Battery parameters
The Seat Mii Electric has 189 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery voltage MII_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 5A - Service 22
DID 105A - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700 mV
- Unit
- mV
In testing for 2019 to 2021.
Charger AC input current MII_CHG_AC_I
- Request
22 1D A8 - Service 22
DID 1DA8 - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2019 to 2021.
Charger AC input current setpoint MII_CHG_AC_I_SET
- Request
22 15 D3 - Service 22
DID 15D3 - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2019 to 2021.
Charger AC input voltage MII_CHG_AC_V
- Request
22 1D A9 - Service 22
DID 1DA9 - Module
744 - Every
30 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2019 to 2021.
Charger DC link voltage MII_CHG_LINK_V
- Request
22 15 DB - Service 22
DID 15DB - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2019 to 2021.
Charger DC to DC coil temperature MII_CHG_DCDC_COIL_T
- Request
22 15 DA - Service 22
DID 15DA - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2021.
Charger DC to DC gate driver voltage MII_CHG_DCDC_GATE_V
- Request
22 15 DD - Service 22
DID 15DD - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2019 to 2021.
Charger DC to DC power line temperature MII_CHG_DCDC_LINE_T
- Request
22 15 EC - Service 22
DID 15EC - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2021.
Charger output current MII_CHG_HV_I
- Request
22 42 37 - Service 22
DID 4237 - Module
744 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.749 A
- Unit
- A
In testing for 2019 to 2021.
Charger output current setpoint MII_CHG_HV_I_SET
- Request
22 42 38 - Service 22
DID 4238 - Module
744 - Every
30 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.749 A
- Unit
- A
In testing for 2019 to 2021.
Charger output voltage MII_CHG_OUT_V
- Request
22 1D A7 - Service 22
DID 1DA7 - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2019 to 2021.
Charger power factor coil temperature MII_CHG_PFC_COIL_T
- Request
22 15 D9 - Service 22
DID 15D9 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2021.
Charger power factor gate driver voltage MII_CHG_PFC_GATE_V
- Request
22 15 DC - Service 22
DID 15DC - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2019 to 2021.
Charger power loss MII_CHG_PWR_LOSS
- Request
22 15 E1 - Service 22
DID 15E1 - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20)- Range
- 0 to 5100 W
- Unit
- W
In testing for 2019 to 2021.
Charger temperature MII_CHG_T
- Request
22 15 D8 - Service 22
DID 15D8 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2021.
Charging efficiency MII_CHG_EFFICIENCY
- Request
22 15 D6 - Service 22
DID 15D6 - Module
744 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 75)- Range
- 0 to 100.499 %
- Unit
- %
In testing for 2019 to 2021.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2020.
DC to DC converter circuit board temperature MII_DCDC_PCB_T
- Request
22 46 4E - Service 22
DID 464E - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
DC to DC converter high-voltage side voltage MII_DCDC_HV_V
- Request
22 15 87 - Service 22
DID 1587 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.
DC to DC converter link voltage MII_DCDC_LINK_V
- Request
22 3E 72 - Service 22
DID 3E72 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.
DC to DC converter power stage temperature MII_DCDC_PWR_T
- Request
22 46 4F - Service 22
DID 464F - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
DC to DC converter regulated output voltage MII_PE_DCDC_KL30_V
- Request
22 46 5C - Service 22
DID 465C - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 V
- Unit
- V
In testing for 2019 to 2021.
DC to DC converter temperature MII_PE_DCDC_T
- Request
22 3E B5 - Service 22
DID 3EB5 - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
DC to DC converter traction current MII_DCDC_HV_I
- Request
22 46 50 - Service 22
DID 4650 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 A
- Unit
- A
In testing for 2019 to 2021.
DC to DC converter traction voltage MII_PE_DCDC_HV_V
- Request
22 46 5E - Service 22
DID 465E - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.
