Genesis GV60

Battery parameters

The Genesis GV60 has 328 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Auxiliary battery voltage GV60_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 E0 04
  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

0x6EE1 = 28385 → (28385 × 4.883 ÷ 10000) = 13.860396 V

Formula
(val × 4.883 ÷ 10000)
Range
0 to 32 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C charger current GV60_AC_CHARGER_CURRENTConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 304 to 319 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0 A

Formula
(val ÷ 100)
Range
0 to 655.35 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

A/C charging counter GV60_HVBAT_AC_CHARGING_COUNTERConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 240 to 255 of the reply, 16 bits.

0x004F = 79 → 79

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

A/C charging time GV60_VCMS__AC_CHARGING_TIMEConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 272 to 287 of the reply, 16 bits.

0x0115 = 277 → 277 h

Formula
val
Range
0 to 65535 h
Unit
h

Confirmed for 2023. In testing for 2022, 2024 to 2026.

A/C charging time, after plug-in GV60_AC_CHARGING_TIME_AFTER_PLUG_INConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 336 to 351 of the reply, 16 bits.

0x0000 = 0 → 0 min

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Auxiliary battery current GV60_2025_AUX_BATTERY_CURRENT

  • Request22 E1 01
  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 100 − 327)
Range
-327 to 328.35 A
Unit
A

In testing for 2022, 2024 to 2026. Not supported for 2023.

Auxiliary battery current GV60_AUX_BATTERY_CURRENTConfirmed

  • Request22 E0 11
  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 159 of the reply, 16 bits.

0x850F = 34063 → (34063 ÷ 100 − 327) = 13.63 A

Formula
(val ÷ 100 − 327)
Range
-327 to 328.35 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Auxiliary battery state of charge GV60_2025_AUX_BATTERY_STATE_OF_CHARGE

  • Request22 E1 01
  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2022, 2024 to 2026. Not supported for 2023.

Auxiliary battery state of charge GV60_AUX_BATTERY_STATE_OF_CHARGEConfirmed

  • Request22 E0 11
  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits.

0x53 = 83 → 83 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Auxiliary battery temperature GV60_2025_AUX_BATTERY_T

  • Request22 E1 01
  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 32727.5 °C
Unit
°C

In testing for 2022, 2024 to 2026. Not supported for 2023.

Auxiliary battery temperature GV60_AUX_BATTERY_TConfirmed

  • Request22 E0 11
  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 199 of the reply, 16 bits.

0x006D = 109 → (109 ÷ 2 − 40) = 14.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 32727.5 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Auxiliary battery voltage GV60_12V_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 E0 04
  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

0x6EE1 = 28385 → (28385 × 4.883 ÷ 10000) = 13.860396 V

Formula
(val × 4.883 ÷ 10000)
Range
0 to 32 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Auxiliary battery voltage GV60_2025_AUX_BATTERY_VOLTAGE

Pelican can show this parameter as the starter battery voltage.

  • Request22 E1 01
  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
(val ÷ 1000 + 6)
Range
6 to 71.535 V
Unit
V

In testing for 2022, 2024 to 2026. Not supported for 2023.

Auxiliary battery voltage GV60_AUX_BATTERY_VOLTAGE_7E5Confirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 E0 11
  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 183 of the reply, 16 bits.

0x1FBA = 8122 → (8122 ÷ 1000 + 6) = 14.122 V

Formula
(val ÷ 1000 + 6)
Range
6 to 71.535 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Auxiliary battery voltage GV60_AUXILLARY_BATTERY_VOLTAGEConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 232 to 239 of the reply, 8 bits.

0x7C = 124 → (124 ÷ 10) = 12.4 V

Formula
(val ÷ 10)
Range
11 to 14.6 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery current GV60_BATTERY_CURRENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 95 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
-230 to 230 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery DC voltage GV60_BATTERY_DC_VOLTAGEConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 111 of the reply, 16 bits.

0x1B22 = 6946 → (6946 ÷ 10) = 694.6 V

Formula
(val ÷ 10)
Range
0 to 1000 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery fan duty feedback GV60_HVBAT_FAN_DUTYConfirmed

  • Request22 01 06
  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery fan feedback GV60_BATTERY_FAN_FEEDBACKConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0x00 = 0 → 0 Hz

Formula
val
Range
0 to 120 Hz
Unit
Hz

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery fan status GV60_BATTERY_FAN_STATUSConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 9
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery inlet temperature GV60_BATTERY_INLET_TConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0x3F = 63 → (63 − 40) = 23 °C

Formula
(val − 40)
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery management state GV60_BMS_STATEConfirmed

  • Request22 01 06
  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery management system ignition GV60_BMS_IGNITIONConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 405 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery management system main relay GV60_BMS_MAIN_RELAYConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 79 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery max temperature GV60_BATTERY_MAX_TConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

0x16 = 22 → 22 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery min temperature GV60_BATTERY_MIN_TConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

0x15 = 21 → 21 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery pack B01 GV60_BATTERY_PACK_B01Confirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 135 of the reply, 8 bits. The value is signed.

0x16 = 22 → 22 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery pack B02 GV60_BATTERY_PACK_B02Confirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 143 of the reply, 8 bits. The value is signed.

0x16 = 22 → 22 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery pack B03 GV60_BATTERY_PACK_B03Confirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 151 of the reply, 8 bits. The value is signed.

