Engine parameters
The Dodge Grand Caravan has 375 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
5V power supply state number 1 DODGE_5V_POWER_SUP_ST_1
- Request
22 D4 23 - Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
5V power supply state number 2 DODGE_5V_POWER_SUP_ST_2
- Request
22 D4 24 - Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
5V power supply state number 3 DODGE_5V_POWER_SUP_ST_3
- Request
22 D4 25 - Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
5V power supply state number 4 DODGE_5V_POWER_SUP_ST_4
- Request
22 D4 26 - Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
12V network allowed stop DODGE_12V_NETWORK_ALLOWED
- Request
22 D7 4C - Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2013, 2017.
Activation count, brake electromagnetic valve B1 DODGE_NUM_ACTIVATIONS_B1
- Request
22 D7 45 - Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2020.
Activation count, line pressure control solenoid DODGE_NUM_LINE_P_CTRL
- Request
22 D7 51 - Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2020.
Activation count, the electromagnetic valve of brake B2 DODGE_NUM_ACTIVATIONS_B2
- Request
22 D7 5A - Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2020.
Actual oil pressure DODGE_ACT_OIL_P
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 bar
- Unit
- bar
In testing for 1988 to 2020.
Additional heater control 1 DODGE_ADDITIONAL_HEATER_1
- Request
22 D4 16 - Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
AFT DPF oulet pressure sensor DODGE_AFT_DPF_OULET_P_SENS
- Request
22 A0 0A - Service 22
DID A00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 2000)- Range
- 0 to 294 psi
- Unit
- psi
In testing for 1988 to 2020.
Air conditioning DODGE_AC
- Request
22 D4 AF - Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Air conditioning compressor current DODGE_AC_COMP_CURRENT
- Request
22 D4 1C - Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375
- Unit
- Number
In testing for 1988 to 2020.
Air conditioning high side pressure DODGE_AC_HIGH_SIDE_P
- Request
22 03 29 - Service 22
DID 0329 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 14)- Range
- 0 to 3570 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Air conditioning high side pressure DODGE_AC_HIGH_SIDE_P_7E0
- Request
21 A7 - Service 21
PID A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 55)- Range
- 0 to 1191 psi
- Unit
- psi
In testing for 1988 to 2020.
Air conditioning high side pressure DODGE_AC_HIGH_SIDE_P_V2
- Request
22 D8 FF - Service 22
DID D8FF - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 bar
- Unit
- bar
In testing for 1988 to 2020.
Air conditioning pressure DODGE_AC_P
- Request
22 D4 21 - Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 1988 to 2020.
Air conditioning refrigerant pressure DODGE_AC_REFRIGERANT_P
- Request
22 40 01 - Service 22
DID 4001 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 1988 to 2020.
Air doser first electronic loading DODGE_AIR_DOSER_FIRST
- Request
22 D5 3B - Service 22
DID D53B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Air flow DODGE_AIR_FLOW
- Request
22 D4 89 - Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 1988 to 2020.
Air flow target DODGE_AIR_FLOW_TGT
- Request
22 D4 8E - Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 1988 to 2020.
Air heater core temperature DODGE_AIRHEATER_CORE_T
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Air heater current DODGE_AIRHEATER_CURRENT
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 A
- Unit
- A
In testing for 1988 to 2020.
Air heater power consumption DODGE_AIRHEATER_POWER_CONS
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Air metering valve duty cycle DODGE_AIR_METERING_VLV
- Request
22 D4 61 - Service 22
DID D461 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 2020.
Air metering valve position DODGE_AIR_METERING_VLV_POS
- Request
22 D5 4F - Service 22
DID D54F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 2020.
Air metering valve, target position DODGE_AIR_METERING_VLV_TGT
- Request
22 D4 60 - Service 22
DID D460 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 2020.
Air temperature by air flow meter DODGE_AIR_T_AIR_FLOW_METER
- Request
22 D5 4E - Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 2020.
Alternator load value DODGE_ALTERNATOR_LOAD
- Request
22 D4 A5 - Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2020.
Ambient air temperature DODGE_AAT_6A9
- Request
22 D5 52 - Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 1988 to 2020.
Ambient air temperature DODGE_AAT_7E0
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 1988 to 2020.
Ambient temperature DODGE_AAT
- Request
22 01 27 - Service 22
DID 0127 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
In testing for 1988 to 2020.
Ambient temperature DODGE_AAT_V2
- Request
22 D4 34 - Service 22
DID D434 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1988 to 2020.
ANTI START PROGRAMMING STATUS DODGE_ANTI_START
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Assessment of thermal aging of the particulate filter DODGE_ASSESSMENT_THERMAL
- Request
22 D5 32 - Service 22
DID D532 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 128)- Range
- 0 to 12799 %
- Unit
- %
In testing for 1988 to 2020.
Atmospheric pressure DODGE_ATMOSPHERIC_P
- Request
22 D4 65 - Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1988 to 2020.
Automatic restart request from body control module DODGE_AUTOMATIC_RESTART_REQ_BSI
- Request
22 D7 0A - Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Automatic restart request from engine management computer DODGE_AUTOMATIC_RESTART
- Request
22 D7 09 - Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Automatic stop allowed by body control module DODGE_AUTOMATIC_STOP
- Request
22 D7 03 - Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Automatic stop allowed by power steering computer DODGE_AUTOMATIC_STOP_ALLOWED_POWER_STEER
- Request
22 D7 05 - Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Automatic transmission fluid temperature DODGE_ATF_T_3RDGEN
- Request
21 18 - Service 21
PID 18 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 40)- Range
- -40 to 983.9843 °F
- Unit
- °F
In testing for 1988 to 2011, 2014 to 2015, 2018, 2020. Not supported for 2012 to 2013, 2016 to 2017, 2019.
Automatic transmission fluid temperature DODGE_ATF_T_3RDGEN_V2
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 5C - Service 21
PID 5C - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2011, 2014 to 2015, 2018, 2020. Not supported for 2012 to 2013, 2016 to 2017, 2019.
Auxiliary heater 2 control DODGE_AUXILIARY_HEATER_2
- Request
22 D4 17 - Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Average mileage for the last 10 regenerations DODGE_AVG_MILEAGE_LAST_10
- Request
22 D5 25 - Service 22
DID D525 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 16)- Range
- 0 to 4095 km
- Unit
- km
In testing for 1988 to 2020.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Barometric pressure DODGE_BAROMETRIC_P
- Request
22 01 09 - Service 22
DID 0109 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Boost air temperature DODGE_BOOST_AIR_T
- Request
22 D4 11 - Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 2020.
Boost pressure DODGE_BOOST_P
- Request
22 A0 54 - Service 22
DID A054 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 435)- Range
- 0 to 150 psi
- Unit
- psi
In testing for 1988 to 2020.
