Transmission parameters
The Dodge Dakota has 144 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Activation count, additional oil pump, ATN8 gearbox DODGE_NUM_ADDITIONAL_OIL
- Request
22 D7 50 - Service 22
DID D750 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, clutch electromagnetic valve C2 DODGE_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2
- Request
22 D7 43 - Service 22
DID D743 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, clutch electromagnetic valve C3 DODGE_NUM_ACTIVATIONS_CLU_C3
- Request
22 D7 44 - Service 22
DID D744 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, clutch protection C1 DODGE_NUM_ACTIVATIONS_CLU_C1
- Request
22 D7 31 - Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Activation count, clutch protection C2 DODGE_NUM_ACTIVATIONS_CLU_C2
- Request
22 D7 31 - Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Activation count, gear 7 DODGE_NUM_ACTIVATIONS_GEAR_7
- Request
22 D7 5B - Service 22
DID D75B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, shift solenoid SC2 DODGE_NUM_SHIFT_SOLENOID
- Request
22 D7 52 - Service 22
DID D752 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, shift solenoid SC3 DODGE_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3
- Request
22 D7 53 - Service 22
DID D753 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p DODGE_NUM_ACTIVATIONS_P
- Request
22 D7 58 - Service 22
DID D758 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, the electromagnetic valve of clutch C4 DODGE_NUM_ACTIVATIONS_C4
- Request
22 D7 59 - Service 22
DID D759 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, the electromagnetic valve of the clutch C1 DODGE_NUM_ACTIVATIONS_C1
- Request
22 D7 42 - Service 22
DID D742 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation count, torque converter lockup electromagnetic valve DODGE_NUM_ACTIVATIONS_TQ
- Request
22 D7 46 - Service 22
DID D746 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Activation of additional oil pump, ATN8 gearbox DODGE_ACTIVATION
- Request
22 D6 16 - Service 22
DID D616 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2012.
Additional oil pump control status, atn8 transmission DODGE_ADDITIONAL_OIL_PMP
- Request
22 D6 17 - Service 22
DID D617 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Automatic restart request from transmission computer DODGE_AUTOMATIC_RESTART_REQ
- Request
22 D7 0B - Service 22
DID D70B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Automatic stop allowed by gearbox computer DODGE_AUTOMATIC_STOP_ALLOWED
- Request
22 D7 04 - Service 22
DID D704 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Automatic transmission fluid temperature DODGE_AUTOMATIC_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 D5 50 - Service 22
DID D550 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2012.
Automatic transmission in emergency mode DODGE_AUTOMATIC_TRANS_EMERGENCY
- Request
22 D6 70 - Service 22
DID D670 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Automatic transmission in park position DODGE_AUTOMATIC_TRANS_PARK
- Request
22 D7 0B - Service 22
DID D70B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Automatic transmission input shaft mode, calculated DODGE_AUTOMATIC_TRANS_INPUT_SHFT_MODE
- Request
22 D6 51 - Service 22
DID D651 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Automatic transmission input shaft mode, measured DODGE_AUTOMATIC_TRANS_INPUT_SHFT
- Request
22 D6 50 - Service 22
DID D650 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Automatic transmission lubrication solenoid control current DODGE_AUTOMATIC_TRANS_LUBRICATION
- Request
22 D6 1A - Service 22
DID D61A - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Automatic transmission oil aging sensor DODGE_AUTOMATIC_TRANS_OIL
- Request
22 D4 05 - Service 22
DID D405 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Automatic transmission oil drain DODGE_DRAIN_TRANS
- Request
22 D5 09 - Service 22
DID D509 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Automatic transmission output shaft mode, calculated DODGE_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE
- Request
22 D6 53 - Service 22
DID D653 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 64 − 8128)- Range
- -8128 to 4186112 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Automatic transmission output shaft mode, measured DODGE_AUTOMATIC_TRANS_OUTPUT
- Request
22 D6 52 - Service 22
DID D652 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Automatic transmission overheat indicator request DODGE_AUTOMATIC_TRANS
- Request
22 D5 10 - Service 22
DID D510 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Automatic transmission temperature DODGE_ATF_T_DA18_V2
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 1D 09 - Service 22
DID 1D09 - Module
DA18 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2012.
Automatic transmission torque request DODGE_AUTOMATIC_TRANS_TQ
- Request
22 D5 08 - Service 22
DID D508 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 2012.