0x15 = 21 → 21 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery pack B04 GV60_BATTERY_PACK_B04Confirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 159 of the reply, 8 bits. The value is signed.

0x16 = 22 → 22 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery pack B05 GV60_BATTERY_PACK_B05Confirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

0x15 = 21 → 21 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery pack B17 GV60_BATTERY_PACK_B17Confirmed

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 215 of the reply, 8 bits. The value is signed.

0x11 = 17 → 17 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery pack B18 GV60_BATTERY_PACK_B18Confirmed

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits. The value is signed.

0x11 = 17 → 17 °C

Formula
val
Range
-40 to 80 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery temperature at the power relay assembly GV60_HVBAT_PRA_TConfirmed

  • Request22 01 06
  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

0x06 = 6 → (6 × 2) = 12 °C

Formula
(val × 2)
Range
-256 to 254 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery temperature at WCS input GV60_HVBAT_WCS_INLET_TConfirmed

  • Request22 01 06
  • Service 22DID 0106
  • Module7E4 → 7EC
  • Every5 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits. The value is signed.

0x0E = 14 → 14 °C

Formula
val
Range
-128 to 127 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery work time total GV60_BATTERY_WORK_TIME_TOTAL_SECConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 368 to 399 of the reply, 32 bits.

0x02A4E61E = 44361246 → 44,361,246 s

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Charge mode A/C maximum current limit GV60_CHARGE_MODE_AC_MAXIMUM_CURRENT_LIMITConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 111 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Charge mode DC maximum current limit GV60_CHARGE_MODE_DC_MAXIMUM_CURRENT_LIMITConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 95 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Charge mode DC target voltage GV60_CHARGE_MODE_DC_TARGET_VOLTAGEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 79 of the reply, 16 bits.

0x2040 = 8256 → (8256 ÷ 10) = 825.6 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Charging? GV60_HV_CHARGINGConfirmed

Pelican can show this parameter as the charging state.

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 72 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Control pilot duty cycle GV60_HVBAT_CP_DUTY_CYCLEConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 71 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 %

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Control pilot voltage GV60_HVBAT_CP_VOLTAGEConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 55 of the reply, 8 bits.

0x5A = 90 → (90 ÷ 10) = 9 V

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Cumulative charge current GV60_CUMULATIVE_CHARGE_CURRENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 240 to 271 of the reply, 32 bits.

0x000459DE = 285150 → (285150 ÷ 10) = 28,515 Ah

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Cumulative DC charging time GV60_DC_CHRG_TIMEConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 288 to 303 of the reply, 16 bits.

0x007D = 125 → 125 h

Formula
val
Range
0 to 65535 h
Unit
h

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Cumulative discharge current GV60_CUMULATIVE_DISCHARGE_CURRENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 272 to 303 of the reply, 32 bits.

0x000433D2 = 275410 → (275410 ÷ 10) = 27,541 Ah

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Cumulative energy charged GV60_CUMULATIVE_ENERGY_CHARGEDConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 304 to 335 of the reply, 32 bits.

0x00034567 = 214375 → (214375 ÷ 10) = 21,437.5 kWh

Formula
(val ÷ 10)
Range
0 to 429496729.5 kWh
Unit
kWh

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Cumulative energy discharged GV60_CUMULATIVE_ENERGY_DISCHARGEDConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 336 to 367 of the reply, 32 bits.

0x00030065 = 196709 → (196709 ÷ 10) = 19,670.9 kWh

Formula
(val ÷ 10)
Range
0 to 429496729.5 kWh
Unit
kWh

Confirmed for 2023. In testing for 2022, 2024 to 2026.

DC charger current capability GV60_DC_CHARGER_CURRENT_CAPABILITYConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 320 to 335 of the reply, 16 bits.

0x0D02 = 3330 → (3330 ÷ 100) = 33.3 A

Formula
(val ÷ 100)
Range
0 to 655.35 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

DC charging counter GV60_HVBAT_CHRG_CNTConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 256 to 271 of the reply, 16 bits.

0x0133 = 307 → 307

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

DC charging time, after plug-in GV60_DC_CHARGING_TIME_AFTER_PLUG_INConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 352 to 367 of the reply, 16 bits.

0x001A = 26 → 26 min

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Discharge mode A/C maximum current limit GV60_DISCHARGE_MODE_AC_MAXIMUM_CURRENT_LIMITConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 143 of the reply, 8 bits.

0x00 = 0 → 0 A

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Discharge mode A/C target voltage GV60_DISCHARGE_MODE_V2L_AC_TARGET_VOLTAGEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits.

0x00 = 0 → 0 V

Formula
val
Range
0 to 255 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Discharge mode DC maximum current limit GV60_DISCHARGE_MODE_DC_MAXIMUM_CURRENT_LIMITConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 135 of the reply, 8 bits.

0x32 = 50 → 50 A

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric oil pump, actual speed GV60_EOP_ACTUAL_SPEEDConfirmed

  • Request22 E0 09
  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits.

0x00 = 0 → (0 × 20) = 0 rpm

Formula
(val × 20)
Range
0 to 5100 rpm
Unit
rpm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric oil pump, commanded speed GV60_EOP_COMMANDED_SPEEDConfirmed

  • Request22 E0 09
  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 159 of the reply, 8 bits.

