Battery parameters
The Jaguar E-PACE has 28 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery EPACE_12V_BATTERY
- Request
22 DD 02 - Service 22
DID DD02 - Module
753 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 2017 to 2026.
Battery capacity, maximum EPACE_BATTERY_SOH_CAPACITY_MAX
- Request
22 49 1A - Service 22
DID 491A - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Battery capacity, minimum EPACE_BATTERY_SOH_CAPACITY_MIN
- Request
22 49 19 - Service 22
DID 4919 - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
Battery coolant in EPACE_BATTERY_COOLANT_IN
- Request
22 49 1C - Service 22
DID 491C - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- -20 to 30 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery coolant out EPACE_BATTERY_COOLANT_OUT
- Request
22 49 1B - Service 22
DID 491B - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- -20 to 30
- Unit
- Number
In testing for 2017 to 2026.
Battery power EPACE_BATTERY_SOH_POWER
- Request
22 49 15 - Service 22
DID 4915 - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2017 to 2026.
Battery power, maximum EPACE_BATTERY_SOH_POWER_MAX
- Request
22 49 17 - Service 22
DID 4917 - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2017 to 2026.
Battery power, minimum EPACE_BATTERY_SOH_POWER_MIN
- Request
22 49 16 - Service 22
DID 4916 - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2017 to 2026.
Battery state of health, average EPACE_HVB_SOH
Pelican can show this parameter as the state of health.
- Request
22 49 18 - Service 22
DID 4918 - Module
7E4 → 7EC - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2020, 2022 to 2026. Not supported for 2021.
Battery temperature EPACE_HVB_T
- Request
22 49 07 - Service 22
DID 4907 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2020, 2022 to 2026. Not supported for 2021.
Battery temperature, maximum EPACE_BATTERY_T_MAX
- Request
22 49 05 - Service 22
DID 4905 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery temperature, minimum EPACE_BATTERY_T_MIN
- Request
22 49 06 - Service 22
DID 4906 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2017 to 2026.
Battery voltage EPACE_BAT_V
- Request
22 11 72 - Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 625 ÷ 10000)- Range
- 0 to 15.9375 V
- Unit
- V
In testing for 2017 to 2026.
Battery, maximum regen EPACE_BATTERY_MAX_REGEN
- Request
22 49 13 - Service 22
DID 4913 - Module
7E4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 2017 to 2026.
Cell voltage, maximum EPACE_HVB_CELL_V_MAXConfirmed
- Request
22 49 03 - Service 22
DID 4903 - Module
7E4 → 7EC - Every
5 s - Testing for 2017 to 2020, 2022 to 2026
Example reply from a 2021 Jaguar E-PACE.
Bits 0 to 15 of the reply, 16 bits.
0x0CB8 = 3256 → 3,256 mV
- Formula
val- Range
- 0 to 32767 mV
- Unit
- mV
Confirmed for 2021. In testing for 2017 to 2020, 2022 to 2026.
Cell voltage, minimum EPACE_HVB_CELL_V_MINConfirmed
- Request
22 49 04 - Service 22
DID 4904 - Module
7E4 → 7EC - Every
5 s - Testing for 2017 to 2020, 2022 to 2026
Example reply from a 2021 Jaguar E-PACE.
Bits 0 to 15 of the reply, 16 bits.
0x0CB5 = 3253 → 3,253 mV
- Formula
val- Range
- 0 to 32767 mV
- Unit
- mV
Confirmed for 2021. In testing for 2017 to 2020, 2022 to 2026.
Charge voltage EPACE_CHARGE_V
- Request
22 49 8F - Service 22
DID 498F - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 200 to 240 V
- Unit
- V
In testing for 2017 to 2026.
Charge, current EPACE_CHARGE_CUR
- Request
22 49 8F - Service 22
DID 498F - Module
7E5 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 40 A
- Unit
- A
In testing for 2017 to 2026.
Charger mode EPACE_CHARGER_MODE
- Request
22 FE 0C - Service 22
DID FE0C - Module
7E5 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2021.
Current EPACE_HVB_CURR
- Request
22 49 0C - Service 22
DID 490C - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 40)- Range
- -500 to 1000 A
- Unit
- A
In testing for 2017 to 2020, 2022 to 2026. Not supported for 2021.
DCDC HV voltage in EPACE_DCDC_HV_V_IN
- Request
22 48 37 - Service 22
DID 4837 - Module
753 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2017 to 2026.
DCDC voltage out EPACE_DCDC_V_OUT
- Request
22 42 0A - Service 22
DID 420A - Module
753 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2017 to 2026.
High voltage battery voltage EPACE_HVB_VConfirmed
- Request
22 49 0F - Service 22
DID 490F - Module
7E4 → 7EC - Every
5 s - Testing for 2017 to 2020, 2022 to 2026
Example reply from a 2021 Jaguar E-PACE.
Bits 0 to 15 of the reply, 16 bits.
0x0957 = 2391 → (2391 ÷ 100) = 23.91 V
- Formula
(val ÷ 100)- Range
- 0 to 450 V
- Unit
- V
Confirmed for 2021. In testing for 2017 to 2020, 2022 to 2026.
Max discharge EPACE_MAX_DISCHARGE
- Request
22 49 12 - Service 22
DID 4912 - Module
7E4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 80 kW
- Unit
- kW
In testing for 2017 to 2026.
State of charge EPACE_SOC
Pelican can show this parameter as the state of charge.
- Request
22 49 10 - Service 22
DID 4910 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2020, 2022 to 2026. Not supported for 2021.
State of charge, maximum EPACE_SOC_MAX
- Request
22 49 14 - Service 22
DID 4914 - Module
7E4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.
State of charge, minimum EPACE_SOC_MIN
- Request
22 49 11 - Service 22
DID 4911 - Module
7E4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2026.