Battery parameters
The Škoda Rapid has 1,107 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
3V supply voltage SKODA_CHRGR_3V_SUPPLY
- Request
22 15 F7 - Service 22
DID 15F7 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 100 + 3.1)- Range
- 3.1 to 5.65 V
- Unit
- V
In testing for 2012 to 2023.
12V battery adapted capacity SKODA_AUX_BAT_CAP
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 Ah
- Unit
- Ah
In testing for 2012 to 2023.
12V battery aging by capacity SKODA_AUX_BAT_AGE_CAP
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
12V battery aging by power SKODA_AUX_BAT_AGE_POW
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
12V battery capacity SKODA_12V_BAT_CAP
- Request
22 2A 06 - Service 22
DID 2A06 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2012 to 2023.
12V battery current SKODA_AUX_BAT_C
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 47 of the reply, 32 bits. The value is signed.
- Formula
(val × 0.001)- Range
- -1000000 to 1000000 A
- Unit
- A
In testing for 2012 to 2023.
12V battery sensor temperature SKODA_AUX_BAT_T_S
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
12V battery soc SKODA_AUX_BAT_SOC
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
12V battery temperature SKODA_AUX_BAT_T
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
12V battery total charge SKODA_AUX_BAT_CHRG_TOT
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 96 to 127 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 10000000 Ah
- Unit
- Ah
In testing for 2012 to 2023.
12V battery total discharge SKODA_AUX_BAT_DSCH_TOT
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 128 to 159 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 10000000 Ah
- Unit
- Ah
In testing for 2012 to 2023.
12V battery voltage SKODA_AUX_BAT_V
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 4)- Range
- 0 to 69 V
- Unit
- V
In testing for 2012 to 2023.
AC charging SKODA_AC_CHARGING
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2012 to 2023.
All-wheel drive voltage SKODA_PQ35_HAL_V
- Request
22 2B E9 - Service 22
DID 2BE9 - Module
70F → 779 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2012 to 2023.
All-wheel-drive pump voltage SKODA_AWD_PMP_V
- Request
22 2B 0E - Service 22
DID 2B0E - Module
71D → 787 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.84)- Range
- -19.84 to 19.9999 V
- Unit
- V
In testing for 2012 to 2023.
Aux. hydraulic pump voltage SKODA_AUX_HYDRAULIC_PMP_V
- Request
22 51 A7 - Service 22
DID 51A7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2012 to 2023.
Battery acid stratification SKODA_BAT_ACID
- Request
22 2A 1D - Service 22
DID 2A1D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10 + 9)- Range
- 0 to 2559 %
- Unit
- %
In testing for 2012 to 2023.
Battery cell soc max, ID SKODA_HVBAT_CELL_SOC_MAX_ID
- Request
22 1E 2C - Service 22
DID 1E2C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
Battery cell soc min, ID SKODA_HVBAT_CELL_SOC_MIN_ID
- Request
22 1E 2D - Service 22
DID 1E2D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
Battery cell soc, maximum SKODA_HVBAT_CELL_SOC_MAX
- Request
22 1E 2C - Service 22
DID 1E2C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Battery cell soc, minimum SKODA_HVBAT_CELL_SOC_MIN
- Request
22 1E 2D - Service 22
DID 1E2D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Battery condition for display SKODA_BAT_COND_DISPLAY
- Request
22 2A 0D - Service 22
DID 2A0D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 %
- Unit
- %
In testing for 2012 to 2023.
Battery current SKODA_BAT_I
- Request
22 2A 09 - Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -2147483.648 to 2147483 A
- Unit
- A
In testing for 2012 to 2023.
Battery current SKODA_MQB_BAT_I
- Request
22 2A 09 - Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -2147483.648 to 2147483.647 A
- Unit
- A
In testing for 2012 to 2023.
Battery current filtered SKODA_BAT_CURRENT_FILTERED
- Request
22 2A 08 - Service 22
DID 2A08 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 1000 − 3000)- Range
- -3000 to 13777 A
- Unit
- A
In testing for 2012 to 2023.
Battery current limit, charging SKODA_HVBAT_I_LIM_CHG
- Request
22 1E 1B - Service 22
DID 1E1B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 2621.4 A
- Unit
- A
In testing for 2012 to 2023.
Battery current limit, discharging SKODA_HVBAT_I_LIM_DSCH
- Request
22 1E 1C - Service 22
DID 1E1C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 2621.4 A
- Unit
- A
In testing for 2012 to 2023.
Battery current, DC, alternate SKODA_HVBAT_I_DC_2
- Request
22 1E 3E - Service 22
DID 1E3E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100 − 1500)- Range
- -1500 to 42948172.95 A
- Unit
- A
In testing for 2012 to 2023.
Battery current, motor controller SKODA_HVBAT_I_ENG
- Request
22 03 5E - Service 22
DID 035E - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
In testing for 2012 to 2023.
Battery heater current SKODA_HVBAT_PTC_I
- Request
22 16 20 - Service 22
DID 1620 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 A
- Unit
- A
In testing for 2012 to 2023.
Battery heater temperature, #1 SKODA_HVBAT_PTC_T_1
- Request
22 16 23 - Service 22
DID 1623 - Module
FC00 → FE007B - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Battery heater temperature, #2 SKODA_HVBAT_PTC_T_2
- Request
22 16 24 - Service 22
DID 1624 - Module
FC00 → FE007B - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Battery heater voltage SKODA_HVBAT_PTC_V
- Request
22 16 21 - Service 22
DID 1621 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2012 to 2023.
Battery internal resistance SKODA_BAT_INT_R
- Request
22 2A 0E - Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 100)- Range
- 0 to 51
- Unit
- Raw value
In testing for 2012 to 2023.
Battery internal resistance SKODA_MQB_BAT_INT_RES
- Request
22 2A 0E - Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4
- Unit
- Raw value
In testing for 2012 to 2023.
Battery internal resistance SKODA_SSB_RES_INT
- Request
22 2A 0E - Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4
- Unit
- Number
In testing for 2012 to 2023.
Battery internal resistance, raw SKODA_BAT_INTERNAL_RES_RAW
- Request
22 2A 25 - Service 22
DID 2A25 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51
- Unit
- Raw value
In testing for 2012 to 2023.
Battery power reduction active SKODA_BMS_PWR_REDUCE_ACT
- Request
22 1E 0A - Service 22
DID 1E0A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
Battery temperature, inlet SKODA_HVBAT_T_IN
- Request
22 18 9D - Service 22
DID 189D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2012 to 2023.
Battery temperature, max SKODA_HVBAT_T_MAX_V2
- Request
22 1E 0E - Service 22
DID 1E0E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2012 to 2023.
Battery temperature, max sensor ID SKODA_HVBAT_T_MAX_ID
- Request
22 1E 0E - Service 22
DID 1E0E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
Battery temperature, min SKODA_HVBAT_T_MIN
- Request
22 1E 0F - Service 22
DID 1E0F - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2012 to 2023.
Battery temperature, min sensor ID SKODA_HVBAT_T_MIN_ID
- Request
22 1E 0F - Service 22
DID 1E0F - Module
FC00 → FE007B - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
Battery temperature, outlet SKODA_HVBAT_T_OUT
- Request
22 18 9D - Service 22
DID 189D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 2012 to 2023.
Battery total charge SKODA_BAT_TOT_CHG
- Request
22 2A 61 - Service 22
DID 2A61 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2012 to 2023.
Battery total discharge SKODA_BAT_TOT_DIS
- Request
22 2A 61 - Service 22
DID 2A61 - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2012 to 2023.
Battery voltage SKODA_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 5A - Service 22
DID 105A - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700 mV
- Unit
- mV
In testing for 2012 to 2023.
Battery voltage SKODA_BAT_V_2A07
Pelican can show this parameter as the starter battery voltage.
- Request
22 2A 07 - Service 22
DID 2A07 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 4)- Range
- 4 to 69.535 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage SKODA_BATTERY_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 5A - Service 22
DID 105A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage SKODA_BATTERY_V_V2
- Request
22 10 5A - Service 22
DID 105A - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 20)- Range
- -655360 to 655340 mV
- Unit
- mV
In testing for 2012 to 2023.
Battery voltage SKODA_MQB_BAT_V
- Request
22 2A 07 - Service 22
DID 2A07 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 4)- Range
- 4 to 69.535 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage variant SKODA_BAT_V_2
- Request
22 10 5E - Service 22
DID 105E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage variant SKODA_PQ35_BAT_V_2
- Request
22 10 5E - Service 22
DID 105E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 20 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage, after main switch SKODA_HVBAT_V_AFTER
- Request
22 1E 38 - Service 22
DID 1E38 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 312499785 ÷ 10000000000)- Range
- 0 to 2047.967 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage, before main switch SKODA_HVBAT_V_BEFORE
- Request
22 1E 36 - Service 22
DID 1E36 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 312499785 ÷ 10000000000)- Range
- 0 to 2047.967 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage, charging SKODA_HVBAT_V_CHG
- Request
22 1E 39 - Service 22
DID 1E39 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 312499785 ÷ 10000000000)- Range
- -1023.999 to 1023.967 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage, sum of all cells SKODA_HVBAT_V_CELLS_SUM
- Request
22 1E 3C - Service 22
DID 1E3C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val × 244140625 ÷ 1000000000)- Range
- -524288 to 524287.99 V
- Unit
- V
In testing for 2012 to 2023.
Battery voltage, traction mode SKODA_HVBAT_V_TRAC
- Request
22 46 75 - Service 22
DID 4675 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 V
- Unit
- V
In testing for 2012 to 2023.
Boost pressure SKODA_PQ35_CHG_P
- Request
22 10 57 - Service 22
DID 1057 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 bar
- Unit
- bar
In testing for 2012 to 2023.
Bypass valve high pressure turbine inlet, raw voltage SKODA_BYPASS_VLV_HIGH_P_V
- Request
22 3D 01 - Service 22
DID 3D01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 mV
- Unit
- mV
In testing for 2012 to 2023.
Calculated nitrogen oxide concentration behind turbocharger SKODA_MQB_NOX_CONC_BEHIND_TURBO
- Request
22 15 26 - Service 22
DID 1526 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 2012 to 2023.
Cell state of charge max, index SKODA_BMS_CELL_SOC_MAX_IDX
- Request
22 1E 2C - Service 22
DID 1E2C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
Cell state of charge max, value SKODA_BMS_CELL_SOC_MAX
- Request
22 1E 2C - Service 22
DID 1E2C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Cell state of charge min, index SKODA_BMS_CELL_SOC_MIN_IDX
- Request
22 1E 2D - Service 22
DID 1E2D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
Cell state of charge min, value SKODA_BMS_CELL_SOC_MIN
- Request
22 1E 2D - Service 22
DID 1E2D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Cell voltage max, index SKODA_BMS_CELL_V_MAX_IDX
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
Cell voltage max, value SKODA_BMS_CELL_V_MAX
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5535 V
- Unit
- V
In testing for 2012 to 2023.
Cell voltage min, index SKODA_BMS_CELL_V_MIN_IDX
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
Cell voltage min, value SKODA_BMS_CELL_V_MIN
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5535 V
- Unit
- V
In testing for 2012 to 2023.
