Air fuel sensor voltage, bank 1 sensor 1 LEXUS_AFS_VOLTAGE_B1S1Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 32 to 47 of the reply, 16 bits.

0x9FFF = 40959 → (40959 × 7.99 ÷ 65535) = 4.993704 V

Formula
(val × 7.99 ÷ 65535)
Range
0 to 7.99 V
Unit
V

Confirmed for 2013. In testing for 2012, 2014 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

+BM voltage LEXUS_BM_V

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2012 to 2026.

1st turbocharger outlet pressure, control valve LEXUS_1ST_TRUBOCHARGER_P

  • Request22 11 CD
  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2026.

2nd turbocharger outlet pressure LEXUS_2ND_TRUBOCHARGER_OUTLET_P

  • Request22 11 AF
  • Service 22DID 11AF
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2026.

2nd turbocharger outlet pressure, control valve LEXUS_2ND_TRUBOCHARGER_P

  • Request22 11 CD
  • Service 22DID 11CD
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 300 kPa
Unit
kPa

In testing for 2012 to 2026.

12V battery current LEXUS_12V_C

  • Request22 15 F7
  • Service 22DID 15F7
  • Module7D2 → 7DA
  • Every500 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 38.147 ÷ 10000 − 125)
Range
-125 to 124 A
Unit
A

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

12V battery temperature LEXUS_12V_T

  • Request22 15 F8
  • Service 22DID 15F8
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

12V battery voltage LEXUS_12V_V_V2

Pelican can show this parameter as the starter battery voltage.

  • Request22 15 EE
  • Service 22DID 15EE
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.31448 + 0.0125)
Range
0 to 80.2 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

12V battery voltage before system main relay LEXUS_12V_BAT_V_BEFORE_SMR

  • Request22 10 7E
  • Service 22DID 107E
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 61 ÷ 50000 + 11.25)
Range
0 to 11.56 V
Unit
V

In testing for 2012 to 2026.

12V battery voltage smoothed LEXUS_12V_BAT_V_SMOOTHED

  • Request22 1F 42
  • Service 22DID 1F42
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 V
Unit
V

In testing for 2012 to 2026.

AC charging operation status LEXUS_AC_OP

  • Request22 16 84
  • Service 22DID 1684
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0STOPStopped
1STARTUPStarting up
2RUNNINGRunning
3FINISHINGFinishing

In testing for 2012 to 2026.

AC current limit LEXUS_AC_A_LIMIT

  • Request22 16 19
  • Service 22DID 1619
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 A
Unit
A

In testing for 2012 to 2026.

AC target power LEXUS_AC_P_TGT

  • Request22 16 19
  • Service 22DID 1619
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 kW
Unit
kW

In testing for 2012 to 2026.

AC usable power LEXUS_AC_P_USABLE

  • Request22 16 65
  • Service 22DID 1665
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55 kW
Unit
kW

In testing for 2012 to 2026.

Accumulated time of battery low LEXUS_ACCUMULATED_TIME_BAT

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2026.

Accumulated time of battery too high LEXUS_ACCUMULATED_TIME_BAT_TOO

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2012 to 2026.

Air fuel sensor voltage, bank 1 sensor 1 LEXUS_AFS_VOLTAGE_B1S1Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 32 to 47 of the reply, 16 bits.

0x9FFF = 40959 → (40959 × 7.99 ÷ 65535) = 4.993704 V

Formula
(val × 7.99 ÷ 65535)
Range
0 to 7.99 V
Unit
V

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Aux battery voltage LEXUS_AUX_BAT_V

  • Request22 10 02
  • Service 22DID 1002
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 61 ÷ 50000)
Range
0 to 79.95 V
Unit
V

In testing for 2012 to 2026.

Aux. battery capacity after IG OFF LEXUS_AUX_BAT_CAP_AFTER_IG_OFF

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 Ah
Unit
Ah

In testing for 2012 to 2026.

Aux. battery capacity after IG ON LEXUS_AUX_BAT_CAP_AFTER_IG_ON

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 Ah
Unit
Ah

In testing for 2012 to 2026.

Auxiliary battery current LEXUS_AUXILIARY_BAT

  • Request22 18 02
  • Service 22DID 1802
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2525 ÷ 13107 − 12500)
Range
-12500 to -12451 A
Unit
A

In testing for 2012 to 2026.

Auxiliary battery temperature LEXUS_AUXILIARY_BAT_T

  • Request21 41
  • Service 21PID 41
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215
Unit
Number

In testing for 2012 to 2026.

Auxiliary battery voltage LEXUS_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 5 − 25.6)
Range
-25.6 to 25.4 V
Unit
V

In testing for 2012 to 2026.

