LINCOLN_TIP parameters
The Lincoln Navigator has 2 LINCOLN_TIP parameters.
● Confirmed◆ In testing○ Supported× Not supported
Throttle inlet pressure absolute LINCOLN_TIP_ABSConfirmed
- Request
22 03 3E - Service 22
DID 033E - Module
7E0 → 7E8 - Every
250 ms - Testing
Example reply from a 2021 Lincoln Navigator.
Bits 0 to 15 of the reply, 16 bits.
0x30AB = 12459 → (12459 × 0.0011064263) = 13.784965 psi
- Formula
(val × 0.0011064263)- Range
- 0 to 60 psi
- Unit
- psi
Confirmed for 2021. In testing for 1998 to 2020, 2022 to 2026.
Throttle inlet pressure sensor voltage LINCOLN_TIP_VConfirmed
- Request
22 03 3C - Service 22
DID 033C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0048828125)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2021. In testing for 1998 to 2020, 2022 to 2026.