0x00 = 0 → (0 × 20) = 0 rpm

Formula
(val × 20)
Range
0 to 5100 rpm
Unit
rpm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric oil pump, current DC GV60_EOP_CURRENT_DCConfirmed

  • Request22 E0 09
  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0x00 = 0 → 0 A

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric oil pump, current IQ GV60_EOP_CURRENT_IQConfirmed

  • Request22 E0 09
  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 191 of the reply, 8 bits.

0x00 = 0 → 0 A

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, target current GV60_HVBAT_TARGET_CURRConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 159 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric water pump, actual rotation speed GV60_EWP_ACTUAL_ROTATION_SPEEDConfirmed

  • Request22 E0 09
  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0x47 = 71 → (71 × 24) = 1,704 rpm

Formula
(val × 24)
Range
0 to 6120 rpm
Unit
rpm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric water pump, commanded rotation speed GV60_EWP_COMMANDED_ROTATION_SPEEDConfirmed

  • Request22 E0 09
  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 95 of the reply, 8 bits.

0x48 = 72 → (72 × 24) = 1,728 rpm

Formula
(val × 24)
Range
0 to 6120 rpm
Unit
rpm

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric water pump, current DC GV60_EWP_CURRENT_DCConfirmed

  • Request22 E0 09
  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 63 of the reply, 8 bits.

0x04 = 4 → (4 ÷ 10) = 0.4 A

Formula
(val ÷ 10)
Range
0 to 25.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric water pump, voltage DC GV60_EWP_VOLTAGE_DCConfirmed

  • Request22 E0 09
  • Service 22DID E009
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0x8C = 140 → (140 ÷ 10) = 14 V

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

High voltage battery, max current GV60_HVBAT_EV_MAX_CURRENTConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 191 of the reply, 16 bits.

0x0DAC = 3500 → (3500 ÷ 10) = 350 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

High voltage battery, max voltage GV60_HVBAT_EV_MAX_VOLTAGEConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 175 of the reply, 16 bits.

0x2040 = 8256 → (8256 ÷ 10) = 825.6 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

High voltage battery, state of charge GV60_HVBAT_SOC_VCMSConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 127 of the reply, 8 bits.

0xB4 = 180 → (180 ÷ 2) = 90 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

High voltage battery, target current GV60_HVBAT_BMS_TARGET_CURRENTConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 223 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

High voltage battery, target voltage GV60_HVBAT_BMS_TARGET_VOLTAGEConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 192 to 207 of the reply, 16 bits.

0x2040 = 8256 → (8256 ÷ 10) = 825.6 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

High voltage battery, target voltage GV60_HVBAT_TARGET_VOLTConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 143 of the reply, 16 bits.

0x2040 = 8256 → (8256 ÷ 10) = 825.6 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

High voltage battery, voltage GV60_HVBAT_HV_BATTERY_VOLTAGEConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 119 of the reply, 16 bits.

0x1EC9 = 7881 → (7881 ÷ 10) = 788.1 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

HV battery charge GV60_HVBAT_SOC_DISPConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 01 05
  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 248 to 255 of the reply, 8 bits.

0xA9 = 169 → (169 ÷ 2) = 84.5 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

HV battery charge, dashboard GV60_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0x46 = 70 → (70 ÷ 2) = 35 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

HV battery remaining energy GV60_HVBAT_WHConfirmed

  • Request22 01 05
  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 239 of the reply, 16 bits.

0x7750 = 30544 → (30544 × 2 ÷ 1000) = 61.088 kWh

Formula
(val × 2 ÷ 1000)
Range
0 to 100 kWh
Unit
kWh

Confirmed for 2023. In testing for 2022, 2024 to 2026.

HV battery state of health GV60_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Request22 01 05
  • Service 22DID 0105
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 215 of the reply, 16 bits.

0x03E8 = 1000 → (1000 ÷ 10) = 100 %

Formula
(val ÷ 10)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Inverter capacitor voltage GV60_INVERTER_CAPACITOR_VOLTAGEConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 408 to 423 of the reply, 16 bits.

0x01DF = 479 → 479 V

Formula
val
Range
0 to 500 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Isolation resistance GV60_ISOLATION_RESISTANCEConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Bits 456 to 471 of the reply, 16 bits.

Formula
val
Range
0 to 1000 kΩ
Unit
kΩ

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Low-voltage dc-dc converter, input voltage GV60_2025_LDC_INPUT_VOLTAGE

  • Request22 E1 01
  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

In testing for 2022, 2024 to 2026. Not supported for 2023.

Low-voltage dc-dc converter, input voltage GV60_LDC_INPUT_VOLTAGEConfirmed

  • Request22 E0 11
  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 127 of the reply, 16 bits.

0x1DC3 = 7619 → (7619 ÷ 10) = 761.9 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Low-voltage dc-dc converter, output current GV60_2025_LDC_OUTPUT_CURRENT

  • Request22 E1 01
  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val × 10 ÷ 1000)
Range
0 to 655.35 A
Unit
A

In testing for 2022, 2024 to 2026. Not supported for 2023.

Low-voltage dc-dc converter, output current GV60_LDC_OUTPUT_CURRENTConfirmed

  • Request22 E0 11
  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 111 of the reply, 16 bits.

0x13E5 = 5093 → (5093 × 10 ÷ 1000) = 50.93 A

Formula
(val × 10 ÷ 1000)
Range
0 to 655.35 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Low-voltage dc-dc converter, output voltage GV60_2025_LDC_OUTPUT_VOLTAGE

  • Request22 E1 01
  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2022, 2024 to 2026. Not supported for 2023.