Boost pressure estimate DODGE_BOOST_P_ESTIMATE
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 441)- Range
- 0 to 148 psi
- Unit
- psi
In testing for 1988 to 2020.
Button state DODGE_BUTTON_ST
- Request
22 D5 17 - Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2016 to 2017. Supported for 2012, 2018 to 2020.
Cam crank difference DODGE_CAM_CRANK_DIFF
- Request
22 05 9E - Service 22
DID 059E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 1988 to 2020.
Camshaft/crankshaft position synchronization DODGE_CAM_CRANK_POS
- Request
22 D4 18 - Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Catalyst modeled temperature DODGE_CAT_MODEL_T
- Request
22 01 2B - Service 22
DID 012B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 1000 °C
- Unit
- °C
In testing for 1988 to 2020.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed
- Request
01 3D - Service 01
PID 3D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
CHANGE REPORT IN PROGRESS DODGE_CHANGE_REPORT
- Request
22 D5 16 - Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Closed loop soot load assessment of the diesel particulate filter DODGE_CLOSED_LOOP_SOOT
- Request
22 D5 4B - Service 22
DID D54B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.99 g/L
- Unit
- g/L
In testing for 1988 to 2020.
Combustion engine state DODGE_ICE_ST
- Request
22 D7 09 - Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2013, 2016 to 2017.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Commanded oil pressure DODGE_CMD_OIL_P
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 1988 to 2020.
Commanded power DODGE_CMD_POWER
- Request
22 19 97 - Service 22
DID 1997 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2020.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017.
Computer lock DODGE_COMPUTER_LOCK
- Request
22 DA DD - Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Computer remote wake-up state DODGE_COMPUTER_WAKE_UP_ST
- Request
22 D5 15 - Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Computer restarts since memory erase DODGE_CNT_NUM_RE
- Request
22 D4 D8 - Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2020.
Computer temperature DODGE_COMPUTER_T
- Request
22 D4 35 - Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 2020.
Control current of electromagnetic valve for changing the pressure in the brake system B2 DODGE_CTRL_CURRENT_P_B2
- Request
22 D6 22 - Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2020.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 DODGE_CTRL_CURRENT_P_B1
- Request
22 D6 08 - Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2020.
Controlled air supply module DODGE_CONTROLLED_AIR_SUP
- Request
22 D4 A0 - Service 22
DID D4A0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Coolant temperature DODGE_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Request
22 D4 15 - Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 2020.
Coolant temperature DODGE_ECT_ECU
- Request
22 10 03 - Service 22
DID 1003 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Coolant temperature DODGE_ECT_V2
Pelican can show this parameter as the engine coolant temperature.
- Request
22 D8 FB - Service 22
DID D8FB - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 1988 to 2020.
Coolant temperature target DODGE_ECT_TGT
- Request
22 D4 0D - Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 2020.
Coolant temperature, corrected DODGE_ECT_CORRECTED
- Request
22 D4 0A - Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 2020.
Crankcase differential pressure DODGE_CRANKCASE_DIFF_P
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 1988 to 2020.
Crankcase pressure DODGE_CRANKCASE_P
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1761)- Range
- 0 to 37.21 psi
- Unit
- psi
In testing for 1988 to 2020.
Cruise control, RW status DODGE_CRUISE_CTRL_RW_STAT
- Request
22 D4 B0 - Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Cylinder 1 injector flow correction DODGE_CYL_1_INJ_FLOW_CORR
- Request
22 D5 46 - Service 22
DID D546 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 2020.
Cylinder 2 injector flow correction DODGE_CYL_2_INJ_FLOW_CORR
- Request
22 D5 47 - Service 22
DID D547 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 2020.
Cylinder 3 injector flow correction DODGE_CYL_3_INJ_FLOW_CORR
- Request
22 D5 48 - Service 22
DID D548 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 2020.
Cylinder 4 injector flow correction DODGE_CYL_4_INJ_FLOW_CORR
- Request
22 D5 49 - Service 22
DID D549 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 2020.
Date DODGE_DATE
- Request
22 D4 CA - Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
In testing for 1988 to 2020.
DEF dosing rate, gph DODGE_DEF_DOSING_RATE_GPH
- Request
22 A1 29 - Service 22
DID A129 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 1988 to 2020.
DEF level DODGE_DEF_LEVEL
- Request
22 A0 06 - Service 22
DID A006 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2020.
DEF quality DODGE_DEF_QUALITY
- Request
22 A1 2B - Service 22
DID A12B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2020.
DEF temperature DODGE_DEF_T
- Request
22 A0 04 - Service 22
DID A004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 %
- Unit
- %
In testing for 1988 to 2020.
Diesel fuel temperature DODGE_FUEL_TEMP
- Request
22 19 00 - Service 22
DID 1900 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Diesel particulate filter delta pressure DODGE_DPF_DELTA_P
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 73 ÷ 500)- Range
- 0 to 37.2299 psi
- Unit
- psi
In testing for 1988 to 2020.
Diesel particulate filter differential pressure DODGE_DPF_DIFF_P
- Request
22 18 E2 - Service 22
DID 18E2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 32768)- Range
- -32768 to -26214.5
- Unit
- Raw value
In testing for 1988 to 2020.
Diesel particulate filter differential pressure sensor signal deviation from reference value DODGE_DPF_DIFF_P_SENS_SIG
- Request
22 D5 18 - Service 22
DID D518 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 2020.
Diesel particulate filter flow resistance DODGE_DPF_FLOW_RES_V2
- Request
22 01 E2 - Service 22
DID 01E2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10000)- Range
- -3.2768 to 3.2767
- Unit
- Number
In testing for 1988 to 2020.
Diesel particulate filter inlet gas temperature DODGE_INLET_DPF_GAS_T
- Request
22 18 DE - Service 22
DID 18DE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.019608 − 40)- Range
- -40 to 1245.0102 °C
- Unit
- °C
In testing for 1988 to 2020.
Diesel particulate filter regen active DODGE_DPF_REGEN_ACTIVE_7E0
- Request
21 D8 - Service 21
PID D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 79 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2020.
Diesel particulate filter regeneration DODGE_DPF_REGEN
- Request
21 48 - Service 21
PID 48 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 383 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2020.
Diesel particulate filter regeneration status DODGE_DPF_REGEN_STAT
- Request
22 D5 21 - Service 22
DID D521 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Diesel particulate filter soot load DODGE_DPF_SOOT_LOAD
- Request
22 01 E2 - Service 22
DID 01E2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 g/L
- Unit
- g/L
In testing for 1988 to 2020.
