 2018 to 2024
Example reply from a 2017 Chevrolet Malibu.
Bits 0 to 7 of the reply, 8 bits.
0x89 = 137 → (137 ÷ 10) = 13.7 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2017. In testing for 1997 to 2016, 2018 to 2024.