Citroën Basalt

Engine parameters

The Citroën Basalt has 355 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

5V power supply state number 1 CITROEN_5V_POWER_SUP_ST_1

  • Request22 D4 23
  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

5V power supply state number 1 CITROEN_5V_POWER_SUP_ST_1

  • Request22 D4 23
  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

5V power supply state number 2 CITROEN_5V_POWER_SUP_ST_2

  • Request22 D4 24
  • Service 22DID D424
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

5V power supply state number 3 CITROEN_5V_POWER_SUP_ST_3

  • Request22 D4 25
  • Service 22DID D425
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

5V power supply state number 4 CITROEN_5V_POWER_SUP_ST_4

  • Request22 D4 26
  • Service 22DID D426
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

12V network allowed stop CITROEN_12V_NETWORK_ALLOWED

  • Request22 D7 4C
  • Service 22DID D74C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Activation count, brake electromagnetic valve B1 CITROEN_NUM_ACTIVATIONS_B1

  • Request22 D7 45
  • Service 22DID D745
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2024 to 2026.

Activation count, line pressure control solenoid CITROEN_NUM_LINE_P_CTRL

  • Request22 D7 51
  • Service 22DID D751
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2024 to 2026.

Activation count, the electromagnetic valve of brake B2 CITROEN_NUM_ACTIVATIONS_B2

  • Request22 D7 5A
  • Service 22DID D75A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2024 to 2026.

Actual oil pressure CITROEN_ACT_OIL_P

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 bar
Unit
bar

In testing for 2024 to 2026.

Additional heater control 1 CITROEN_ADDITIONAL_HEATER_1

  • Request22 D4 16
  • Service 22DID D416
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

AFT DPF oulet pressure sensor CITROEN_AFT_DPF_OULET_P_SENS

  • Request22 A0 0A
  • Service 22DID A00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 2000)
Range
0 to 294 psi
Unit
psi

In testing for 2024 to 2026.

Air conditioning CITROEN_AC

  • Request22 D4 AF
  • Service 22DID D4AF
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Air conditioning compressor current CITROEN_AC_COMP_CURRENT

  • Request22 D4 1C
  • Service 22DID D41C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375
Unit
Number

In testing for 2024 to 2026.

Air conditioning high side pressure CITROEN_AC_HIGH_SIDE_P

  • Request22 03 29
  • Service 22DID 0329
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 14)
Range
0 to 3570 kPa
Unit
kPa

In testing for 2024 to 2026.

Air conditioning high side pressure CITROEN_AC_HIGH_SIDE_P_7E0

  • Request21 A7
  • Service 21PID A7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 55)
Range
0 to 1191 psi
Unit
psi

In testing for 2024 to 2026.

Air conditioning high side pressure CITROEN_AC_HIGH_SIDE_P_V2

  • Request22 D8 FF
  • Service 22DID D8FF
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 bar
Unit
bar

In testing for 2024 to 2026.

Air conditioning pressure CITROEN_AC_P

  • Request22 D4 21
  • Service 22DID D421
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2024 to 2026.

Air conditioning refrigerant pressure CITROEN_AC_REFRIGERANT_P

  • Request22 40 01
  • Service 22DID 4001
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 bar
Unit
bar

In testing for 2024 to 2026.

Air doser first electronic loading CITROEN_AIR_DOSER_FIRST

  • Request22 D5 3B
  • Service 22DID D53B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Air flow CITROEN_AIR_FLOW

  • Request22 D4 89
  • Service 22DID D489
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2024 to 2026.

Air flow target CITROEN_AIR_FLOW_TGT

  • Request22 D4 8E
  • Service 22DID D48E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2024 to 2026.

Air heater core temperature CITROEN_AIRHEATER_CORE_T

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Air heater current CITROEN_AIRHEATER_CURRENT

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 A
Unit
A

In testing for 2024 to 2026.

Air heater power consumption CITROEN_AIRHEATER_POWER_CONS

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Air metering valve duty cycle CITROEN_AIR_METERING_VLV

  • Request22 D4 61
  • Service 22DID D461
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2024 to 2026.

Air metering valve position CITROEN_AIR_METERING_VLV_POS

  • Request22 D5 4F
  • Service 22DID D54F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2024 to 2026.

Air metering valve, target position CITROEN_AIR_METERING_VLV_TGT

  • Request22 D4 60
  • Service 22DID D460
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2024 to 2026.

Air temperature by air flow meter CITROEN_AIR_T_AIR_FLOW_METER

  • Request22 D5 4E
  • Service 22DID D54E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2024 to 2026.

Alternator load value CITROEN_ALTERNATOR_LOAD

  • Request22 D4 A5
  • Service 22DID D4A5
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Ambient air temperature CITROEN_AAT_6A9

  • Request22 D5 52
  • Service 22DID D552
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2024 to 2026.

Ambient air temperature CITROEN_AAT_7E0

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023 °F
Unit
°F

In testing for 2024 to 2026.

Ambient temperature CITROEN_AAT

  • Request22 01 27
  • Service 22DID 0127
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 83)
Range
-83 to 376 °F
Unit
°F

In testing for 2024 to 2026.

Ambient temperature CITROEN_AAT_V2

  • Request22 D4 34
  • Service 22DID D434
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

ANTI START PROGRAMMING STATUS CITROEN_ANTI_START

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Assessment of thermal aging of the particulate filter CITROEN_ASSESSMENT_THERMAL

  • Request22 D5 32
  • Service 22DID D532
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 128)
Range
0 to 12799 %
Unit
%

In testing for 2024 to 2026.

AT main cylinder pressure CITROEN_MAIN_CYL_P

  • Request22 50 34
  • Service 22DID 5034
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513 bar
Unit
bar

In testing for 2024 to 2026.

Atmospheric pressure CITROEN_ATMOSPHERIC_P

  • Request22 D4 65
  • Service 22DID D465
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2024 to 2026.

Automatic restart request from body control module CITROEN_AUTOMATIC_RESTART_REQ_BSI

  • Request22 D7 0A
  • Service 22DID D70A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Automatic restart request from engine management computer CITROEN_AUTOMATIC_RESTART

  • Request22 D7 09
  • Service 22DID D709
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Automatic stop allowed by body control module CITROEN_AUTOMATIC_STOP

  • Request22 D7 03
  • Service 22DID D703
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Automatic stop allowed by power steering computer CITROEN_AUTOMATIC_STOP_ALLOWED_POWER_STEER

  • Request22 D7 05
  • Service 22DID D705
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Automatic transmission fluid temperature CITROEN_ATF_T_3RDGEN

  • Request21 18
  • Service 21PID 18
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 40)
Range
-40 to 983.9843 °F
Unit
°F

In testing for 2024 to 2026.

Auxiliary heater 2 control CITROEN_AUXILIARY_HEATER_2

  • Request22 D4 17
  • Service 22DID D417
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Average mileage for the last 10 regenerations CITROEN_AVG_MILEAGE_LAST_10

  • Request22 D5 25
  • Service 22DID D525
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 16)
Range
0 to 4095 km
Unit
km

In testing for 2024 to 2026.

Barometric pressure CITROEN_BAROMETRIC_P

  • Request22 01 09
  • Service 22DID 0109
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 2024 to 2026.