Low-voltage dc-dc converter, output voltage GV60_LDC_OUTPUT_VOLTAGEConfirmed

  • Request22 E0 11
  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 95 of the reply, 16 bits.

0x3884 = 14468 → (14468 ÷ 1000) = 14.468 V

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Low-voltage dc-dc converter, temperature GV60_2025_LDC_T

  • Request22 E1 01
  • Service 22DID E101
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 °C
Unit
°C

In testing for 2022, 2024 to 2026. Not supported for 2023.

Low-voltage dc-dc converter, temperature GV60_LDC_TConfirmed

  • Request22 E0 11
  • Service 22DID E011
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0x77 = 119 → (119 − 100) = 19 °C

Formula
(val − 100)
Range
-100 to 155 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Maximum cell voltage GV60_MAXIMUM_CELL_VOLTAGEConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 191 of the reply, 8 bits.

0xB4 = 180 → (180 ÷ 50) = 3.6 V

Formula
(val ÷ 50)
Range
2.8 to 4.2 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Maximum cell voltage no GV60_MAXIMUM_CELL_VOLTAGE_NOConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 192 to 199 of the reply, 8 bits.

0x03 = 3 → 3

Formula
val
Range
0 to 98
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Minimum cell voltage GV60_MINIMUM_CELL_VOLTAGEConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0xB4 = 180 → (180 ÷ 50) = 3.6 V

Formula
(val ÷ 50)
Range
2.8 to 4.2 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Minimum cell voltage no GV60_MINIMUM_CELL_VOLTAGE_NOConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 98
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Normal charge port GV60_NORMAL_CHARGE_PORTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 74 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Normal charging energy, total GV60_NORMAL_CHARGING_ENERGY_TOTConfirmed

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 127 of the reply, 32 bits.

0x00000603 = 1539 → 1,539 kWh

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Normal charging, count GV60_NORMAL_CHARGING_COUNTConfirmed

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 63 of the reply, 32 bits.

0x00000070 = 112 → 112

Formula
val
Range
0 to 4294967295
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Proximity detection voltage GV60_HVBAT_PD_VOLTAGEConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 103 of the reply, 16 bits.

0x05D2 = 1490 → (1490 × 10 ÷ 10000) = 1.49 V

Formula
(val × 10 ÷ 10000)
Range
0 to 65.535 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Quick charging energy, total GV60_QUICK_CHARGING_ENERGY_TOTConfirmed

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 159 of the reply, 32 bits.

0x000015AC = 5548 → 5,548 kWh

Formula
val
Range
0 to 4294967295 kWh
Unit
kWh

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Quick charging, count GV60_QUICK_CHARGING_COUNTConfirmed

  • Request22 01 11
  • Service 22DID 0111
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 95 of the reply, 32 bits.

0x0000017F = 383 → 383

Formula
val
Range
0 to 4294967295
Unit
Number

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Rapid charge port GV60_RAPID_CHARGE_PORTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 73 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Charging

400V relay on/off request GV60_400V_RELAY_ON_OFF_REQUESTConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 43 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 2022, 2024 to 2026.

400V relay status GV60_400V_RELAY_STATUSConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 42 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 2022, 2024 to 2026.

AC charging state GV60_AC_CHRG_STATEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 141 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 2022, 2024 to 2026.

AC inlet temperature 1 GV60_AC_INLET_T_1Confirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0x42 = 66 → (66 − 50) = 16 °C

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Auxiliary battery voltage GV60_AUX_BATTERY_VOLTAGEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 103 of the reply, 16 bits.

0x04BB = 1211 → (1211 ÷ 100) = 12.11 V

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery main relay status GV60_BATTERY_MAIN_RELAY_STATUSConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 37 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Charging socket connected GV60_CHARGING_SOCKET_CONNECTEDConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 38 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 2022, 2024 to 2026.

DC charging state GV60_DC_CHRG_STATEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bit 140 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 2022, 2024 to 2026.

DC inlet temperature 1 GV60_DC_INLET_T_1Confirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0x42 = 66 → (66 − 50) = 16 °C

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

DC inlet temperature 2 GV60_DC_INLET_T_2Confirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0x42 = 66 → (66 − 50) = 16 °C

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, current GV60_EVSE_CConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 167 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, current, max GV60_EVSE_MAXIMUM_CURRENT_VALUEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 103 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, current, min GV60_EVSE_MINIMUM_CURRENT_VALUEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 135 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, power, delivered GV60_EVSE_DELIVERED_POWER_VALUEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 199 of the reply, 16 bits.

0x0000 = 0 → (0 × 10 ÷ 1000) = 0 kWh

Formula
(val × 10 ÷ 1000)
Range
0 to 655.35 kWh
Unit
kWh

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, power, main GV60_EVSE_MAIN_POWERConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0x00 = 0 → 0 kW

Formula
val
Range
0 to 255 kW
Unit
kW

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, power, max GV60_EVSE_MAXIMUM_POWER_VALUEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 215 of the reply, 16 bits.

0x0000 = 0 → (0 × 10) = 0 W

Formula
(val × 10)
Range
0 to 655350 W
Unit
W

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, regulation tolerance GV60_EVSE_CURRENT_REGULATION_TOLERANCE_VALUEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0x00 = 0 → (0 − 50) = -50 A

Formula
(val − 50)
Range
-50 to 205 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, voltage GV60_EVSE_VConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 151 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, voltage, max GV60_EVSE_MAXIMUM_VOLTAGE_VALUEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 87 of the reply, 16 bits.