Cell voltage sum SKODA_BMS_CELL_V_SUM
- Request
22 1E 3B - Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2012 to 2023.
Charge adjuster output stage SKODA_CHG_ADJUSTER_OUTPUT
- Request
22 11 81 - Service 22
DID 1181 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 %
- Unit
- %
In testing for 2012 to 2023.
Charge air cooler inlet, pressure sensor 1 bank 1 raw value SKODA_CHG_AIR_COOLER_INLET_P_1_1
- Request
22 44 5A - Service 22
DID 445A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107
- Unit
- Raw value
In testing for 2012 to 2023.
Charge air pressure SKODA_PQ35_CHG_AIR_P
- Request
22 22 11 - Service 22
DID 2211 - Module
714 → 77E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge air pressure actuator position digit.value SKODA_CHG_AIR_P_ACTUATOR
- Request
22 1B 11 - Service 22
DID 1B11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
Charge air pressure actuator, acknowledgment SKODA_CHG_AIR_P_ACTUATOR_V2
- Request
22 20 65 - Service 22
DID 2065 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2023.
Charge air pressure, actual value SKODA_CHG_AIR_P_ACT
- Request
22 10 57 - Service 22
DID 1057 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2012 to 2023.
Charge air pressure, actual value SKODA_CHG_AIR_P_ACT_V2
- Request
22 10 56 - Service 22
DID 1056 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2012 to 2023.
Charge air pressure, actual value SKODA_CHG_AIR_P_ACT_V3
- Request
22 1B 0E - Service 22
DID 1B0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119
- Unit
- Raw value
In testing for 2012 to 2023.
Charge air pressure, specified value SKODA_CHG_AIR_P_SPEC
- Request
22 FE 47 - Service 22
DID FE47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 kPa
- Unit
- kPa
In testing for 2012 to 2023.
Charge air pressure: actual SKODA_CHARGE_AIR_P_ACTUAL
- Request
22 20 2A - Service 22
DID 202A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.08)- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 2012 to 2023.
Charge air pressure: specified SKODA_CHARGE_AIR_P_SPECIFIED
- Request
22 20 29 - Service 22
DID 2029 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.08)- Range
- 0 to 5242.8
- Unit
- Raw value
In testing for 2012 to 2023.
Charge air temp at the turbocharger outlet, calculated SKODA_CHARGE_AIR_T_TUBROCHARGER_OUTLET_CALCULATED
- Request
22 17 98 - Service 22
DID 1798 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000 − 273.1)- Range
- -273.1 to 3003.6 °C
- Unit
- °C
In testing for 2012 to 2023.
Charge limit over-charge SKODA_CHG_LIM_OVER_CHG
- Request
22 13 56 - Service 22
DID 1356 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2012 to 2023.
Charge limit overcharge protection SKODA_PQ35_CHG_LIM_OVER
- Request
22 13 56 - Service 22
DID 1356 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 2012 to 2023.
Charge pressure actuator, actual position SKODA_CHG_P_ACTUATOR_ACT
- Request
22 39 A2 - Service 22
DID 39A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.012207)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure actuator, adaptation for lower stop SKODA_CHG_P_ACTUATOR_ADPT
- Request
22 39 A5 - Service 22
DID 39A5 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2012 to 2023.
Charge pressure actuator, adaptation for upper stop SKODA_CHG_P_ACTUATOR_ADPT_HI
- Request
22 39 A6 - Service 22
DID 39A6 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2012 to 2023.
Charge pressure actuator, maximum sensor voltage SKODA_CHG_P_ACTUATOR_MAX_V
- Request
22 3D 77 - Service 22
DID 3D77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 mV
- Unit
- mV
In testing for 2012 to 2023.
Charge pressure actuator, specified position SKODA_CHG_P_ACTUATOR_SPEC
- Request
22 39 A3 - Service 22
DID 39A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.012207)- Range
- 0 to 799 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure actuator, specified value SKODA_CHG_P_ACTUATOR_SPEC_7E0
- Request
22 39 A4 - Service 22
DID 39A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.012207)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure before throttle valve, calculated actual value SKODA_CHG_P_BEFORE_ACT
- Request
22 43 2B - Service 22
DID 432B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4)- Range
- -8192 to 8191
- Unit
- Raw value
In testing for 2012 to 2023.
Charge pressure control adaptation higher than max. threshold SKODA_CHG_P_CTRL_ADPT_MAX
- Request
22 29 3E - Service 22
DID 293E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure control adaptation lower than min. threshold SKODA_CHG_P_CTRL_ADPT_LO_MIN
- Request
22 29 3F - Service 22
DID 293F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure control specified value SKODA_CHG_P_CTRL_SPEC
- Request
22 11 08 - Service 22
DID 1108 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure control valve activation pulse duty factor SKODA_CHG_P_CTRL_VLV
- Request
22 3E A9 - Service 22
DID 3EA9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure control valve position, actual value SKODA_CHG_P_CTRL_VLV_POS_ACT
- Request
22 3E A7 - Service 22
DID 3EA7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure control valve position, target value SKODA_CHG_P_CTRL_VLV_POS_TGT
- Request
22 3E A6 - Service 22
DID 3EA6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Charge pressure control valve sensor voltage SKODA_CHG_P_CTRL_VLV_SENS_V
- Request
22 3E A8 - Service 22
DID 3EA8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 15259 ÷ 100000000)- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2012 to 2023.
Charge pressure control valve voltage, position closed SKODA_CHG_P_CTRL_VLV_V_POS
- Request
22 3E AB - Service 22
DID 3EAB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 15259 ÷ 100000000)- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2012 to 2023.
Charge pressure control valve voltage, position opened SKODA_CHG_P_CTRL_VLV_V_POS_OPENED
- Request
22 3E AC - Service 22
DID 3EAC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 15259 ÷ 100000000)- Range
- 0 to 9.9999 V
- Unit
- V
In testing for 2012 to 2023.
Charge pressure regulator, lower threshold adaptation SKODA_CHG_P_REGULATOR_LO
- Request
22 16 EC - Service 22
DID 16EC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2012 to 2023.
Charge pressure regulator, upper threshold adaptation SKODA_CHG_P_REGULATOR_HI
- Request
22 16 ED - Service 22
DID 16ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 mV
- Unit
- mV
In testing for 2012 to 2023.
Charge pressure sensor, unconditioned voltage SKODA_CHG_P_SENS_V
- Request
22 29 C7 - Service 22
DID 29C7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2023.
Charge voltage, max SKODA_MAXIMUM_CHARGE_V
- Request
22 51 71 - Service 22
DID 5171 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2012 to 2023.
Charger AC input current SKODA_CHG_AC_I
- Request
22 1D A8 - Service 22
DID 1DA8 - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2012 to 2023.
Charger AC input current setpoint SKODA_CHG_AC_I_SET
- Request
22 15 D3 - Service 22
DID 15D3 - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2012 to 2023.
Charger AC input voltage SKODA_CHG_AC_V
- Request
22 1D A9 - Service 22
DID 1DA9 - Module
744 - Every
30 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2012 to 2023.
Charger coolant temperature SKODA_CHRGR_COOLANT_T
- Request
22 15 E2 - Service 22
DID 15E2 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
Charger DC link voltage SKODA_CHG_LINK_V
- Request
22 15 DB - Service 22
DID 15DB - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2012 to 2023.
Charger DC to DC coil temperature SKODA_CHG_DCDC_COIL_T
- Request
22 15 DA - Service 22
DID 15DA - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
Charger DC to DC gate driver voltage SKODA_CHG_DCDC_GATE_V
- Request
22 15 DD - Service 22
DID 15DD - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2012 to 2023.
Charger DC to DC power line temperature SKODA_CHG_DCDC_LINE_T
- Request
22 15 EC - Service 22
DID 15EC - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
Charger output current SKODA_CHG_HV_I
- Request
22 42 37 - Service 22
DID 4237 - Module
744 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.749 A
- Unit
- A
In testing for 2012 to 2023.
Charger output current setpoint SKODA_CHG_HV_I_SET
- Request
22 42 38 - Service 22
DID 4238 - Module
744 - Every
30 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.749 A
- Unit
- A
In testing for 2012 to 2023.
Charger output voltage SKODA_CHG_OUT_V
- Request
22 1D A7 - Service 22
DID 1DA7 - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2012 to 2023.
Charger power factor coil temperature SKODA_CHG_PFC_COIL_T
- Request
22 15 D9 - Service 22
DID 15D9 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
Charger power factor gate driver voltage SKODA_CHG_PFC_GATE_V
- Request
22 15 DC - Service 22
DID 15DC - Module
744 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2012 to 2023.
Charger power loss SKODA_CHG_PWR_LOSS
- Request
22 15 E1 - Service 22
DID 15E1 - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20)- Range
- 0 to 5100 W
- Unit
- W
In testing for 2012 to 2023.
Charger temperature SKODA_CHG_T
- Request
22 15 D8 - Service 22
DID 15D8 - Module
744 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
Charging duration total SKODA_CHRGR_DUR_TOTAL
- Request
22 15 EE - Service 22
DID 15EE - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 min
- Unit
- min
In testing for 2012 to 2023.
Charging efficiency SKODA_CHG_EFFICIENCY
- Request
22 15 D6 - Service 22
DID 15D6 - Module
744 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 75)- Range
- 0 to 100.499 %
- Unit
- %
In testing for 2012 to 2023.
Charging, rapid? SKODA_RAPID_CHARGE_PORT
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2012 to 2023.
Control module temperature SKODA_HVBAT_ECU_T
- Request
22 16 22 - Service 22
DID 1622 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Control module voltage SKODA_VPWR
- Request
22 F4 42 - Service 22
DID F442 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65 V
- Unit
- V
In testing for 2012 to 2023.
Cooling puump power set point SKODA_BMS_COOL_PUMP_PWR_SP
- Request
22 19 2B - Service 22
DID 192B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2012 to 2023.
Current gear SKODA_DRIVE_MODE
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing
Bit 7 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STANDBY | Standby |
1 | DRIVING | Driving |
In testing for 2012 to 2023.
Cycle energy transformation SKODA_OBC_CYCLE_ENERGY
- Request
22 10 3E - Service 22
DID 103E - Module
744 → 7AE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kWh
- Unit
- kWh
In testing for 2012 to 2023.
Cylinder charge specified value SKODA_CYL_CHG_SPEC
- Request
22 43 2F - Service 22
DID 432F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2012 to 2023.
Cylinder charge, actual value SKODA_CYL_CHG_ACT
- Request
22 43 67 - Service 22
DID 4367 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2012 to 2023.
DC battery voltage SKODA_DC_BATTERY_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 1E 3B - Service 22
DID 1E3B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 V
- Unit
- V
In testing for 2012 to 2023.
DC link voltage SKODA_DC_LINK_V
- Request
22 3E 93 - Service 22
DID 3E93 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 V
- Unit
- V
In testing for 2012 to 2023.
DC link voltage reserve SKODA_DC_LINK_V_RESERVE
- Request
22 43 B9 - Service 22
DID 43B9 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 V
- Unit
- V
In testing for 2012 to 2023.