HV battery capacity MII_HVBAT_CAP
Total possible energy in the high voltage battery
- Request
22 2A B2 - Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1310770)- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2019, 2021. Not supported for 2020.
HV battery cell 1 voltage MII_HVBAT_CELL_1_V
- Request
22 1E 40 - Service 22
DID 1E40 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 2 voltage MII_HVBAT_CELL_2_V
- Request
22 1E 41 - Service 22
DID 1E41 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 3 voltage MII_HVBAT_CELL_3_V
- Request
22 1E 42 - Service 22
DID 1E42 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 4 voltage MII_HVBAT_CELL_4_V
- Request
22 1E 43 - Service 22
DID 1E43 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 5 voltage MII_HVBAT_CELL_5_V
- Request
22 1E 44 - Service 22
DID 1E44 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 6 voltage MII_HVBAT_CELL_6_V
- Request
22 1E 45 - Service 22
DID 1E45 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 7 voltage MII_HVBAT_CELL_7_V
- Request
22 1E 46 - Service 22
DID 1E46 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 8 voltage MII_HVBAT_CELL_8_V
- Request
22 1E 47 - Service 22
DID 1E47 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 9 voltage MII_HVBAT_CELL_9_V
- Request
22 1E 48 - Service 22
DID 1E48 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 10 voltage MII_HVBAT_CELL_10_V
- Request
22 1E 49 - Service 22
DID 1E49 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 11 voltage MII_HVBAT_CELL_11_V
- Request
22 1E 4A - Service 22
DID 1E4A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 12 voltage MII_HVBAT_CELL_12_V
- Request
22 1E 4B - Service 22
DID 1E4B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 13 voltage MII_HVBAT_CELL_13_V
- Request
22 1E 4C - Service 22
DID 1E4C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 14 voltage MII_HVBAT_CELL_14_V
- Request
22 1E 4D - Service 22
DID 1E4D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 15 voltage MII_HVBAT_CELL_15_V
- Request
22 1E 4E - Service 22
DID 1E4E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 16 voltage MII_HVBAT_CELL_16_V
- Request
22 1E 4F - Service 22
DID 1E4F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 17 voltage MII_HVBAT_CELL_17_V
- Request
22 1E 50 - Service 22
DID 1E50 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 18 voltage MII_HVBAT_CELL_18_V
- Request
22 1E 51 - Service 22
DID 1E51 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 19 voltage MII_HVBAT_CELL_19_V
- Request
22 1E 52 - Service 22
DID 1E52 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 20 voltage MII_HVBAT_CELL_20_V
- Request
22 1E 53 - Service 22
DID 1E53 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 21 voltage MII_HVBAT_CELL_21_V
- Request
22 1E 54 - Service 22
DID 1E54 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 22 voltage MII_HVBAT_CELL_22_V
- Request
22 1E 55 - Service 22
DID 1E55 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 23 voltage MII_HVBAT_CELL_23_V
- Request
22 1E 56 - Service 22
DID 1E56 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 24 voltage MII_HVBAT_CELL_24_V
- Request
22 1E 57 - Service 22
DID 1E57 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 25 voltage MII_HVBAT_CELL_25_V
- Request
22 1E 58 - Service 22
DID 1E58 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 26 voltage MII_HVBAT_CELL_26_V
- Request
22 1E 59 - Service 22
DID 1E59 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 27 voltage MII_HVBAT_CELL_27_V
- Request
22 1E 5A - Service 22
DID 1E5A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 28 voltage MII_HVBAT_CELL_28_V
- Request
22 1E 5B - Service 22
DID 1E5B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 29 voltage MII_HVBAT_CELL_29_V
- Request
22 1E 5C - Service 22
DID 1E5C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 30 voltage MII_HVBAT_CELL_30_V
- Request
22 1E 5D - Service 22
DID 1E5D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 31 voltage MII_HVBAT_CELL_31_V