0x0FA0 = 4000 → (4000 ÷ 10) = 400 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Electric vehicle supply equipment, voltage, min GV60_EVSE_MINIMUM_VOLTAGE_VALUEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module744 → 74C
  • Every250 ms
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 119 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Estimated charging power GV60_ESTIMATED_CHRG_POWERConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 239 of the reply, 16 bits.

0x0000 = 0 → (0 × 10 − 50) = -50 W

Formula
(val × 10 − 50)
Range
-50 to 655300 W
Unit
W

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, AC current a GV60_OBC_AC_CURRENT_A_RMSConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 119 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 100) = 0 A

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, AC current b GV60_OBC_AC_CURRENT_B_RMSConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 135 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 100) = 0 A

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, AC frequency GV60_OBC_AC_FREQUENCYConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0x00 = 0 → 0 Hz

Formula
val
Range
0 to 255 Hz
Unit
Hz

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, AC input current sensor a signal voltage GV60_OBC_AC_INPUT_CURRENT_SENSOR_A_SIGNAL_VOLTAGEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 296 to 311 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0 V

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, AC input current sensor b signal voltage GV60_OBC_AC_INPUT_CURRENT_SENSOR_B_SIGNAL_VOLTAGEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 312 to 327 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0 V

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, AC total current GV60_OBC_AC_TOTAL_CURRENT_RMSConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 103 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 100) = 0 A

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, AC voltage a GV60_OBC_AC_VOLTAGE_A_RMSConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 47 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, AC voltage b GV60_OBC_AC_VOLTAGE_B_RMSConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 63 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, charge mode DC target current GV60_OBC_CHARGE_MODE_DC_TARGET_CURRENTConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 95 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, charge mode DC target voltage GV60_OBC_CHARGE_MODE_DC_TARGET_VOLTAGEConfirmed

  • Request22 E0 03
  • Service 22DID E003
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 79 of the reply, 16 bits.

0x1B28 = 6952 → (6952 ÷ 10) = 695.2 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, charging AC current GV60_OBC_CHRG_AC_CURRENTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 199 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, charging AC voltage GV60_OBC_CHRG_AC_VOLTAGEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0x00 = 0 → 0 V

Formula
val
Range
0 to 255 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, charging DC current GV60_OBC_CHRG_DC_CURRENTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 183 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 A

Formula
(val ÷ 10)
Range
0 to 6553.5 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, charging DC voltage GV60_OBC_CHRG_DC_VOLTAGEConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 167 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, DC current a GV60_OBC_DC_CURRENT_A_RMSConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 199 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 100) = 0 A

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, DC current b GV60_OBC_DC_CURRENT_B_RMSConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 215 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 100) = 0 A

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, DC current total GV60_OBC_DC_CURRENT_TOTAL_RMSConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 183 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 100) = 0 A

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, DC voltage GV60_OBC_DC_VOLTAGEConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 167 of the reply, 16 bits.

0x1B1E = 6942 → (6942 ÷ 10) = 694.2 V

Formula
(val ÷ 10)
Range
0 to 6553.5 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, discharging AC current GV60_OBC_DCHRG_AC_CURRENTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0x00 = 0 → 0 A

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, discharging DC current GV60_OBC_DCHRG_DC_CURRENTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module744 → 74C
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 215 of the reply, 8 bits.

0x32 = 50 → 50 A

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, temperature a GV60_OBC_T_AConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0x42 = 66 → (66 − 40) = 26 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

On-board charger, temperature b GV60_OBC_T_BConfirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0x42 = 66 → (66 − 40) = 26 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 001

HV battery module 001 voltage GV60_HVBAT_CMU001_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 002

HV battery module 002 voltage GV60_HVBAT_CMU002_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 40 to 47 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 003

HV battery module 003 voltage GV60_HVBAT_CMU003_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 55 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 004

HV battery module 004 voltage GV60_HVBAT_CMU004_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 63 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 005

HV battery module 005 voltage GV60_HVBAT_CMU005_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 006

HV battery module 006 voltage GV60_HVBAT_CMU006_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 007

HV battery module 007 voltage GV60_HVBAT_CMU007_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 008

HV battery module 008 voltage GV60_HVBAT_CMU008_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 95 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 009

HV battery module 009 voltage GV60_HVBAT_CMU009_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 010

HV battery module 010 voltage GV60_HVBAT_CMU010_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 111 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 011

HV battery module 011 voltage GV60_HVBAT_CMU011_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 012

HV battery module 012 voltage GV60_HVBAT_CMU012_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 127 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 013

HV battery module 013 voltage GV60_HVBAT_CMU013_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 135 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 014

HV battery module 014 voltage GV60_HVBAT_CMU014_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 143 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 015

HV battery module 015 voltage GV60_HVBAT_CMU015_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 151 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 016

HV battery module 016 voltage GV60_HVBAT_CMU016_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 159 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 017

HV battery module 017 voltage GV60_HVBAT_CMU017_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 018

HV battery module 018 voltage GV60_HVBAT_CMU018_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 175 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 019

HV battery module 019 voltage GV60_HVBAT_CMU019_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 020

HV battery module 020 voltage GV60_HVBAT_CMU020_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 191 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 021