Auxiliary battery voltage LEXUS_AUXILIARY_BAT_V

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 47 ÷ 38550 − 40)
Range
-40 to 39.9 V
Unit
V

In testing for 2012 to 2026.

Battery block 1 voltage LEXUS_BAT_BLOCK_V_V01

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 2 voltage LEXUS_BAT_BLOCK_V_V02

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 3 voltage LEXUS_BAT_BLOCK_V_V03

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 4 voltage LEXUS_BAT_BLOCK_V_V04

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 5 voltage LEXUS_BAT_BLOCK_V_V05

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 6 voltage LEXUS_BAT_BLOCK_V_V06

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 7 voltage LEXUS_BAT_BLOCK_V_V07

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 8 voltage LEXUS_BAT_BLOCK_V_V08

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 9 voltage LEXUS_BAT_BLOCK_V_V09

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 10 voltage, raw count LEXUS_BAT_BLOCK_V_V10_RAW

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 7999 ÷ 6553500)
Range
0 to 79.99
Unit
Number

In testing for 2012 to 2026.

Battery block 11 voltage LEXUS_BAT_BLOCK_V_V11

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 12 voltage LEXUS_BAT_BLOCK_V_V12

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 13 voltage LEXUS_BAT_BLOCK_V_V13

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 14 voltage LEXUS_BAT_BLOCK_V_V14

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block 16 voltage LEXUS_BAT_BLOCK_V_V16

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2012 to 2026.

Battery block 17 voltage LEXUS_BAT_BLOCK_V_V17

  • Request21 81
  • Service 21PID 81
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val × 7999 ÷ 6553500)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V01 LEXUS_BATTERY_BLOCK_VOL_V01

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V02 LEXUS_BATTERY_BLOCK_VOL_V02

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V03 LEXUS_BATTERY_BLOCK_VOL_V03

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V04 LEXUS_BATTERY_BLOCK_VOL_V04

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V05 LEXUS_BATTERY_BLOCK_VOL_V05

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V06 LEXUS_BATTERY_BLOCK_VOL_V06

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V07 LEXUS_BATTERY_BLOCK_VOL_V07

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V08 LEXUS_BATTERY_BLOCK_VOL_V08

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V09 LEXUS_BATTERY_BLOCK_VOL_V09

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V10 LEXUS_BATTERY_BLOCK_VOL_V10

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V11 LEXUS_BATTERY_BLOCK_VOL_V11

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V12 LEXUS_BATTERY_BLOCK_VOL_V12

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V13 LEXUS_BATTERY_BLOCK_VOL_V13

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V14 LEXUS_BATTERY_BLOCK_VOL_V14

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block vol -V15 LEXUS_BATTERY_BLOCK_VOL_V15

  • Request21 CE
  • Service 21PID CE
  • Module7E2
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

Battery block with the maximum voltage LEXUS_BAT_BLOCK_NUMBER_MAX_V

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val + 1)
Range
0 to 256
Unit
Number

In testing for 2012 to 2026.

Battery block with the minimum voltage LEXUS_BAT_BLOCK_NUMBER_MIN_V

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val + 1)
Range
0 to 256
Unit
Number

In testing for 2012 to 2026.

Battery block, maximum voltage LEXUS_BAT_BLOCK_MAX_V

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery block, minimum voltage LEXUS_BAT_BLOCK_MIN_V

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0012205692)
Range
0 to 79.99 V
Unit
V

In testing for 2012 to 2026.

Battery charging power LEXUS_CHG_P

  • Request22 10 D4
  • Service 22DID 10D4
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 kW
Unit
kW

In testing for 2012 to 2026.

Battery current LEXUS_BAT_CURRENT

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 50 ÷ 13107 − 125)
Range
-125 to 124.9 A
Unit
A

In testing for 2012 to 2026.

Battery current LEXUS_BAT_CURRENT_700

  • Request22 15 F7
  • Service 22DID 15F7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 49 ÷ 12850 − 125)
Range
-125 to 124.9 A
Unit
A

In testing for 2012 to 2026.

Battery heater temperature LEXUS_BAT_HEATER_T

  • Request22 18 24
  • Service 22DID 1824
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery status of full charge LEXUS_BAT_STAT_FULL_CHG

  • Request22 15 E5
  • Service 22DID 15E5
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 255 ÷ 2)
Range
0 to 32512.5 Ah
Unit
Ah

In testing for 2012 to 2026.

Battery temperature LEXUS_BAT_T

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature LEXUS_BAT_T_700

  • Request22 15 F8
  • Service 22DID 15F8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature LEXUS_BAT_T_700_2

  • Request22 1F F8
  • Service 22DID 1FF8
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

In testing for 2012 to 2026.