- Request
22 1E 5E - Service 22
DID 1E5E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 32 voltage MII_HVBAT_CELL_32_V
- Request
22 1E 5F - Service 22
DID 1E5F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 33 voltage MII_HVBAT_CELL_33_V
- Request
22 1E 60 - Service 22
DID 1E60 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 34 voltage MII_HVBAT_CELL_34_V
- Request
22 1E 61 - Service 22
DID 1E61 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 35 voltage MII_HVBAT_CELL_35_V
- Request
22 1E 62 - Service 22
DID 1E62 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 36 voltage MII_HVBAT_CELL_36_V
- Request
22 1E 63 - Service 22
DID 1E63 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 37 voltage MII_HVBAT_CELL_37_V
- Request
22 1E 64 - Service 22
DID 1E64 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 38 voltage MII_HVBAT_CELL_38_V
- Request
22 1E 65 - Service 22
DID 1E65 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 39 voltage MII_HVBAT_CELL_39_V
- Request
22 1E 66 - Service 22
DID 1E66 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 40 voltage MII_HVBAT_CELL_40_V
- Request
22 1E 67 - Service 22
DID 1E67 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 41 voltage MII_HVBAT_CELL_41_V
- Request
22 1E 68 - Service 22
DID 1E68 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 42 voltage MII_HVBAT_CELL_42_V
- Request
22 1E 69 - Service 22
DID 1E69 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 43 voltage MII_HVBAT_CELL_43_V
- Request
22 1E 6A - Service 22
DID 1E6A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 44 voltage MII_HVBAT_CELL_44_V
- Request
22 1E 6B - Service 22
DID 1E6B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 45 voltage MII_HVBAT_CELL_45_V
- Request
22 1E 6C - Service 22
DID 1E6C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 46 voltage MII_HVBAT_CELL_46_V
- Request
22 1E 6D - Service 22
DID 1E6D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 47 voltage MII_HVBAT_CELL_47_V
- Request
22 1E 6E - Service 22
DID 1E6E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 48 voltage MII_HVBAT_CELL_48_V
- Request
22 1E 6F - Service 22
DID 1E6F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 49 voltage MII_HVBAT_CELL_49_V
- Request
22 1E 70 - Service 22
DID 1E70 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 50 voltage MII_HVBAT_CELL_50_V
- Request
22 1E 71 - Service 22
DID 1E71 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 51 voltage MII_HVBAT_CELL_51_V
- Request
22 1E 72 - Service 22
DID 1E72 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 52 voltage MII_HVBAT_CELL_52_V
- Request
22 1E 73 - Service 22
DID 1E73 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 53 voltage MII_HVBAT_CELL_53_V
- Request
22 1E 74 - Service 22
DID 1E74 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 54 voltage MII_HVBAT_CELL_54_V
- Request
22 1E 75 - Service 22
DID 1E75 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 55 voltage MII_HVBAT_CELL_55_V
- Request
22 1E 76 - Service 22
DID 1E76 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 56 voltage MII_HVBAT_CELL_56_V
- Request
22 1E 77 - Service 22
DID 1E77 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 57 voltage MII_HVBAT_CELL_57_V
- Request
22 1E 78 - Service 22
DID 1E78 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 58 voltage MII_HVBAT_CELL_58_V
- Request
22 1E 79 - Service 22
DID 1E79 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 59 voltage MII_HVBAT_CELL_59_V
- Request
22 1E 7A - Service 22
DID 1E7A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 60 voltage MII_HVBAT_CELL_60_V
- Request
22 1E 7B - Service 22
DID 1E7B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 61 voltage MII_HVBAT_CELL_61_V
- Request
22 1E 7C - Service 22
DID 1E7C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 62 voltage MII_HVBAT_CELL_62_V
- Request
22 1E 7D - Service 22
DID 1E7D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 63 voltage MII_HVBAT_CELL_63_V