Diesel particulate filter soot mass DODGE_DPF_SOOT_MASS
- Request
22 18 E4 - Service 22
DID 18E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 763 ÷ 50000)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2020.
Differential pressure at particulate filter DODGE_DIFF_P_PF
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 2020.
Drive motor coolant inlet temperature DODGE_DRIVE_MOTOR_CLT_T
- Request
22 D8 D6 - Service 22
DID D8D6 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor coolant inlet temperature DODGE_EMOTOR_CLT_INLET_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor coolant outlet temperature DODGE_EMOTOR_CLT_OUTLET_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor inverter temperature 0 DODGE_EMOTOR_INVERTER_T_0
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor inverter temperature 1 DODGE_EMOTOR_INVERTER_T_1
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor inverter temperature 2 DODGE_EMOTOR_INVERTER_T_2
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor inverter temperature model DODGE_EMOTOR_INVERTER_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor PCB temperature DODGE_EMOTOR_PCB_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor power DODGE_DRIVE_MOTOR_POWER
- Request
22 D8 D9 - Service 22
DID D8D9 - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100)- Range
- -3276800 to 3276700 W
- Unit
- W
In testing for 1988 to 2020.
Drive motor rotor temperature DODGE_EMOTOR_ROTOR_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor stator temperature DODGE_DRIVE_MOTOR_STATOR_T
- Request
22 D8 CD - Service 22
DID D8CD - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor stator temperature DODGE_EMOTOR_STATOR_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Drive motor torque achieved DODGE_EMOTOR_TQ_ACHIEVED
- Request
22 30 64 - Service 22
DID 3064 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Drive motor torque limit DODGE_EMOTOR_TQ_LIM
- Request
22 30 63 - Service 22
DID 3063 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Drive motor torque, actual DODGE_DRIVE_MOTOR_TQ_ACT
- Request
22 D8 D0 - Service 22
DID D8D0 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Drive motor torque, commanded DODGE_EMOTOR_TQ_CMD
- Request
22 30 64 - Service 22
DID 3064 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Drive motor torque, desired DODGE_DRIVE_MOTOR_TQ_DES
- Request
22 D8 80 - Service 22
DID D880 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Driver presence DODGE_DRIVER_PRESENCE
- Request
22 D7 23 - Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Driver, requested torque value DODGE_DRIVER_REQ_TQ
- Request
22 D5 07 - Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Economy mode off state DODGE_ECO_MODE_OFF_ST
- Request
22 D7 24 - Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Electric A/C compressor HV current DODGE_EAC_HV_CURRENT
- Request
22 40 11 - Service 22
DID 4011 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 A
- Unit
- A
In testing for 1988 to 2020.
Electric cooling fan control DODGE_GMV_ELEC_COOLING_FAN
- Request
22 D4 2F - Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Electric machine torque DODGE_ELEC_MACHINE_TQ
- Request
22 DC B6 - Service 22
DID DCB6 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 1638.3)- Range
- -1638 to 4915 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Electric machine torque reduction DODGE_ELEC_MACHINE_TQ_REDUCTION
- Request
22 DC 69 - Service 22
DID DC69 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Energy accumulator state transfer DODGE_ENERGY_ACCUMULATOR_ST
- Request
22 D7 55 - Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Energy accumulator temperature limiter state DODGE_ENERGY_ACCUMULATOR_T
- Request
22 D7 58 - Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Engine control module status DODGE_ENG_CTRL_MODULE_STAT
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Engine coolant temperature DODGE_ECT
- Request
22 01 1D - Service 22
DID 011D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 2020.
Engine coolant temperature DODGE_ECT_6A9
- Request
22 D5 55 - Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2020.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2013, 2016 to 2017. Supported for 2012, 2018 to 2020.
Engine oil degradation DODGE_OIL_DEGRAD
- Request
22 38 13 - Service 22
DID 3813 - Module
DA10 → 10 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Engine oil dilution protection status DODGE_ENG_OIL_DILUTION
- Request
22 D5 24 - Service 22
DID D524 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Engine oil pressure DODGE_EOP
- Request
22 02 2A - Service 22
DID 022A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 29 ÷ 50)- Range
- 0 to 147.8999 psi
- Unit
- psi
In testing for 1988 to 2020.
Engine oil temperature DODGE_EOT
- Request
21 2D - Service 21
PID 2D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 2020.
Engine oil temperature DODGE_EOT_212D
Pelican can show this parameter as the engine oil temperature.
- Request
21 2D - Service 21
PID 2D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
In testing for 1988 to 2020.
Engine oil temperature DODGE_EOT_21D2
Pelican can show this parameter as the engine oil temperature.
- Request
21 D2 - Service 21
PID D2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 2020.
Engine oil temperature DODGE_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549.94 to 3003.56 °C
- Unit
- °C
In testing for 1988 to 2020.
Engine operating mode DODGE_ENG_OP_MODE
- Request
22 D5 53 - Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8)- Range
- 0 to 8191 rpm
- Unit
- rpm
In testing for 1988 to 2020.
Engine operational status DODGE_ENGINE_STATUS
- Request
22 10 02 - Service 22
DID 1002 - Module
DA10 → 10 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Engine restart counter DODGE_ENG_RESTART_CNT
- Request
22 D4 06 - Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2020.
Engine restart counter by stop and start function DODGE_ENG_RESTART_CNT_STOP
- Request
22 D7 1B - Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2020.
Engine restart request sent by ESP computer DODGE_ENG_RESTART_REQ_SENT
- Request
22 D7 0D - Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Engine RPM DODGE_RPM_ECU
- Request
22 10 00 - Service 22
DID 1000 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Engine stalls DODGE_ENG_STALLS
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Engine start prohibition control, start lock DODGE_ENG_START
- Request
22 D7 03 - Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Engine stop time DODGE_ENG_STOP_TIME
- Request
22 D4 77 - Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
In testing for 1988 to 2020.
Engine temperature DODGE_ENG_TEMEPRATURE
- Request
22 01 98 - Service 22
DID 0198 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1988 to 2020.
Engine torque DODGE_ENG_TQ
- Request
21 C3 - Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Estimated soot removal time DODGE_ESITMATED_SOOT
- Request
21 57 - Service 21
PID 57 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2020.
Estimated torque of internal friction of the engine DODGE_ESTIMATED_TQ
- Request
22 D4 E2 - Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Evaluation of carbon content in engine oil DODGE_EVALUATION_CARBON
- Request
22 D5 23 - Service 22
DID D523 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96 %
- Unit
- %
In testing for 1988 to 2020.
Evaluation of the degree of dilution of motor oil DODGE_EVALUATION_DEGREE
- Request
22 D5 1F - Service 22
DID D51F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 %
- Unit
- %
In testing for 1988 to 2020.