Battery temperature 01 LEXUS_BAT_T_01

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 02 LEXUS_BAT_T_02

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 03 LEXUS_BAT_T_03

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 04 LEXUS_BAT_T_04

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 05 LEXUS_BAT_T_05

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 06 LEXUS_BAT_T_06

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 07 LEXUS_BAT_T_07

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 08 LEXUS_BAT_T_08

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 09 LEXUS_BAT_T_09

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 10 LEXUS_BAT_T_10

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 11 LEXUS_BAT_T_11

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 12 LEXUS_BAT_T_12

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 13 LEXUS_BAT_T_13

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 14 LEXUS_BAT_T_14

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 15 LEXUS_BAT_T_15

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery temperature 16 LEXUS_BAT_T_16

  • Request22 18 14
  • Service 22DID 1814
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val × 19531 ÷ 5000000 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Battery voltage LEXUS_12V_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 02
  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12.207 ÷ 10000)
Range
0 to 15 V
Unit
V

In testing for 2012, 2014 to 2026. Not supported for 2013.

Battery voltage LEXUS_12V_V_700

Pelican can show this parameter as the starter battery voltage.

  • Request22 10 02
  • Service 22DID 1002
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12.207 ÷ 10000)
Range
0 to 79 V
Unit
V

In testing for 2012 to 2026.

Battery voltage LEXUS_BAT_VConfirmed

  • Request21 13
  • Service 21PID 13
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 0 to 7 of the reply, 8 bits.

0x77 = 119 → (119 ÷ 10) = 11.9 V

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Battery voltage LEXUS_BATTERY_VOLTAGE_7E0

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2012 to 2026.

Battery voltage LEXUS_BATTERY_VOLTAGE_7E0_V2

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2012 to 2026.

Battery voltage LEXUS_BATTERY_VOLTAGE_V2

Pelican can show this parameter as the starter battery voltage.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

Boost converter carrier frequency LEXUS_CONV_CARRIER

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 71 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2026.

Boost converter gate LEXUS_CONV_GATE

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 66 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2026.

Boost converter input voltage LEXUS_VL

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 2012 to 2026.

Boost converter output voltage LEXUS_VH

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 2012 to 2026.

Boost converter pressure ratio LEXUS_BOOST_RATIO

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.392)
Range
0 to 99.96 %
Unit
%

In testing for 2012 to 2026.

Boost converter temperature LEXUS_CONV_T

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

Boost converter voltage after boosting LEXUS_VH_V_AFTER_BOOSTING_7E2

  • Request21 74
  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

In testing for 2012 to 2026.

Boost converter voltage before boosting LEXUS_VL_V_BEFORE_BOOSTING_7E2

  • Request21 74
  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

In testing for 2012 to 2026.

Charge contactor current LEXUS_SCC_SOLENOID_CURRENTConfirmed

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 24 to 31 of the reply, 8 bits.

0x33 = 51 → 51 mA

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Charge stop request code LEXUS_CHG_STOP_REQ

  • Request22 16 67
  • Service 22DID 1667
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

Charger input power LEXUS_CHG_IN_P

  • Request22 16 1D
  • Service 22DID 161D
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kW
Unit
kW

In testing for 2012 to 2026.

Charger operation status LEXUS_CHGR_OP

  • Request22 16 19
  • Service 22DID 1619
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1READYReady
2STOPStopped
3ROB_STOPStopped by request

In testing for 2012 to 2026.

Charger output power LEXUS_CHGR_OUT_P

  • Request22 16 1E
  • Service 22DID 161E
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kW
Unit
kW

In testing for 2012 to 2026.

Charger output power, target LEXUS_CHGR_OUT_P_TGT

  • Request22 16 1E
  • Service 22DID 161E
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kW
Unit
kW

In testing for 2012 to 2026.

Charger supply voltage type LEXUS_CHG_V_TYPE

  • Request22 16 1C
  • Service 22DID 161C
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1V100100V series
2V200200V series

In testing for 2012 to 2026.

Charging integrated current of aux. battery LEXUS_CHG_INTEGRATED

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2012 to 2026.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2019. Supported for 2013, 2021 to 2022.

Control system mode LEXUS_CTRL_MODE

  • Request22 10 D1
  • Service 22DID 10D1
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NONENone
1DRIVINGDriving
3CHARGINGCharging

In testing for 2012 to 2026.

Converter input voltage too high LEXUS_OVERVOLTAGE_INPUT

  • Request21 74
  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bit 33 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2026.

Dark current of battery LEXUS_DARK_CURRENT_BAT

  • Request22 15 E7
  • Service 22DID 15E7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 2012 to 2026.

DC charger maximum current LEXUS_DC_STA_A_MAX

  • Request22 16 79
  • Service 22DID 1679
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2012 to 2026.

DC charger maximum power LEXUS_DC_STA_P_MAX

  • Request22 16 6A
  • Service 22DID 166A
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 kW
Unit
kW

In testing for 2012 to 2026.