DC to DC converter circuit board temperature SKODA_DCDC_PCB_T
- Request
22 46 4E - Service 22
DID 464E - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
DC to DC converter high-voltage side voltage SKODA_DCDC_HV_V
- Request
22 15 87 - Service 22
DID 1587 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2012 to 2023.
DC to DC converter link voltage SKODA_DCDC_LINK_V
- Request
22 3E 72 - Service 22
DID 3E72 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2012 to 2023.
DC to DC converter power stage temperature SKODA_DCDC_PWR_T
- Request
22 46 4F - Service 22
DID 464F - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
DC to DC converter regulated output voltage SKODA_PE_DCDC_KL30_V
- Request
22 46 5C - Service 22
DID 465C - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 V
- Unit
- V
In testing for 2012 to 2023.
DC to DC converter temperature SKODA_PE_DCDC_T
- Request
22 3E B5 - Service 22
DID 3EB5 - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
DC to DC converter traction current SKODA_DCDC_HV_I
- Request
22 46 50 - Service 22
DID 4650 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 A
- Unit
- A
In testing for 2012 to 2023.
DC to DC converter traction voltage SKODA_PE_DCDC_HV_V
- Request
22 46 5E - Service 22
DID 465E - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2012 to 2023.
DC-DC converter coolant temperature SKODA_DCDC_T_COOL
- Request
22 43 B8 - Service 22
DID 43B8 - Module
FC00 → FE0076 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2012 to 2023.
DC-DC converter current, alternate SKODA_DCDC_I_ALT
- Request
22 46 5B - Service 22
DID 465B - Module
FC00 → FE00B9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 A
- Unit
- A
In testing for 2012 to 2023.
DC-DC converter, current SKODA_DCDC_I
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 A
- Unit
- A
In testing for 2012 to 2023.
DC-DC converter, low voltage SKODA_DCDC_V_LOW
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2012 to 2023.
DC-DC converter, reserved current SKODA_DCDC_I_RSV
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 A
- Unit
- A
In testing for 2012 to 2023.
DC-DC voltage SKODA_DC_DC_V
- Request
22 46 5D - Service 22
DID 465D - Module
FC00 → FE00B9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.9980469 V
- Unit
- V
In testing for 2012 to 2023.
Desired link voltage SKODA_DESIRED_LINK_V
- Request
22 3E ED - Service 22
DID 3EED - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 1000 V
- Unit
- V
In testing for 2012 to 2023.
Diesel particulate filter charge limit for field regeneration SKODA_DPF_CHG_LIM_FIELD
- Request
22 20 D9 - Service 22
DID 20D9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2012 to 2023.
Diesel particulate filter charge limit for service regeneration SKODA_DPF_CHG_LIM_SERVICE
- Request
22 20 DA - Service 22
DID 20DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2012 to 2023.
Diesel particulate filter charge limit over-charge SKODA_DPF_CHG_LIM_OVER_CHG
- Request
22 20 DB - Service 22
DID 20DB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327
- Unit
- Raw value
In testing for 2012 to 2023.
Diesel particulate filter heat voltage SKODA_DPF_HEAT_V
- Request
22 44 FA - Service 22
DID 44FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2012 to 2023.
Diesel particulate filter statistics current avg. torque gradient in charge cycle, nm/s SKODA_DPF_STATISTICS_S
- Request
22 40 0C - Service 22
DID 400C - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Number
In testing for 2012 to 2023.
Diesel particulate filter statistics, average drive cycle time during charge cycle SKODA_DPF_STATISTICS_AVG
- Request
22 40 33 - Service 22
DID 4033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 16)- Range
- 0 to 4080 s
- Unit
- s
In testing for 2012 to 2023.
Diesel particulate filter statistics, average RPM in charge cycle SKODA_DPF_STATISTICS_AVG_V2
- Request
22 40 0E - Service 22
DID 400E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 rpm
- Unit
- rpm
In testing for 2012 to 2023.
Diesel particulate filter statistics, average temperature. after DPF in charge cycle SKODA_DPF_STATISTICS_AVG_T
- Request
22 40 17 - Service 22
DID 4017 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2012 to 2023.
Diesel particulate filter statistics, avg drive cycle time during charge cycle SKODA_DPF_STATISTICS_AVG_DRIVE
- Request
22 40 33 - Service 22
DID 4033 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100)- Range
- 0 to 42949672 s
- Unit
- s
In testing for 2012 to 2023.
Diesel particulate filter statistics, calculated charging rate in charge cycle, g/km SKODA_DPF_STATISTICS_CALC_G
- Request
22 40 1D - Service 22
DID 401D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 100000000)- Range
- -3.99 to 3.99
- Unit
- Number
In testing for 2012 to 2023.
Diesel particulate filter statistics, current average speed in charge cycle SKODA_DPF_STATISTICS
- Request
22 40 0A - Service 22
DID 400A - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 km/h
- Unit
- km/h
In testing for 2012 to 2023.
Diesel particulate filter statistics, measured charging rate in charge cycle, g/km SKODA_DPF_STATISTICS_MEAS_G
- Request
22 40 1B - Service 22
DID 401B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 12207 ÷ 100000000)- Range
- -3.99 to 3.99
- Unit
- Number
In testing for 2012 to 2023.
Diesel particulate filter statistics, route in charge cycle SKODA_DPF_STATISTICS_ROUTE
- Request
22 40 31 - Service 22
DID 4031 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 8)- Range
- 0 to 2040 km
- Unit
- km
In testing for 2012 to 2023.
Diesel particulate filter, differential pressure sensor, voltage SKODA_DPF_DIFF_P_SENS_V
- Request
22 44 93 - Service 22
DID 4493 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2023.
Discharge voltage, min SKODA_MINIMUM_DISCHARGE_V
- Request
22 51 70 - Service 22
DID 5170 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2012 to 2023.
Ecall battery charge status SKODA_ECALL_BATTERY_CHARGE_STATUS
- Request
22 08 38 - Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100
- Unit
- Number
In testing for 2012 to 2023.
ECall battery status SKODA_ECALL_STATUS
- Request
22 08 38 - Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State |
|---|---|
1 | CRITICAL |
2 | NORMAL |
In testing for 2012 to 2023.
Electric machine high-voltage battery energy information SKODA_HIGH_V_EM_HVBAT
- Request
22 15 12 - Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2012 to 2023.
Electric motor battery energy SKODA_EM_HVBAT_E_INFO
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 3276.75 kWh
- Unit
- kWh
In testing for 2012 to 2023.
Emergency call battery critical status SKODA_ECALL_BAT_CRIT
- Request
22 08 38 - Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Emergency call battery level SKODA_ECALL_BAT_LVL
- Request
22 08 38 - Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Energy turnover total SKODA_CHRGR_E_TOTAL
- Request
22 15 EF - Service 22
DID 15EF - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 kWh
- Unit
- kWh
In testing for 2012 to 2023.
Estimated reserve range SKODA_RANGE_EST_CAN
- Request
22 2A B5 - Service 22
DID 2AB5 - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2012 to 2023.
Exhaust gas recirculation valve 1, B1, mass current: specified value SKODA_MQB_EGR_VALVE_1_B1_MASS_I_SPEC
- Request
22 18 13 - Service 22
DID 1813 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2012 to 2023.
Exhaust gas recirculation valve 2, B1, mass current: specified value SKODA_MQB_EGR_VALVE_2_B1_MASS_I_SPEC
- Request
22 18 14 - Service 22
DID 1814 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7
- Unit
- Raw value
In testing for 2012 to 2023.
Generator target voltage SKODA_MQB_GEN_TRG_V
- Request
22 2A 00 - Service 22
DID 2A00 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 10.6)- Range
- 10.6 to 36.1 V
- Unit
- V
In testing for 2012 to 2023.
Generator voltage, actual SKODA_GEN_V_ACT
- Request
22 4F 00 - Service 22
DID 4F00 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 10.6)- Range
- 0 to 36.1 V
- Unit
- V
In testing for 2012 to 2023.
High pressure exhaust gas recirculation actuator, actual unconditioned voltage SKODA_HIGH_P_EGR_ACTUATOR_ACT_V
- Request
22 11 A9 - Service 22
DID 11A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2012 to 2023.
High pressure turbocharger actuator, actual unconditioned voltage SKODA_HIGH_P_TURBOCHARGER_ACT_V
- Request
22 11 D0 - Service 22
DID 11D0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2012 to 2023.
High voltage battery energy information SKODA_HVBAT_ENERGY
- Request
22 15 12 - Service 22
DID 1512 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638 kWh
- Unit
- kWh
In testing for 2012 to 2023.
High voltage battery inlet temperature SKODA_HVBAT_INLET_T
- Request
22 18 9D - Service 22
DID 189D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2012 to 2023.
High voltage battery mode SKODA_HVBAT_MODE_0_STANDBY_1_2_3_4_5_6_7
- Request
22 74 48 - Service 22
DID 7448 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
High voltage battery outlet temperature SKODA_HVBAT_OUTLET_T
- Request
22 18 9D - Service 22
DID 189D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2012 to 2023.
High voltage battery total charge ah SKODA_HVBAT_TOT_CHG_AH
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 549.31642)- Range
- 0 to 7818749 Ah
- Unit
- Ah
In testing for 2012 to 2023.
High voltage battery total charge kwh SKODA_HVBAT_TOT_CHG_KWH
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
(val ÷ 8583.07212)- Range
- 0 to 500399 kWh
- Unit
- kWh
In testing for 2012 to 2023.
High voltage battery total discharge ah SKODA_HVBAT_TOT_DCHG_AH
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 549.31642)- Range
- 0 to 7818749 Ah
- Unit
- Ah
In testing for 2012 to 2023.
High voltage battery total discharge kwh SKODA_HVBAT_TOT_DCHG_KWH
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 96 to 127 of the reply, 32 bits.
- Formula
(val ÷ 8583.07212)- Range
- 0 to 500399 kWh
- Unit
- kWh
In testing for 2012 to 2023.
High voltage output SKODA_OBC_HIGH_V_OUTPUT
- Request
22 1D A7 - Service 22
DID 1DA7 - Module
744 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2012 to 2023.
High-voltage battery charge SKODA_HVBAT_SOC_V2
Pelican can show this parameter as the state of charge.
- Request
22 11 56 - Service 22
DID 1156 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV auxiliary current total SKODA_HVAUX_I
- Request
22 03 60 - Service 22
DID 0360 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2012 to 2023.
HV auxiliary power SKODA_HVAUX_PWR
- Request
22 03 64 - Service 22
DID 0364 - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 kW
- Unit
- kW
In testing for 2012 to 2023.
HV battery after contacts voltage SKODA_HVBAT_AFTER_CONTACTS_V
- Request
22 18 9B - Service 22
DID 189B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 1000)- Range
- -1000 to 31767.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery capacity SKODA_HVBAT_CAP
Total possible energy in the high voltage battery
- Request
22 2A B2 - Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1310770)- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2012 to 2023.