HV battery module 021 voltage GV60_HVBAT_CMU021_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 192 to 199 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 022

HV battery module 022 voltage GV60_HVBAT_CMU022_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 023

HV battery module 023 voltage GV60_HVBAT_CMU023_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 215 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 024

HV battery module 024 voltage GV60_HVBAT_CMU024_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 025

HV battery module 025 voltage GV60_HVBAT_CMU025_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 026

HV battery module 026 voltage GV60_HVBAT_CMU026_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 232 to 239 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 027

HV battery module 027 voltage GV60_HVBAT_CMU027_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 240 to 247 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 028

HV battery module 028 voltage GV60_HVBAT_CMU028_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 248 to 255 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 029

HV battery module 029 voltage GV60_HVBAT_CMU029_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 256 to 263 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 030

HV battery module 030 voltage GV60_HVBAT_CMU030_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 264 to 271 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 031

HV battery module 031 voltage GV60_HVBAT_CMU031_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 272 to 279 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 032

HV battery module 032 voltage GV60_HVBAT_CMU032_VOLTConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 280 to 287 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 033

HV battery module 033 voltage GV60_HVBAT_CMU033_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 034

HV battery module 034 voltage GV60_HVBAT_CMU034_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 40 to 47 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 035

HV battery module 035 voltage GV60_HVBAT_CMU035_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 55 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 036

HV battery module 036 voltage GV60_HVBAT_CMU036_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 63 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 037

HV battery module 037 voltage GV60_HVBAT_CMU037_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 038

HV battery module 038 voltage GV60_HVBAT_CMU038_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 039

HV battery module 039 voltage GV60_HVBAT_CMU039_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 040

HV battery module 040 voltage GV60_HVBAT_CMU040_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 95 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 041

HV battery module 041 voltage GV60_HVBAT_CMU041_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 042

HV battery module 042 voltage GV60_HVBAT_CMU042_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 111 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 043

HV battery module 043 voltage GV60_HVBAT_CMU043_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 044

HV battery module 044 voltage GV60_HVBAT_CMU044_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 127 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 045

HV battery module 045 voltage GV60_HVBAT_CMU045_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 135 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 046

HV battery module 046 voltage GV60_HVBAT_CMU046_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 143 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 047

HV battery module 047 voltage GV60_HVBAT_CMU047_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 151 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 048

HV battery module 048 voltage GV60_HVBAT_CMU048_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 159 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 049

HV battery module 049 voltage GV60_HVBAT_CMU049_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 050

HV battery module 050 voltage GV60_HVBAT_CMU050_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 175 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 051

HV battery module 051 voltage GV60_HVBAT_CMU051_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 052

HV battery module 052 voltage GV60_HVBAT_CMU052_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 191 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 053

HV battery module 053 voltage GV60_HVBAT_CMU053_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 192 to 199 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 054

HV battery module 054 voltage GV60_HVBAT_CMU054_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 055

HV battery module 055 voltage GV60_HVBAT_CMU055_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 215 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 056

HV battery module 056 voltage GV60_HVBAT_CMU056_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 057

HV battery module 057 voltage GV60_HVBAT_CMU057_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 058

HV battery module 058 voltage GV60_HVBAT_CMU058_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 232 to 239 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 059

HV battery module 059 voltage GV60_HVBAT_CMU059_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 240 to 247 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 060

HV battery module 060 voltage GV60_HVBAT_CMU060_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 248 to 255 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 061

HV battery module 061 voltage GV60_HVBAT_CMU061_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 256 to 263 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 062

HV battery module 062 voltage GV60_HVBAT_CMU062_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 264 to 271 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 063

HV battery module 063 voltage GV60_HVBAT_CMU063_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 272 to 279 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 064

HV battery module 064 voltage GV60_HVBAT_CMU064_VOLTConfirmed

  • Request22 01 03
  • Service 22DID 0103
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 280 to 287 of the reply, 8 bits.

0xB5 = 181 → (181 ÷ 50) = 3.62 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 065

HV battery module 065 voltage GV60_HVBAT_CMU065_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 066

HV battery module 066 voltage GV60_HVBAT_CMU066_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 40 to 47 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 067

HV battery module 067 voltage GV60_HVBAT_CMU067_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 55 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 068

HV battery module 068 voltage GV60_HVBAT_CMU068_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 63 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 069

HV battery module 069 voltage GV60_HVBAT_CMU069_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 070

HV battery module 070 voltage GV60_HVBAT_CMU070_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 071

HV battery module 071 voltage GV60_HVBAT_CMU071_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 072

HV battery module 072 voltage GV60_HVBAT_CMU072_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 95 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 073

HV battery module 073 voltage GV60_HVBAT_CMU073_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 074

HV battery module 074 voltage GV60_HVBAT_CMU074_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 111 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 075

HV battery module 075 voltage GV60_HVBAT_CMU075_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 076

HV battery module 076 voltage GV60_HVBAT_CMU076_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 127 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 077

HV battery module 077 voltage GV60_HVBAT_CMU077_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 135 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 078

HV battery module 078 voltage GV60_HVBAT_CMU078_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 143 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 079

HV battery module 079 voltage GV60_HVBAT_CMU079_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 151 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 080

HV battery module 080 voltage GV60_HVBAT_CMU080_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 159 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 081

HV battery module 081 voltage GV60_HVBAT_CMU081_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 082

HV battery module 082 voltage GV60_HVBAT_CMU082_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 175 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 083