DC charger maximum voltage LEXUS_DC_STA_V_MAX

  • Request22 16 81
  • Service 22DID 1681
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

DC charger present current LEXUS_DC_STA_A

  • Request22 16 6C
  • Service 22DID 166C
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2012 to 2026.

DC charger present voltage LEXUS_DC_STA_V

  • Request22 16 6B
  • Service 22DID 166B
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2012 to 2026.

DC high level communication state LEXUS_HLC

  • Request22 16 66
  • Service 22DID 1666
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

DC-DC converter high side voltage LEXUS_DC_DC_CONV_HIGH_SIDE_V

  • Request22 11 1E
  • Service 22DID 111E
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1220703 ÷ 10000000)
Range
0 to 7999 V
Unit
V

In testing for 2012 to 2026.

DC-DC converter low side voltage LEXUS_DC_DC_CONV_LOW_SIDE_V

  • Request22 11 1D
  • Service 22DID 111D
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1953 ÷ 25000)
Range
0 to 19.92 V
Unit
V

In testing for 2012 to 2026.

DC-DC converter, target voltage before charging LEXUS_DC_DC_CONV_TGT_V

  • Request22 11 1F
  • Service 22DID 111F
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1220703 ÷ 10000000)
Range
0 to 7999 V
Unit
V

In testing for 2012 to 2026.

Delta SOC LEXUS_DELTA_SOC

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2012 to 2026.

Discharging integrated current of aux. battery LEXUS_DISCHARGING

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every30 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729.5 Ah
Unit
Ah

In testing for 2012 to 2026.

Distance since last battery cable disconnection LEXUS_DIST_SINCE_BAT_DISC

  • Request22 10 6C
  • Service 22DID 106C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2012, 2014 to 2026. Not supported for 2013.

Engine control module control mode, driving control mode=1,current sensor offset mode=2,external charge control mode=3,power supply end mode=4 LEXUS_ENG_CTRL_MODULE_CTRL_1_2_3_4

  • Request21 9B
  • Service 21PID 9B
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

Full charge capacity 1 LEXUS_CAP_1

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2012 to 2026.

Full charge capacity 2 LEXUS_CAP_2

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2012 to 2026.

Full charge capacity 3 LEXUS_CAP_3

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2012 to 2026.

Full charge capacity 4 LEXUS_CAP_4

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2012 to 2026.

Full charge capacity 5 LEXUS_CAP_5

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2012 to 2026.

Full charge capacity 6 LEXUS_CAP_6

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2012 to 2026.

Full charge capacity 7 LEXUS_CAP_7

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2012 to 2026.

Full charge capacity 8 LEXUS_CAP_8

  • Request22 1D 3E
  • Service 22DID 1D3E
  • Module747 → 74F
  • Every60 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2012 to 2026.

High voltage battery charge control, kw LEXUS_HVBAT_CHG_CTRL_KW

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5
Unit
Number

In testing for 2012 to 2026.

High voltage battery discharge control, kw LEXUS_HVBAT_DCHG_CTRL_KW

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5
Unit
Number

In testing for 2012 to 2026.

High voltage battery intake air temperature LEXUS_HVBAT_IAT

  • Request21 87
  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0039047837 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

HV battery block 1 internal resistance LEXUS_HVBAT_BLOCK_1_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 1 voltage LEXUS_HVBAT_BLOCK_1_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 2 internal resistance LEXUS_HVBAT_BLOCK_2_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 2 voltage LEXUS_HVBAT_BLOCK_2_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 3 internal resistance LEXUS_HVBAT_BLOCK_3_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 3 voltage LEXUS_HVBAT_BLOCK_3_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 4 internal resistance LEXUS_HVBAT_BLOCK_4_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 4 voltage LEXUS_HVBAT_BLOCK_4_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 5 internal resistance LEXUS_HVBAT_BLOCK_5_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 5 voltage LEXUS_HVBAT_BLOCK_5_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 6 internal resistance LEXUS_HVBAT_BLOCK_6_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 6 voltage LEXUS_HVBAT_BLOCK_6_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 7 internal resistance LEXUS_HVBAT_BLOCK_7_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 7 voltage LEXUS_HVBAT_BLOCK_7_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 8 internal resistance LEXUS_HVBAT_BLOCK_8_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 8 voltage LEXUS_HVBAT_BLOCK_8_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 136 to 151 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 9 internal resistance LEXUS_HVBAT_BLOCK_9_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 9 voltage LEXUS_HVBAT_BLOCK_9_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 152 to 167 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 10 internal resistance LEXUS_HVBAT_BLOCK_10_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 10 voltage LEXUS_HVBAT_BLOCK_10_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 11 internal resistance LEXUS_HVBAT_BLOCK_11_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 11 voltage LEXUS_HVBAT_BLOCK_11_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 12 internal resistance LEXUS_HVBAT_BLOCK_12_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 12 voltage LEXUS_HVBAT_BLOCK_12_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 13 internal resistance LEXUS_HVBAT_BLOCK_13_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 13 voltage LEXUS_HVBAT_BLOCK_13_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block 14 internal resistance LEXUS_HVBAT_BLOCK_14_R

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
val
Range
0 to 255 mΩ
Unit
mΩ

In testing for 2012 to 2026.

