Kia Stinger

Engine parameters

The Kia Stinger has 191 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Automatic transmission fluid temperature STINGER_ATF_T_7E1Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2023 Kia Stinger.

Bits 104 to 111 of the reply, 8 bits.

0x5A = 90 → (90 − 40) = 50 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

4WD clutch duty STINGER_AWD_CLU_DUTYConfirmed

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 72 to 87 of the reply, 16 bits. The value is signed.

0x0068 = 104 → (104 ÷ 10) = 10.4 %

Formula
(val ÷ 10)
Range
-3276.8 to 100 %
Unit
%

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

4WD clutch pressure STINGER_AWD_CLU_PConfirmed

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing for 2018 to 2019, 2021 to 2023

Bits 216 to 231 of the reply, 16 bits. The value is signed.

Formula
(val × 0.001953)
Range
-63.99 to 63.99 bar
Unit
bar

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

4WD clutch stress STINGER_AWD_CLU_STRESSConfirmed

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 104 to 119 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 0.001953) = 0 %

Formula
(val × 0.001953)
Range
-63.99 to 63.99 %
Unit
%

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

4WD clutch torque STINGER_AWD_CLU_TQConfirmed

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 200 to 215 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 N·m

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 N·m
Unit
N·m

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

4WD front axle ratio STINGER_AWD_FRONT_AXLE_RATConfirmed

  • Request22 01 A3
  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing for 2018 to 2019, 2021 to 2023

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
(val × 2 ÷ 65535)
Range
-1 to 0.999
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2018, 2020. Supported for 2022 to 2023.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2020.

Air conditioning pressure STINGER_AC_PConfirmed

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 112 to 119 of the reply, 8 bits.

0x40 = 64 → (64 × 3520 ÷ 255) = 883.45098 kPa

Formula
(val × 3520 ÷ 255)
Range
0 to 3520 kPa
Unit
kPa

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Air conditioning relay STINGER_AC_RELAY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Automatic transmission fluid temperature STINGER_ATF_T_7E1Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2023 Kia Stinger.

Bits 104 to 111 of the reply, 8 bits.

0x5A = 90 → (90 − 40) = 50 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Barometric pressure STINGER_BAROMETRIC_PRESSURE

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2020 to 2023. Supported for 2019.

Catalyst damaging misfires total all cylinders STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Catalyst damaging misfires total, cylinder 1 STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Catalyst damaging misfires total, cylinder 1 STINGER_CATDMG_MIS_TOT_1Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Catalyst damaging misfires total, cylinder 2 STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Catalyst damaging misfires total, cylinder 2 STINGER_CATDMG_MIS_TOT_2Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Catalyst damaging misfires total, cylinder 3 STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Catalyst damaging misfires total, cylinder 3 STINGER_CATDMG_MIS_TOT_3Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Catalyst damaging misfires total, cylinder 4 STINGER_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Catalyst damaging misfires total, cylinder 4 STINGER_CATDMG_MIS_TOT_4Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed

  • Request01 3E
  • Service 01PID 3E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed

  • Request01 3D
  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020. Supported for 2019, 2021 to 2022.

Catalyst temperature bank 2, sensor 2 CATEMP22SAE J1979Confirmed

  • Request01 3F
  • Service 01PID 3F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020. Supported for 2019, 2021 to 2022.

Clutch solenoid duty STINGER_CLUTCH_SOLENOID_DUTY

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2018 to 2023.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Commanded evaporative purge STINGER_COMMANDED_EVAPORATIVE_PURGE

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Commanded throttle actuator STINGER_COMMANDED_THROTTLE_ACTUATOR

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2018, 2020.

Commanded torque STINGER_COMMANDED_TORQUE

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 N·m
Unit
N·m

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Coolant STINGER_COOLANT_FAN

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Coolant fan PWM STINGER_CLT_FAN_PWMConfirmed

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 88 to 95 of the reply, 8 bits.