Boost air temperature CITROEN_BOOST_AIR_T

  • Request22 D4 11
  • Service 22DID D411
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2024 to 2026.

Boost pressure CITROEN_BOOST_P

  • Request22 A0 54
  • Service 22DID A054
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 435)
Range
0 to 150 psi
Unit
psi

In testing for 2024 to 2026.

Boost pressure estimate CITROEN_BOOST_P_ESTIMATE

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 441)
Range
0 to 148 psi
Unit
psi

In testing for 2024 to 2026.

Button state CITROEN_BUTTON_ST

  • Request22 D5 17
  • Service 22DID D517
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Cam crank difference CITROEN_CAM_CRANK_DIFF

  • Request22 05 9E
  • Service 22DID 059E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 2024 to 2026.

Camshaft/crankshaft position synchronization CITROEN_CAM_CRANK_POS

  • Request22 D4 18
  • Service 22DID D418
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Catalyst modeled temperature CITROEN_CAT_MODEL_T

  • Request22 01 2B
  • Service 22DID 012B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1000 °C
Unit
°C

In testing for 2024 to 2026.

CHANGE REPORT IN PROGRESS CITROEN_CHANGE_REPORT

  • Request22 D5 16
  • Service 22DID D516
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Closed loop soot load assessment of the diesel particulate filter CITROEN_CLOSED_LOOP_SOOT

  • Request22 D5 4B
  • Service 22DID D54B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.99 g/L
Unit
g/L

In testing for 2024 to 2026.

Combustion engine state CITROEN_ICE_ST

  • Request22 D7 09
  • Service 22DID D709
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Commanded oil pressure CITROEN_CMD_OIL_P

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 bar
Unit
bar

In testing for 2024 to 2026.

Commanded power CITROEN_CMD_POWER

  • Request22 19 97
  • Service 22DID 1997
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Computer lock CITROEN_COMPUTER_LOCK

  • Request22 DA DD
  • Service 22DID DADD
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Computer remote wake-up state CITROEN_COMPUTER_WAKE_UP_ST

  • Request22 D5 15
  • Service 22DID D515
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Computer restarts since memory erase CITROEN_CNT_NUM_RE

  • Request22 D4 D8
  • Service 22DID D4D8
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Computer temperature CITROEN_COMPUTER_T

  • Request22 D4 35
  • Service 22DID D435
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Control current of electromagnetic valve for changing the pressure in the brake system B2 CITROEN_CTRL_CURRENT_P_B2

  • Request22 D6 22
  • Service 22DID D622
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2024 to 2026.

Control current of the electromagnetic valve for changing the pressure in the brake system B1 CITROEN_CTRL_CURRENT_P_B1

  • Request22 D6 08
  • Service 22DID D608
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2024 to 2026.

Controlled air supply module CITROEN_CONTROLLED_AIR_SUP

  • Request22 D4 A0
  • Service 22DID D4A0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Coolant temperature CITROEN_ECT_6A8

Pelican can show this parameter as the engine coolant temperature.

  • Request22 D4 15
  • Service 22DID D415
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2024 to 2026.

Coolant temperature CITROEN_ECT_ECU

  • Request22 10 03
  • Service 22DID 1003
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2024 to 2026.

Coolant temperature CITROEN_ECT_V2

Pelican can show this parameter as the engine coolant temperature.

  • Request22 D8 FB
  • Service 22DID D8FB
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2024 to 2026.

Coolant temperature target CITROEN_ECT_TGT

  • Request22 D4 0D
  • Service 22DID D40D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Coolant temperature, corrected CITROEN_ECT_CORRECTED

  • Request22 D4 0A
  • Service 22DID D40A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Crankcase differential pressure CITROEN_CRANKCASE_DIFF_P

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

In testing for 2024 to 2026.

Crankcase pressure CITROEN_CRANKCASE_P

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1761)
Range
0 to 37.21 psi
Unit
psi

In testing for 2024 to 2026.

Cruise control, RW status CITROEN_CRUISE_CTRL_RW_STAT

  • Request22 D4 B0
  • Service 22DID D4B0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Cylinder 1 injector flow correction CITROEN_CYL_1_INJ_FLOW_CORR

  • Request22 D5 46
  • Service 22DID D546
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2024 to 2026.

Cylinder 2 injector flow correction CITROEN_CYL_2_INJ_FLOW_CORR

  • Request22 D5 47
  • Service 22DID D547
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2024 to 2026.

Cylinder 3 injector flow correction CITROEN_CYL_3_INJ_FLOW_CORR

  • Request22 D5 48
  • Service 22DID D548
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2024 to 2026.

Cylinder 4 injector flow correction CITROEN_CYL_4_INJ_FLOW_CORR

  • Request22 D5 49
  • Service 22DID D549
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2024 to 2026.

Date CITROEN_DATE

  • Request22 D4 CA
  • Service 22DID D4CA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 s
Unit
s

In testing for 2024 to 2026.

DEF dosing rate, gph CITROEN_DEF_DOSING_RATE_GPH

  • Request22 A1 29
  • Service 22DID A129
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2024 to 2026.

DEF level CITROEN_DEF_LEVEL

  • Request22 A0 06
  • Service 22DID A006
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

DEF quality CITROEN_DEF_QUALITY

  • Request22 A1 2B
  • Service 22DID A12B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

DEF temperature CITROEN_DEF_T

  • Request22 A0 04
  • Service 22DID A004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 %
Unit
%

In testing for 2024 to 2026.

Diesel fuel temperature CITROEN_FUEL_TEMP

  • Request22 19 00
  • Service 22DID 1900
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2024 to 2026.

Diesel particulate filter delta pressure CITROEN_DPF_DELTA_P

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 73 ÷ 500)
Range
0 to 37.2299 psi
Unit
psi

In testing for 2024 to 2026.

Diesel particulate filter differential pressure CITROEN_DPF_DIFF_P

  • Request22 18 E2
  • Service 22DID 18E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 32768)
Range
-32768 to -26214.5
Unit
Raw value

In testing for 2024 to 2026.

Diesel particulate filter differential pressure sensor signal deviation from reference value CITROEN_DPF_DIFF_P_SENS_SIG

  • Request22 D5 18
  • Service 22DID D518
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2024 to 2026.

Diesel particulate filter flow resistance CITROEN_DPF_FLOW_RES_V2

  • Request22 01 E2
  • Service 22DID 01E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10000)
Range
-3.2768 to 3.2767
Unit
Number

In testing for 2024 to 2026.

Diesel particulate filter inlet gas temperature CITROEN_INLET_DPF_GAS_T

  • Request22 18 DE
  • Service 22DID 18DE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.019608 − 40)
Range
-40 to 1245.0102 °C
Unit
°C

In testing for 2024 to 2026.

Diesel particulate filter regen active CITROEN_DPF_REGEN_ACTIVE_7E0

  • Request21 D8
  • Service 21PID D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 79 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Diesel particulate filter regeneration CITROEN_DPF_REGEN

  • Request21 48
  • Service 21PID 48
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 383 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Diesel particulate filter regeneration status CITROEN_DPF_REGEN_STAT

  • Request22 D5 21
  • Service 22DID D521
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Diesel particulate filter soot load CITROEN_DPF_SOOT_LOAD

  • Request22 01 E2
  • Service 22DID 01E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 g/L
Unit
g/L

In testing for 2024 to 2026.