HV battery cell 1 voltage SKODA_HVBAT_CELL_1_V
- Request
22 1E 40 - Service 22
DID 1E40 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 2 voltage SKODA_HVBAT_CELL_2_V
- Request
22 1E 41 - Service 22
DID 1E41 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 3 voltage SKODA_HVBAT_CELL_3_V
- Request
22 1E 42 - Service 22
DID 1E42 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 4 voltage SKODA_HVBAT_CELL_4_V
- Request
22 1E 43 - Service 22
DID 1E43 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 5 voltage SKODA_HVBAT_CELL_5_V
- Request
22 1E 44 - Service 22
DID 1E44 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 6 voltage SKODA_HVBAT_CELL_6_V
- Request
22 1E 45 - Service 22
DID 1E45 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 7 voltage SKODA_HVBAT_CELL_7_V
- Request
22 1E 46 - Service 22
DID 1E46 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 8 voltage SKODA_HVBAT_CELL_8_V
- Request
22 1E 47 - Service 22
DID 1E47 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 9 voltage SKODA_HVBAT_CELL_9_V
- Request
22 1E 48 - Service 22
DID 1E48 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 10 voltage SKODA_HVBAT_CELL_10_V
- Request
22 1E 49 - Service 22
DID 1E49 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 11 voltage SKODA_HVBAT_CELL_11_V
- Request
22 1E 4A - Service 22
DID 1E4A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 12 voltage SKODA_HVBAT_CELL_12_V
- Request
22 1E 4B - Service 22
DID 1E4B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 13 voltage SKODA_HVBAT_CELL_13_V
- Request
22 1E 4C - Service 22
DID 1E4C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 14 voltage SKODA_HVBAT_CELL_14_V
- Request
22 1E 4D - Service 22
DID 1E4D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 15 voltage SKODA_HVBAT_CELL_15_V
- Request
22 1E 4E - Service 22
DID 1E4E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 16 voltage SKODA_HVBAT_CELL_16_V
- Request
22 1E 4F - Service 22
DID 1E4F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 17 voltage SKODA_HVBAT_CELL_17_V
- Request
22 1E 50 - Service 22
DID 1E50 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 18 voltage SKODA_HVBAT_CELL_18_V
- Request
22 1E 51 - Service 22
DID 1E51 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 19 voltage SKODA_HVBAT_CELL_19_V
- Request
22 1E 52 - Service 22
DID 1E52 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 20 voltage SKODA_HVBAT_CELL_20_V
- Request
22 1E 53 - Service 22
DID 1E53 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 21 voltage SKODA_HVBAT_CELL_21_V
- Request
22 1E 54 - Service 22
DID 1E54 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 22 voltage SKODA_HVBAT_CELL_22_V
- Request
22 1E 55 - Service 22
DID 1E55 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 23 voltage SKODA_HVBAT_CELL_23_V
- Request
22 1E 56 - Service 22
DID 1E56 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 24 voltage SKODA_HVBAT_CELL_24_V
- Request
22 1E 57 - Service 22
DID 1E57 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 25 voltage SKODA_HVBAT_CELL_25_V
- Request
22 1E 58 - Service 22
DID 1E58 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 26 voltage SKODA_HVBAT_CELL_26_V
- Request
22 1E 59 - Service 22
DID 1E59 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 27 voltage SKODA_HVBAT_CELL_27_V
- Request
22 1E 5A - Service 22
DID 1E5A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 28 voltage SKODA_HVBAT_CELL_28_V
- Request
22 1E 5B - Service 22
DID 1E5B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 29 voltage SKODA_HVBAT_CELL_29_V
- Request
22 1E 5C - Service 22
DID 1E5C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 30 voltage SKODA_HVBAT_CELL_30_V
- Request
22 1E 5D - Service 22
DID 1E5D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 31 voltage SKODA_HVBAT_CELL_31_V
- Request
22 1E 5E - Service 22
DID 1E5E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 32 voltage SKODA_HVBAT_CELL_32_V
- Request
22 1E 5F - Service 22
DID 1E5F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 33 voltage SKODA_HVBAT_CELL_33_V
- Request
22 1E 60 - Service 22
DID 1E60 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 34 voltage SKODA_HVBAT_CELL_34_V
- Request
22 1E 61 - Service 22
DID 1E61 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 35 voltage SKODA_HVBAT_CELL_35_V
- Request
22 1E 62 - Service 22
DID 1E62 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 36 voltage SKODA_HVBAT_CELL_36_V
- Request
22 1E 63 - Service 22
DID 1E63 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 37 voltage SKODA_HVBAT_CELL_37_V
- Request
22 1E 64 - Service 22
DID 1E64 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 38 voltage SKODA_HVBAT_CELL_38_V
- Request
22 1E 65 - Service 22
DID 1E65 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 39 voltage SKODA_HVBAT_CELL_39_V
- Request
22 1E 66 - Service 22
DID 1E66 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 40 voltage SKODA_HVBAT_CELL_40_V
- Request
22 1E 67 - Service 22
DID 1E67 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 41 voltage SKODA_HVBAT_CELL_41_V
- Request
22 1E 68 - Service 22
DID 1E68 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 42 voltage SKODA_HVBAT_CELL_42_V
- Request
22 1E 69 - Service 22
DID 1E69 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 43 voltage SKODA_HVBAT_CELL_43_V
- Request
22 1E 6A - Service 22
DID 1E6A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 44 voltage SKODA_HVBAT_CELL_44_V
- Request
22 1E 6B - Service 22
DID 1E6B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 45 voltage SKODA_HVBAT_CELL_45_V
- Request
22 1E 6C - Service 22
DID 1E6C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 46 voltage SKODA_HVBAT_CELL_46_V
- Request
22 1E 6D - Service 22
DID 1E6D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 47 voltage SKODA_HVBAT_CELL_47_V
- Request
22 1E 6E - Service 22
DID 1E6E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 48 voltage SKODA_HVBAT_CELL_48_V
- Request
22 1E 6F - Service 22
DID 1E6F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 49 voltage SKODA_HVBAT_CELL_49_V
- Request
22 1E 70 - Service 22
DID 1E70 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 50 voltage SKODA_HVBAT_CELL_50_V
- Request
22 1E 71 - Service 22
DID 1E71 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 51 voltage SKODA_HVBAT_CELL_51_V
- Request
22 1E 72 - Service 22
DID 1E72 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 52 voltage SKODA_HVBAT_CELL_52_V
- Request
22 1E 73 - Service 22
DID 1E73 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 53 voltage SKODA_HVBAT_CELL_53_V
- Request
22 1E 74 - Service 22
DID 1E74 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 54 voltage SKODA_HVBAT_CELL_54_V
- Request
22 1E 75 - Service 22
DID 1E75 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 55 voltage SKODA_HVBAT_CELL_55_V
- Request
22 1E 76 - Service 22
DID 1E76 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 56 voltage SKODA_HVBAT_CELL_56_V
- Request
22 1E 77 - Service 22
DID 1E77 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 57 voltage SKODA_HVBAT_CELL_57_V
- Request
22 1E 78 - Service 22
DID 1E78 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 58 voltage SKODA_HVBAT_CELL_58_V
- Request
22 1E 79 - Service 22
DID 1E79 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 59 voltage SKODA_HVBAT_CELL_59_V
- Request
22 1E 7A - Service 22
DID 1E7A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 60 voltage SKODA_HVBAT_CELL_60_V
- Request
22 1E 7B - Service 22
DID 1E7B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 61 voltage SKODA_HVBAT_CELL_61_V
- Request
22 1E 7C - Service 22
DID 1E7C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 62 voltage SKODA_HVBAT_CELL_62_V
- Request
22 1E 7D - Service 22
DID 1E7D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 63 voltage SKODA_HVBAT_CELL_63_V
- Request
22 1E 7E - Service 22
DID 1E7E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 64 voltage SKODA_HVBAT_CELL_64_V
- Request
22 1E 7F - Service 22
DID 1E7F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 65 voltage SKODA_HVBAT_CELL_65_V
- Request
22 1E 80 - Service 22
DID 1E80 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 66 voltage SKODA_HVBAT_CELL_66_V
- Request
22 1E 81 - Service 22
DID 1E81 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 67 voltage SKODA_HVBAT_CELL_67_V
- Request
22 1E 82 - Service 22
DID 1E82 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 68 voltage SKODA_HVBAT_CELL_68_V
- Request
22 1E 83 - Service 22
DID 1E83 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 69 voltage SKODA_HVBAT_CELL_69_V
- Request
22 1E 84 - Service 22
DID 1E84 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 70 voltage SKODA_HVBAT_CELL_70_V
- Request
22 1E 85 - Service 22
DID 1E85 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 71 voltage SKODA_HVBAT_CELL_71_V
- Request
22 1E 86 - Service 22
DID 1E86 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 72 voltage SKODA_HVBAT_CELL_72_V
- Request
22 1E 87 - Service 22
DID 1E87 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 73 voltage SKODA_HVBAT_CELL_73_V
- Request
22 1E 88 - Service 22
DID 1E88 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 74 voltage SKODA_HVBAT_CELL_74_V
- Request
22 1E 89 - Service 22
DID 1E89 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 75 voltage SKODA_HVBAT_CELL_75_V
- Request
22 1E 8A - Service 22
DID 1E8A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 76 voltage SKODA_HVBAT_CELL_76_V
- Request
22 1E 8B - Service 22
DID 1E8B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 77 voltage SKODA_HVBAT_CELL_77_V
- Request
22 1E 8C - Service 22
DID 1E8C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 78 voltage SKODA_HVBAT_CELL_78_V
- Request
22 1E 8D - Service 22
DID 1E8D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 79 voltage SKODA_HVBAT_CELL_79_V
- Request
22 1E 8E - Service 22
DID 1E8E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 80 voltage SKODA_HVBAT_CELL_80_V
- Request
22 1E 8F - Service 22
DID 1E8F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 81 voltage SKODA_HVBAT_CELL_81_V
- Request
22 1E 90 - Service 22
DID 1E90 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 82 voltage SKODA_HVBAT_CELL_82_V
- Request
22 1E 91 - Service 22
DID 1E91 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 83 voltage SKODA_HVBAT_CELL_83_V
- Request
22 1E 92 - Service 22
DID 1E92 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 84 voltage SKODA_HVBAT_CELL_84_V
- Request
22 1E 93 - Service 22
DID 1E93 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 85 voltage SKODA_HVBAT_CELL_85_V
- Request
22 1E 94 - Service 22
DID 1E94 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 86 voltage SKODA_HVBAT_CELL_86_V
- Request
22 1E 95 - Service 22
DID 1E95 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 87 voltage SKODA_HVBAT_CELL_87_V
- Request
22 1E 96 - Service 22
DID 1E96 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 88 voltage SKODA_HVBAT_CELL_88_V
- Request
22 1E 97 - Service 22
DID 1E97 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 89 voltage SKODA_HVBAT_CELL_89_V
- Request
22 1E 98 - Service 22
DID 1E98 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 90 voltage SKODA_HVBAT_CELL_90_V
- Request
22 1E 99 - Service 22
DID 1E99 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 91 voltage SKODA_HVBAT_CELL_91_V
- Request
22 1E 9A - Service 22
DID 1E9A - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 92 voltage SKODA_HVBAT_CELL_92_V
- Request
22 1E 9B - Service 22
DID 1E9B - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 93 voltage SKODA_HVBAT_CELL_93_V
- Request
22 1E 9C - Service 22
DID 1E9C - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 94 voltage SKODA_HVBAT_CELL_94_V
- Request
22 1E 9D - Service 22
DID 1E9D - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 95 voltage SKODA_HVBAT_CELL_95_V
- Request
22 1E 9E - Service 22
DID 1E9E - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 96 voltage SKODA_HVBAT_CELL_96_V
- Request
22 1E 9F - Service 22
DID 1E9F - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 97 voltage SKODA_HVBAT_CELL_97_V
- Request
22 1E A0 - Service 22
DID 1EA0 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 98 voltage SKODA_HVBAT_CELL_98_V
- Request
22 1E A1 - Service 22
DID 1EA1 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 99 voltage SKODA_HVBAT_CELL_99_V
- Request
22 1E A2 - Service 22
DID 1EA2 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 100 voltage SKODA_HVBAT_CELL_100_V
- Request
22 1E A3 - Service 22
DID 1EA3 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 101 voltage SKODA_HVBAT_CELL_101_V
- Request
22 1E A4 - Service 22
DID 1EA4 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell 102 voltage SKODA_HVBAT_CELL_102_V
- Request
22 1E A5 - Service 22
DID 1EA5 - Module
7E5 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage max, ID SKODA_HVBAT_CELL_V_MAX_ID
- Request
22 1E 33 - Service 22
DID 1E33 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
HV battery cell voltage min, ID SKODA_HVBAT_CELL_V_MIN_ID
- Request
22 1E 34 - Service 22
DID 1E34 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
HV battery cell voltage sum SKODA_HVBAT_CELL_SUM_V
- Request
22 1E 3C - Service 22
DID 1E3C - Module
7E5 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 4095.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, maximum SKODA_HVBAT_CELL_V_MAX
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, maximum SKODA_HVBAT_CELL_V_MAX_V2
- Request
22 1E 33 - Service 22
DID 1E33 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2441 ÷ 10000)- Range
- 0 to 15.997 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, minimum SKODA_HVBAT_CELL_V_MIN
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4096)- Range
- 0 to 15.999 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, minimum SKODA_HVBAT_CELL_V_MIN_V2
- Request
22 1E 34 - Service 22
DID 1E34 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2441 ÷ 10000)- Range
- 0 to 15.997 V
- Unit
- V
In testing for 2012 to 2023.