- Request
22 1E 7E - Service 22
DID 1E7E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 64 voltage MII_HVBAT_CELL_64_V
- Request
22 1E 7F - Service 22
DID 1E7F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 65 voltage MII_HVBAT_CELL_65_V
- Request
22 1E 80 - Service 22
DID 1E80 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 66 voltage MII_HVBAT_CELL_66_V
- Request
22 1E 81 - Service 22
DID 1E81 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 67 voltage MII_HVBAT_CELL_67_V
- Request
22 1E 82 - Service 22
DID 1E82 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 68 voltage MII_HVBAT_CELL_68_V
- Request
22 1E 83 - Service 22
DID 1E83 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 69 voltage MII_HVBAT_CELL_69_V
- Request
22 1E 84 - Service 22
DID 1E84 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 70 voltage MII_HVBAT_CELL_70_V
- Request
22 1E 85 - Service 22
DID 1E85 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 71 voltage MII_HVBAT_CELL_71_V
- Request
22 1E 86 - Service 22
DID 1E86 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 72 voltage MII_HVBAT_CELL_72_V
- Request
22 1E 87 - Service 22
DID 1E87 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 73 voltage MII_HVBAT_CELL_73_V
- Request
22 1E 88 - Service 22
DID 1E88 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 74 voltage MII_HVBAT_CELL_74_V
- Request
22 1E 89 - Service 22
DID 1E89 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 75 voltage MII_HVBAT_CELL_75_V
- Request
22 1E 8A - Service 22
DID 1E8A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 76 voltage MII_HVBAT_CELL_76_V
- Request
22 1E 8B - Service 22
DID 1E8B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 77 voltage MII_HVBAT_CELL_77_V
- Request
22 1E 8C - Service 22
DID 1E8C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 78 voltage MII_HVBAT_CELL_78_V
- Request
22 1E 8D - Service 22
DID 1E8D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 79 voltage MII_HVBAT_CELL_79_V
- Request
22 1E 8E - Service 22
DID 1E8E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 80 voltage MII_HVBAT_CELL_80_V
- Request
22 1E 8F - Service 22
DID 1E8F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 81 voltage MII_HVBAT_CELL_81_V
- Request
22 1E 90 - Service 22
DID 1E90 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 82 voltage MII_HVBAT_CELL_82_V
- Request
22 1E 91 - Service 22
DID 1E91 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 83 voltage MII_HVBAT_CELL_83_V
- Request
22 1E 92 - Service 22
DID 1E92 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 84 voltage MII_HVBAT_CELL_84_V
- Request
22 1E 93 - Service 22
DID 1E93 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 85 voltage MII_HVBAT_CELL_85_V
- Request
22 1E 94 - Service 22
DID 1E94 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 86 voltage MII_HVBAT_CELL_86_V
- Request
22 1E 95 - Service 22
DID 1E95 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 87 voltage MII_HVBAT_CELL_87_V
- Request
22 1E 96 - Service 22
DID 1E96 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 88 voltage MII_HVBAT_CELL_88_V
- Request
22 1E 97 - Service 22
DID 1E97 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 89 voltage MII_HVBAT_CELL_89_V
- Request
22 1E 98 - Service 22
DID 1E98 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 90 voltage MII_HVBAT_CELL_90_V
- Request
22 1E 99 - Service 22
DID 1E99 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 91 voltage MII_HVBAT_CELL_91_V
- Request
22 1E 9A - Service 22
DID 1E9A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 92 voltage MII_HVBAT_CELL_92_V
- Request
22 1E 9B - Service 22
DID 1E9B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 93 voltage MII_HVBAT_CELL_93_V
- Request
22 1E 9C - Service 22
DID 1E9C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 94 voltage MII_HVBAT_CELL_94_V
- Request
22 1E 9D - Service 22