HV battery module 083 voltage GV60_HVBAT_CMU083_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 084

HV battery module 084 voltage GV60_HVBAT_CMU084_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 191 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 085

HV battery module 085 voltage GV60_HVBAT_CMU085_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 192 to 199 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 086

HV battery module 086 voltage GV60_HVBAT_CMU086_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 087

HV battery module 087 voltage GV60_HVBAT_CMU087_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 215 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 088

HV battery module 088 voltage GV60_HVBAT_CMU088_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 089

HV battery module 089 voltage GV60_HVBAT_CMU089_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 090

HV battery module 090 voltage GV60_HVBAT_CMU090_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 232 to 239 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 091

HV battery module 091 voltage GV60_HVBAT_CMU091_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 240 to 247 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 092

HV battery module 092 voltage GV60_HVBAT_CMU092_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 248 to 255 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 093

HV battery module 093 voltage GV60_HVBAT_CMU093_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 256 to 263 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 094

HV battery module 094 voltage GV60_HVBAT_CMU094_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 264 to 271 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 095

HV battery module 095 voltage GV60_HVBAT_CMU095_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 272 to 279 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 096

HV battery module 096 voltage GV60_HVBAT_CMU096_VOLTConfirmed

  • Request22 01 04
  • Service 22DID 0104
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 280 to 287 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 097

HV battery module 097 voltage GV60_HVBAT_CMU097_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 098

HV battery module 098 voltage GV60_HVBAT_CMU098_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 40 to 47 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 099

HV battery module 099 voltage GV60_HVBAT_CMU099_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 55 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 100

HV battery module 100 voltage GV60_HVBAT_CMU100_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 63 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 101

HV battery module 101 voltage GV60_HVBAT_CMU101_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 102

HV battery module 102 voltage GV60_HVBAT_CMU102_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 103

HV battery module 103 voltage GV60_HVBAT_CMU103_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 104

HV battery module 104 voltage GV60_HVBAT_CMU104_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 95 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 105

HV battery module 105 voltage GV60_HVBAT_CMU105_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 106

HV battery module 106 voltage GV60_HVBAT_CMU106_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 111 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 107

HV battery module 107 voltage GV60_HVBAT_CMU107_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 108

HV battery module 108 voltage GV60_HVBAT_CMU108_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 127 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 109

HV battery module 109 voltage GV60_HVBAT_CMU109_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 135 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 110

HV battery module 110 voltage GV60_HVBAT_CMU110_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 143 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 111

HV battery module 111 voltage GV60_HVBAT_CMU111_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 151 of the reply, 8 bits.

0xBC = 188 → (188 ÷ 50) = 3.76 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 112

HV battery module 112 voltage GV60_HVBAT_CMU112_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 159 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 113

HV battery module 113 voltage GV60_HVBAT_CMU113_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits.

0xBC = 188 → (188 ÷ 50) = 3.76 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 114

HV battery module 114 voltage GV60_HVBAT_CMU114_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 175 of the reply, 8 bits.

0xBC = 188 → (188 ÷ 50) = 3.76 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 115

HV battery module 115 voltage GV60_HVBAT_CMU115_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 116

HV battery module 116 voltage GV60_HVBAT_CMU116_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 191 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 117

HV battery module 117 voltage GV60_HVBAT_CMU117_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 192 to 199 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 118

HV battery module 118 voltage GV60_HVBAT_CMU118_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 119

HV battery module 119 voltage GV60_HVBAT_CMU119_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 215 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 120

HV battery module 120 voltage GV60_HVBAT_CMU120_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 121

HV battery module 121 voltage GV60_HVBAT_CMU121_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 122

HV battery module 122 voltage GV60_HVBAT_CMU122_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 232 to 239 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 123

HV battery module 123 voltage GV60_HVBAT_CMU123_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 240 to 247 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 124

HV battery module 124 voltage GV60_HVBAT_CMU124_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 248 to 255 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 125

HV battery module 125 voltage GV60_HVBAT_CMU125_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 256 to 263 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 126

HV battery module 126 voltage GV60_HVBAT_CMU126_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 264 to 271 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 127

HV battery module 127 voltage GV60_HVBAT_CMU127_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 272 to 279 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 128

HV battery module 128 voltage GV60_HVBAT_CMU128_VOLTConfirmed

  • Request22 01 0A
  • Service 22DID 010A
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 280 to 287 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 129

HV battery module 129 voltage GV60_HVBAT_CMU129_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 130

HV battery module 130 voltage GV60_HVBAT_CMU130_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 40 to 47 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 131

HV battery module 131 voltage GV60_HVBAT_CMU131_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 55 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 132

HV battery module 132 voltage GV60_HVBAT_CMU132_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 63 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 133

HV battery module 133 voltage GV60_HVBAT_CMU133_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 134

HV battery module 134 voltage GV60_HVBAT_CMU134_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 135

HV battery module 135 voltage GV60_HVBAT_CMU135_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 136

HV battery module 136 voltage GV60_HVBAT_CMU136_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 95 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 137

HV battery module 137 voltage GV60_HVBAT_CMU137_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 138

HV battery module 138 voltage GV60_HVBAT_CMU138_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 111 of the reply, 8 bits.

