MG One

Engine parameters

The MG One has 13 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air flow rate from mass air flow sensor MAFConfirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2024.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Engine oil pressure MG_EOP

  • Request22 B0 36
  • Service 22DID B036
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 229 ÷ 10000)
Range
0 to 1500.7515 kPa
Unit
kPa

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Engine oil temperature MG_EO_T

  • Request22 B0 34
  • Service 22DID B034
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Ignition state MG_IGN

  • Request22 B1 8C
  • Service 22DID B18C
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfires, cylinder 1 MG_MISFIRES_C1

  • Request22 B1 43
  • Service 22DID B143
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfires, cylinder 2 MG_MISFIRES_C2

  • Request22 B1 44
  • Service 22DID B144
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfires, cylinder 3 MG_MISFIRES_C3

  • Request22 B1 45
  • Service 22DID B145
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Misfires, cylinder 4 MG_MISFIRES_C4

  • Request22 B1 46
  • Service 22DID B146
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Radiator fan state MG_RAD_FAN

  • Request22 BB 91
  • Service 22DID BB91
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2024.

Transmission fluid temperature, ECU 10472701 and 11194479 MG_ATF_T_ECU_10472701_11194479

  • Request22 B4 23
  • Service 22DID B423
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Transmission fluid temperature, ECU 10513229 MG_ATF_T_ECU_10513229

  • Request22 19 40
  • Service 22DID 1940
  • Module7E1
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2023, 2025 to 2026. Not supported for 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.