DID 1E9D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 95 voltage MII_HVBAT_CELL_95_V
- Request
22 1E 9E - Service 22
DID 1E9E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 96 voltage MII_HVBAT_CELL_96_V
- Request
22 1E 9F - Service 22
DID 1E9F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 97 voltage MII_HVBAT_CELL_97_V
- Request
22 1E A0 - Service 22
DID 1EA0 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 98 voltage MII_HVBAT_CELL_98_V
- Request
22 1E A1 - Service 22
DID 1EA1 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 99 voltage MII_HVBAT_CELL_99_V
- Request
22 1E A2 - Service 22
DID 1EA2 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 100 voltage MII_HVBAT_CELL_100_V
- Request
22 1E A3 - Service 22
DID 1EA3 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 101 voltage MII_HVBAT_CELL_101_V
- Request
22 1E A4 - Service 22
DID 1EA4 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell 102 voltage MII_HVBAT_CELL_102_V
- Request
22 1E A5 - Service 22
DID 1EA5 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell voltage sum MII_HVBAT_CELL_SUM_V
- Request
22 1E 3C - Service 22
DID 1E3C - Module
7E5 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 4095.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell voltage, maximum MII_HVBAT_CELL_V_MAX
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery cell voltage, minimum MII_HVBAT_CELL_V_MIN
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2019 to 2021.
HV battery charge MII_HVBAT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
7E5 → 7ED - Every
30 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 7 of the reply, 8 bits.
0xAF = 175 → (175 × 100 ÷ 255) = 68.627451 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2019, 2021.
HV battery charge current limit MII_HVBAT_CHG_I_LIM
- Request
22 1E 1B - Service 22
DID 1E1B - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2019 to 2021.
HV battery charge current limit, predicted MII_HVBAT_CHG_I_LIM_PRED
- Request
22 1E 1D - Service 22
DID 1E1D - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2019 to 2021.
HV battery charge throughput MII_HVBAT_AH_CHGConfirmed
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 31 of the reply, 32 bits.
0x00A7B916 = 10991894 → (10991894 ÷ 549.31642) = 20,010.13187 Ah
- Formula
(val ÷ 549.31642)- Range
- 0 to 7818700 Ah
- Unit
- Ah
Confirmed for 2020. In testing for 2019, 2021.
HV battery charge, displayed MII_HVBAT_SOC_DISPConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 11 64 - Service 22
DID 1164 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x1B73 = 7027 → (7027 ÷ 100) = 70.27 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2019, 2021.
HV battery charge, normalized MII_PE_SOC
- Request
22 F4 04 - Service 22
DID F404 - Module
7E6 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2021.
HV battery coldest sensor MII_HVBAT_T_MIN_NO
- Request
22 1E 0F - Service 22
DID 1E0F - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2021.
HV battery current MII_HVBAT_IConfirmed
Pelican can show this parameter as the traction battery current.
- Request
22 1E 3D - Service 22
DID 1E3D - Module
7E5 → 7ED - Every
250 ms - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x0714 = 1812 → (1812 ÷ 4 − 511) = -58 A
- Formula
(val ÷ 4 − 511)- Range
- -200 to 200 A
- Unit
- A
Confirmed for 2020. In testing for 2019, 2021.
HV battery discharge current limit MII_HVBAT_DISCHG_I_LIM
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2019 to 2021.
HV battery discharge current limit, predicted MII_HVBAT_DISCHG_I_LIM_PRED
- Request
22 1E 1E - Service 22
DID 1E1E - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2019 to 2021.
HV battery discharge throughput MII_HVBAT_AH_DISCHGConfirmed
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 32 to 63 of the reply, 32 bits. The value is signed.
0xFF55EB20 = -11146464 → (-11146464 ÷ 549.31642) = -20,291.51796 Ah
- Formula
(val ÷ 549.31642)- Range
- -3909350 to 3909350 Ah
- Unit
- Ah
Confirmed for 2020. In testing for 2019, 2021.
