Peugeot 508

Battery parameters

The Peugeot 508 has 34 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Accelerator pedal signal 1 voltage 508_ACCEL_PEDAL_SIG_1_V

  • Request22 D4 05
  • Service 22DID D405
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5000.000126)
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Accelerator pedal signal 1 voltage 508_ACCEL_PEDAL_SIG_1_V

  • Request22 D4 05
  • Service 22DID D405
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5000.000126)
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Accelerator pedal signal 2 voltage 508_ACCEL_PEDAL_SIG_2_V

  • Request22 D4 06
  • Service 22DID D406
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5000.000126)
Range
-6.55 to 6.55 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Approximate position of turbocharger actuator 508_APPROXIMATE_POS

  • Request22 D4 EC
  • Service 22DID D4EC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Battery current 508_BAT_CURRENT

  • Request22 D4 97
  • Service 22DID D497
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 1024)
Range
-2097152 to 2097151 A
Unit
A

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Centralized voltage maintenance device temperature limiter state 508_CENTRALIZED_V_T

  • Request22 D7 59
  • Service 22DID D759
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Computer power supply voltage 508_COMPUTER_POWER_SUP_V

  • Request22 D5 51
  • Service 22DID D551
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.

Energy accumulator discharge permission state 508_ENERGY_ACCUMULATOR

  • Request22 D7 4F
  • Service 22DID D74F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine control computer supply voltage 508_ENG_CTRL_COMPUTER_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 D4 22
  • Service 22DID D422
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine oil level sensor voltage 508_ENG_OIL_LEVEL_SENS_V

  • Request22 D4 1E
  • Service 22DID D41E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 5)
Range
-6553 to 6553 mV
Unit
mV

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Evaluation of the total resistance of the voltage maintaining device 508_EVALUATION_TOT_RES_V

  • Request22 D7 2D
  • Service 22DID D72D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128040.9703)
Range
0 to 0.511
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Glow plug unit supply voltage 508_PREHEATING_V

  • Request22 D5 0E
  • Service 22DID D50E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Minimum battery voltage at startup 508_MIN_BAT_V_STARTUP

  • Request22 D4 D4
  • Service 22DID D4D4
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50.00000112)
Range
-655 to 655 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Reversible generator voltage 508_REVERSIBLE_GEN_V

  • Request22 D7 13
  • Service 22DID D713
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Service battery charge state 508_SERVICE_BAT_CHG_ST

  • Request22 D7 42
  • Service 22DID D742
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Service battery charge status 508_SERVICE_BAT_CHG_STAT

  • Request22 D4 67
  • Service 22DID D467
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Service battery temperature 508_SERVICE_BAT_T_6A8

  • Request22 D4 96
  • Service 22DID D496
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Service battery voltage 508_SERVICE_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 D7 8A
  • Service 22DID D78A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Service battery wear condition 508_SERVICE_BAT_WEAR

  • Request22 D7 41
  • Service 22DID D741
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Set voltage of energy storage 508_SET_V_ENERGY_STORAGE

  • Request22 D7 34
  • Service 22DID D734
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 32)
Range
0 to 7.96 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Set voltage of storage battery charging 508_SET_V_STORAGE_BAT

  • Request22 D7 66
  • Service 22DID D766
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Set voltage of the reversible generator 508_SET_V_REVERSIBLE_GEN

  • Request22 D7 12
  • Service 22DID D712
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 39.9999994 + 10.60000038)
Range
0 to 16.97 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Stop permitted by voltage maintainer computer 508_STOP_PERMITTED_V

  • Request22 D7 49
  • Service 22DID D749
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Temperature of the electronic power unit of the voltage maintenance device 508_T_ELECTRONIC_POWER_V

  • Request22 D7 30
  • Service 22DID D730
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Turbocharger control duty cycle 508_TURBOCHARGER_CTRL

  • Request22 D4 8A
  • Service 22DID D48A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 256)
Range
-128 to 127 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Turbocharger first electronic boost 508_TURBOCHARGER_FIRST

  • Request22 D4 8C
  • Service 22DID D48C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Turbocharger position information 508_TURBOCHARGER_POS

  • Request22 D4 EA
  • Service 22DID D4EA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100.0000022)
Range
0 to 655 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Turbocharger pressure measured 508_TURBOCHARGER_P_MEAS

  • Request22 D4 D9
  • Service 22DID D4D9
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Turbocharger pressure reference 508_TURBOCHARGER_P

  • Request22 D5 56
  • Service 22DID D556
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Turbocharger, target position 508_TURBOCHARGER_TGT_POS

  • Request22 D4 7B
  • Service 22DID D47B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Voltage at the terminals of the energy accumulator 508_V_TERMINALS_ENERGY

  • Request22 D7 20
  • Service 22DID D720
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 32)
Range
0 to 7.96 V
Unit
V

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Voltage maintainer computer request sent 508_V_MAINTAINER_COMPUTER_REQ

  • Request22 D7 48
  • Service 22DID D748
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Voltage maintainer computer restart permission 508_V_MAINTAINER

  • Request22 D7 47
  • Service 22DID D747
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Voltage maintainer status 508_V_MAINTAINER_STAT

  • Request22 D7 2C
  • Service 22DID D72C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.