Evaluation of the exhaust gas flow using the nox sensor DODGE_EVALUATION_EXH_GAS
- Request
22 D5 42 - Service 22
DID D542 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val × 100)- Range
- -214748364800 to 214748364700 L
- Unit
- L
In testing for 1988 to 2020.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Request
01 32 - Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4000)- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Exhaust camshaft 1 to crankshaft offset DODGE_EXH_CAM_1_OFFSET
- Request
22 06 1B - Service 22
DID 061B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1988 to 2020.
Exhaust gas flow through the particulate filter DODGE_EXH_GAS_FLOW_THROUGH
- Request
22 D5 33 - Service 22
DID D533 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 219.726593)- Range
- 0 to 14399782 L
- Unit
- L
In testing for 1988 to 2020.
Exhaust gas pressure at the outlet of the particulate filter DODGE_EXH_GAS_P_OUTLET_PF
- Request
22 D5 44 - Service 22
DID D544 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 999.9999525)- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 1988 to 2020.
Exhaust gas recirculation airflow control valve position DODGE_EGR_AIRFLOW_CTRL_VLV
- Request
21 D7 - Service 21
PID D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 39 ÷ 5000)- Range
- 0 to 511 %
- Unit
- %
In testing for 1988 to 2020.
Exhaust gas recirculation cooler downstream temperature DODGE_EGR_COOLER_T
- Request
22 39 17 - Service 22
DID 3917 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 900 °C
- Unit
- °C
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Exhaust gas recirculation flow DODGE_EGR_FLOW
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 kg/h
- Unit
- kg/h
In testing for 1988 to 2020.
Exhaust gas recirculation high limit electronic loading DODGE_EGR_HIGH_LIM
- Request
22 D5 53 - Service 22
DID D553 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Exhaust gas recirculation low limit electronic loading DODGE_EGR_LOW_LIM
- Request
22 D5 52 - Service 22
DID D552 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Exhaust gas recirculation orifice temperature DODGE_EGR_ORIFICE_T
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val × 9 ÷ 20 + 32)- Range
- 0 to 29522 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas recirculation temperature DODGE_EGR_T
- Request
22 A0 DC - Service 22
DID A0DC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 9 ÷ 640)- Range
- 0 to 921 %
- Unit
- %
In testing for 1988 to 2020.
Exhaust gas recirculation valve duty cycle DODGE_EGR_VLV_CTRL_SIG_RCO
- Request
22 D5 11 - Service 22
DID D511 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 2020.
Exhaust gas recirculation valve first electronic loading DODGE_EGR_VLV_FIRST
- Request
22 D5 3A - Service 22
DID D53A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Exhaust gas recirculation valve position DODGE_EGR_VLV_POS
- Request
22 A0 DA - Service 22
DID A0DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 %
- Unit
- %
In testing for 1988 to 2020.
Exhaust gas recirculation valve position DODGE_EGR_VLV_POS_V2
- Request
22 D5 09 - Service 22
DID D509 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 2020.
Exhaust gas recirculation valve set position DODGE_EGR_VLV_SET_POS
- Request
22 D5 10 - Service 22
DID D510 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 2020.
Exhaust gas recirculation valve, commanded position DODGE_EGR_VLV_CMD_POSTIION
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 + 32)- Range
- 0 to 543 %
- Unit
- %
In testing for 1988 to 2020.
Exhaust gas temperature 1 DODGE_EXH_GAS_T_1
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 144 ÷ 5 + 32)- Range
- 0 to 7376 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 1 DODGE_EXH_GAS_T_1_7E0
- Request
21 48 - Service 21
PID 48 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 1 – DOC inlet DODGE_EXH_GAS_T_1_DOC
- Request
22 A0 BD - Service 22
DID A0BD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 2 DODGE_EXH_GAS_T_2
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 9 ÷ 80 + 32)- Range
- 0 to 7404 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 2 DODGE_EXH_GAS_T_2_7E0
- Request
21 48 - Service 21
PID 48 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 2 – DOC outlet DODGE_EXH_GAS_T_2_DOC
- Request
22 A0 C2 - Service 22
DID A0C2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 3 DODGE_EXH_GAS_T_3
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 9 ÷ 80 + 32)- Range
- 0 to 7404 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 3 – DPF outlet DODGE_EXH_GAS_T_3_DPF
- Request
22 A0 C4 - Service 22
DID A0C4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 4 DODGE_EXH_GAS_T_4
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 9 ÷ 80 + 32)- Range
- 0 to 7404 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 4, catalyst middle DODGE_EXH_GAS_T_4_SCR_CAT
- Request
22 A0 C6 - Service 22
DID A0C6 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust gas temperature 5 – SCR CAT outlet DODGE_EXH_GAS_T_5_SCR_CAT
- Request
22 A0 C8 - Service 22
DID A0C8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 2020.
Exhaust temperature, downstream of exhaust manifold DODGE_EXH_T_DN_EXH
- Request
22 01 7E - Service 22
DID 017E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549.94 to 3003.56 °C
- Unit
- °C
In testing for 1988 to 2020.
Exhaust temperature, EGR cooler downstream DODGE_EXH_T_EGR_COOLER_DN
- Request
22 01 7E - Service 22
DID 017E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549.94 to 3003.56 °C
- Unit
- °C
In testing for 1988 to 2020.
Exhaust temperature, upstream of exhaust manifold DODGE_EXH_T_UP_EXH
- Request
22 01 7E - Service 22
DID 017E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549.94 to 3003.56 °C
- Unit
- °C
In testing for 1988 to 2020.
Expected generator supplier identifier of the reversible generator DODGE_EXPECTED_GEN
- Request
22 D7 89 - Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Expected identifier of electronic power circuit of reversible generator generator DODGE_EXPECTED_IDENTIFIER_ELECTRONIC
- Request
22 D7 88 - Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Expected identifier of reversible generator DODGE_EXPECTED_IDENTIFIER
- Request
22 D7 87 - Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Fuel correction cylinder 1 DODGE_FUEL_CORR_CYL1
- Request
22 38 00 - Service 22
DID 3800 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -5 to 5 mg/stroke
- Unit
- mg/stroke
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Fuel correction cylinder 2 DODGE_FUEL_CORR_CYL2
- Request
22 38 01 - Service 22
DID 3801 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -5 to 5 mg/stroke
- Unit
- mg/stroke
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Fuel correction cylinder 3 DODGE_FUEL_CORR_CYL3
- Request
22 38 02 - Service 22
DID 3802 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -5 to 5 mg/stroke
- Unit
- mg/stroke
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Fuel correction cylinder 4 DODGE_FUEL_CORR_CYL4
- Request
22 38 03 - Service 22
DID 3803 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -5 to 5 mg/stroke
- Unit
- mg/stroke
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Fuel rail pressure commanded DODGE_RAIL_PRESS_CMD
- Request
22 19 46 - Service 22
DID 1946 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3000 bar
- Unit
- bar
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Fuel rail pressure measured DODGE_RAIL_PRESS
- Request
22 19 47 - Service 22
DID 1947 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3000 bar
- Unit
- bar
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
FUGITIVE TRIP IN EMERGENCY MODE DODGE_FUGITIVE_TRIP
- Request
22 D6 71 - Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Generator mode DODGE_GEN_MODE
- Request
22 D7 14 - Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 75)- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 1988 to 2020.