Calculated gear in gearbox DODGE_CALC_GEAR_GEARBOX
- Request
22 D4 09 - Service 22
DID D409 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Calculated nox content at the inlet of the nox catalytic converter DODGE_CALC_NOX_CONTENT
- Request
22 D5 3F - Service 22
DID D53F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 4194303
- Unit
- Raw value
In testing for 1988 to 2012.
Clutch pedal DODGE_CLU_PEDAL
- Request
22 D4 04 - Service 22
DID D404 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Clutch pedal position value DODGE_CLU_PEDAL_POS
- Request
22 D4 69 - Service 22
DID D469 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 1988 to 2012.
Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox DODGE_CTRL_CURRENT_P_P
- Request
22 D6 25 - Service 22
DID D625 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p DODGE_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P
- Request
22 D6 1E - Service 22
DID D61E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Control current of electromagnetic valve of change of pressure of torque converter lock-up DODGE_CTRL_CURRENT_P
- Request
22 D6 1C - Service 22
DID D61C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Control current of the electromagnetic valve for changing the gear shift SC2 DODGE_CTRL_CURRENT
- Request
22 D6 0A - Service 22
DID D60A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Control current of the electromagnetic valve of change of pressure of clutch C3 DODGE_CTRL_CURRENT_P_C3
- Request
22 D6 14 - Service 22
DID D614 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Control current of the electromagnetic valve of change of pressure of clutch C4 DODGE_CTRL_CURRENT_P_C4
- Request
22 D6 20 - Service 22
DID D620 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Control current of the solenoid valve for changing the pressure of the clutch C1 DODGE_CTRL_CURRENT_P_C1
- Request
22 D6 10 - Service 22
DID D610 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Control current of the solenoid valve for changing the pressure of the clutch C2 DODGE_CTRL_CURRENT_P_C2
- Request
22 D6 12 - Service 22
DID D612 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Current gear DODGE_CURRENT_GEAR
- Request
22 3C 22 - Service 22
DID 3C22 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Number
In testing for 1988 to 2012.
Current gear DODGE_GEAR
The automatic transmission gear.
- Request
22 55 03 - Service 22
DID 5503 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NEUTRAL | Neutral |
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
11 | REAR | Rear |
13 | PARK | Park |
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Current gear DODGE_GEAR_CURRENT
- Request
22 05 1A - Service 22
DID 051A - Module
DA18 → 18 - Every
250 ms - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
val- Range
- 0 to 15
- Unit
- Number
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Current gear, raw count DODGE_CURRENT_GEAR_RAW_CNT
- Request
22 55 03 - Service 22
DID 5503 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
DC-DC converter temperature DODGE_DC_DC_CONV_T
- Request
22 D8 CE - Service 22
DID D8CE - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 2012.
Desired gear DODGE_GEAR_DESIRED
- Request
22 05 1A - Service 22
DID 051A - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 3 of the reply, 4 bits.
- Formula
val- Range
- 0 to 15
- Unit
- Number
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Engaged gear DODGE_ENGAGED_GEAR
- Request
22 D4 3D - Service 22
DID D43D - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Engaged gear DODGE_ENGAGED_GEAR_6A9
- Request
22 D5 01 - Service 22
DID D501 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Evaluation of the thermal aging of the NOx catalytic converter DODGE_EVALUATION_THERMAL
- Request
22 D5 41 - Service 22
DID D541 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 655.35995)- Range
- 0 to 99.99 %
- Unit
- %
In testing for 1988 to 2012.
Exhaust gas temperature after upstream catalytic converter DODGE_EXH_GAS_T_AFTER_PRE
- Request
22 D5 55 - Service 22
DID D555 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 2012.
Exhaust gas temperature before upstream catalytic converter DODGE_EXH_GAS_T_BEFORE_PRE
- Request
22 D5 2E - Service 22
DID D52E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 2012.
Gear DODGE_GEAR_V2
- Request
22 1D 12 - Service 22
DID 1D12 - Module
DA18 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Gear engaged DODGE_GEAR_ECU
- Request
22 19 2D - Service 22
DID 192D - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 9
- Unit
- Number
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Gear in the process of engaging DODGE_GEAR_PROCESS
- Request
22 D4 3E - Service 22
DID D43E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Gear shift knob under steering wheel DODGE_GEAR_SHIFT_KNOB
- Request
22 D5 20 - Service 22
DID D520 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Gear shift lever position displayed on instrument panel DODGE_GEAR_SHIFT_LEVER_POS_ON
- Request
22 D5 00 - Service 22
DID D500 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Gear, raw count DODGE_GEAR_RAW_CNT
- Request
22 05 1A - Service 22
DID 051A - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Gearbox output speed DODGE_GEARBOX_RPM
- Request
22 21 02 - Service 22
DID 2102 - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Maximum clutch travel during gear shift DODGE_MAX_CLU_TRAVEL
- Request
22 D4 98 - Service 22
DID D498 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 %
- Unit
- %
In testing for 1988 to 2012.