0x45 = 69 → (69 × 100 ÷ 255) = 27.058824 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Diesel particulate filter differential pressure STINGER_DPF_DIFF_PConfirmed

  • Request22 E0 F1
  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 248 to 255 of the reply, 8 bits.

0x00 = 0 → (0 × 431.373 ÷ 100 − 100) = -100

Formula
(val × 431.373 ÷ 100 − 100)
Range
-100 to 1000
Unit
Raw value

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Diesel particulate filter differential pressure STINGER_DPF_DIFFERENTIAL_PRESSURE

  • Request21 1B
  • Service 21PID 1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5
Unit
Raw value

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Diesel particulate filter regeneration count STINGER_DPF_REGEN_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Diesel particulate filter regeneration state STINGER_DPF_REGEN_ST

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bit 431 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Diesel particulate filter regeneration state STINGER_DPF_REGENERATION_STATE

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Diesel particulate filter soot mass STINGER_DPF_SOOT_MASS

  • Request22 ED 94
  • Service 22DID ED94
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 99 ÷ 255)
Range
0 to 99
Unit
Raw value

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Diesel particulate filter total sulfur mass STINGER_DPF_TOT_SULFUR_MASS

  • Request22 ED 29
  • Service 22DID ED29
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.15259)
Range
0 to 9999
Unit
Raw value

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Direct injection time 1st pulse, cylinder 1 STINGER_DI_TIME_1ST_CYL_1Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

0x0110 = 272 → (272 × 4 ÷ 1000) = 1.088 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 1st pulse, cylinder 2 STINGER_DI_TIME_1ST_CYL_2Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

0x0109 = 265 → (265 × 4 ÷ 1000) = 1.06 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 1st pulse, cylinder 3 STINGER_DI_TIME_1ST_CYL_3Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

0x0111 = 273 → (273 × 4 ÷ 1000) = 1.092 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 1st pulse, cylinder 4 STINGER_DI_TIME_1ST_CYL_4Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

0x0112 = 274 → (274 × 4 ÷ 1000) = 1.096 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 1st pulse, cylinder 5 STINGER_CYL5_INJ_TIME_1STConfirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.

0x010F = 271 → (271 × 4 ÷ 1000) = 1.084 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 1st pulse, cylinder 6 STINGER_CYL6_INJ_TIME_1STConfirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.

0x011C = 284 → (284 × 4 ÷ 1000) = 1.136 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 2nd pulse, cylinder 1 STINGER_DI_TIME_2ND_CYL_1Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 2nd pulse, cylinder 2 STINGER_DI_TIME_2ND_CYL_2Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 2nd pulse, cylinder 3 STINGER_DI_TIME_2ND_CYL_3Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 2nd pulse, cylinder 4 STINGER_DI_TIME_2ND_CYL_4Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 2nd pulse, cylinder 5 STINGER_CYL5_INJ_TIME_2NDConfirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Direct injection time 2nd pulse, cylinder 6 STINGER_CYL6_INJ_TIME_2NDConfirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 × 4 ÷ 1000) = 0 ms

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Emission relevant misfires total all cylinders STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Emission relevant misfires total, cylinder 1 STINGER_EMIS_MIS_TOT_1Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Emission relevant misfires total, cylinder 1 STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Emission relevant misfires total, cylinder 2 STINGER_EMIS_MIS_TOT_2Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Emission relevant misfires total, cylinder 2 STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Emission relevant misfires total, cylinder 3 STINGER_EMIS_MIS_TOT_3Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Emission relevant misfires total, cylinder 3 STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Emission relevant misfires total, cylinder 4 STINGER_EMIS_MIS_TOT_4Confirmed

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Emission relevant misfires total, cylinder 4 STINGER_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018 to 2022. Supported for 2023.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Request01 8E
  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2020.

Engine oil temperature STINGER_EOTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s

Example reply from a 2023 Kia Stinger.