Generator shutdown DODGE_GEN_SHUTDOWN
- Request
22 D7 5B - Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Glow plug plug set temperature DODGE_PREHEATING_T
- Request
22 D5 0F - Service 22
DID D50F - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 1988 to 2020.
Glow plug relay status DODGE_STAT_PRE_POST
- Request
22 D5 0D - Service 22
DID D50D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
IAT post-intercooler DODGE_IAT_TURBO
- Request
22 19 35 - Service 22
DID 1935 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Identifier of the electronic power circuit of the reversible generator DODGE_IDENTIFIER
- Request
22 D7 32 - Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Identifier of the supplier of the reversible generator DODGE_IDENTIFIER_SUPPLIER
- Request
22 D7 33 - Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Immobilizer code programming status DODGE_IMMOBILIZER_CODE
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Indicated engine torque DODGE_INDICATED_ENG_TQ
- Request
22 D4 D2 - Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Injection pulse, cylinder 1 DODGE_INJ_CYL_1
- Request
22 02 34 - Service 22
DID 0234 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Raw value
In testing for 1988 to 2020.
Injection pulse, cylinder 2 DODGE_INJ_CYL_2
- Request
22 02 35 - Service 22
DID 0235 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Raw value
In testing for 1988 to 2020.
Injection pulse, cylinder 3 DODGE_INJ_CYL_3
- Request
22 02 36 - Service 22
DID 0236 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Raw value
In testing for 1988 to 2020.
Injection pulse, cylinder 4 DODGE_INJ_CYL_4
- Request
22 02 37 - Service 22
DID 0237 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Raw value
In testing for 1988 to 2020.
Injector code 1 DODGE_INJ_CODE_1
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 47 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 1988 to 2020.
Injector code 2 DODGE_INJ_CODE_2
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 72 to 111 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 1988 to 2020.
Injector code 3 DODGE_INJ_CODE_3
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 136 to 175 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 1988 to 2020.
Injector code 4 DODGE_INJ_CODE_4
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 200 to 239 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 1988 to 2020.
Injector pulse width, cylinder 1 DODGE_INJ_WIDTH_CYL_1
- Request
22 02 34 - Service 22
DID 0234 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1988 to 2020.
Injector pulse width, cylinder 2 DODGE_INJ_WIDTH_CYL_2
- Request
22 02 35 - Service 22
DID 0235 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1988 to 2020.
Injector pulse width, cylinder 3 DODGE_INJ_WIDTH_CYL_3
- Request
22 02 36 - Service 22
DID 0236 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1988 to 2020.
Injector pulse width, cylinder 4 DODGE_INJ_WIDTH_CYL_4
- Request
22 02 37 - Service 22
DID 0237 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1988 to 2020.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Intake camshaft 1 to crankshaft offset DODGE_INT_CAM_1_OFFSET
- Request
22 06 C2 - Service 22
DID 06C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1988 to 2020.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Intake manifold air pressure DODGE_MAP
- Request
22 01 74 - Service 22
DID 0174 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Intake manifold air temperature DODGE_IAT_01FF
- Request
22 01 FF - Service 22
DID 01FF - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 2020.
Intake manifold air temperature DODGE_IAT_1935
- Request
22 19 35 - Service 22
DID 1935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 40)- Range
- -40 to 65495 °F
- Unit
- °F
In testing for 1988 to 2020.
Intake manifold air temperature DODGE_IAT_70B8
- Request
22 70 B8 - Service 22
DID 70B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0198412698 − 40)- Range
- -40 to 1260.2976 °C
- Unit
- °C
In testing for 1988 to 2020.
Inverter temperature estimated DODGE_INVERTER_T_ESTIMATED
- Request
22 DC 6A - Service 22
DID DC6A - Module
6A6 → 686 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 1988 to 2020.
Inverter temperature, commanded DODGE_INVERTER_T_CMD
- Request
22 DC 04 - Service 22
DID DC04 - Module
6A6 → 686 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 1988 to 2020.
Knock sensor 1 DODGE_KNOCK_SENS_1
- Request
22 01 A9 - Service 22
DID 01A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2020.
Knock sensor 2 DODGE_KNOCK_SENS_2
- Request
22 01 AA - Service 22
DID 01AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 2020.
Line pressure DODGE_LINE_P
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2020.
Line pressure duty cycle DODGE_LINE_P_DUTY
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 655)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2020.
Line pressure solenoid valve control current DODGE_SLT_LINE_P_VARIATION
- Request
22 D6 06 - Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2020.
Lock status DODGE_LOCK_STAT
- Request
22 DA DD - Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed
- Request
01 09 - Service 01
PID 09 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Long-term regeneration capability DODGE_LONG_TERM_REGEN
- Request
22 D5 4D - Service 22
DID D54D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2020.
Low side coolant temperature DODGE_LOW_SIDE_ECT
- Request
22 12 C9 - Service 22
DID 12C9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 2020.
M-Prop injection command DODGE_MPROP_CMD
- Request
22 18 D0 - Service 22
DID 18D0 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Mass airflow sensor temperature DODGE_MAF_TEMP
- Request
22 19 3F - Service 22
DID 193F - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Mass of urea injected for thermal protection of urea injector DODGE_MASS_UREA_INJECTED
- Request
22 D5 6B - Service 22
DID D56B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50.00000112)- Range
- 0 to 1310 g
- Unit
- g
In testing for 1988 to 2020.
Maximum allowable torque DODGE_MAX_ALLOWABLE_TQ
- Request
22 D5 06 - Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 DODGE_MEAS_CURRENT_P_B2
- Request
22 D6 23 - Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2020.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 DODGE_MEAS_CURRENT_P_B1
- Request
22 D6 09 - Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2020.
Measured line pressure variation solenoid valve current DODGE_MEAS_LINE_P
- Request
22 D6 07 - Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 2020.
Mileage remaining before diesel particulate filter replacement DODGE_MILEAGE_REMAINING
- Request
22 D5 30 - Service 22
DID D530 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 16)- Range
- -524288 to 524272 km
- Unit
- km
In testing for 1988 to 2020.