Diesel particulate filter soot mass CITROEN_DPF_SOOT_MASS

  • Request22 18 E4
  • Service 22DID 18E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 763 ÷ 50000)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Differential pressure at particulate filter CITROEN_DIFF_P_PF

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2024 to 2026.

Drive motor coolant inlet temperature CITROEN_DRIVE_MOTOR_CLT_T

  • Request22 D8 D6
  • Service 22DID D8D6
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor coolant inlet temperature CITROEN_EMOTOR_CLT_INLET_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor coolant outlet temperature CITROEN_EMOTOR_CLT_OUTLET_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor inverter temperature 0 CITROEN_EMOTOR_INVERTER_T_0

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor inverter temperature 1 CITROEN_EMOTOR_INVERTER_T_1

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor inverter temperature 2 CITROEN_EMOTOR_INVERTER_T_2

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor inverter temperature model CITROEN_EMOTOR_INVERTER_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor PCB temperature CITROEN_EMOTOR_PCB_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor power CITROEN_DRIVE_MOTOR_POWER

  • Request22 D8 D9
  • Service 22DID D8D9
  • Module6A2 → 682
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100)
Range
-3276800 to 3276700 W
Unit
W

In testing for 2024 to 2026.

Drive motor rotor temperature CITROEN_EMOTOR_ROTOR_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor stator temperature CITROEN_DRIVE_MOTOR_STATOR_T

  • Request22 D8 CD
  • Service 22DID D8CD
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor stator temperature CITROEN_EMOTOR_STATOR_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Drive motor torque achieved CITROEN_EMOTOR_TQ_ACHIEVED

  • Request22 30 64
  • Service 22DID 3064
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2024 to 2026.

Drive motor torque limit CITROEN_EMOTOR_TQ_LIM

  • Request22 30 63
  • Service 22DID 3063
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2024 to 2026.

Drive motor torque, actual CITROEN_DRIVE_MOTOR_TQ_ACT

  • Request22 D8 D0
  • Service 22DID D8D0
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2024 to 2026.

Drive motor torque, commanded CITROEN_EMOTOR_TQ_CMD

  • Request22 30 64
  • Service 22DID 3064
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2024 to 2026.

Drive motor torque, desired CITROEN_DRIVE_MOTOR_TQ_DES

  • Request22 D8 80
  • Service 22DID D880
  • Module6A2 → 682
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 N·m
Unit
N·m

In testing for 2024 to 2026.

Driver presence CITROEN_DRIVER_PRESENCE

  • Request22 D7 23
  • Service 22DID D723
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Driver, requested torque value CITROEN_DRIVER_REQ_TQ

  • Request22 D5 07
  • Service 22DID D507
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2024 to 2026.

Economy mode off state CITROEN_ECO_MODE_OFF_ST

  • Request22 D7 24
  • Service 22DID D724
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Electric A/C compressor HV current CITROEN_EAC_HV_CURRENT

  • Request22 40 11
  • Service 22DID 4011
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 A
Unit
A

In testing for 2024 to 2026.

Electric cooling fan control CITROEN_GMV_ELEC_COOLING_FAN

  • Request22 D4 2F
  • Service 22DID D42F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Electric machine torque CITROEN_ELEC_MACHINE_TQ

  • Request22 DC B6
  • Service 22DID DCB6
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 1638.3)
Range
-1638 to 4915 N·m
Unit
N·m

In testing for 2024 to 2026.

Electric machine torque reduction CITROEN_ELEC_MACHINE_TQ_REDUCTION

  • Request22 DC 69
  • Service 22DID DC69
  • Module6A6 → 686
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2024 to 2026.

Energy accumulator state transfer CITROEN_ENERGY_ACCUMULATOR_ST

  • Request22 D7 55
  • Service 22DID D755
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Energy accumulator temperature limiter state CITROEN_ENERGY_ACCUMULATOR_T

  • Request22 D7 58
  • Service 22DID D758
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Engine control module status CITROEN_ENG_CTRL_MODULE_STAT

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Engine coolant temperature CITROEN_ECT

  • Request22 01 1D
  • Service 22DID 011D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2024 to 2026.

Engine coolant temperature CITROEN_ECT_6A9

  • Request22 D5 55
  • Service 22DID D555
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil degradation CITROEN_OIL_DEGRAD

  • Request22 38 13
  • Service 22DID 3813
  • ModuleDA10 → 10
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Engine oil dilution protection status CITROEN_ENG_OIL_DILUTION

  • Request22 D5 24
  • Service 22DID D524
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Engine oil pressure CITROEN_EOP

  • Request22 02 2A
  • Service 22DID 022A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 29 ÷ 50)
Range
0 to 147.8999 psi
Unit
psi

In testing for 2024 to 2026.

Engine oil temperature CITROEN_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549.94 to 3003.56 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature CITROEN_EOT_212D

Pelican can show this parameter as the engine oil temperature.

  • Request21 2D
  • Service 21PID 2D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 83)
Range
-83 to 376 °F
Unit
°F

In testing for 2024 to 2026.

Engine oil temperature CITROEN_EOT_21D2

Pelican can show this parameter as the engine oil temperature.

  • Request21 D2
  • Service 21PID D2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2024 to 2026.

Engine oil temperature CITROEN_EOT_V2

  • Request21 2D
  • Service 21PID 2D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2024 to 2026.

Engine operating mode CITROEN_ENG_OP_MODE

  • Request22 D5 53
  • Service 22DID D553
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8)
Range
0 to 8191 rpm
Unit
rpm

In testing for 2024 to 2026.

Engine operational status CITROEN_ENGINE_STATUS

  • Request22 10 02
  • Service 22DID 1002
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2024 to 2026.

Engine restart counter CITROEN_ENG_RESTART_CNT

  • Request22 D4 06
  • Service 22DID D406
  • Module6A9 → 689
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2024 to 2026.

Engine restart counter by stop and start function CITROEN_ENG_RESTART_CNT_STOP

  • Request22 D7 1B
  • Service 22DID D71B
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2024 to 2026.

Engine restart request sent by ESP computer CITROEN_ENG_RESTART_REQ_SENT

  • Request22 D7 0D
  • Service 22DID D70D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Engine RPM CITROEN_RPM

  • Request22 10 00
  • Service 22DID 1000
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 rpm
Unit
rpm

In testing for 2024 to 2026.

Engine stalls CITROEN_ENG_STALLS

  • Request22 D7 30
  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Engine start prohibition control, start lock CITROEN_ENG_START

  • Request22 D7 03
  • Service 22DID D703
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Engine stop time CITROEN_ENG_STOP_TIME

  • Request22 D4 77
  • Service 22DID D477
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

In testing for 2024 to 2026.

Engine temperature CITROEN_ENG_TEMEPRATURE

  • Request22 01 98
  • Service 22DID 0198
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2024 to 2026.

Engine torque CITROEN_ENG_TQ

  • Request21 C3
  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2024 to 2026.

Estimated soot removal time CITROEN_ESITMATED_SOOT

  • Request21 57
  • Service 21PID 57
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2024 to 2026.

Estimated torque of internal friction of the engine CITROEN_ESTIMATED_TQ

  • Request22 D4 E2
  • Service 22DID D4E2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 N·m
Unit
N·m

In testing for 2024 to 2026.