Bits 272 to 279 of the reply, 8 bits.

0x81 = 129 → (129 ÷ 1.3333 − 48) = 48.752419 °C

Formula
(val ÷ 1.3333 − 48)
Range
0 to 143 °C
Unit
°C

Confirmed for 2018 to 2023.

Engine oil temperature STINGER_EOT_7E0

  • Request22 ED 07
  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 0.7843 − 50)
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Engine oil temperature STINGER_EOT_V2Confirmed

  • Request22 ED 02
  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 184 to 191 of the reply, 8 bits.

0x62 = 98 → (98 − 4) = 94 °C

Formula
(val − 4)
Range
-4 to 251 °C
Unit
°C

Confirmed for 2020. Not supported for 2018 to 2019, 2021 to 2023.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Request01 63
  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2020.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Engine RPM STINGER_RPM

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Engine, actual torque STINGER_ENG_ACT_TQ

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 2.3529)
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 32
  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4000)
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2018, 2020. Supported for 2019, 2022 to 2023.

Exhaust gas temperature STINGER_EXHAUST_GAS_T

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
(val × 4.709803922 + 99)
Range
99 to 1300 °C
Unit
°C

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Exhaust temperature 1, upstream of oxidation catalyst STINGER_EXH_T_1_UP_OXICAT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
(val × 4.7098 + 99)
Range
0 to 1299.999 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Exhaust temperature 2, upstream of DPF STINGER_EXH_T_2_UP_DPF

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
(val × 4.7098 + 99)
Range
0 to 1299.999 °C
Unit
°C

In testing for 2018 to 2019, 2021 to 2023. Not supported for 2020.

Front left tire temperature STINGER_FL_TT

Pelican can show this parameter as the front left tire temperature.

  • Request21 06
  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Front right tire temperature STINGER_FR_TT

Pelican can show this parameter as the front right tire temperature.

  • Request21 06
  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 59
  • Service 01PID 59
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2018, 2020.

Gasoline direct injection time bank a, 1 STINGER_GDI_IT_A1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2018 to 2019, 2021, 2023

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.

Gasoline direct injection time bank a, 2 STINGER_GDI_IT_A2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2018 to 2019, 2021, 2023

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.

Gasoline direct injection time bank a, 3 STINGER_GDI_IT_A3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2018 to 2019, 2021, 2023

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.

Gasoline direct injection time bank a, 4 STINGER_GDI_IT_A4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2018 to 2019, 2021, 2023

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.

Gasoline direct injection time bank b, 1 STINGER_GDI_IT_B1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2018 to 2019, 2021, 2023

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.

Gasoline direct injection time bank b, 2 STINGER_GDI_IT_B2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2018 to 2019, 2021, 2023

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.

Gasoline direct injection time bank b, 3 STINGER_GDI_IT_B3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2018 to 2019, 2021, 2023

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.

Gasoline direct injection time bank b, 4 STINGER_GDI_IT_B4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2018 to 2019, 2021, 2023

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2018 to 2019, 2021, 2023. Supported for 2020, 2022.

Heat STINGER_HEAT

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Injection duration cylinder 1 STINGER_INJ_DUR_1Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

Confirmed for 2018 to 2023.

Injection duration cylinder 2 STINGER_INJ_DUR_2Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

Confirmed for 2018 to 2023.

Injection duration cylinder 3 STINGER_INJ_DUR_3Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

Confirmed for 2018 to 2023.

Injection duration cylinder 4 STINGER_INJ_DUR_4Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

Confirmed for 2018 to 2023.

Injection duration cylinder 5 STINGER_INJ_DUR_5Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s

Example reply from a 2023 Kia Stinger.

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 1220.7) = 0 s

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

Confirmed for 2018 to 2023.

Injection duration cylinder 6 STINGER_INJ_DUR_6Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s

Example reply from a 2023 Kia Stinger.