Mileage since last diesel particulate filter replacement DODGE_MILEAGE_SINCE_DPF
- Request
22 D5 31 - Service 22
DID D531 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8)- Range
- 0 to 524280 km
- Unit
- km
In testing for 1988 to 2020.
Mileage since last oil change DODGE_MILEAGE_SINCE_OIL
- Request
22 D4 3F - Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 1988 to 2020.
Minimum cell capacity DODGE_MIN_CELL_CAP
- Request
22 D4 13 - Service 22
DID D413 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 1988 to 2020.
Mixture enrichment measured by nox sensor at inlet DODGE_MIXTURE_ENRICHMENT
- Request
22 D5 71 - Service 22
DID D571 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 2020.
Mixture enrichment measured by nox sensor at outlet DODGE_MIXTURE_ENRICHMENT_MEAS
- Request
22 D5 5B - Service 22
DID D55B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 2020.
Movement of controlled air supply module DODGE_MOVEMENT_CONTROLLED
- Request
22 D4 EB - Service 22
DID D4EB - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Multi-displacement system active DODGE_MDS_ACTIVE
- Request
22 0E CA - Service 22
DID 0ECA - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2020.
Neutral position sensor status DODGE_NEUTRAL_POS_SENS
- Request
22 D4 38 - Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Nitrogen oxides at exhaust treatment intake DODGE_AFTERTREATMENT_INT
- Request
22 A1 14 - Service 22
DID A114 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 1988 to 2020.
Nitrogen oxides at exhaust treatment outlet DODGE_AFTERTREATMENT
- Request
22 A1 1A - Service 22
DID A11A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 1988 to 2020.
Nox sensor heating control DODGE_NOX_SENS_HEATING
- Request
22 D5 54 - Service 22
DID D554 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Nox sensor signal status at the inlet DODGE_NOX_SENS_SIG_STAT_INLET
- Request
22 D5 72 - Service 22
DID D572 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Nox sensor signal status at the outlet DODGE_NOX_SENS_SIG_STAT
- Request
22 D5 73 - Service 22
DID D573 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Nox system operating status DODGE_NOX_SYSTEM_OP_STAT
- Request
22 D5 40 - Service 22
DID D540 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Number of engine stop information deletion cycles DODGE_NUM_ENG_STOP
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Oil pressure DODGE_OIL_P
- Request
22 D4 29 - Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 1988 to 2020.
Oil pressure reference value DODGE_OIL_P_REFERENCE
- Request
22 D4 64 - Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 1988 to 2020.
Oil pressure regulation control DODGE_OIL_P_REGULATION
- Request
22 D4 3B - Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 1988 to 2020.
Oil temperature DODGE_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 D4 7D - Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 2020.
Oil temperature DODGE_OIL_TEMEPRATURE
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1988 to 2020.
Open loop soot load assessment of the diesel particulate filter DODGE_OPEN_LOOP_SOOT_LOAD
- Request
22 D5 4A - Service 22
DID D54A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1024)- Range
- 0 to 63.99 g/L
- Unit
- g/L
In testing for 1988 to 2020.
Outside air temperature DODGE_AAT_6A8
- Request
22 D4 14 - Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 2020.
Particulate filter differential pressure DODGE_PF_DIFF_P
- Request
22 D5 20 - Service 22
DID D520 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 2020.
Particulate filter regeneration count DODGE_DPF_REGENS_5089
- Request
22 50 89 - Service 22
DID 5089 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Number
In testing for 1988 to 2020.
Power consumed for heating the pipelines of the urea injection system DODGE_POWER_CONSUMED
- Request
22 D5 80 - Service 22
DID D580 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 %
- Unit
- %
In testing for 1988 to 2020.
Power spent on heating the urea injection system pipes, percentage ratio DODGE_POWER_SPENT_ON
- Request
22 D5 3C - Service 22
DID D53C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 163.8399875)- Range
- 0 to 399 %
- Unit
- %
In testing for 1988 to 2020.
Powertrain condition DODGE_POWERTRAIN_COND
- Request
22 D4 BA - Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Preheating relay control DODGE_PREHEATING_RELAY
- Request
22 D5 0C - Service 22
DID D50C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 2020.
Presence of the identifier of the reversible generator DODGE_PRESENCE_IDENTIFIER
- Request
22 D7 31 - Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Pressure in the particulate filter DODGE_P_PF
- Request
22 01 7B - Service 22
DID 017B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 2020.
Pressure-based injection permission for urea solution DODGE_P_BASED_INJ
- Request
22 D5 14 - Service 22
DID D514 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Problems detected while transmitting unlock code DODGE_PROBLEMS_DETECTED
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Problems detected while transmitting unlock code DODGE_PROBLEMS_DETECTED_WHILE
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Real engine torque DODGE_REAL_ENG_TQ
- Request
22 D5 54 - Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Regen enable, on/off – alternative DODGE_REGEN_ENABLE_ON_OFF
- Request
21 D8 - Service 21
PID D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 95 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2020.
Regeneration active DODGE_DPF_REGEN_ACTIVE
- Request
22 50 AF - Service 22
DID 50AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
In testing for 1988 to 2020.
Regeneration enable DODGE_REGEN_ENABLE
- Request
22 D5 28 - Service 22
DID D528 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Remaining urea solution in the urea tank DODGE_REMAINING_UREA
- Request
22 D5 17 - Service 22
DID D517 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 125 ÷ 128)- Range
- 0 to 63999
- Unit
- Raw value
In testing for 1988 to 2020.
Remote wake-up circuit status DODGE_REMOTE_WAKE_UP
- Request
22 D7 05 - Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Remote wake-up state DODGE_REMOTE_WAKE_UP_ST
- Request
22 D7 08 - Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Request to turn on the engine diagnostic indicator DODGE_REQ_TURN_ON_ENG
- Request
22 D5 11 - Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Requested value controlled thermostat DODGE_REQ_CONTROLLED
- Request
22 D5 86 - Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 81.92000625)- Range
- -399 to 399 %
- Unit
- %
In testing for 1988 to 2020.
Restart request sent by power steering computer DODGE_RESTART_REQ_SENT
- Request
22 D7 0C - Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Restart request sent by suspension computer DODGE_RESTART_REQ_SENT_SUSPENSION
- Request
22 D7 0E - Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Return to engine start and restart control by starter DODGE_RETURN_ENG_START
- Request
22 D7 64 - Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Return to starter engine restart control DODGE_RETURN_STARTER_ENG
- Request
22 D7 61 - Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Reverse generator status DODGE_REVERSE_GEN_STAT
- Request
22 D7 16 - Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Reversible generator torque DODGE_REVERSIBLE_GEN_TQ
- Request
22 D7 15 - Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Sensed oil pressure DODGE_SENSED_OIL_P
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 2020.