Evaluation of carbon content in engine oil CITROEN_EVALUATION_CARBON

  • Request22 D5 23
  • Service 22DID D523
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 32)
Range
0 to 7.96 %
Unit
%

In testing for 2024 to 2026.

Evaluation of the degree of dilution of motor oil CITROEN_EVALUATION_DEGREE

  • Request22 D5 1F
  • Service 22DID D51F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 %
Unit
%

In testing for 2024 to 2026.

Evaluation of the exhaust gas flow using the nox sensor CITROEN_EVALUATION_EXH_GAS

  • Request22 D5 42
  • Service 22DID D542
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val × 100)
Range
-214748364800 to 214748364700 L
Unit
L

In testing for 2024 to 2026.

Exhaust camshaft 1 to crankshaft offset CITROEN_EXH_CAM_1_OFFSET

  • Request22 06 1B
  • Service 22DID 061B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2024 to 2026.

Exhaust gas flow through the particulate filter CITROEN_EXH_GAS_FLOW_THROUGH

  • Request22 D5 33
  • Service 22DID D533
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 219.726593)
Range
0 to 14399782 L
Unit
L

In testing for 2024 to 2026.

Exhaust gas pressure at the outlet of the particulate filter CITROEN_EXH_GAS_P_OUTLET_PF

  • Request22 D5 44
  • Service 22DID D544
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 999.9999525)
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2024 to 2026.

Exhaust gas recirculation airflow control valve position CITROEN_EGR_AIRFLOW_CTRL_VLV

  • Request21 D7
  • Service 21PID D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 39 ÷ 5000)
Range
0 to 511 %
Unit
%

In testing for 2024 to 2026.

Exhaust gas recirculation cooler downstream temperature CITROEN_EGR_COOLER_T

  • Request22 39 17
  • Service 22DID 3917
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 900 °C
Unit
°C

In testing for 2024 to 2026.

Exhaust gas recirculation flow CITROEN_EGR_FLOW

  • Request21 D9
  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 kg/h
Unit
kg/h

In testing for 2024 to 2026.

Exhaust gas recirculation high limit electronic loading CITROEN_EGR_HIGH_LIM

  • Request22 D5 53
  • Service 22DID D553
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Exhaust gas recirculation low limit electronic loading CITROEN_EGR_LOW_LIM

  • Request22 D5 52
  • Service 22DID D552
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Exhaust gas recirculation orifice temperature CITROEN_EGR_ORIFICE_T

  • Request21 D9
  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val × 9 ÷ 20 + 32)
Range
0 to 29522 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas recirculation temperature CITROEN_EGR_T

  • Request22 A0 DC
  • Service 22DID A0DC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 9 ÷ 640)
Range
0 to 921 %
Unit
%

In testing for 2024 to 2026.

Exhaust gas recirculation valve duty cycle CITROEN_EGR_VLV_CTRL_SIG_RCO

  • Request22 D5 11
  • Service 22DID D511
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2024 to 2026.

Exhaust gas recirculation valve first electronic loading CITROEN_EGR_VLV_FIRST

  • Request22 D5 3A
  • Service 22DID D53A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Exhaust gas recirculation valve position CITROEN_EGR_VLV_POS

  • Request22 A0 DA
  • Service 22DID A0DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 %
Unit
%

In testing for 2024 to 2026.

Exhaust gas recirculation valve position CITROEN_EGR_VLV_POS_V2

  • Request22 D5 09
  • Service 22DID D509
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2024 to 2026.

Exhaust gas recirculation valve set position CITROEN_EGR_VLV_SET_POS

  • Request22 D5 10
  • Service 22DID D510
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2024 to 2026.

Exhaust gas recirculation valve, commanded position CITROEN_EGR_VLV_CMD_POSTIION

  • Request21 D9
  • Service 21PID D9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 + 32)
Range
0 to 543 %
Unit
%

In testing for 2024 to 2026.

Exhaust gas temperature 1 CITROEN_EXH_GAS_T_1

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 144 ÷ 5 + 32)
Range
0 to 7376 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 1 CITROEN_EXH_GAS_T_1_7E0

  • Request21 48
  • Service 21PID 48
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 1 – DOC inlet CITROEN_EXH_GAS_T_1_DOC

  • Request22 A0 BD
  • Service 22DID A0BD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 2 CITROEN_EXH_GAS_T_2

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 9 ÷ 80 + 32)
Range
0 to 7404 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 2 CITROEN_EXH_GAS_T_2_7E0

  • Request21 48
  • Service 21PID 48
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 2 – DOC outlet CITROEN_EXH_GAS_T_2_DOC

  • Request22 A0 C2
  • Service 22DID A0C2
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 3 CITROEN_EXH_GAS_T_3

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 9 ÷ 80 + 32)
Range
0 to 7404 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 3 – DPF outlet CITROEN_EXH_GAS_T_3_DPF

  • Request22 A0 C4
  • Service 22DID A0C4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 4 CITROEN_EXH_GAS_T_4

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val × 9 ÷ 80 + 32)
Range
0 to 7404 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 4, catalyst middle CITROEN_EXH_GAS_T_4_SCR_CAT

  • Request22 A0 C6
  • Service 22DID A0C6
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust gas temperature 5 – SCR CAT outlet CITROEN_EXH_GAS_T_5_SCR_CAT

  • Request22 A0 C8
  • Service 22DID A0C8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val + 32)
Range
-32736 to 32799 °F
Unit
°F

In testing for 2024 to 2026.

Exhaust temperature, downstream of exhaust manifold CITROEN_EXH_T_DN_EXH

  • Request22 01 7E
  • Service 22DID 017E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549.94 to 3003.56 °C
Unit
°C

In testing for 2024 to 2026.

Exhaust temperature, EGR cooler downstream CITROEN_EXH_T_EGR_COOLER_DN

  • Request22 01 7E
  • Service 22DID 017E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549.94 to 3003.56 °C
Unit
°C

In testing for 2024 to 2026.

Exhaust temperature, upstream of exhaust manifold CITROEN_EXH_T_UP_EXH

  • Request22 01 7E
  • Service 22DID 017E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.14)
Range
-3549.94 to 3003.56 °C
Unit
°C

In testing for 2024 to 2026.

Expected generator supplier identifier of the reversible generator CITROEN_EXPECTED_GEN

  • Request22 D7 89
  • Service 22DID D789
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Expected identifier of electronic power circuit of reversible generator generator CITROEN_EXPECTED_IDENTIFIER_ELECTRONIC

  • Request22 D7 88
  • Service 22DID D788
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Expected identifier of reversible generator CITROEN_EXPECTED_IDENTIFIER

  • Request22 D7 87
  • Service 22DID D787
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Fuel correction cylinder 1 CITROEN_FUEL_CORR_CYL1

  • Request22 38 00
  • Service 22DID 3800
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2024 to 2026.

Fuel correction cylinder 2 CITROEN_FUEL_CORR_CYL2

  • Request22 38 01
  • Service 22DID 3801
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2024 to 2026.

Fuel correction cylinder 3 CITROEN_FUEL_CORR_CYL3

  • Request22 38 02
  • Service 22DID 3802
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2024 to 2026.