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 ÷ 1220.7) = 0 s

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

Confirmed for 2018 to 2023.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Intake air temperature STINGER_IATConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s

Example reply from a 2023 Kia Stinger.

Bits 264 to 271 of the reply, 8 bits.

0x53 = 83 → (83 ÷ 1.3333 − 48) = 14.251556 °C

Formula
(val ÷ 1.3333 − 48)
Range
0 to 143 °C
Unit
°C

Confirmed for 2018 to 2023.

Intake camshaft position actual STINGER_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Intake camshaft position commanded STINGER_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 2)
Range
-64 to 63.5 °
Unit
°

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Knock learn cylinder 1 STINGER_KNOCK_LEARN_1Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s

Example reply from a 2022 Kia Stinger.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2019 to 2022. Supported for 2018, 2023.

Knock learn cylinder 2 STINGER_KNOCK_LEARN_2

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Supported for 2018 to 2023.

Knock learn cylinder 3 STINGER_KNOCK_LEARN_3

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Supported for 2018 to 2023.

Knock learn cylinder 4 STINGER_KNOCK_LEARN_4

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Supported for 2018 to 2023.

Knock retard cylinder #1 STINGER_KNOCK_RETARD_CYLINDER_1

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Knock retard cylinder #2 STINGER_KNOCK_RETARD_CYLINDER_2

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Knock retard cylinder #3 STINGER_KNOCK_RETARD_CYLINDER_3

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Knock retard cylinder #4 STINGER_KNOCK_RETARD_CYLINDER_4

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Knock retard cylinder 1 STINGER_KNOCK_RETARD_1Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s

Example reply from a 2023 Kia Stinger.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

0xB2 = -78 → (-78 ÷ 5) = -15.6 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2018 to 2023.

Knock retard cylinder 1, alternate STINGER_KNOCK_RETARD_1_E019Confirmed

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2023 Kia Stinger.

Bits 168 to 175 of the reply, 8 bits.

0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.

Knock retard cylinder 2 STINGER_KNOCK_RETARD_2Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s

Example reply from a 2023 Kia Stinger.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2018 to 2023.

Knock retard cylinder 2, alternate STINGER_KNOCK_RETARD_2_E019Confirmed

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2023 Kia Stinger.

Bits 176 to 183 of the reply, 8 bits.

0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.

Knock retard cylinder 3 STINGER_KNOCK_RETARD_3Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s

Example reply from a 2023 Kia Stinger.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2018 to 2023.

Knock retard cylinder 3, alternate STINGER_KNOCK_RETARD_3_E019Confirmed

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2023 Kia Stinger.

Bits 184 to 191 of the reply, 8 bits.

0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.

Knock retard cylinder 4 STINGER_KNOCK_RETARD_4Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s

Example reply from a 2023 Kia Stinger.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

0xDF = -33 → (-33 ÷ 5) = -6.6 °

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

Confirmed for 2018 to 2023.

Knock retard cylinder 4, alternate STINGER_KNOCK_RETARD_4_E019Confirmed

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018, 2021

Example reply from a 2023 Kia Stinger.

Bits 192 to 199 of the reply, 8 bits.

0x00 = 0 → (0 × 0.75 − 191.25) = -191.25 °

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.

Lock switch STINGER_LOCK_SWITCH

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bit 151 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed

  • Request01 09
  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020. Supported for 2019, 2021 to 2022.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Request01 56
  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2018, 2020.

Long term secondary O2 sensor fuel trim (bank 2) LGSO2FT2SAE J1979Confirmed

  • Request01 58
  • Service 01PID 58
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2020.

Main injection volume STINGER_MAIN_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.392156863)
Range
0 to 100 L
Unit
L

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Malfunction indicator STINGER_MALFUNCTION_INDICATOR

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Mass air flow rate STINGER_MAF_RATEConfirmed

  • Request22 E0 10
  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2018 to 2019, 2021 to 2023

Example reply from a 2020 Kia Stinger.