HV battery block 14 voltage LEXUS_HVBAT_BLOCK_14_V

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block count LEXUS_HVBAT_BLOCKS

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

HV battery block voltage, highest LEXUS_HVBAT_BLOCK_V_MAX

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block voltage, lowest LEXUS_HVBAT_BLOCK_V_MIN

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 V
Unit
V

In testing for 2012 to 2026.

HV battery block with the highest voltage LEXUS_HVBAT_BLOCK_V_MAX_NO

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

HV battery block with the lowest voltage LEXUS_HVBAT_BLOCK_V_MIN_NO

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

HV battery charge LEXUS_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 2012 to 2026.

HV battery charge (max) LEXUS_HVBAT_SOC_MAX

  • Request22 10 6C
  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2012, 2014 to 2026. Not supported for 2013.

HV battery charge (min) LEXUS_HVBAT_SOC_MIN

  • Request22 10 6C
  • Service 22DID 106C
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

In testing for 2012, 2014 to 2026. Not supported for 2013.

HV battery charge power limit LEXUS_HVBAT_CHG_LIM

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 kW
Unit
kW

In testing for 2012 to 2026.

HV battery charge spread LEXUS_HVBAT_DELTA_SOC

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55 %
Unit
%

In testing for 2012 to 2026.

HV battery charge voltage LEXUS_HVBAT_CHRG_V

  • Request22 16 09
  • Service 22DID 1609
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 100 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery charge, displayed LEXUS_HVBAT_SOC_DISPLAY

Pelican can show this parameter as the state of charge.

  • Request22 17 39
  • Service 22DID 1739
  • Module745 → 74D
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery charge, hybrid control LEXUS_HV_SOC

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every1 s
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val × 0.392)
Range
0 to 99.96 %
Unit
%

In testing for 2012 to 2026.

HV battery current LEXUS_HVBAT_C

Pelican can show this parameter as the traction battery current.

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery current LEXUS_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Request21 CE
  • Service 21PID CE
  • Module7E3 → 7EB
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 A
Unit
A

In testing for 2012 to 2026.

HV battery DC inhibit time LEXUS_HVBAT_DC_INHIBIT_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2012 to 2026.

HV battery discharge power limit LEXUS_HVBAT_DISCHG_LIM

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 64)
Range
-64 to 191 kW
Unit
kW

In testing for 2012 to 2026.

HV battery discharge power limit LEXUS_WOUT

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 320)
Range
0 to 81600 W
Unit
W

In testing for 2012 to 2026.

HV battery fan motor voltage LEXUS_HVBAT_FAN_V

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 5 − 25.6)
Range
-25.6 to 25.4 V
Unit
V

In testing for 2012 to 2026.

HV battery fan speed LEXUS_HVBAT_FAN

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

HV battery high charge time LEXUS_HVBAT_HIGH_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2012 to 2026.

HV battery hot temperature time LEXUS_HVBAT_HOT_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2012 to 2026.

HV battery intake air temperature LEXUS_HVBAT_INTAKE_T

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2012 to 2026.

HV battery low charge time LEXUS_HVBAT_LOW_TIME

  • Request21 D0
  • Service 21PID D0
  • Module7E3 → 7EB
  • Every30 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2012 to 2026.

HV battery maximum temperature LEXUS_HVBAT_MAX_T

  • Request22 18 29
  • Service 22DID 1829
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery minimum temperature LEXUS_HVBAT_MIN_T

  • Request22 18 2A
  • Service 22DID 182A
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery temperature 1 LEXUS_HVBAT_T_1

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2012 to 2026.

HV battery temperature 1 LEXUS_T_BATT_TB1

  • Request21 87
  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0039047837 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

HV battery temperature 2 LEXUS_HVBAT_T_2

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2012 to 2026.

HV battery temperature 2 LEXUS_T_BATT_TB2

  • Request21 87
  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 0.0039047837 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

HV battery temperature 3 LEXUS_HVBAT_T_3

  • Request21 CF
  • Service 21PID CF
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67 °C
Unit
°C

In testing for 2012 to 2026.

HV battery temperature 3 LEXUS_T_BATT_TB3

  • Request21 87
  • Service 21PID 87
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 0.0039047837 − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2012 to 2026.