Measured current of control of electromagnetic valve of automatic transmission lubrication DODGE_MEAS_CURRENT_CTRL
- Request
22 D6 1B - Service 22
DID D61B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up DODGE_MEAS_CURRENT_CTRL_P
- Request
22 D6 1D - Service 22
DID D61D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Measured current of the electromagnetic valve for changing the gear shift SC2 DODGE_MEAS_CURRENT
- Request
22 D6 0B - Service 22
DID D60B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox DODGE_MEAS_CURRENT_P_P
- Request
22 D6 26 - Service 22
DID D626 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Measured current of the electromagnetic valve of change of pressure of clutch C3 DODGE_MEAS_CURRENT_P_C3
- Request
22 D6 15 - Service 22
DID D615 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Measured current of the electromagnetic valve of change of pressure of clutch C4 DODGE_MEAS_CURRENT_P_C4
- Request
22 D6 21 - Service 22
DID D621 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Measured current of the solenoid valve for changing the pressure of the clutch C1 DODGE_MEAS_CURRENT_P_C1
- Request
22 D6 11 - Service 22
DID D611 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Measured current of the solenoid valve for changing the pressure of the clutch C2 DODGE_MEAS_CURRENT_P_C2
- Request
22 D6 13 - Service 22
DID D613 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p DODGE_MEAS_CURRENT_P
- Request
22 D6 1F - Service 22
DID D61F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Nitrogen oxide content after catalytic converter, ppm DODGE_NOX_CONTENT_AFTER
- Request
22 D5 3D - Service 22
DID D53D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Number
In testing for 1988 to 2012.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm DODGE_NOX_CONTENT_MEAS
- Request
22 D5 45 - Service 22
DID D545 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Number
In testing for 1988 to 2012.
Nitrogen oxide content measured at the inlet of the catalytic converter, ppm DODGE_NOX_CONTENT_MEAS_INLET_NOX
- Request
22 D5 76 - Service 22
DID D576 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Number
In testing for 1988 to 2012.
Nox catalytic converter urea content DODGE_NOX_CATALYTIC_CONV
- Request
22 D5 5D - Service 22
DID D55D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 999.9999525)- Range
- 0 to 65.53 g
- Unit
- g
In testing for 1988 to 2012.
Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox DODGE_NUM_ENGAGEMENTS_P_P
- Request
22 D7 5D - Service 22
DID D75D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements 1 DODGE_NUM_GEAR_ENGAGEMENTS_1
- Request
22 D7 47 - Service 22
DID D747 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements 2 DODGE_NUM_GEAR_ENGAGEMENTS_2
- Request
22 D7 48 - Service 22
DID D748 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements 3 DODGE_NUM_GEAR_ENGAGEMENTS_3
- Request
22 D7 49 - Service 22
DID D749 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements 4 DODGE_NUM_GEAR_ENGAGEMENTS_4
- Request
22 D7 4A - Service 22
DID D74A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements 5 DODGE_NUM_GEAR_ENGAGEMENTS_5
- Request
22 D7 4B - Service 22
DID D74B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements 6 DODGE_NUM_GEAR_ENGAGEMENTS_6
- Request
22 D7 4C - Service 22
DID D74C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements 8 DODGE_NUM_GEAR_ENGAGEMENTS_8
- Request
22 D7 5C - Service 22
DID D75C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements n DODGE_NUM_GEAR_ENGAGEMENTS_N
- Request
22 D7 4E - Service 22
DID D74E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of gear engagements right DODGE_NUM_GEAR_ENGAGEMENTS
- Request
22 D7 4D - Service 22
DID D74D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of shift solenoid operated automatic transmission lubrication control valve DODGE_NUM_SHIFT_SOLENOID_OPERATED
- Request
22 D7 56 - Service 22
DID D756 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of shift solenoid operated SC4 DODGE_NUM_SHIFT_SOLENOID_OPERATED_SC4
- Request
22 D7 54 - Service 22
DID D754 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of shift solenoid operated SC5 DODGE_NUM_SHIFT_SOLENOID_OPERATED_SC5
- Request
22 D7 55 - Service 22
DID D755 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Number of shift solenoid operated torque converter lock-up pressure regulating valve DODGE_NUM_SHIFT_SOLENOID_P
- Request
22 D7 57 - Service 22
DID D757 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2012.