0xBC = 188 → (188 ÷ 50) = 3.76 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 139

HV battery module 139 voltage GV60_HVBAT_CMU139_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 140

HV battery module 140 voltage GV60_HVBAT_CMU140_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 127 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 141

HV battery module 141 voltage GV60_HVBAT_CMU141_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 135 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 142

HV battery module 142 voltage GV60_HVBAT_CMU142_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 143 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 143

HV battery module 143 voltage GV60_HVBAT_CMU143_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 151 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 144

HV battery module 144 voltage GV60_HVBAT_CMU144_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 159 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 145

HV battery module 145 voltage GV60_HVBAT_CMU145_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 146

HV battery module 146 voltage GV60_HVBAT_CMU146_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 175 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 147

HV battery module 147 voltage GV60_HVBAT_CMU147_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 148

HV battery module 148 voltage GV60_HVBAT_CMU148_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 191 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 149

HV battery module 149 voltage GV60_HVBAT_CMU149_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 192 to 199 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 150

HV battery module 150 voltage GV60_HVBAT_CMU150_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 151

HV battery module 151 voltage GV60_HVBAT_CMU151_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 215 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 152

HV battery module 152 voltage GV60_HVBAT_CMU152_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 153

HV battery module 153 voltage GV60_HVBAT_CMU153_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 154

HV battery module 154 voltage GV60_HVBAT_CMU154_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 232 to 239 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 155

HV battery module 155 voltage GV60_HVBAT_CMU155_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 240 to 247 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 156

HV battery module 156 voltage GV60_HVBAT_CMU156_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 248 to 255 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 157

HV battery module 157 voltage GV60_HVBAT_CMU157_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 256 to 263 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 158

HV battery module 158 voltage GV60_HVBAT_CMU158_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 264 to 271 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 159

HV battery module 159 voltage GV60_HVBAT_CMU159_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 272 to 279 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 160

HV battery module 160 voltage GV60_HVBAT_CMU160_VOLTConfirmed

  • Request22 01 0B
  • Service 22DID 010B
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 280 to 287 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 161

HV battery module 161 voltage GV60_HVBAT_CMU161_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 32 to 39 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 162

HV battery module 162 voltage GV60_HVBAT_CMU162_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 40 to 47 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 163

HV battery module 163 voltage GV60_HVBAT_CMU163_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 48 to 55 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 164

HV battery module 164 voltage GV60_HVBAT_CMU164_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 56 to 63 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 165

HV battery module 165 voltage GV60_HVBAT_CMU165_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 64 to 71 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 166

HV battery module 166 voltage GV60_HVBAT_CMU166_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 72 to 79 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 167

HV battery module 167 voltage GV60_HVBAT_CMU167_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 80 to 87 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 168

HV battery module 168 voltage GV60_HVBAT_CMU168_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 88 to 95 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 169

HV battery module 169 voltage GV60_HVBAT_CMU169_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 96 to 103 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 170

HV battery module 170 voltage GV60_HVBAT_CMU170_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 104 to 111 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 171

HV battery module 171 voltage GV60_HVBAT_CMU171_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 112 to 119 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 172

HV battery module 172 voltage GV60_HVBAT_CMU172_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 120 to 127 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 173

HV battery module 173 voltage GV60_HVBAT_CMU173_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 128 to 135 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 174

HV battery module 174 voltage GV60_HVBAT_CMU174_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 136 to 143 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 175

HV battery module 175 voltage GV60_HVBAT_CMU175_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 144 to 151 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 176

HV battery module 176 voltage GV60_HVBAT_CMU176_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 152 to 159 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 177

HV battery module 177 voltage GV60_HVBAT_CMU177_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 160 to 167 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 178

HV battery module 178 voltage GV60_HVBAT_CMU178_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 168 to 175 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 179

HV battery module 179 voltage GV60_HVBAT_CMU179_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 176 to 183 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 180

HV battery module 180 voltage GV60_HVBAT_CMU180_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 184 to 191 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 181

HV battery module 181 voltage GV60_HVBAT_CMU181_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 192 to 199 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 182

HV battery module 182 voltage GV60_HVBAT_CMU182_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 200 to 207 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 183

HV battery module 183 voltage GV60_HVBAT_CMU183_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 208 to 215 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 184

HV battery module 184 voltage GV60_HVBAT_CMU184_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 216 to 223 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 185

HV battery module 185 voltage GV60_HVBAT_CMU185_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 224 to 231 of the reply, 8 bits.

0xBC = 188 → (188 ÷ 50) = 3.76 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 186

HV battery module 186 voltage GV60_HVBAT_CMU186_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 232 to 239 of the reply, 8 bits.

0xBC = 188 → (188 ÷ 50) = 3.76 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 187

HV battery module 187 voltage GV60_HVBAT_CMU187_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 240 to 247 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 188

HV battery module 188 voltage GV60_HVBAT_CMU188_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 248 to 255 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 189

HV battery module 189 voltage GV60_HVBAT_CMU189_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 256 to 263 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 190

HV battery module 190 voltage GV60_HVBAT_CMU190_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 264 to 271 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 191

HV battery module 191 voltage GV60_HVBAT_CMU191_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 272 to 279 of the reply, 8 bits.

0xBB = 187 → (187 ÷ 50) = 3.74 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Battery › Modules › 192

HV battery module 192 voltage GV60_HVBAT_CMU192_VOLTConfirmed

  • Request22 01 0C
  • Service 22DID 010C
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2022, 2024 to 2026

Example reply from a 2023 Genesis GV60.

Bits 280 to 287 of the reply, 8 bits.

0xBA = 186 → (186 ÷ 50) = 3.72 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2023. In testing for 2022, 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.