HV battery voltage LEXUS_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module7D2 → 7DA
  • Every500 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1023 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

Hybrid battery 1 fan LEXUS_HYBRID_BAT_1_FAN

  • Request22 18 02
  • Service 22DID 1802
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2012 to 2026.

Hybrid battery 1 fan LEXUS_HYBRID_BAT_1_FAN_747

  • Request22 18 02
  • Service 22DID 1802
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2012 to 2026.

Hybrid battery block 1 average voltage LEXUS_HYBRID_BAT_BLOCK_1_V

  • Request22 18 19
  • Service 22DID 1819
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65536)
Range
0 to 4.99 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery block 2 average voltage LEXUS_HYBRID_BAT_BLOCK_2_V

  • Request22 18 19
  • Service 22DID 1819
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 5 ÷ 65536)
Range
0 to 4.99 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery block 3 average voltage LEXUS_HYBRID_BAT_BLOCK_3_V

  • Request22 18 19
  • Service 22DID 1819
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 5 ÷ 65536)
Range
0 to 4.99 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery block 4 average voltage LEXUS_HYBRID_BAT_BLOCK_4_V

  • Request22 18 19
  • Service 22DID 1819
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 65536)
Range
0 to 4.99 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery block 5 average voltage LEXUS_HYBRID_BAT_BLOCK_5_V

  • Request22 18 19
  • Service 22DID 1819
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 5 ÷ 65536)
Range
0 to 4.99 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery current LEXUS_HYBRID_BAT_CURRENT

  • Request22 1F 9A
  • Service 22DID 1F9A
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 A
Unit
A

In testing for 2012 to 2026.

Hybrid battery heater temperature 2 LEXUS_HYBRID_BAT_HEATER_T_2

  • Request22 18 25
  • Service 22DID 1825
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 58)
Range
-58 to 401 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery intake air temperature 1 LEXUS_HYBRID_BAT_IAT_1

  • Request22 18 0B
  • Service 22DID 180B
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 458 ÷ 65535 − 58)
Range
-58 to 400 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery intake air temperature 2 LEXUS_HYBRID_BAT_IAT_2

  • Request22 18 0B
  • Service 22DID 180B
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 458 ÷ 65535 − 58)
Range
-58 to 400 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery SOC LEXUS_HYBRID_BAT_SOC

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2026.

Hybrid battery temperature 1 LEXUS_HYBRID_BAT_T_1

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 458 ÷ 65535 − 58)
Range
-58 to 400 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery temperature 2 LEXUS_HYBRID_BAT_T_2

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 9 ÷ 5 − 58)
Range
-58 to 401 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery temperature 3 LEXUS_HYBRID_BAT_T_3

  • Request22 18 14
  • Service 22DID 1814
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 458 ÷ 65535 − 58)
Range
-58 to 400 °F
Unit
°F

In testing for 2012 to 2026.

Hybrid battery voltage LEXUS_HYBRID_BAT_V

  • Request22 F1 9A
  • Service 22DID F19A
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 V
Unit
V

In testing for 2012 to 2026.

Hybrid battery voltage LEXUS_HYBRID_BAT_V_747

  • Request22 F1 9A
  • Service 22DID F19A
  • Module747 → 74F
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 V
Unit
V

In testing for 2012 to 2026.

Initial engine battery voltage lower limit LEXUS_INITIAL_ENG_BAT_V_LO

  • Request22 15 F6
  • Service 22DID 15F6
  • Module700 → 708
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2012 to 2026.

Inverter input voltage too high LEXUS_OVERVOLTAGE_INPUT_INVERTER

  • Request21 74
  • Service 21PID 74
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2026.

Last charge outcome code LEXUS_CHG_OUTCOME

  • Request22 16 88
  • Service 22DID 1688
  • Module745 → 74D
  • Every60 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

Main battery charging requested LEXUS_CHARGE_REQ

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2026.

Main connector solenoid current LEXUS_SMC_SOLENOID_CURRENTConfirmed

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 32 to 39 of the reply, 8 bits.

0x00 = 0 → 0 mA

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Main relay a, solenoid current LEXUS_SLA_SOLENOID_CURRENTConfirmed

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0 mA

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Main relay r solenoid current LEXUS_SLR_SOLENOID_CURRENTConfirmed

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0 mA

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Minimum permission power LEXUS_CHG_P_PERMIT

  • Request22 16 A1
  • Service 22DID 16A1
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 kW
Unit
kW

In testing for 2012 to 2026.

Number of battery blocks LEXUS_NUM_BAT_BLOCKS

  • Request21 92
  • Service 21PID 92
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

Output speed sensor voltage LEXUS_NOUT_SENS_V

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 V
Unit
V

In testing for 2012 to 2026.