Fuel correction cylinder 4 CITROEN_FUEL_CORR_CYL4

  • Request22 38 03
  • Service 22DID 3803
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-5 to 5 mg/stroke
Unit
mg/stroke

In testing for 2024 to 2026.

Fuel rail pressure commanded CITROEN_RAIL_PRESS_CMD

  • Request22 19 46
  • Service 22DID 1946
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3000 bar
Unit
bar

In testing for 2024 to 2026.

Fuel rail pressure measured CITROEN_RAIL_PRESS

  • Request22 19 47
  • Service 22DID 1947
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3000 bar
Unit
bar

In testing for 2024 to 2026.

FUGITIVE TRIP IN EMERGENCY MODE CITROEN_FUGITIVE_TRIP

  • Request22 D6 71
  • Service 22DID D671
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Generator mode CITROEN_GEN_MODE

  • Request22 D7 14
  • Service 22DID D714
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 75)
Range
0 to 19125 rpm
Unit
rpm

In testing for 2024 to 2026.

Generator shutdown CITROEN_GEN_SHUTDOWN

  • Request22 D7 5B
  • Service 22DID D75B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Glow plug plug set temperature CITROEN_PREHEATING_T

  • Request22 D5 0F
  • Service 22DID D50F
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2024 to 2026.

Glow plug relay status CITROEN_STAT_PRE_POST

  • Request22 D5 0D
  • Service 22DID D50D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

IAT post-intercooler CITROEN_IAT_TURBO

  • Request22 19 35
  • Service 22DID 1935
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2024 to 2026.

Identifier of the electronic power circuit of the reversible generator CITROEN_IDENTIFIER

  • Request22 D7 32
  • Service 22DID D732
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Identifier of the supplier of the reversible generator CITROEN_IDENTIFIER_SUPPLIER

  • Request22 D7 33
  • Service 22DID D733
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Immobilizer code programming status CITROEN_IMMOBILIZER_CODE

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Indicated engine torque CITROEN_INDICATED_ENG_TQ

  • Request22 D4 D2
  • Service 22DID D4D2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 N·m
Unit
N·m

In testing for 2024 to 2026.

Injection pulse, cylinder 1 CITROEN_INJ_CYL_1

  • Request22 02 34
  • Service 22DID 0234
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2024 to 2026.

Injection pulse, cylinder 2 CITROEN_INJ_CYL_2

  • Request22 02 35
  • Service 22DID 0235
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2024 to 2026.

Injection pulse, cylinder 3 CITROEN_INJ_CYL_3

  • Request22 02 36
  • Service 22DID 0236
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2024 to 2026.

Injection pulse, cylinder 4 CITROEN_INJ_CYL_4

  • Request22 02 37
  • Service 22DID 0237
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2024 to 2026.

Injector code 1 CITROEN_INJ_CODE_1

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 47 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2024 to 2026.

Injector code 2 CITROEN_INJ_CODE_2

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 72 to 111 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2024 to 2026.

Injector code 3 CITROEN_INJ_CODE_3

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 136 to 175 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2024 to 2026.

Injector code 4 CITROEN_INJ_CODE_4

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 200 to 239 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2024 to 2026.

Injector pulse width, cylinder 1 CITROEN_INJ_WIDTH_CYL_1

  • Request22 02 34
  • Service 22DID 0234
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2024 to 2026.

Injector pulse width, cylinder 2 CITROEN_INJ_WIDTH_CYL_2

  • Request22 02 35
  • Service 22DID 0235
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2024 to 2026.

Injector pulse width, cylinder 3 CITROEN_INJ_WIDTH_CYL_3

  • Request22 02 36
  • Service 22DID 0236
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2024 to 2026.

Injector pulse width, cylinder 4 CITROEN_INJ_WIDTH_CYL_4

  • Request22 02 37
  • Service 22DID 0237
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2024 to 2026.

Intake camshaft 1 to crankshaft offset CITROEN_INT_CAM_1_OFFSET

  • Request22 06 C2
  • Service 22DID 06C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °
Unit
°

In testing for 2024 to 2026.

Intake manifold air pressure CITROEN_MAP

  • Request22 01 74
  • Service 22DID 0174
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 2024 to 2026.

Intake manifold air temperature CITROEN_IAT_01FF

  • Request22 01 FF
  • Service 22DID 01FF
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2024 to 2026.

Intake manifold air temperature CITROEN_IAT_70B8

  • Request22 70 B8
  • Service 22DID 70B8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0198412698 − 40)
Range
-40 to 1260.2976 °C
Unit
°C

In testing for 2024 to 2026.

Intake manifold air temperature CITROEN_INT_MANIFOLD_AIR_T

  • Request22 19 35
  • Service 22DID 1935
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 40)
Range
-40 to 65495 °F
Unit
°F

In testing for 2024 to 2026.

Inverter temperature estimated CITROEN_INVERTER_T_ESTIMATED

  • Request22 DC 6A
  • Service 22DID DC6A
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Inverter temperature, commanded CITROEN_INVERTER_T_CMD

  • Request22 DC 04
  • Service 22DID DC04
  • Module6A6 → 686
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

In testing for 2024 to 2026.

Knock sensor 1 CITROEN_KNOCK_SENS_1

  • Request22 01 A9
  • Service 22DID 01A9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 2024 to 2026.

Knock sensor 2 CITROEN_KNOCK_SENS_2

  • Request22 01 AA
  • Service 22DID 01AA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 2024 to 2026.

Line pressure CITROEN_LINE_P

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 psi
Unit
psi

In testing for 2024 to 2026.

Line pressure duty cycle CITROEN_LINE_P_DUTY

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 655)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Line pressure solenoid valve control current CITROEN_SLT_LINE_P_VARIATION

  • Request22 D6 06
  • Service 22DID D606
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2024 to 2026.

Lock status CITROEN_LOCK_STAT

  • Request22 DA DD
  • Service 22DID DADD
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Long-term regeneration capability CITROEN_LONG_TERM_REGEN

  • Request22 D5 4D
  • Service 22DID D54D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Low side coolant temperature CITROEN_LOW_SIDE_ECT

  • Request22 12 C9
  • Service 22DID 12C9
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2024 to 2026.

M-Prop injection command CITROEN_MPROP_CMD

  • Request22 18 D0
  • Service 22DID 18D0
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Mass airflow sensor temperature CITROEN_MAF_TEMP

  • Request22 19 3F
  • Service 22DID 193F
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 100 − 40)
Range
-40 to 200 °C
Unit
°C

In testing for 2024 to 2026.

Mass of urea injected for thermal protection of urea injector CITROEN_MASS_UREA_INJECTED

  • Request22 D5 6B
  • Service 22DID D56B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50.00000112)
Range
0 to 1310 g
Unit
g

In testing for 2024 to 2026.

Maximum allowable torque CITROEN_MAX_ALLOWABLE_TQ

  • Request22 D5 06
  • Service 22DID D506
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2024 to 2026.

Measured current of electromagnetic valve for changing the pressure in the brake system B2 CITROEN_MEAS_CURRENT_P_B2

  • Request22 D6 23
  • Service 22DID D623
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2024 to 2026.

Measured current of the electromagnetic valve for changing the pressure in the brake system B1 CITROEN_MEAS_CURRENT_P_B1

  • Request22 D6 09
  • Service 22DID D609
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2024 to 2026.