HV battery charge SKODA_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery charge (displayed) SKODA_HVBAT_SOC_DISP_V2
HV battery charge displayed on the dashboard
Pelican can show this parameter as the state of charge.
- Request
22 08 D2 - Service 22
DID 08D2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery charge current limit SKODA_HVBAT_CHG_I_LIM
- Request
22 1E 1B - Service 22
DID 1E1B - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2012 to 2023.
HV battery charge current limit, predicted SKODA_HVBAT_CHG_I_LIM_PRED
- Request
22 1E 1D - Service 22
DID 1E1D - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2012 to 2023.
HV battery charge throughput SKODA_HVBAT_AH_CHG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 549.31642)- Range
- 0 to 7818700 Ah
- Unit
- Ah
In testing for 2012 to 2023.
HV battery charge, displayed SKODA_HVBAT_SOC_DISP
Pelican can show this parameter as the state of charge.
- Request
22 11 64 - Service 22
DID 1164 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery charge, normalized SKODA_PE_SOC
- Request
22 F4 04 - Service 22
DID F404 - Module
7E6 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery coldest sensor SKODA_HVBAT_T_MIN_NO
- Request
22 1E 0F - Service 22
DID 1E0F - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery coolant pump control value SKODA_BMS_COOL_PUMP_CTL
- Request
22 80 EC - Service 22
DID 80EC - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2023.
HV battery current SKODA_BMS_I
Pelican can show this parameter as the traction battery current.
- Request
22 18 02 - Service 22
DID 1802 - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2.56 − 1500)- Range
- -1500 to 166269 A
- Unit
- A
In testing for 2012 to 2023.
HV battery current SKODA_HVBAT_CURRENT
- Request
22 1E 3D - Service 22
DID 1E3D - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 511)- Range
- -200 to 200 A
- Unit
- A
In testing for 2012 to 2023.
HV battery current SKODA_HVBAT_I
Pelican can show this parameter as the traction battery current.
- Request
22 1E 3D - Service 22
DID 1E3D - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 511)- Range
- -200 to 200 A
- Unit
- A
In testing for 2012 to 2023.
HV battery discharge current limit SKODA_HVBAT_DISCHG_I_LIM
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2012 to 2023.
HV battery discharge current limit, predicted SKODA_HVBAT_DISCHG_I_LIM_PRED
- Request
22 1E 1E - Service 22
DID 1E1E - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2012 to 2023.
HV battery discharge throughput SKODA_HVBAT_AH_DISCHG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 549.31642)- Range
- -3909350 to 3909350 Ah
- Unit
- Ah
In testing for 2012 to 2023.
HV battery energy SKODA_HVBAT_KWH
Energy stored in the high voltage battery
- Request
22 2A B8 - Service 22
DID 2AB8 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1310770)- Range
- 0 to 3276 kWh
- Unit
- kWh
In testing for 2012 to 2023.
HV battery energy SKODA_HVBAT_KWH_V2
Energy stored in the high voltage battery
Pelican can show this parameter as the traction battery capacity.
- Request
22 49 65 - Service 22
DID 4965 - Module
744 → 7AE - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276.75 kWh
- Unit
- kWh
In testing for 2012 to 2023.
HV battery energy charged SKODA_HVBAT_KWH_CHG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
(val ÷ 8583.07212)- Range
- 0 to 500300 kWh
- Unit
- kWh
In testing for 2012 to 2023.
HV battery energy content SKODA_HVBAT_E_CONTENT
Energy stored in the high voltage battery
- Request
22 2A B8 - Service 22
DID 2AB8 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 1000)- Range
- 0 to 1638.37 kWh
- Unit
- kWh
In testing for 2012 to 2023.
HV battery energy discharged SKODA_HVBAT_KWH_DISCHG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 96 to 127 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 8583.07212)- Range
- -250199.883 to 250199.883 kWh
- Unit
- kWh
In testing for 2012 to 2023.
HV battery health SKODA_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 51 E0 - Service 22
DID 51E0 - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.127 − 1798.574)- Range
- -1798.574 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery highest cell SKODA_HVBAT_CELL_V_MAX_NO
- Request
22 1E 33 - Service 22
DID 1E33 - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery hottest sensor SKODA_HVBAT_T_MAX_NO
- Request
22 1E 0E - Service 22
DID 1E0E - Module
7E5 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery isolation resistance, negative SKODA_HVBAT_ISO_NEG
- Request
22 1E 1A - Service 22
DID 1E1A - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2012 to 2023.
HV battery isolation resistance, positive SKODA_HVBAT_ISO_POS
- Request
22 1E 18 - Service 22
DID 1E18 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2012 to 2023.
HV battery lowest cell SKODA_HVBAT_CELL_V_MIN_NO
- Request
22 1E 34 - Service 22
DID 1E34 - Module
7E5 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery maximum energy, raw count SKODA_HVBAT_E_MAX_RAW
- Request
22 2A B2 - Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
HV battery maximum power SKODA_HVBAT_PWR_MAX
- Request
22 15 02 - Service 22
DID 1502 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4)- Range
- 0 to 262140 W
- Unit
- W
In testing for 2012 to 2023.
HV battery module temperature, #1 SKODA_HVBAT_MOD_T_1
- Request
22 1E AE - Service 22
DID 1EAE - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #2 SKODA_HVBAT_MOD_T_2
- Request
22 1E AF - Service 22
DID 1EAF - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #3 SKODA_HVBAT_MOD_T_3
- Request
22 1E B0 - Service 22
DID 1EB0 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #4 SKODA_HVBAT_MOD_T_4
- Request
22 1E B1 - Service 22
DID 1EB1 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #17 SKODA_HVBAT_MOD_T_17
- Request
22 74 25 - Service 22
DID 7425 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #18 SKODA_HVBAT_MOD_T_18
- Request
22 74 26 - Service 22
DID 7426 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #19 SKODA_HVBAT_MOD_T_19
- Request
22 74 27 - Service 22
DID 7427 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #20 SKODA_HVBAT_MOD_T_20
- Request
22 74 28 - Service 22
DID 7428 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #21 SKODA_HVBAT_MOD_T_21
- Request
22 74 29 - Service 22
DID 7429 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #22 SKODA_HVBAT_MOD_T_22
- Request
22 74 2A - Service 22
DID 742A - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #23 SKODA_HVBAT_MOD_T_23
- Request
22 74 2B - Service 22
DID 742B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #24 SKODA_HVBAT_MOD_T_24
- Request
22 74 2C - Service 22
DID 742C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery negative voltage before the contactors SKODA_HVBAT_NEG_V_PRE
- Request
22 1E 35 - Service 22
DID 1E35 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 V
- Unit
- V
In testing for 2012 to 2023.
HV battery positive voltage after the charging contactors SKODA_HVBAT_POS_V_POST_CHG
- Request
22 1E 39 - Service 22
DID 1E39 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 V
- Unit
- V
In testing for 2012 to 2023.
HV battery positive voltage before the contactors SKODA_HVBAT_POS_V_PRE
- Request
22 1E 36 - Service 22
DID 1E36 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2012 to 2023.
HV battery power SKODA_HVBAT_PWR
- Request
22 14 85 - Service 22
DID 1485 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 kW
- Unit
- kW
In testing for 2012 to 2023.
HV battery relative temperature SKODA_HVBAT_T_REL
- Request
22 14 9B - Service 22
DID 149B - Module
7E0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2012 to 2023.
HV battery remaining charge SKODA_HVBAT_REMAINING
- Request
22 F4 5B - Service 22
DID F45B - Module
7E0 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery state of charge SKODA_BMS_SOC
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery state of charge display SKODA_CHRGR_SOC_DISP
- Request
22 1D D0 - Service 22
DID 1DD0 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery state of charge, hd SKODA_BMS_SOC_HIRES
- Request
22 F4 5B - Service 22
DID F45B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery temperature SKODA_HVBAT_T
- Request
22 2A 0B - Service 22
DID 2A0B - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature load SKODA_HVBAT_T_LOAD
- Request
22 11 65 - Service 22
DID 1165 - Module
7E0 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 %
- Unit
- %
In testing for 2012 to 2023.