Plug-in switch status LEXUS_PISW

  • Request22 16 69
  • Service 22DID 1669
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2012 to 2026.

Power resource current LEXUS_IB

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every1 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 2 − 256)
Range
-256 to 254 A
Unit
A

In testing for 2012 to 2026.

Power resource voltage LEXUS_VB

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 2012 to 2026.

Regenerative braking cooperation LEXUS_REGEN_COOPERATIONConfirmed

  • Request21 58
  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bit 0 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Regenerative operation LEXUS_FR_REGEN_OPERATIONConfirmed

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 16 to 31 of the reply, 16 bits.

0x0000 = 0 → 0 N·m

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Regenerative request LEXUS_FR_REGEN_REQUESTConfirmed

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0 N·m

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Relay control solenoid current LEXUS_SRC_SOLENOID_CURRENTConfirmed

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 40 to 47 of the reply, 8 bits.

0x00 = 0 → 0 mA

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Service contactor solenoid current LEXUS_SSC_SOLENOID_CURRENTConfirmed

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Example reply from a 2013 Lexus ES 300h.

Bits 16 to 23 of the reply, 8 bits.

0x23 = 35 → 35 mA

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2013. In testing for 2012, 2014 to 2026.

Short circuit wave highest value LEXUS_SHORT_WAVE_V

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 2012 to 2026.

Sleep time of battery sensor LEXUS_SLEEP_TIME_BATSENS

  • Request22 15 F0
  • Service 22DID 15F0
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 h
Unit
h

In testing for 2012 to 2026.

SOC at ignition on LEXUS_SOC_AFTER_IG_ON

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2012 to 2026.

SOC max LEXUS_SOC_MAX

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2012 to 2026.

SOC min LEXUS_SOC_MIN

  • Request21 98
  • Service 21PID 98
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2012 to 2026.

State of charge LEXUS_SOC

Pelican can show this parameter as the state of charge.

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module7D2
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

State of charge LEXUS_ST_CHG_ALL_BAT

  • Request21 01
  • Service 21PID 01
  • Module7E2 → 7EA
  • Every30 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2026.

State of charge LEXUS_STATE_OF_CHARGE

Pelican can show this parameter as the state of charge.

  • Request21 C3
  • Service 21PID C3
  • Module7E2
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.392)
Range
0 to 99.96 %
Unit
%

In testing for 2012 to 2026.

State of charge, battery ECU LEXUS_SOC_747

  • Request22 1F 5B
  • Service 22DID 1F5B
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 2012 to 2026.

State of charge, charging control LEXUS_SOC_745

  • Request22 17 38
  • Service 22DID 1738
  • Module745 → 74D
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2012 to 2026.

System main relay 1 LEXUS_SMR1

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 63 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2026.

System main relay 2 LEXUS_SMR2

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2026.

System main relay 3 LEXUS_SMR3

  • Request21 C4
  • Service 21PID C4
  • Module7E2
  • Every1 s
  • Testing

Bit 61 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2012 to 2026.

Target charging current LEXUS_CHG_A_TGT

  • Request22 16 6D
  • Service 22DID 166D
  • Module745 → 74D
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2012 to 2026.

Turbine speed sensor voltage LEXUS_NT_SENS_V

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 V
Unit
V

In testing for 2012 to 2026.

Vh-voltage after boosting LEXUS_VH_V_AFTER_BOOSTING

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

In testing for 2012 to 2026.

Vl-voltage before boosting LEXUS_VL_V_BEFORE_BOOSTING

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 V
Unit
V

In testing for 2012 to 2026.

Voltage of battery sensor LEXUS_V_BATSENS

  • Request22 15 EE
  • Service 22DID 15EE
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13333 ÷ 10922500)
Range
0 to 79.9979 V
Unit
V

In testing for 2012 to 2026.