Measured line pressure variation solenoid valve current CITROEN_MEAS_LINE_P

  • Request22 D6 07
  • Service 22DID D607
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2024 to 2026.

Mileage remaining before diesel particulate filter replacement CITROEN_MILEAGE_REMAINING

  • Request22 D5 30
  • Service 22DID D530
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 16)
Range
-524288 to 524272 km
Unit
km

In testing for 2024 to 2026.

Mileage since last diesel particulate filter replacement CITROEN_MILEAGE_SINCE_DPF

  • Request22 D5 31
  • Service 22DID D531
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8)
Range
0 to 524280 km
Unit
km

In testing for 2024 to 2026.

Mileage since last oil change CITROEN_MILEAGE_SINCE_OIL

  • Request22 D4 3F
  • Service 22DID D43F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2024 to 2026.

Minimum cell capacity CITROEN_MIN_CELL_CAP

  • Request22 D4 13
  • Service 22DID D413
  • Module6B4 → 694
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2024 to 2026.

Mixture enrichment measured by nox sensor at inlet CITROEN_MIXTURE_ENRICHMENT

  • Request22 D5 71
  • Service 22DID D571
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

In testing for 2024 to 2026.

Mixture enrichment measured by nox sensor at outlet CITROEN_MIXTURE_ENRICHMENT_MEAS

  • Request22 D5 5B
  • Service 22DID D55B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

In testing for 2024 to 2026.

Movement of controlled air supply module CITROEN_MOVEMENT_CONTROLLED

  • Request22 D4 EB
  • Service 22DID D4EB
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Multi-displacement system active CITROEN_MDS_ACTIVE

  • Request22 0E CA
  • Service 22DID 0ECA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Neutral position sensor status CITROEN_NEUTRAL_POS_SENS

  • Request22 D4 38
  • Service 22DID D438
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Nitrogen oxides at exhaust treatment intake CITROEN_AFTERTREATMENT_INT

  • Request22 A1 14
  • Service 22DID A114
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2024 to 2026.

Nitrogen oxides at exhaust treatment outlet CITROEN_AFTERTREATMENT

  • Request22 A1 1A
  • Service 22DID A11A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2024 to 2026.

Nox sensor heating control CITROEN_NOX_SENS_HEATING

  • Request22 D5 54
  • Service 22DID D554
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Nox sensor signal status at the inlet CITROEN_NOX_SENS_SIG_STAT_INLET

  • Request22 D5 72
  • Service 22DID D572
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Nox sensor signal status at the outlet CITROEN_NOX_SENS_SIG_STAT

  • Request22 D5 73
  • Service 22DID D573
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Nox system operating status CITROEN_NOX_SYSTEM_OP_STAT

  • Request22 D5 40
  • Service 22DID D540
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Number of engine stop information deletion cycles CITROEN_NUM_ENG_STOP

  • Request22 D7 30
  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Oil pressure CITROEN_OIL_P

  • Request22 D4 29
  • Service 22DID D429
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2024 to 2026.

Oil pressure reference value CITROEN_OIL_P_REFERENCE

  • Request22 D4 64
  • Service 22DID D464
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2024 to 2026.

Oil pressure regulation control CITROEN_OIL_P_REGULATION

  • Request22 D4 3B
  • Service 22DID D43B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2024 to 2026.

Oil temperature CITROEN_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request22 D4 7D
  • Service 22DID D47D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2024 to 2026.

Oil temperature CITROEN_OIL_TEMEPRATURE

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2024 to 2026.

Open loop soot load assessment of the diesel particulate filter CITROEN_OPEN_LOOP_SOOT_LOAD

  • Request22 D5 4A
  • Service 22DID D54A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1024)
Range
0 to 63.99 g/L
Unit
g/L

In testing for 2024 to 2026.

Outside air temperature CITROEN_AAT_6A8

  • Request22 D4 14
  • Service 22DID D414
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2024 to 2026.

Particulate filter differential pressure CITROEN_PF_DIFF_P

  • Request22 D5 20
  • Service 22DID D520
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2024 to 2026.

Particulate filter regeneration count CITROEN_DPF_REGENS_5089

  • Request22 50 89
  • Service 22DID 5089
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5
Unit
Number

In testing for 2024 to 2026.

Power consumed for heating the pipelines of the urea injection system CITROEN_POWER_CONSUMED

  • Request22 D5 80
  • Service 22DID D580
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 %
Unit
%

In testing for 2024 to 2026.

Power spent on heating the urea injection system pipes, percentage ratio CITROEN_POWER_SPENT_ON

  • Request22 D5 3C
  • Service 22DID D53C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 163.8399875)
Range
0 to 399 %
Unit
%

In testing for 2024 to 2026.

Powertrain condition CITROEN_POWERTRAIN_COND

  • Request22 D4 BA
  • Service 22DID D4BA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Preheating relay control CITROEN_PREHEATING_RELAY

  • Request22 D5 0C
  • Service 22DID D50C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2024 to 2026.

Presence of the identifier of the reversible generator CITROEN_PRESENCE_IDENTIFIER

  • Request22 D7 31
  • Service 22DID D731
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Pressure in the particulate filter CITROEN_P_PF

  • Request22 01 7B
  • Service 22DID 017B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2024 to 2026.

Pressure-based injection permission for urea solution CITROEN_P_BASED_INJ

  • Request22 D5 14
  • Service 22DID D514
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Problems detected while transmitting unlock code CITROEN_PROBLEMS_DETECTED

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Problems detected while transmitting unlock code CITROEN_PROBLEMS_DETECTED_WHILE

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Real engine torque CITROEN_REAL_ENG_TQ

  • Request22 D5 54
  • Service 22DID D554
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2024 to 2026.

Regen enable, on/off – alternative CITROEN_REGEN_ENABLE_ON_OFF

  • Request21 D8
  • Service 21PID D8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 95 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2024 to 2026.

Regeneration active CITROEN_DPF_REGEN_ACTIVE

  • Request22 50 AF
  • Service 22DID 50AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Number

In testing for 2024 to 2026.

Regeneration enable CITROEN_REGEN_ENABLE

  • Request22 D5 28
  • Service 22DID D528
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Remaining urea solution in the urea tank CITROEN_REMAINING_UREA

  • Request22 D5 17
  • Service 22DID D517
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 125 ÷ 128)
Range
0 to 63999
Unit
Raw value

In testing for 2024 to 2026.

Remote wake-up circuit status CITROEN_REMOTE_WAKE_UP

  • Request22 D7 05
  • Service 22DID D705
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Remote wake-up state CITROEN_REMOTE_WAKE_UP_ST

  • Request22 D7 08
  • Service 22DID D708
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Request to turn on the engine diagnostic indicator CITROEN_REQ_TURN_ON_ENG

  • Request22 D5 11
  • Service 22DID D511
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Requested value controlled thermostat CITROEN_REQ_CONTROLLED

  • Request22 D5 86
  • Service 22DID D586
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 81.92000625)
Range
-399 to 399 %
Unit
%

In testing for 2024 to 2026.