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

0x3E = 62 → (62 × 0.04239) = 2.62818

Formula
(val × 0.04239)
Range
0 to 10.8
Unit
Raw value

Confirmed for 2020. In testing for 2018 to 2019, 2021 to 2023.

Misfire count #1 STINGER_MIS_1

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019. Not supported for 2018, 2020 to 2023.

Misfire count #2 STINGER_MIS_2

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019. Not supported for 2018, 2020 to 2023.

Misfire count #3 STINGER_MIS_3

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019. Not supported for 2018, 2020 to 2023.

Misfire count #4 STINGER_MIS_4

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019. Not supported for 2018, 2020 to 2023.

Misfires, current, cylinder 1 STINGER_MISFIRES_C1_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Misfires, current, cylinder 2 STINGER_MISFIRES_C2_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Misfires, current, cylinder 3 STINGER_MISFIRES_C3_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Misfires, current, cylinder 4 STINGER_MISFIRES_C4_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018 to 2019, 2021, 2023. Not supported for 2020, 2022.

Motor-driven power steering current STINGER_MDPS_MOTOR_CURRENTConfirmed

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing for 2019

Example reply from a 2023 Kia Stinger.

Bits 88 to 95 of the reply, 8 bits. The value is signed.

0x00 = 0 → 0 A

Formula
val
Range
-128 to 127 A
Unit
A

Confirmed for 2018, 2020 to 2023. Not supported for 2019.

Oxygen sensor 1 bank 1 STINGER_OXYGEN_SENSOR_11

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Oxygen sensor 2 bank 1 STINGER_OXYGEN_SENSOR_21

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Pilot injection volume STINGER_PILOT_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Post injection volume STINGER_POST_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Pressure sensor STINGER_PRESSURE_SENSOR

  • Request21 C0
  • Service 21PID C0
  • Module7E5
  • Every250 ms
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 bar
Unit
bar

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Rear left tire temperature STINGER_RL_TT

Pelican can show this parameter as the rear left tire temperature.

  • Request21 06
  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Rear right tire temperature STINGER_RR_TT

Pelican can show this parameter as the rear right tire temperature.

  • Request21 06
  • Service 21PID 06
  • Module7D6 → 7DE
  • Every15 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Requested torque STINGER_REQUESTED_TORQUE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 0.001526)
Range
0 to 100 %
Unit
%

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018, 2020, 2023. Supported for 2019, 2021 to 2022.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 08
  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020. Supported for 2019, 2021 to 2022.

Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed

  • Request01 55
  • Service 01PID 55
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2018, 2020.

Short term secondary O2 sensor fuel trim (bank 2) STSO2FT2SAE J1979Confirmed

  • Request01 57
  • Service 01PID 57
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2020.

Throttle position #1 STINGER_THROTTLE_POSITION__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Throttle position #2 STINGER_THROTTLE_POSITION__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2018, 2020. Supported for 2019, 2021 to 2023.

Timing advance #1 STINGER_TIMING_ADVANCE_1

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Timing advance #2 STINGER_TIMING_ADVANCE_2

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Timing advance #3 STINGER_TIMING_ADVANCE_3

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Timing advance #4 STINGER_TIMING_ADVANCE_4

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2018 to 2019, 2021. Not supported for 2020, 2022 to 2023.

Torque converter slip STINGER_TORQUE_CONVERTER_SLIPConfirmed

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2018, 2021

Example reply from a 2023 Kia Stinger.

Bits 128 to 143 of the reply, 16 bits.

0x0800 = 2048 → (2048 ÷ 4 − 512) = 0 rpm

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

Confirmed for 2019 to 2020, 2022 to 2023. In testing for 2018, 2021.

Turbo boost gauge pressure STINGER_TURBO_BOOSTConfirmed

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms

Example reply from a 2023 Kia Stinger.

Bits 56 to 71 of the reply, 16 bits.