HV battery temperature sensor 1 SKODA_HVBAT_T_1
- Request
22 1E AE - Service 22
DID 1EAE - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 2 SKODA_HVBAT_T_2
- Request
22 1E AF - Service 22
DID 1EAF - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 3 SKODA_HVBAT_T_3
- Request
22 1E B0 - Service 22
DID 1EB0 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 4 SKODA_HVBAT_T_4
- Request
22 1E B1 - Service 22
DID 1EB1 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 5 SKODA_HVBAT_T_5
- Request
22 1E B2 - Service 22
DID 1EB2 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 6 SKODA_HVBAT_T_6
- Request
22 1E B3 - Service 22
DID 1EB3 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 7 SKODA_HVBAT_T_7
- Request
22 1E B4 - Service 22
DID 1EB4 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 8 SKODA_HVBAT_T_8
- Request
22 1E B5 - Service 22
DID 1EB5 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 9 SKODA_HVBAT_T_9
- Request
22 1E B6 - Service 22
DID 1EB6 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 10 SKODA_HVBAT_T_10
- Request
22 1E B7 - Service 22
DID 1EB7 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 11 SKODA_HVBAT_T_11
- Request
22 1E B8 - Service 22
DID 1EB8 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 12 SKODA_HVBAT_T_12
- Request
22 1E B9 - Service 22
DID 1EB9 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 13 SKODA_HVBAT_T_13
- Request
22 1E BA - Service 22
DID 1EBA - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 15 SKODA_HVBAT_T_15
- Request
22 1E BC - Service 22
DID 1EBC - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 16 SKODA_HVBAT_T_16
- Request
22 1E BD - Service 22
DID 1EBD - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature sensor 17 SKODA_HVBAT_T_17
- Request
22 74 25 - Service 22
DID 7425 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature, average SKODA_BMS_T_AVG
- Request
22 1E 10 - Service 22
DID 1E10 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature, maximum SKODA_BMS_T_MAX
- Request
22 1E 0E - Service 22
DID 1E0E - Module
7E5 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature, maximum SKODA_HVBAT_T_MAX
- Request
22 1E 0E - Service 22
DID 1E0E - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature, maximum (cell #) SKODA_BMS_T_MAX_CELL
- Request
22 1E 0E - Service 22
DID 1E0E - Module
7E5 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery temperature, minimum SKODA_BMS_T_MIN
- Request
22 1E 0F - Service 22
DID 1E0F - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery temperature, minimum (cell #) SKODA_BMS_T_MIN_CELL
- Request
22 1E 0F - Service 22
DID 1E0F - Module
7E5 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery total kilowatt hours of discharge SKODA_HVBAT_TOT_KWH_DCHRG
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
3600 s - Testing
Bits 96 to 127 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 8583.07212)- Range
- -250199 to 250199 kWh
- Unit
- kWh
In testing for 2012 to 2023.
HV battery voltage SKODA_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 1E 3B - Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2012 to 2023.
HV battery voltage SKODA_HVBAT_VOLT
Pelican can show this parameter as the traction battery voltage.
- Request
22 18 01 - Service 22
DID 1801 - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2012 to 2023.
HV battery voltage SKODA_HVBAT_VOLTS
- Request
22 1E 3B - Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2012 to 2023.
HV battery voltage, measurement 2 SKODA_HVBAT_V_180A
Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.
- Request
22 18 0A - Service 22
DID 180A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2012 to 2023.
HV battery voltage, measurement 3 SKODA_HVBAT_V_180B
Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.
- Request
22 18 0B - Service 22
DID 180B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2012 to 2023.
HV battery voltage, measurement 4 SKODA_HVBAT_V_1818
Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.
- Request
22 18 18 - Service 22
DID 1818 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2012 to 2023.
HV battery voltage, measurement 5 SKODA_HVBAT_V_181B
Reads within 1 V of the pack voltage on 1801; which point of the pack it measures is not known.
- Request
22 18 1B - Service 22
DID 181B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2012 to 2023.
HV battery, max energy SKODA_HVBAT_E_MAX
- Request
22 2A B2 - Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 50)- Range
- 0 to 3276750 W
- Unit
- W
In testing for 2012 to 2023.
HV battery: circulation pump flow SKODA_CIRC_PUMP_FLOW
- Request
22 74 3B - Service 22
DID 743B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV booster, commanded current SKODA_CHRGR_BOOST_CMD_I
- Request
22 15 5A - Service 22
DID 155A - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 A
- Unit
- A
In testing for 2012 to 2023.
HV booster, commanded voltage SKODA_CHRGR_BOOST_CMD_V
- Request
22 15 59 - Service 22
DID 1559 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 V
- Unit
- V
In testing for 2012 to 2023.
HV booster, HV highside current SKODA_CHRGR_BOOST_HI_I
- Request
22 15 53 - Service 22
DID 1553 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 A
- Unit
- A
In testing for 2012 to 2023.
HV booster, HV highside voltage SKODA_CHRGR_BOOST_HI_V
- Request
22 15 54 - Service 22
DID 1554 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 V
- Unit
- V
In testing for 2012 to 2023.
HV booster, HV lowside current SKODA_CHRGR_BOOST_LO_I
- Request
22 15 57 - Service 22
DID 1557 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 A
- Unit
- A
In testing for 2012 to 2023.
HV booster, HV lowside voltage SKODA_CHRGR_BOOST_LO_V
- Request
22 15 58 - Service 22
DID 1558 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 V
- Unit
- V
In testing for 2012 to 2023.
HV interlock detector voltage SKODA_HV_INTERLOCK_DET_V
- Request
22 74 B9 - Service 22
DID 74B9 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 3276)- Range
- 0 to 20.004 V
- Unit
- V
In testing for 2012 to 2023.
HV interlock source current SKODA_HV_INTERLOCK_SRC_I
- Request
22 74 BC - Service 22
DID 74BC - Module
7E5 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 mA
- Unit
- mA
In testing for 2012 to 2023.
HV interlock source voltage SKODA_HV_INTERLOCK_SRC_V
- Request
22 74 BA - Service 22
DID 74BA - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 3276)- Range
- 0 to 20.004 V
- Unit
- V
In testing for 2012 to 2023.
HV system isolation resistance, negative SKODA_HV_ISO_NEG_SYS
- Request
22 1E 19 - Service 22
DID 1E19 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2012 to 2023.
HV system isolation resistance, positive SKODA_HV_ISO_POS_SYS
- Request
22 1E 17 - Service 22
DID 1E17 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kΩ
- Unit
- kΩ
In testing for 2012 to 2023.
Ignition angle current cylinder SKODA_IGN_ANG_CYL
- Request
22 13 7A - Service 22
DID 137A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.375 − 35.625)- Range
- -35.625 to 60 N·m
- Unit
- N·m
In testing for 2012 to 2023.
Knock sensor voltage, cylinder 1 SKODA_KNOCK_SENS_V_CYL_1_V2
- Request
22 11 26 - Service 22
DID 1126 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 21333 ÷ 4369000)- Range
- 0 to 319 V
- Unit
- V
In testing for 2012 to 2023.
Knock sensor voltage, cylinder 3 SKODA_KNOCK_SENS_V_CYL_3_V2
- Request
22 11 27 - Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 21333 ÷ 4369000)- Range
- 0 to 319 V
- Unit
- V
In testing for 2012 to 2023.
Knock sensor voltage:, cylinder 1 SKODA_KNOCK_SENS_V_CYL_1
- Request
22 13 F8 - Service 22
DID 13F8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2012 to 2023.
Knock sensor voltage:, cylinder 2 SKODA_KNOCK_SENS_V_CYL_2
- Request
22 13 FC - Service 22
DID 13FC - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2012 to 2023.
Knock sensor voltage:, cylinder 3 SKODA_KNOCK_SENS_V_CYL_3
- Request
22 13 FA - Service 22
DID 13FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2012 to 2023.
Knock sensor voltage:, cylinder 4 SKODA_KNOCK_SENS_V_CYL_4
- Request
22 13 F9 - Service 22
DID 13F9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2012 to 2023.
Knock sensor voltage:, cylinder 5 SKODA_KNOCK_SENS_V_CYL_5
- Request
22 13 FD - Service 22
DID 13FD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2012 to 2023.
Knock sensor voltage:, cylinder 6 SKODA_KNOCK_SENS_V_CYL_6
- Request
22 13 FB - Service 22
DID 13FB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000076294)- Range
- 0 to 4.99 V
- Unit
- V
In testing for 2012 to 2023.
Knock sensors average voltage bank 1, variant 2 SKODA_KNOCK_SENSORS_AVG_V_1_2
- Request
22 4E 70 - Service 22
DID 4E70 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2023.
Maximum charge current SKODA_MAX_CHA_CUR_2
- Request
22 11 59 - Service 22
DID 1159 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3200 to 3200 A
- Unit
- A
In testing for 2012 to 2023.
Maximum charge power SKODA_CHRGR_CHG_PWR_MAX
- Request
22 1D D3 - Service 22
DID 1DD3 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2012 to 2023.
Maximum charge voltage SKODA_BMS_V_CHG_MAX
- Request
22 51 71 - Service 22
DID 5171 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2012 to 2023.
Maximum charging power SKODA_CHRGR_PWR_MAX
- Request
22 15 D5 - Service 22
DID 15D5 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2012 to 2023.
Maximum discharge current SKODA_MAX_DCHA_CUR_2
- Request
22 11 58 - Service 22
DID 1158 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3200 to 3200 A
- Unit
- A
In testing for 2012 to 2023.
Maximum dynamic charge current limit SKODA_BMS_I_CHG_LIM_DYN
- Request
22 1E 1B - Service 22
DID 1E1B - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2012 to 2023.
Maximum dynamic discharge current limit SKODA_BMS_I_DCHG_LIM_DYN
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2012 to 2023.
Maximum predicted charge current limit SKODA_BMS_I_CHG_LIM_PRED
- Request
22 1E 1D - Service 22
DID 1E1D - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2012 to 2023.
Maximum predicted discharge current limit SKODA_BMS_I_DCHG_LIM_PRED
- Request
22 1E 1E - Service 22
DID 1E1E - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2012 to 2023.
Minimum discharge voltage SKODA_BMS_V_DCHG_MIN
- Request
22 51 70 - Service 22
DID 5170 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2012 to 2023.
Minimum dynamic charge voltage SKODA_BMS_V_CHG_DYN_MIN
- Request
22 51 74 - Service 22
DID 5174 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2012 to 2023.
Minimum dynamic discharge voltage SKODA_BMS_V_DCHG_DYN_MIN
- Request
22 51 75 - Service 22
DID 5175 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2012 to 2023.
Minimum predicted charge voltage SKODA_BMS_V_CHG_PRED_MIN
- Request
22 51 72 - Service 22
DID 5172 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2012 to 2023.
Minimum predicted discharge voltage SKODA_BMS_V_DCHG_PRED_MIN
- Request
22 51 73 - Service 22
DID 5173 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2012 to 2023.
Non-vehicle energy requirement SKODA_NV_ENERGY_REQUIREMENT
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2012 to 2023.
Nox sulfur charge SKODA_NOX_SULFUR_CHG
- Request
22 43 66 - Service 22
DID 4366 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 2012 to 2023.
On-board charger, hv/dc current SKODA_OBC_HVDC_C
- Request
22 10 3D - Service 22
DID 103D - Module
744 → 7AE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2012 to 2023.
Onboard electrical system current SKODA_AUX_I
- Request
22 16 17 - Service 22
DID 1617 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 A
- Unit
- A
In testing for 2012 to 2023.
Onboard electrical system power SKODA_AUX_PWR
- Request
22 10 77 - Service 22
DID 1077 - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4)- Range
- 0 to 262140 W
- Unit
- W
In testing for 2012 to 2023.
Particle sensor, heat voltage SKODA_PARTICLE_SENS_HEAT_V
- Request
22 44 FA - Service 22
DID 44FA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 V
- Unit
- V
In testing for 2012 to 2023.