Restart request sent by power steering computer CITROEN_RESTART_REQ_SENT

  • Request22 D7 0C
  • Service 22DID D70C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Restart request sent by suspension computer CITROEN_RESTART_REQ_SENT_SUSPENSION

  • Request22 D7 0E
  • Service 22DID D70E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Return to engine start and restart control by starter CITROEN_RETURN_ENG_START

  • Request22 D7 64
  • Service 22DID D764
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Return to starter engine restart control CITROEN_RETURN_STARTER_ENG

  • Request22 D7 61
  • Service 22DID D761
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Reverse generator status CITROEN_REVERSE_GEN_STAT

  • Request22 D7 16
  • Service 22DID D716
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Reversible generator torque CITROEN_REVERSIBLE_GEN_TQ

  • Request22 D7 15
  • Service 22DID D715
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2024 to 2026.

Sensed oil pressure CITROEN_SENSED_OIL_P

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2024 to 2026.

Sensed pressure particulate filter downstream CITROEN_SENSED_P_PF_DN

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2024 to 2026.

Service network related engine restart request CITROEN_SERVICE_NETWORK

  • Request22 D7 4B
  • Service 22DID D74B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Short term knock retard CITROEN_SHORT_TERM_KNOCK

  • Request22 01 AE
  • Service 22DID 01AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 °
Unit
°

In testing for 2024 to 2026.

Short-term regeneration capability CITROEN_SHORT_TERM_REGEN

  • Request22 D5 4C
  • Service 22DID D54C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Simulated particulate mass, stored CITROEN_DPF_SIM_MASS

  • Request22 01 E2
  • Service 22DID 01E2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

In testing for 2024 to 2026.

Soot clogging level of diesel particulate filter CITROEN_SOOT_CLOGGING_LEVEL

  • Request22 D5 2F
  • Service 22DID D52F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10.24)
Range
0 to 6399 %
Unit
%

In testing for 2024 to 2026.

Soot load CITROEN_SOOT_LOAD

  • Request21 4D
  • Service 21PID 4D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 g
Unit
g

In testing for 2024 to 2026.

Soot load based on delta pressure CITROEN_SOOT_LOAD_BASED_ON_P

  • Request21 57
  • Service 21PID 57
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 100 + 32)
Range
0 to 34.55
Unit
Raw value

In testing for 2024 to 2026.

Soot mass flow in exhaust gas after combustion CITROEN_SOOT_MASS_FLOW_EXH

  • Request22 01 7A
  • Service 22DID 017A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 223 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 100)
Range
-21474836 to 21474836
Unit
Raw value

In testing for 2024 to 2026.

Soot mass load CITROEN_SOOT_MASS_LOAD

  • Request22 50 8D
  • Service 22DID 508D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 650)
Range
0 to 100.823 %
Unit
%

In testing for 2024 to 2026.

Specified volume of injected urea solution CITROEN_SPEC_VOLUME_INJECTED

  • Request22 D5 50
  • Service 22DID D550
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023
Unit
Raw value

In testing for 2024 to 2026.

Sport mode contactor state CITROEN_SPORT_MODE_CONTACTOR

  • Request22 D5 03
  • Service 22DID D503
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Start inhibit control, wired CITROEN_START_INHIBIT_CTRL

  • Request22 D7 67
  • Service 22DID D767
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Start or restart inhibition transmitted by engine management computer CITROEN_START_OR_RESTART

  • Request22 D7 1E
  • Service 22DID D71E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Start prohibition CITROEN_START_PROHIBITION

  • Request22 D5 1B
  • Service 22DID D51B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Starter activation counter CITROEN_STARTER_ACTIVATION

  • Request22 D7 1F
  • Service 22DID D71F
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2024 to 2026.

Starter control interface unit operating status CITROEN_STARTER_CTRL

  • Request22 D7 2A
  • Service 22DID D72A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Starter duty cycle CITROEN_STARTER_DUTY

  • Request22 D4 78
  • Service 22DID D478
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 s
Unit
s

In testing for 2024 to 2026.

Starter engagement status CITROEN_STARTER_ENGAGEMENT

  • Request22 D4 C3
  • Service 22DID D4C3
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

State lock/unlock control unit CITROEN_ST_LOCK_UNLOCK_CTRL

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Status of internal ignition motor CITROEN_STAT_INTERNAL_IGN

  • Request22 D4 12
  • Service 22DID D412
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Status of the energy accumulator CITROEN_STAT_ENERGY

  • Request22 D7 22
  • Service 22DID D722
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Stop allowed by ESP computer CITROEN_STOP_ALLOWED_ESP

  • Request22 D7 06
  • Service 22DID D706
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Stop and start function state CITROEN_STOP_START_FUNCTION

  • Request22 D7 25
  • Service 22DID D725
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Stop and start switch CITROEN_STOP_START_SWITCH

  • Request22 D7 26
  • Service 22DID D726
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Stop permitted by suspension computer CITROEN_STOP_PERMITTED

  • Request22 D7 07
  • Service 22DID D707
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Swirl actuator command CITROEN_SWIRL_CMD

  • Request22 18 9B
  • Service 22DID 189B
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-100 to 100 %
Unit
%

In testing for 2024 to 2026.

Temperature before catalyst CITROEN_T_BEFORE_CAT

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273.14 to 6280.36 °C
Unit
°C

In testing for 2024 to 2026.

Temperature before diesel particulate filter CITROEN_T_BEFORE_DPF

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273.14 to 6280.36 °C
Unit
°C

In testing for 2024 to 2026.

Temperature before turbine CITROEN_T_BEFORE_TURBINE

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273.14 to 6280.36 °C
Unit
°C

In testing for 2024 to 2026.

Temperature difference between the hottest and the coolest cells CITROEN_T_DIFF_HOTEST

  • Request22 D8 78
  • Service 22DID D878
  • Module6B4 → 694
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2024 to 2026.

Temperature of the energy accumulator CITROEN_T_ENERGY_ACCUMULATOR

  • Request22 D7 21
  • Service 22DID D721
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383 °C
Unit
°C

In testing for 2024 to 2026.

Temperature of the urea solution in the urea tank CITROEN_T_UREA_SOLUTION_UREA

  • Request22 D5 6D
  • Service 22DID D56D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2024 to 2026.

The composition of the mixture is calculated by the oxygen sensor CITROEN_COMPOSITION_MIXTURE

  • Request22 D5 70
  • Service 22DID D570
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2024 to 2026.

Throttle inlet air temperature filtered CITROEN_THROTTLE_INLET_AIR_T

  • Request22 14 B1
  • Service 22DID 14B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2024 to 2026.

Throttle inlet air temperature raw CITROEN_THROTTLE_INLET_AIR_T_RAW

  • Request22 14 B3
  • Service 22DID 14B3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2024 to 2026.

Throttle inlet pressure CITROEN_THROTTLE_INLET_P

  • Request22 12 47
  • Service 22DID 1247
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 160)
Range
0 to 409.5937 kPa
Unit
kPa

In testing for 2024 to 2026.

Time since active regen CITROEN_TIME_SINCE_ACTIVE

  • Request22 A0 03
  • Service 22DID A003
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2024 to 2026.

Time since regen started CITROEN_TIME_SINCE_REGEN

  • Request21 D6
  • Service 21PID D6
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 40)
Range
0 to 1638 s
Unit
s

In testing for 2024 to 2026.