Operating mode used by the automatic transmission DODGE_OP_MODE_USED
- Request
22 D6 73 - Service 22
DID D673 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Position of the gearshift lever DODGE_POS_GEARSHIFT_LEVER
- Request
22 D7 00 - Service 22
DID D700 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Proportional clutch pedal sensor DODGE_PROPORTIONAL_CLU
- Request
22 D5 6E - Service 22
DID D56E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Reverse gear contactor status DODGE_REVERSE_GEAR
- Request
22 D4 3C - Service 22
DID D43C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
SC5 shift solenoid control current DODGE_SC5_SHIFT_SOLENOID
- Request
22 D6 18 - Service 22
DID D618 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
SC5 shift solenoid measured current DODGE_SC5_SHIFT_SOLENOID_MEAS
- Request
22 D6 19 - Service 22
DID D619 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Shift solenoid control current SC3 DODGE_SHIFT_SOLENOID_CTRL
- Request
22 D6 0C - Service 22
DID D60C - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Shift solenoid control current SC4 DODGE_SHIFT_SOLENOID_CTRL_CURRENT_SC4
- Request
22 D6 0E - Service 22
DID D60E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Shift solenoid measured current SC3 DODGE_SHIFT_SOLENOID_MEAS
- Request
22 D6 0D - Service 22
DID D60D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Shift solenoid measured current SC4 DODGE_SHIFT_SOLENOID_MEAS_CURRENT_SC4
- Request
22 D6 0F - Service 22
DID D60F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Shift-lock control DODGE_SHIFT_LOCK_CTRL
- Request
22 D7 01 - Service 22
DID D701 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Start permission from gearbox computer DODGE_START_PERMISSION
- Request
22 D4 1A - Service 22
DID D41A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Target gear DODGE_GEAR_TARGET
The target gear.
- Request
22 55 04 - Service 22
DID 5504 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NEUTRAL | Neutral |
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
11 | REAR | Rear |
13 | PARK | Park |
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Temperature of the nox catalytic converter DODGE_T_NOX_CATALYTIC_CONV
- Request
22 D5 43 - Service 22
DID D543 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °C
- Unit
- °C
In testing for 1988 to 2012.
Torque converter lock status DODGE_TQ_CONV_LOCK
- Request
22 B0 9B - Service 22
DID B09B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Torque converter lock-up pressure variation solenoid valve control current DODGE_TQ_CONV_LOCK_UP_P
- Request
22 D6 04 - Service 22
DID D604 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Torque converter lock-up pressure variation solenoid valve control current DODGE_TQ_CONV_LOCK_UP_P_VARIATION
- Request
22 D6 05 - Service 22
DID D605 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2012.
Torque converter slip DODGE_TQ_CONV_SLIP
- Request
22 B0 28 - Service 22
DID B028 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Torque converter slip mode, theoretical value DODGE_TQ_CONV_SLIP_MODE
- Request
22 D6 55 - Service 22
DID D655 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 64 − 8128)- Range
- -8128 to 8192 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Torque converter slip, variant 1 DODGE_TQ_CONV_SLIP_VAR_1
- Request
22 B0 28 - Service 22
DID B028 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 9 ÷ 640)- Range
- -460 to 460 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Torque converter slip, variant 2 DODGE_TQ_CONV_SLIP_VAR_2
- Request
22 A0 01 - Service 22
DID A001 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Torque converter status DODGE_TQ_CONV_STAT
- Request
22 D5 04 - Service 22
DID D504 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Transmission fluid temperature DODGE_ATF_T_08DF
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 08 DF - Service 22
DID 08DF - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2012.
Transmission fluid temperature DODGE_ATF_T_2118
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 18 - Service 21
PID 18 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 40)- Range
- -40 to 983 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission fluid temperature DODGE_ATF_T_7E1
- Request
21 5C - Service 21
PID 5C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2012.
Transmission fluid temperature DODGE_ATF_T_7E1_2
- Request
22 50 43 - Service 22
DID 5043 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2012.
Transmission fluid temperature DODGE_ATF_T_7E1_V2
- Request
21 72 - Service 21
PID 72 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission fluid temperature DODGE_ATF_T_7E1_V3
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 50 43 - Service 22
DID 5043 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2012.