Power efficiency SKODA_CHRGR_EFFICIENCY
- Request
22 15 D6 - Service 22
DID 15D6 - Module
744 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 75)- Range
- 75 to 100.5 A
- Unit
- A
In testing for 2012 to 2023.
Power electronics terminal 30 voltage SKODA_PE_KL30_V
- Request
22 46 5D - Service 22
DID 465D - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 V
- Unit
- V
In testing for 2012 to 2023.
Power loss battery charger SKODA_CHRGR_PWR_LOSS
- Request
22 15 E1 - Service 22
DID 15E1 - Module
744 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20)- Range
- 0 to 5100
- Unit
- Raw value
In testing for 2012 to 2023.
PRX voltage charging connector b SKODA_CHRGR_PRX_V_CONN_B
- Request
22 15 29 - Service 22
DID 1529 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2012 to 2023.
Rail 1 energy transformation SKODA_CHRGR_RAIL1_E
- Request
22 15 07 - Service 22
DID 1507 - Module
744 → 7AE - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
In testing for 2012 to 2023.
Rail 2 energy transformation SKODA_CHRGR_RAIL2_E
- Request
22 15 07 - Service 22
DID 1507 - Module
744 → 7AE - Every
1 s - Testing
Bits 24 to 47 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
In testing for 2012 to 2023.
Rail 3 energy transformation SKODA_CHRGR_RAIL3_E
- Request
22 15 07 - Service 22
DID 1507 - Module
744 → 7AE - Every
1 s - Testing
Bits 48 to 71 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 kWh
- Unit
- kWh
In testing for 2012 to 2023.
Service regeneration current duration SKODA_PQ35_SRV_REGEN_DUR
- Request
22 11 64 - Service 22
DID 1164 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val × 0.0001666667)- Range
- 0 to 715827 min
- Unit
- min
In testing for 2012 to 2023.
Service regeneration value, two-byte reply, raw count SKODA_SRV_REGEN_VALUE_2012
- Request
22 11 64 - Service 22
DID 1164 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2023.
Start/stop battery charge SKODA_SSB_AH
- Request
22 2A 0F - Service 22
DID 2A0F - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2012 to 2023.
Start/stop battery current SKODA_SSB_C
- Request
22 2A 09 - Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -2147483 to 2147483 A
- Unit
- A
In testing for 2012 to 2023.
Start/stop battery current SKODA_SSB_C_32
- Request
22 2A 09 - Service 22
DID 2A09 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -1000 to 1000 A
- Unit
- A
In testing for 2012 to 2023.
Start/stop battery resistance SKODA_SSB_R
- Request
22 2A 0E - Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 10)- Range
- 0 to 51 mΩ
- Unit
- mΩ
In testing for 2012 to 2023.
Start/stop battery sensor temperature SKODA_SSB_SENSOR_T
- Request
22 2A 0A - Service 22
DID 2A0A - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
Start/stop battery sensor temperature SKODA_SSB_T
- Request
22 2A 0B - Service 22
DID 2A0B - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2023.
Start/stop battery state of charge SKODA_SSB_SOC
- Request
22 2A 0C - Service 22
DID 2A0C - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Start/stop battery target voltage SKODA_SSB_VT
- Request
22 2A 00 - Service 22
DID 2A00 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 10.6)- Range
- 0 to 36.1 V
- Unit
- V
In testing for 2012 to 2023.
Start/stop battery total charge SKODA_SSB_TOTAL_CHARGE
- Request
22 2A 61 - Service 22
DID 2A61 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 Ah
- Unit
- Ah
In testing for 2012 to 2023.
Start/stop battery total discharge SKODA_SSB_TOTAL_DISCHARGE
- Request
22 2A 61 - Service 22
DID 2A61 - Module
710 → 77A - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 Ah
- Unit
- Ah
In testing for 2012 to 2023.
Start/stop battery voltage SKODA_SSB_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 2A 07 - Service 22
DID 2A07 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 4)- Range
- 4 to 69.53 V
- Unit
- V
In testing for 2012 to 2023.
Start/stop battery voltage, at rest SKODA_SSB_V_REST
- Request
22 2A 10 - Service 22
DID 2A10 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 + 9)- Range
- 9 to 34.5 V
- Unit
- V
In testing for 2012 to 2023.
State of charge SKODA_SOC
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
FC00 → FE007B - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 250)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
State of charge SKODA_SOC_FC00
Pelican can show this parameter as the state of charge.
- Request
22 3D EF - Service 22
DID 3DEF - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
State of charge SKODA_SOC_V2
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
FC00 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 250)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
State of charge SKODA_SOC_V3
- Request
22 3D EF - Service 22
DID 3DEF - Module
FC00 → FE0076 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
State of charge, display SKODA_SOC_DISP
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
FC00 → FE007B - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20.4 ÷ 46 − 6.4)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
Temperature sensor for engine temperature management voltage SKODA_T_SENS_ENG_T_V
- Request
22 40 E4 - Service 22
DID 40E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2023.
Temperature sensor, socket a SKODA_OBC_T_A
- Request
22 1D DA - Service 22
DID 1DDA - Module
744 → 7AE - Every
5 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10 − 55)- Range
- -55 to 6498.5 °C
- Unit
- °C
In testing for 2012 to 2023.
Temperature, battery SKODA_BATTERY_T
- Request
22 2A 0B - Service 22
DID 2A0B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2012 to 2023.
Terminal 30 voltage SKODA_KL30_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 F4 42 - Service 22
DID F442 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65 V
- Unit
- V
In testing for 2012 to 2023.
Traction current reported by the battery management system SKODA_PE_BMS_HV_I
- Request
22 46 5F - Service 22
DID 465F - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2012 to 2023.
Traction voltage reported by the battery management system SKODA_PE_BMS_HV_V
- Request
22 46 6E - Service 22
DID 466E - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2012 to 2023.
Turbocharger inlet pressure corrected value SKODA_TURBOCHARGER_INLET_P
- Request
22 11 D4 - Service 22
DID 11D4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 5119.9218
- Unit
- Raw value
In testing for 2012 to 2023.
Voltage proximity, socket a SKODA_OBC_V_PROX_A
- Request
22 15 25 - Service 22
DID 1525 - Module
744 → 7AE - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2012 to 2023.
Battery › Cells
HV battery cell voltage, #1 SKODA_HVBAT_CELL_V_001
- Request
22 1E 40 - Service 22
DID 1E40 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #2 SKODA_HVBAT_CELL_V_002
- Request
22 1E 41 - Service 22
DID 1E41 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #3 SKODA_HVBAT_CELL_V_003
- Request
22 1E 42 - Service 22
DID 1E42 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #4 SKODA_HVBAT_CELL_V_004
- Request
22 1E 43 - Service 22
DID 1E43 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #5 SKODA_HVBAT_CELL_V_005
- Request
22 1E 44 - Service 22
DID 1E44 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #6 SKODA_HVBAT_CELL_V_006
- Request
22 1E 45 - Service 22
DID 1E45 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #7 SKODA_HVBAT_CELL_V_007
- Request
22 1E 46 - Service 22
DID 1E46 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #8 SKODA_HVBAT_CELL_V_008
- Request
22 1E 47 - Service 22
DID 1E47 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #9 SKODA_HVBAT_CELL_V_009
- Request
22 1E 48 - Service 22
DID 1E48 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #10 SKODA_HVBAT_CELL_V_010
- Request
22 1E 49 - Service 22
DID 1E49 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #11 SKODA_HVBAT_CELL_V_011
- Request
22 1E 4A - Service 22
DID 1E4A - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #12 SKODA_HVBAT_CELL_V_012
- Request
22 1E 4B - Service 22
DID 1E4B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #13 SKODA_HVBAT_CELL_V_013
- Request
22 1E 4C - Service 22
DID 1E4C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #14 SKODA_HVBAT_CELL_V_014
- Request
22 1E 4D - Service 22
DID 1E4D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #15 SKODA_HVBAT_CELL_V_015
- Request
22 1E 4E - Service 22
DID 1E4E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #16 SKODA_HVBAT_CELL_V_016
- Request
22 1E 4F - Service 22
DID 1E4F - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #17 SKODA_HVBAT_CELL_V_017
- Request
22 1E 50 - Service 22
DID 1E50 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #18 SKODA_HVBAT_CELL_V_018
- Request
22 1E 51 - Service 22
DID 1E51 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #19 SKODA_HVBAT_CELL_V_019
- Request
22 1E 52 - Service 22
DID 1E52 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #20 SKODA_HVBAT_CELL_V_020
- Request
22 1E 53 - Service 22
DID 1E53 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #21 SKODA_HVBAT_CELL_V_021
- Request
22 1E 54 - Service 22
DID 1E54 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #22 SKODA_HVBAT_CELL_V_022
- Request
22 1E 55 - Service 22
DID 1E55 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #23 SKODA_HVBAT_CELL_V_023
- Request
22 1E 56 - Service 22
DID 1E56 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #24 SKODA_HVBAT_CELL_V_024
- Request
22 1E 57 - Service 22
DID 1E57 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #25 SKODA_HVBAT_CELL_V_025
- Request
22 1E 58 - Service 22
DID 1E58 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #26 SKODA_HVBAT_CELL_V_026
- Request
22 1E 59 - Service 22
DID 1E59 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #27 SKODA_HVBAT_CELL_V_027
- Request
22 1E 5A - Service 22
DID 1E5A - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #28 SKODA_HVBAT_CELL_V_028
- Request
22 1E 5B - Service 22
DID 1E5B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #29 SKODA_HVBAT_CELL_V_029
- Request
22 1E 5C - Service 22
DID 1E5C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #30 SKODA_HVBAT_CELL_V_030
- Request
22 1E 5D - Service 22
DID 1E5D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #31 SKODA_HVBAT_CELL_V_031
- Request
22 1E 5E - Service 22
DID 1E5E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #32 SKODA_HVBAT_CELL_V_032
- Request
22 1E 5F - Service 22
DID 1E5F - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #33 SKODA_HVBAT_CELL_V_033
- Request
22 1E 60 - Service 22
DID 1E60 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #34 SKODA_HVBAT_CELL_V_034
- Request
22 1E 61 - Service 22
DID 1E61 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #35 SKODA_HVBAT_CELL_V_035
- Request
22 1E 62 - Service 22
DID 1E62 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #36 SKODA_HVBAT_CELL_V_036
- Request
22 1E 63 - Service 22
DID 1E63 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #37 SKODA_HVBAT_CELL_V_037
- Request
22 1E 64 - Service 22
DID 1E64 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #38 SKODA_HVBAT_CELL_V_038
- Request
22 1E 65 - Service 22
DID 1E65 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #39 SKODA_HVBAT_CELL_V_039
- Request
22 1E 66 - Service 22
DID 1E66 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #40 SKODA_HVBAT_CELL_V_040
- Request
22 1E 67 - Service 22
DID 1E67 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #41 SKODA_HVBAT_CELL_V_041
- Request
22 1E 68 - Service 22
DID 1E68 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #42 SKODA_HVBAT_CELL_V_042
- Request
22 1E 69 - Service 22
DID 1E69 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #43 SKODA_HVBAT_CELL_V_043
- Request
22 1E 6A - Service 22