HV battery energy MII_HVBAT_KWH
Energy stored in the high voltage battery
- Request
22 2A B8 - Service 22
DID 2AB8 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1310770)- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2019, 2021. Not supported for 2020.
HV battery energy charged MII_HVBAT_KWH_CHGConfirmed
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 64 to 95 of the reply, 32 bits.
0x0350C99C = 55626140 → (55626140 ÷ 8583.07212) = 6,480.912571 kWh
- Formula
(val ÷ 8583.07212)- Range
- 0 to 500300 kWh
- Unit
- kWh
Confirmed for 2020. In testing for 2019, 2021.
HV battery energy discharged MII_HVBAT_KWH_DISCHGConfirmed
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 96 to 127 of the reply, 32 bits. The value is signed.
0xFCB8034C = -55049396 → (-55049396 ÷ 8583.07212) = -6,413.71705 kWh
- Formula
(val ÷ 8583.07212)- Range
- -250300 to 250300 kWh
- Unit
- kWh
Confirmed for 2020. In testing for 2019, 2021.
HV battery health MII_HVBAT_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
22 51 E0 - Service 22
DID 51E0 - Module
7E5 → 7ED - Every
30 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x39EE = 14830 → (14830 × 0.127 − 1798.574) = 84.836 %
- Formula
(val × 0.127 − 1798.574)- Range
- -1798.574 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2019, 2021.
HV battery highest cell MII_HVBAT_CELL_V_MAX_NO
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2021.
HV battery hottest sensor MII_HVBAT_T_MAX_NO
- Request
22 1E 0E - Service 22
DID 1E0E - Module
7E5 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2021.
HV battery isolation resistance, negative MII_HVBAT_ISO_NEG
- Request
22 1E 1A - Service 22
DID 1E1A - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2019 to 2021.
HV battery isolation resistance, positive MII_HVBAT_ISO_POS
- Request
22 1E 18 - Service 22
DID 1E18 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2019 to 2021.
HV battery lowest cell MII_HVBAT_CELL_V_MIN_NO
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2021.
HV battery maximum power MII_HVBAT_PWR_MAX
- Request
22 15 02 - Service 22
DID 1502 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4)- Range
- 0 to 262140 W
- Unit
- W
In testing for 2019 to 2021.
HV battery negative voltage before the contactors MII_HVBAT_NEG_V_PRE
- Request
22 1E 35 - Service 22
DID 1E35 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 V
- Unit
- V
In testing for 2019 to 2021.
HV battery positive voltage after the charging contactors MII_HVBAT_POS_V_POST_CHG
- Request
22 1E 39 - Service 22
DID 1E39 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 V
- Unit
- V
In testing for 2019 to 2021.
HV battery positive voltage before the contactors MII_HVBAT_POS_V_PRE
- Request
22 1E 36 - Service 22
DID 1E36 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.
HV battery power MII_HVBAT_PWR
- Request
22 14 85 - Service 22
DID 1485 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 kW
- Unit
- kW
In testing for 2019 to 2021.
HV battery relative temperature MII_HVBAT_T_REL
- Request
22 14 9B - Service 22
DID 149B - Module
7E0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2019 to 2021.
HV battery remaining charge MII_HVBAT_REMAINING
- Request
22 F4 5B - Service 22
DID F45B - Module
7E0 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2021.
HV battery temperature MII_HVBAT_T
- Request
22 2A 0B - Service 22
DID 2A0B - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature load MII_HVBAT_T_LOAD
- Request
22 11 65 - Service 22
DID 1165 - Module
7E0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2019 to 2021.