Transmission fluid temperature DODGE_ATF_T_DA18
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 04 FE - Service 22
DID 04FE - Module
DA18 → 18 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2012.
Transmission fluid temperature DODGE_ATF_T_V2
- Request
22 04 FE - Service 22
DID 04FE - Module
DA18 → 18 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2012.
Transmission fluid temperature, variant 1 DODGE_ATF_T_VAR_1
- Request
22 B0 10 - Service 22
DID B010 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission fluid temperature, variant 1 DODGE_ATF_T_VAR_1_7E1
- Request
21 72 - Service 21
PID 72 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission fluid temperature, variant 1 DODGE_ATF_T_VAR_1_V2
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 72 - Service 21
PID 72 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission fluid temperature, variant 1 DODGE_ATF_T_VAR_1_V3
- Request
21 18 - Service 21
PID 18 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 40)- Range
- -40 to 983 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission fluid temperature, variant 2 DODGE_ATF_T_V_2
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 18 - Service 21
PID 18 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission fluid temperature, variant 2 DODGE_ATF_T_VAR_2
- Request
22 A0 02 - Service 22
DID A002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission fluid temperature, variant 3 DODGE_ATF_T_2130
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 30 - Service 21
PID 30 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2012.
Transmission fluid temperature, variant 3 DODGE_ATF_T_VAR_3
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 B0 10 - Service 22
DID B010 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission gear, actual DODGE_GEAR_7E0
- Request
22 A0 A0 - Service 22
DID A0A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Transmission gear, commanded DODGE_GEAR_CMD
- Request
22 A0 9F - Service 22
DID A09F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2012.
Transmission input speed DODGE_AT_INPUT_RPM
- Request
22 1D 08 - Service 22
DID 1D08 - Module
DA18 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Transmission oil temperature DODGE_TOT
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 18 - Service 21
PID 18 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4)- Range
- -512 to 512 °F
- Unit
- °F
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Transmission output speed DODGE_AT_OUTPUT_RPM
- Request
22 1D 07 - Service 22
DID 1D07 - Module
DA18 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1988 to 2012.
Transmission sump temperature DODGE_TRANS_SUMP_T
- Request
22 A0 A3 - Service 22
DID A0A3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 640)- Range
- 0 to 921 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission sump temperature DODGE_TRANS_SUMP_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 3A - Service 21
PID 3A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission sump temperature, variant 1 DODGE_TRANS_SUMP_T_VAR_1
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission sump temperature, variant 2 DODGE_TRANS_SUMP_T_VAR_2
- Request
21 CA - Service 21
PID CA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission temperature DODGE_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 04 FE - Service 22
DID 04FE - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1.8 − 40)- Range
- -30 to 300 °F
- Unit
- °F
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Transmission temperature DODGE_ATF_T_2
- Request
22 04 FE - Service 22
DID 04FE - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1.8 − 40)- Range
- -30 to 300 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission temperature, variant 2 DODGE_TRANS_T_VAR_2
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 0A - Service 21
PID 0A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission temperature, variant 2 DODGE_TRANS_T_VAR_2_7E1
- Request
21 0A - Service 21
PID 0A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission temperature, variant 2 DODGE_TRANS_T_VAR_2_V2
- Request
22 04 FE - Service 22
DID 04FE - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 40)- Range
- -40 to 419 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission torque converter temperature DODGE_TRANS_TQ_CONV_T
- Request
22 A0 A4 - Service 22
DID A0A4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 320)- Range
- 0 to 1843 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission torque converter temperature, variant 1 DODGE_TRANS_TQ_CONV_T_VAR_1
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 9 ÷ 320 + 32)- Range
- 0 to 1875 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission torque converter temperature, variant 2 DODGE_TRANS_TQ_CONV_T_VAR_2
- Request
21 CA - Service 21
PID CA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 9 ÷ 320 + 32)- Range
- 0 to 1875 °F
- Unit
- °F
In testing for 1988 to 2012.
Transmission-reported torque DODGE_TCM_TORQUE
- Request
22 10 18 - Service 22
DID 1018 - Module
DA18 → 18 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 500)- Range
- -500 to 1000 N·m
- Unit
- N·m
In testing for 1988 to 2005, 2007 to 2012. Not supported for 2006.
Upstream catalytic converter aging DODGE_PRE_CATALYTIC_CONV
- Request
22 D5 59 - Service 22
DID D559 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 1988 to 2012.