Sensed pressure particulate filter downstream DODGE_SENSED_P_PF_DN
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 2020.
Service network related engine restart request DODGE_SERVICE_NETWORK
- Request
22 D7 4B - Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2013, 2016 to 2017. Supported for 2012, 2018 to 2020.
Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 08 - Service 01
PID 08 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2013, 2016 to 2017. Supported for 2012, 2018 to 2020.
Short term knock retard DODGE_SHORT_TERM_KNOCK
- Request
22 01 AE - Service 22
DID 01AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 °
- Unit
- °
In testing for 1988 to 2020.
Short-term regeneration capability DODGE_SHORT_TERM_REGEN
- Request
22 D5 4C - Service 22
DID D54C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2020.
Simulated particulate mass, stored DODGE_DPF_SIM_MASS
- Request
22 01 E2 - Service 22
DID 01E2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 1988 to 2020.
Soot clogging level of diesel particulate filter DODGE_SOOT_CLOGGING_LEVEL
- Request
22 D5 2F - Service 22
DID D52F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10.24)- Range
- 0 to 6399 %
- Unit
- %
In testing for 1988 to 2020.
Soot load DODGE_SOOT_LOAD
- Request
21 4D - Service 21
PID 4D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 g
- Unit
- g
In testing for 1988 to 2020.
Soot load based on delta pressure DODGE_SOOT_LOAD_BASED_ON_P
- Request
21 57 - Service 21
PID 57 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 100 + 32)- Range
- 0 to 34.55
- Unit
- Raw value
In testing for 1988 to 2020.
Soot mass flow in exhaust gas after combustion DODGE_SOOT_MASS_FLOW_EXH
- Request
22 01 7A - Service 22
DID 017A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 223 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -21474836 to 21474836
- Unit
- Raw value
In testing for 1988 to 2020.
Soot mass load DODGE_SOOT_MASS_LOAD
- Request
22 50 8D - Service 22
DID 508D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 650)- Range
- 0 to 100.823 %
- Unit
- %
In testing for 1988 to 2020.
Specified volume of injected urea solution DODGE_SPEC_VOLUME_INJECTED
- Request
22 D5 50 - Service 22
DID D550 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023
- Unit
- Raw value
In testing for 1988 to 2020.
Sport mode contactor state DODGE_SPORT_MODE_CONTACTOR
- Request
22 D5 03 - Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Start inhibit control, wired DODGE_START_INHIBIT_CTRL
- Request
22 D7 67 - Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Start or restart inhibition transmitted by engine management computer DODGE_START_OR_RESTART
- Request
22 D7 1E - Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Start prohibition DODGE_START_PROHIBITION
- Request
22 D5 1B - Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Starter activation counter DODGE_STARTER_ACTIVATION
- Request
22 D7 1F - Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 2020.
Starter control interface unit operating status DODGE_STARTER_CTRL
- Request
22 D7 2A - Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Starter duty cycle DODGE_STARTER_DUTY
- Request
22 D4 78 - Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 s
- Unit
- s
In testing for 1988 to 2020.
Starter engagement status DODGE_STARTER_ENGAGEMENT
- Request
22 D4 C3 - Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
State lock/unlock control unit DODGE_ST_LOCK_UNLOCK_CTRL
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Status of internal ignition motor DODGE_STAT_INTERNAL_IGN
- Request
22 D4 12 - Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Status of the energy accumulator DODGE_STAT_ENERGY
- Request
22 D7 22 - Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2020.
Stop allowed by ESP computer DODGE_STOP_ALLOWED_ESP
- Request
22 D7 06 - Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Stop and start function state DODGE_STOP_START_FUNCTION
- Request
22 D7 25 - Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Stop and start switch DODGE_STOP_START_SWITCH
- Request
22 D7 26 - Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Stop permitted by suspension computer DODGE_STOP_PERMITTED
- Request
22 D7 07 - Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Swirl actuator command DODGE_SWIRL_CMD
- Request
22 18 9B - Service 22
DID 189B - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -100 to 100 %
- Unit
- %
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Temperature before catalyst DODGE_T_BEFORE_CAT
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273.14 to 6280.36 °C
- Unit
- °C
In testing for 1988 to 2020.
Temperature before diesel particulate filter DODGE_T_BEFORE_DPF
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273.14 to 6280.36 °C
- Unit
- °C
In testing for 1988 to 2020.
Temperature before turbine DODGE_T_BEFORE_TURBINE
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273.14 to 6280.36 °C
- Unit
- °C
In testing for 1988 to 2020.
Temperature difference between the hottest and the coolest cells DODGE_T_DIFF_HOTEST
- Request
22 D8 78 - Service 22
DID D878 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 1988 to 2020.
Temperature of the energy accumulator DODGE_T_ENERGY_ACCUMULATOR
- Request
22 D7 21 - Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 1988 to 2020.
Temperature of the urea solution in the urea tank DODGE_T_UREA_SOLUTION_UREA
- Request
22 D5 6D - Service 22
DID D56D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1988 to 2020.
The composition of the mixture is calculated by the oxygen sensor DODGE_COMPOSITION_MIXTURE
- Request
22 D5 70 - Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 2020.
Throttle inlet air temperature filtered DODGE_THROTTLE_INLET_AIR_T
- Request
22 14 B1 - Service 22
DID 14B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 2020.
Throttle inlet air temperature raw DODGE_THROTTLE_INLET_AIR_T_RAW
- Request
22 14 B3 - Service 22
DID 14B3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 2020.
Throttle inlet pressure DODGE_THROTTLE_INLET_P
- Request
22 12 47 - Service 22
DID 1247 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 160)- Range
- 0 to 409.5937 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Time since active regen DODGE_TIME_SINCE_ACTIVE
- Request
22 A0 03 - Service 22
DID A003 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 1988 to 2020.
Time since regen started DODGE_TIME_SINCE_REGEN
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638 s
- Unit
- s
In testing for 1988 to 2020.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2013, 2017. Supported for 2012, 2016, 2018 to 2020.
Torque corresponding to driver requirement DODGE_TQ_CORRESPONDING
- Request
22 D4 E3 - Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Torque supplied or taken by generator DODGE_TQ_SUPPLIED_OR_TAKEN
- Request
22 D7 28 - Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 1988 to 2020.
Total mass of additive accumulated in the diesel particulate filter DODGE_TOT_MASS_ADDITIVE
- Request
22 D5 26 - Service 22
DID D526 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 g
- Unit
- g
In testing for 1988 to 2020.