0x2C02 = 11266 → (11266 ÷ 831.556909 − 12) = 1.548081 psi

Formula
(val ÷ 831.556909 − 12)
Range
-10 to 66.81 psi
Unit
psi

Confirmed for 2018 to 2023.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2018, 2020.

Variable valve timing temperature STINGER_CVVT_T

Continuously variable valve timing temperature.

  • Request21 18
  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val − 48)
Range
-48 to 207 °C
Unit
°C

In testing for 2019, 2021. Not supported for 2018, 2020, 2022 to 2023.

Waste gate duty STINGER_WG_DUTYConfirmed

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms

Example reply from a 2023 Kia Stinger.

Bits 408 to 423 of the reply, 16 bits.

0x1E70 = 7792 → (7792 × 200 ÷ 65535) = 23.77966 %

Formula
(val × 200 ÷ 65535)
Range
0 to 200 %
Unit
%

Confirmed for 2018 to 2023.

Waste gate position STINGER_WG_POSITIONConfirmed

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms

Example reply from a 2023 Kia Stinger.

Bits 424 to 439 of the reply, 16 bits.

0x0369 = 873 → (873 × 400 ÷ 65535) = 5.32845 %

Formula
(val × 400 ÷ 65535)
Range
0 to 400 %
Unit
%

Confirmed for 2018 to 2023.

Waste gate set point STINGER_WG_SETPOINTConfirmed

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms

Example reply from a 2023 Kia Stinger.

Bits 440 to 455 of the reply, 16 bits.

0x3C60 = 15456 → (15456 × 400 ÷ 65535) = 94.337377 %

Formula
(val × 400 ÷ 65535)
Range
0 to 100 %
Unit
%

Confirmed for 2018 to 2023.

Waste gate voltage STINGER_WG_VOLTAGEConfirmed

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms

Bits 392 to 407 of the reply, 16 bits.

Formula
(val × 10 ÷ 65535)
Range
0 to 10 V
Unit
V

Confirmed for 2018 to 2023.

Engine › Misfires

Emission-relevant misfires, cylinder #1 STINGER_MIS_CNT_EMIS_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Emission-relevant misfires, cylinder #2 STINGER_MIS_CNT_EMIS_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Emission-relevant misfires, cylinder #3 STINGER_MIS_CNT_EMIS_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Emission-relevant misfires, cylinder #4 STINGER_MIS_CNT_EMIS_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires harmful for catalyst cylinder 1 STINGER_MIS_CAT_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires harmful for catalyst cylinder 2 STINGER_MIS_CAT_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires harmful for catalyst cylinder 3 STINGER_MIS_CAT_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires harmful for catalyst cylinder 4 STINGER_MIS_CAT_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires total counter, all cylinders STINGER_MIS_CNT_ALL

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires total counter, cylinder #1 STINGER_MIS_CNT_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires total counter, cylinder #2 STINGER_MIS_CNT_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires total counter, cylinder #3 STINGER_MIS_CNT_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires total counter, cylinder #4 STINGER_MIS_CNT_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires, cylinder 1 STINGER_MIS_1_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires, cylinder 2 STINGER_MIS_2_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires, cylinder 3 STINGER_MIS_3_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Misfires, cylinder 4 STINGER_MIS_4_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2018, 2021. Not supported for 2019 to 2020, 2022 to 2023.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2019 to 2023.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Request01 15
  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

O2S Output Voltage Bank 2, Sensor 2 O2S22SAE J1979Confirmed

  • Request01 19
  • Service 01PID 19
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2020. Supported for 2019, 2021 to 2022.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2023.

SHRTFT associated with O2S22 SHRTFT22SAE J1979Confirmed

  • Request01 19
  • Service 01PID 19
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2020. Supported for 2019, 2021 to 2022.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2019 to 2023.

Engine › Unknown

Unknown STINGER_22E004Confirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

Confirmed for 2018 to 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.