Torque corresponding to driver requirement CITROEN_TQ_CORRESPONDING

  • Request22 D4 E3
  • Service 22DID D4E3
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2024 to 2026.

Torque supplied or taken by generator CITROEN_TQ_SUPPLIED_OR_TAKEN

  • Request22 D7 28
  • Service 22DID D728
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2024 to 2026.

Total mass of additive accumulated in the diesel particulate filter CITROEN_TOT_MASS_ADDITIVE

  • Request22 D5 26
  • Service 22DID D526
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 g
Unit
g

In testing for 2024 to 2026.

Total mass of additive accumulated in the diesel particulate filter CITROEN_TOT_MASS_ADDITIVE_ACCUMULATED_DPF

  • Request22 D5 27
  • Service 22DID D527
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047 g
Unit
g

In testing for 2024 to 2026.

Total mileage CITROEN_ODO_6A8

Pelican can show this parameter as the odometer.

  • Request22 D4 9C
  • Service 22DID D49C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2024 to 2026.

Total number of started regeneration events CITROEN_TOT_NUM_STARTED

  • Request22 18 E7
  • Service 22DID 18E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Number

In testing for 2024 to 2026.

Towing device configured CITROEN_CAN_VEH_BE_EQUIPPED

  • Request22 D5 57
  • Service 22DID D557
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Traction circuit coolant temperature CITROEN_TRACTION_CIRCUIT_ECT

  • Request22 D8 F9
  • Service 22DID D8F9
  • Module6A2 → 682
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2024 to 2026.

Traction or stability control regulating CITROEN_ASR_OR_ESP_SYSTEM

  • Request22 D5 12
  • Service 22DID D512
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Transmission fluid temperature CITROEN_ATF_T_V3

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2024 to 2026.

Turbine upstream temperature CITROEN_TURBINE_UP_T

  • Request22 01 68
  • Service 22DID 0168
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273.14 to 6280.36 °C
Unit
°C

In testing for 2024 to 2026.

Turbo boost pressure CITROEN_BOOST

  • Request22 19 5A
  • Service 22DID 195A
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 3276.8)
Range
-100 to 300 kPa
Unit
kPa

In testing for 2024 to 2026.

Turbo compressor inlet temperature CITROEN_TURBO_COMP_INLET_T

  • Request22 A0 EC
  • Service 22DID A0EC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 36 ÷ 5 + 32)
Range
0 to 1868 °F
Unit
°F

In testing for 2024 to 2026.

Urea mass fraction CITROEN_UREA_MASS_FRACTION

  • Request22 D5 8C
  • Service 22DID D58C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2024 to 2026.

Urea solution injected amount CITROEN_UREA_SOLUTION

  • Request22 D5 68
  • Service 22DID D568
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023
Unit
Raw value

In testing for 2024 to 2026.

Urea solution injection permission based on temperature value CITROEN_UREA_SOLUTION_INJ_ON_T

  • Request22 D5 15
  • Service 22DID D515
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Urea solution pressure CITROEN_UREA_SOLUTION_P

  • Request22 D5 3E
  • Service 22DID D53E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 bar
Unit
bar

In testing for 2024 to 2026.

Urea solution type in urea tank CITROEN_UREA_SOLUTION_TYPE

  • Request22 D5 8D
  • Service 22DID D58D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Urea tank heating current CITROEN_UREA_TANK_HEATING

  • Request22 D5 81
  • Service 22DID D581
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 %
Unit
%

In testing for 2024 to 2026.

Urea tank heating current, percentage CITROEN_UREA_TANK_HEATING_CURRENT

  • Request22 D5 1E
  • Service 22DID D51E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 163.8399875)
Range
0 to 399 %
Unit
%

In testing for 2024 to 2026.

Vacuum circuit vacuum CITROEN_VACUUM_CIRCUIT

  • Request22 D7 3B
  • Service 22DID D73B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2024 to 2026.

Value during generator load smooth increase CITROEN_DURING_GEN_LOAD

  • Request22 D7 53
  • Service 22DID D753
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Variable geometry turbo actuator, commanded position CITROEN_VGT_CMD_189F

  • Request22 18 9F
  • Service 22DID 189F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 39 ÷ 50 − 100)
Range
-100 to 98.9 %
Unit
%

In testing for 2024 to 2026.

Variable geometry turbo actuator, commanded position CITROEN_VGT_CMD_507B

  • Request22 50 7B
  • Service 22DID 507B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 39 ÷ 50 − 100)
Range
-100 to 98.9 %
Unit
%

In testing for 2024 to 2026.

Variable geometry turbo compressor inlet air temperature CITROEN_VGT_COMP_INLET_AIR_T

  • Request21 DA
  • Service 21PID DA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 9 ÷ 20 + 32)
Range
0 to 29522 °F
Unit
°F

In testing for 2024 to 2026.

Variable geometry turbo compressor outlet air temperature CITROEN_VGT_COMP_OULET_AIR_T

  • Request21 DA
  • Service 21PID DA
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 9 ÷ 20 + 32)
Range
0 to 29522 °F
Unit
°F

In testing for 2024 to 2026.

Variable oil pump position CITROEN_OIL_PUMP

  • Request22 19 4F
  • Service 22DID 194F
  • ModuleDA10 → 10
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Variable valve timing oil pressure CITROEN_VARIABLE_VLV_TIM_OIL_P

  • Request22 06 9E
  • Service 22DID 069E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 kPa
Unit
kPa

In testing for 2024 to 2026.

Variable valve timing oil temperature CITROEN_VARIABLE_VLV_TIM_OIL_T

  • Request22 06 9F
  • Service 22DID 069F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 °C
Unit
°C

In testing for 2024 to 2026.

Vehicle hour meter CITROEN_VEH_HOUR_METER

  • Request22 D8 01
  • Service 22DID D801
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 s
Unit
s

In testing for 2024 to 2026.

Vehicle mileage remaining before filling the tank with urea solution CITROEN_VEH_MILEAGE

  • Request22 D5 13
  • Service 22DID D513
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 km
Unit
km

In testing for 2024 to 2026.

Vehicle mileage since the last oil change under severe vehicle operating conditions CITROEN_VEH_MILEAGE_SINCE

  • Request22 D5 34
  • Service 22DID D534
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 km
Unit
km

In testing for 2024 to 2026.

VGT position actual CITROEN_VGT_ACT

  • Request22 18 A0
  • Service 22DID 18A0
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

VGT position commanded CITROEN_VGT_CMD

  • Request22 18 9F
  • Service 22DID 189F
  • ModuleDA10 → 10
  • Every2 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Volume of urea solution measured in urea tank CITROEN_VOLUME_UREA_SOLUTION

  • Request22 D5 58
  • Service 22DID D558
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 L
Unit
L

In testing for 2024 to 2026.

Wastegate position sensor CITROEN_WASTEGATE_POS_SENS

  • Request22 1F 59
  • Service 22DID 1F59
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 61 ÷ 12500)
Range
0 to 319.8107 V
Unit
V

In testing for 2024 to 2026.

Water in diesel CITROEN_WATER_DIESEL

  • Request22 D5 2C
  • Service 22DID D52C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Winter mode switch state CITROEN_WINTER_MODE_SWITCH

  • Request22 D5 02
  • Service 22DID D502
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.