HV battery temperature sensor 1 MII_HVBAT_T_1
- Request
22 1E AE - Service 22
DID 1EAE - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 2 MII_HVBAT_T_2
- Request
22 1E AF - Service 22
DID 1EAF - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 3 MII_HVBAT_T_3
- Request
22 1E B0 - Service 22
DID 1EB0 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 4 MII_HVBAT_T_4
- Request
22 1E B1 - Service 22
DID 1EB1 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 5 MII_HVBAT_T_5
- Request
22 1E B2 - Service 22
DID 1EB2 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 6 MII_HVBAT_T_6
- Request
22 1E B3 - Service 22
DID 1EB3 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 7 MII_HVBAT_T_7
- Request
22 1E B4 - Service 22
DID 1EB4 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 8 MII_HVBAT_T_8
- Request
22 1E B5 - Service 22
DID 1EB5 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 9 MII_HVBAT_T_9
- Request
22 1E B6 - Service 22
DID 1EB6 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 10 MII_HVBAT_T_10
- Request
22 1E B7 - Service 22
DID 1EB7 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 11 MII_HVBAT_T_11
- Request
22 1E B8 - Service 22
DID 1EB8 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 12 MII_HVBAT_T_12
- Request
22 1E B9 - Service 22
DID 1EB9 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 13 MII_HVBAT_T_13
- Request
22 1E BA - Service 22
DID 1EBA - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 15 MII_HVBAT_T_15
- Request
22 1E BC - Service 22
DID 1EBC - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 16 MII_HVBAT_T_16
- Request
22 1E BD - Service 22
DID 1EBD - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature sensor 17 MII_HVBAT_T_17
- Request
22 74 25 - Service 22
DID 7425 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery temperature, maximum MII_HVBAT_T_MAX
- Request
22 1E 0E - Service 22
DID 1E0E - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
HV battery voltage MII_HVBAT_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 1E 3B - Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x051C = 1308 → (1308 ÷ 4) = 327 V
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
Confirmed for 2020. In testing for 2019, 2021.
HV interlock detector voltage MII_HV_INTERLOCK_DET_V
- Request
22 74 B9 - Service 22
DID 74B9 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 3276)- Range
- 0 to 20.004 V
- Unit
- V
In testing for 2019 to 2021.
HV interlock source current MII_HV_INTERLOCK_SRC_I
- Request
22 74 BC - Service 22
DID 74BC - Module
7E5 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 mA
- Unit
- mA
In testing for 2019 to 2021.
HV interlock source voltage MII_HV_INTERLOCK_SRC_V
- Request
22 74 BA - Service 22
DID 74BA - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 3276)- Range
- 0 to 20.004 V
- Unit
- V
In testing for 2019 to 2021.
HV system isolation resistance, negative MII_HV_ISO_NEG_SYS
- Request
22 1E 19 - Service 22
DID 1E19 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2019 to 2021.
HV system isolation resistance, positive MII_HV_ISO_POS_SYS
- Request
22 1E 17 - Service 22
DID 1E17 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2019 to 2021.
Onboard electrical system current MII_AUX_I
- Request
22 16 17 - Service 22
DID 1617 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 A
- Unit
- A
In testing for 2019 to 2021.
Onboard electrical system power MII_AUX_PWR
- Request
22 10 77 - Service 22
DID 1077 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4)- Range
- 0 to 262140 W
- Unit
- W
In testing for 2019 to 2021.
Power electronics terminal 30 voltage MII_PE_KL30_V
- Request
22 46 5D - Service 22
DID 465D - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 V
- Unit
- V
In testing for 2019 to 2021.
Terminal 30 voltage MII_KL30_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 F4 42 - Service 22
DID F442 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x3068 = 12392 → (12392 ÷ 1000) = 12.392 V
- Formula
(val ÷ 1000)- Range
- 0 to 65 V
- Unit
- V
Confirmed for 2020. In testing for 2019, 2021.
Traction current reported by the battery management system MII_PE_BMS_HV_I
- Request
22 46 5F - Service 22
DID 465F - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2019 to 2021.
Traction voltage reported by the battery management system MII_PE_BMS_HV_V
- Request
22 46 6E - Service 22
DID 466E - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.