Total mass of additive accumulated in the diesel particulate filter DODGE_TOT_MASS_ADDITIVE_ACCUMULATED_DPF
- Request
22 D5 27 - Service 22
DID D527 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047 g
- Unit
- g
In testing for 1988 to 2020.
Total mileage DODGE_ODO_6A8
Pelican can show this parameter as the odometer.
- Request
22 D4 9C - Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 1988 to 2020.
Total number of started regeneration events DODGE_TOT_NUM_STARTED
- Request
22 18 E7 - Service 22
DID 18E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 1988 to 2020.
Towing device configured DODGE_CAN_VEH_BE_EQUIPPED
- Request
22 D5 57 - Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Traction circuit coolant temperature DODGE_TRACTION_CIRCUIT_ECT
- Request
22 D8 F9 - Service 22
DID D8F9 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 1988 to 2020.
Traction or stability control regulating DODGE_ASR_OR_ESP_SYSTEM
- Request
22 D5 12 - Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Transmission fluid temperature DODGE_ATF_T_V3
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 2020.
Transmission main cylinder pressure DODGE_MAIN_CYL_P
- Request
22 50 34 - Service 22
DID 5034 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513 bar
- Unit
- bar
In testing for 1988 to 2020.
Turbine upstream temperature DODGE_TURBINE_UP_T
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273.14 to 6280.36 °C
- Unit
- °C
In testing for 1988 to 2020.
Turbo boost pressure DODGE_BOOST
- Request
22 19 5A - Service 22
DID 195A - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 3276.8)- Range
- -100 to 300 kPa
- Unit
- kPa
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Turbo compressor inlet temperature DODGE_TURBO_COMP_INLET_T
- Request
22 A0 EC - Service 22
DID A0EC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 36 ÷ 5 + 32)- Range
- 0 to 1868 °F
- Unit
- °F
In testing for 1988 to 2020.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2017.
Urea mass fraction DODGE_UREA_MASS_FRACTION
- Request
22 D5 8C - Service 22
DID D58C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 1988 to 2020.
Urea solution injected amount DODGE_UREA_SOLUTION
- Request
22 D5 68 - Service 22
DID D568 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023
- Unit
- Raw value
In testing for 1988 to 2020.
Urea solution injection permission based on temperature value DODGE_UREA_SOLUTION_INJ_ON_T
- Request
22 D5 15 - Service 22
DID D515 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Urea solution pressure DODGE_UREA_SOLUTION_P
- Request
22 D5 3E - Service 22
DID D53E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 bar
- Unit
- bar
In testing for 1988 to 2020.
Urea solution type in urea tank DODGE_UREA_SOLUTION_TYPE
- Request
22 D5 8D - Service 22
DID D58D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Urea tank heating current DODGE_UREA_TANK_HEATING
- Request
22 D5 81 - Service 22
DID D581 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 %
- Unit
- %
In testing for 1988 to 2020.
Urea tank heating current, percentage DODGE_UREA_TANK_HEATING_CURRENT
- Request
22 D5 1E - Service 22
DID D51E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 163.8399875)- Range
- 0 to 399 %
- Unit
- %
In testing for 1988 to 2020.
Vacuum circuit vacuum DODGE_VACUUM_CIRCUIT
- Request
22 D7 3B - Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1988 to 2020.
Value during generator load smooth increase DODGE_DURING_GEN_LOAD
- Request
22 D7 53 - Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Variable geometry turbo actuator, commanded position DODGE_VGT_CMD_189F
- Request
22 18 9F - Service 22
DID 189F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 39 ÷ 50 − 100)- Range
- -100 to 98.9 %
- Unit
- %
In testing for 1988 to 2020.
Variable geometry turbo actuator, commanded position DODGE_VGT_CMD_507B
- Request
22 50 7B - Service 22
DID 507B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 39 ÷ 50 − 100)- Range
- -100 to 98.9 %
- Unit
- %
In testing for 1988 to 2020.
Variable geometry turbo compressor inlet air temperature DODGE_VGT_COMP_INLET_AIR_T
- Request
21 DA - Service 21
PID DA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 9 ÷ 20 + 32)- Range
- 0 to 29522 °F
- Unit
- °F
In testing for 1988 to 2020.
Variable geometry turbo compressor outlet air temperature DODGE_VGT_COMP_OULET_AIR_T
- Request
21 DA - Service 21
PID DA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 9 ÷ 20 + 32)- Range
- 0 to 29522 °F
- Unit
- °F
In testing for 1988 to 2020.
Variable oil pump position DODGE_OIL_PUMP
- Request
22 19 4F - Service 22
DID 194F - Module
DA10 → 10 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Variable valve timing oil pressure DODGE_VARIABLE_VLV_TIM_OIL_P
- Request
22 06 9E - Service 22
DID 069E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Variable valve timing oil temperature DODGE_VARIABLE_VLV_TIM_OIL_T
- Request
22 06 9F - Service 22
DID 069F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 2020.
Vehicle hour meter DODGE_VEH_HOUR_METER
- Request
22 D8 01 - Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
In testing for 1988 to 2020.
Vehicle mileage remaining before filling the tank with urea solution DODGE_VEH_MILEAGE
- Request
22 D5 13 - Service 22
DID D513 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 km
- Unit
- km
In testing for 1988 to 2020.
Vehicle mileage since the last oil change under severe vehicle operating conditions DODGE_VEH_MILEAGE_SINCE
- Request
22 D5 34 - Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 1988 to 2020.
VGT position actual DODGE_VGT_ACT
- Request
22 18 A0 - Service 22
DID 18A0 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
VGT position commanded DODGE_VGT_CMD
- Request
22 18 9F - Service 22
DID 189F - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2011, 2014 to 2015, 2018 to 2020. Not supported for 2012 to 2013, 2016 to 2017.
Volume of urea solution measured in urea tank DODGE_VOLUME_UREA_SOLUTION
- Request
22 D5 58 - Service 22
DID D558 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 L
- Unit
- L
In testing for 1988 to 2020.
Wastegate position sensor DODGE_WASTEGATE_POS_SENS
- Request
22 1F 59 - Service 22
DID 1F59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 61 ÷ 12500)- Range
- 0 to 319.8107 V
- Unit
- V
In testing for 1988 to 2020.
Water in diesel DODGE_WATER_DIESEL
- Request
22 D5 2C - Service 22
DID D52C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.
Winter mode switch state DODGE_WINTER_MODE_SWITCH
- Request
22 D5 02 - Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2020.