Battery › Cells

HV battery cell #01 voltage LEXUS_HVBAT_C01_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #02 voltage LEXUS_HVBAT_C02_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #03 voltage LEXUS_HVBAT_C03_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #04 voltage LEXUS_HVBAT_C04_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #05 voltage LEXUS_HVBAT_C05_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #06 voltage LEXUS_HVBAT_C06_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #07 voltage LEXUS_HVBAT_C07_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #08 voltage LEXUS_HVBAT_C08_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #09 voltage LEXUS_HVBAT_C09_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #10 voltage LEXUS_HVBAT_C10_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #11 voltage LEXUS_HVBAT_C11_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #12 voltage LEXUS_HVBAT_C12_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #13 voltage LEXUS_HVBAT_C13_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #14 voltage LEXUS_HVBAT_C14_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #15 voltage LEXUS_HVBAT_C15_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #16 voltage LEXUS_HVBAT_C16_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #17 voltage LEXUS_HVBAT_C17_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #18 voltage LEXUS_HVBAT_C18_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #19 voltage LEXUS_HVBAT_C19_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #20 voltage LEXUS_HVBAT_C20_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #21 voltage LEXUS_HVBAT_C21_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #22 voltage LEXUS_HVBAT_C22_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #23 voltage LEXUS_HVBAT_C23_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #24 voltage LEXUS_HVBAT_C24_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #25 voltage LEXUS_HVBAT_C25_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #26 voltage LEXUS_HVBAT_C26_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #27 voltage LEXUS_HVBAT_C27_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #28 voltage LEXUS_HVBAT_C28_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #29 voltage LEXUS_HVBAT_C29_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #30 voltage LEXUS_HVBAT_C30_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #31 voltage LEXUS_HVBAT_C31_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #32 voltage LEXUS_HVBAT_C32_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #33 voltage LEXUS_HVBAT_C33_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #34 voltage LEXUS_HVBAT_C34_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #35 voltage LEXUS_HVBAT_C35_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #36 voltage LEXUS_HVBAT_C36_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #37 voltage LEXUS_HVBAT_C37_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #38 voltage LEXUS_HVBAT_C38_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #39 voltage LEXUS_HVBAT_C39_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #40 voltage LEXUS_HVBAT_C40_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #41 voltage LEXUS_HVBAT_C41_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #42 voltage LEXUS_HVBAT_C42_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #43 voltage LEXUS_HVBAT_C43_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #44 voltage LEXUS_HVBAT_C44_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #45 voltage LEXUS_HVBAT_C45_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #46 voltage LEXUS_HVBAT_C46_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #47 voltage LEXUS_HVBAT_C47_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #48 voltage LEXUS_HVBAT_C48_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #49 voltage LEXUS_HVBAT_C49_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #50 voltage LEXUS_HVBAT_C50_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #51 voltage LEXUS_HVBAT_C51_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #52 voltage LEXUS_HVBAT_C52_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #53 voltage LEXUS_HVBAT_C53_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #54 voltage LEXUS_HVBAT_C54_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #55 voltage LEXUS_HVBAT_C55_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #56 voltage LEXUS_HVBAT_C56_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #57 voltage LEXUS_HVBAT_C57_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #58 voltage LEXUS_HVBAT_C58_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #59 voltage LEXUS_HVBAT_C59_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #60 voltage LEXUS_HVBAT_C60_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #61 voltage LEXUS_HVBAT_C61_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #62 voltage LEXUS_HVBAT_C62_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #63 voltage LEXUS_HVBAT_C63_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #64 voltage LEXUS_HVBAT_C64_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #65 voltage LEXUS_HVBAT_C65_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #66 voltage LEXUS_HVBAT_C66_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #67 voltage LEXUS_HVBAT_C67_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #68 voltage LEXUS_HVBAT_C68_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #69 voltage LEXUS_HVBAT_C69_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #70 voltage LEXUS_HVBAT_C70_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #71 voltage LEXUS_HVBAT_C71_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #72 voltage LEXUS_HVBAT_C72_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #73 voltage LEXUS_HVBAT_C73_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #74 voltage LEXUS_HVBAT_C74_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #75 voltage LEXUS_HVBAT_C75_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #76 voltage LEXUS_HVBAT_C76_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #77 voltage LEXUS_HVBAT_C77_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #78 voltage LEXUS_HVBAT_C78_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #79 voltage LEXUS_HVBAT_C79_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #80 voltage LEXUS_HVBAT_C80_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #81 voltage LEXUS_HVBAT_C81_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #82 voltage LEXUS_HVBAT_C82_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #83 voltage LEXUS_HVBAT_C83_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #84 voltage LEXUS_HVBAT_C84_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #85 voltage LEXUS_HVBAT_C85_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #86 voltage LEXUS_HVBAT_C86_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #87 voltage LEXUS_HVBAT_C87_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #88 voltage LEXUS_HVBAT_C88_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #89 voltage LEXUS_HVBAT_C89_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #90 voltage LEXUS_HVBAT_C90_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #91 voltage LEXUS_HVBAT_C91_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #92 voltage LEXUS_HVBAT_C92_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #93 voltage LEXUS_HVBAT_C93_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #94 voltage LEXUS_HVBAT_C94_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #95 voltage LEXUS_HVBAT_C95_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

HV battery cell #96 voltage LEXUS_HVBAT_C96_V

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

Battery › Modules › 01

HV battery module 01 voltage LEXUS_HVBAT_CMU01_VOLT

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

Battery › Modules › 02

HV battery module 02 voltage LEXUS_HVBAT_CMU02_VOLT

  • Request22 18 2E
  • Service 22DID 182E
  • Module747 → 74F
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 2012, 2014 to 2018, 2020 to 2026. Not supported for 2013, 2019.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.