DID 1E6A - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #44 SKODA_HVBAT_CELL_V_044
- Request
22 1E 6B - Service 22
DID 1E6B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #45 SKODA_HVBAT_CELL_V_045
- Request
22 1E 6C - Service 22
DID 1E6C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #46 SKODA_HVBAT_CELL_V_046
- Request
22 1E 6D - Service 22
DID 1E6D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #47 SKODA_HVBAT_CELL_V_047
- Request
22 1E 6E - Service 22
DID 1E6E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #48 SKODA_HVBAT_CELL_V_048
- Request
22 1E 6F - Service 22
DID 1E6F - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #49 SKODA_HVBAT_CELL_V_049
- Request
22 1E 70 - Service 22
DID 1E70 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #50 SKODA_HVBAT_CELL_V_050
- Request
22 1E 71 - Service 22
DID 1E71 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #51 SKODA_HVBAT_CELL_V_051
- Request
22 1E 72 - Service 22
DID 1E72 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #52 SKODA_HVBAT_CELL_V_052
- Request
22 1E 73 - Service 22
DID 1E73 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #53 SKODA_HVBAT_CELL_V_053
- Request
22 1E 74 - Service 22
DID 1E74 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #54 SKODA_HVBAT_CELL_V_054
- Request
22 1E 75 - Service 22
DID 1E75 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #55 SKODA_HVBAT_CELL_V_055
- Request
22 1E 76 - Service 22
DID 1E76 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #56 SKODA_HVBAT_CELL_V_056
- Request
22 1E 77 - Service 22
DID 1E77 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #57 SKODA_HVBAT_CELL_V_057
- Request
22 1E 78 - Service 22
DID 1E78 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #58 SKODA_HVBAT_CELL_V_058
- Request
22 1E 79 - Service 22
DID 1E79 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #59 SKODA_HVBAT_CELL_V_059
- Request
22 1E 7A - Service 22
DID 1E7A - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #60 SKODA_HVBAT_CELL_V_060
- Request
22 1E 7B - Service 22
DID 1E7B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #61 SKODA_HVBAT_CELL_V_061
- Request
22 1E 7C - Service 22
DID 1E7C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #62 SKODA_HVBAT_CELL_V_062
- Request
22 1E 7D - Service 22
DID 1E7D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #63 SKODA_HVBAT_CELL_V_063
- Request
22 1E 7E - Service 22
DID 1E7E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #64 SKODA_HVBAT_CELL_V_064
- Request
22 1E 7F - Service 22
DID 1E7F - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #65 SKODA_HVBAT_CELL_V_065
- Request
22 1E 80 - Service 22
DID 1E80 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #66 SKODA_HVBAT_CELL_V_066
- Request
22 1E 81 - Service 22
DID 1E81 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #67 SKODA_HVBAT_CELL_V_067
- Request
22 1E 82 - Service 22
DID 1E82 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #68 SKODA_HVBAT_CELL_V_068
- Request
22 1E 83 - Service 22
DID 1E83 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #69 SKODA_HVBAT_CELL_V_069
- Request
22 1E 84 - Service 22
DID 1E84 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #70 SKODA_HVBAT_CELL_V_070
- Request
22 1E 85 - Service 22
DID 1E85 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #71 SKODA_HVBAT_CELL_V_071
- Request
22 1E 86 - Service 22
DID 1E86 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #72 SKODA_HVBAT_CELL_V_072
- Request
22 1E 87 - Service 22
DID 1E87 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #73 SKODA_HVBAT_CELL_V_073
- Request
22 1E 88 - Service 22
DID 1E88 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #74 SKODA_HVBAT_CELL_V_074
- Request
22 1E 89 - Service 22
DID 1E89 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #75 SKODA_HVBAT_CELL_V_075
- Request
22 1E 8A - Service 22
DID 1E8A - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #76 SKODA_HVBAT_CELL_V_076
- Request
22 1E 8B - Service 22
DID 1E8B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #77 SKODA_HVBAT_CELL_V_077
- Request
22 1E 8C - Service 22
DID 1E8C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #78 SKODA_HVBAT_CELL_V_078
- Request
22 1E 8D - Service 22
DID 1E8D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #79 SKODA_HVBAT_CELL_V_079
- Request
22 1E 8E - Service 22
DID 1E8E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #80 SKODA_HVBAT_CELL_V_080
- Request
22 1E 8F - Service 22
DID 1E8F - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #81 SKODA_HVBAT_CELL_V_081
- Request
22 1E 90 - Service 22
DID 1E90 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #82 SKODA_HVBAT_CELL_V_082
- Request
22 1E 91 - Service 22
DID 1E91 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #83 SKODA_HVBAT_CELL_V_083
- Request
22 1E 92 - Service 22
DID 1E92 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #84 SKODA_HVBAT_CELL_V_084
- Request
22 1E 93 - Service 22
DID 1E93 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #85 SKODA_HVBAT_CELL_V_085
- Request
22 1E 94 - Service 22
DID 1E94 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #86 SKODA_HVBAT_CELL_V_086
- Request
22 1E 95 - Service 22
DID 1E95 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #87 SKODA_HVBAT_CELL_V_087
- Request
22 1E 96 - Service 22
DID 1E96 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #88 SKODA_HVBAT_CELL_V_088
- Request
22 1E 97 - Service 22
DID 1E97 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #89 SKODA_HVBAT_CELL_V_089
- Request
22 1E 98 - Service 22
DID 1E98 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #90 SKODA_HVBAT_CELL_V_090
- Request
22 1E 99 - Service 22
DID 1E99 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #91 SKODA_HVBAT_CELL_V_091
- Request
22 1E 9A - Service 22
DID 1E9A - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #92 SKODA_HVBAT_CELL_V_092
- Request
22 1E 9B - Service 22
DID 1E9B - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #93 SKODA_HVBAT_CELL_V_093
- Request
22 1E 9C - Service 22
DID 1E9C - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #94 SKODA_HVBAT_CELL_V_094
- Request
22 1E 9D - Service 22
DID 1E9D - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #95 SKODA_HVBAT_CELL_V_095
- Request
22 1E 9E - Service 22
DID 1E9E - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #96 SKODA_HVBAT_CELL_V_096
- Request
22 1E 9F - Service 22
DID 1E9F - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #97 SKODA_HVBAT_CELL_V_097
- Request
22 1E A0 - Service 22
DID 1EA0 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #98 SKODA_HVBAT_CELL_V_098
- Request
22 1E A1 - Service 22
DID 1EA1 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #99 SKODA_HVBAT_CELL_V_099
- Request
22 1E A2 - Service 22
DID 1EA2 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #100 SKODA_HVBAT_CELL_V_100
- Request
22 1E A3 - Service 22
DID 1EA3 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #101 SKODA_HVBAT_CELL_V_101
- Request
22 1E A4 - Service 22
DID 1EA4 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #102 SKODA_HVBAT_CELL_V_102
- Request
22 1E A5 - Service 22
DID 1EA5 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #103 SKODA_HVBAT_CELL_V_103
- Request
22 1E A6 - Service 22
DID 1EA6 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #104 SKODA_HVBAT_CELL_V_104
- Request
22 1E A7 - Service 22
DID 1EA7 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #105 SKODA_HVBAT_CELL_V_105
- Request
22 1E A8 - Service 22
DID 1EA8 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #106 SKODA_HVBAT_CELL_V_106
- Request
22 1E A9 - Service 22
DID 1EA9 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #107 SKODA_HVBAT_CELL_V_107
- Request
22 1E AA - Service 22
DID 1EAA - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery cell voltage, #108 SKODA_HVBAT_CELL_V_108
- Request
22 1E AB - Service 22
DID 1EAB - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 1 cell 1 state of charge SKODA_HVBAT_MOD1_C1_SOC
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 1 cell 1 voltage SKODA_HVBAT_MOD1_C1_V
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 1 cell 2 state of charge SKODA_HVBAT_MOD1_C2_SOC
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 1 cell 2 voltage SKODA_HVBAT_MOD1_C2_V
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 1 cell 3 state of charge SKODA_HVBAT_MOD1_C3_SOC
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 1 cell 3 voltage SKODA_HVBAT_MOD1_C3_V
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 1 cell 4 state of charge SKODA_HVBAT_MOD1_C4_SOC
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 1 cell 4 voltage SKODA_HVBAT_MOD1_C4_V
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 1 cell 5 state of charge SKODA_HVBAT_MOD1_C5_SOC
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 1 cell 5 voltage SKODA_HVBAT_MOD1_C5_V
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 1 cell 6 state of charge SKODA_HVBAT_MOD1_C6_SOC
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 1 cell 6 voltage SKODA_HVBAT_MOD1_C6_V
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 1 id SKODA_HVBAT_MOD1_ID
- Request
22 18 50 - Service 22
DID 1850 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 2 cell 1 state of charge SKODA_HVBAT_MOD2_C1_SOC
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 2 cell 1 voltage SKODA_HVBAT_MOD2_C1_V
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 2 cell 2 state of charge SKODA_HVBAT_MOD2_C2_SOC
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 2 cell 2 voltage SKODA_HVBAT_MOD2_C2_V
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 2 cell 3 state of charge SKODA_HVBAT_MOD2_C3_SOC
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 2 cell 3 voltage SKODA_HVBAT_MOD2_C3_V
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 2 cell 4 state of charge SKODA_HVBAT_MOD2_C4_SOC
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 2 cell 4 voltage SKODA_HVBAT_MOD2_C4_V
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 2 cell 5 state of charge SKODA_HVBAT_MOD2_C5_SOC
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 2 cell 5 voltage SKODA_HVBAT_MOD2_C5_V
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 2 cell 6 state of charge SKODA_HVBAT_MOD2_C6_SOC
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 2 cell 6 voltage SKODA_HVBAT_MOD2_C6_V
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 2 id SKODA_HVBAT_MOD2_ID
- Request
22 18 51 - Service 22
DID 1851 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 3 cell 1 state of charge SKODA_HVBAT_MOD3_C1_SOC
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 3 cell 1 voltage SKODA_HVBAT_MOD3_C1_V
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 3 cell 2 state of charge SKODA_HVBAT_MOD3_C2_SOC
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 3 cell 2 voltage SKODA_HVBAT_MOD3_C2_V
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 3 cell 3 state of charge SKODA_HVBAT_MOD3_C3_SOC
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 3 cell 3 voltage SKODA_HVBAT_MOD3_C3_V
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 3 cell 4 state of charge SKODA_HVBAT_MOD3_C4_SOC
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 3 cell 4 voltage SKODA_HVBAT_MOD3_C4_V
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 3 cell 5 state of charge SKODA_HVBAT_MOD3_C5_SOC
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 3 cell 5 voltage SKODA_HVBAT_MOD3_C5_V
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 3 cell 6 state of charge SKODA_HVBAT_MOD3_C6_SOC
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 3 cell 6 voltage SKODA_HVBAT_MOD3_C6_V
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 3 id SKODA_HVBAT_MOD3_ID
- Request
22 18 52 - Service 22
DID 1852 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 4 cell 1 state of charge SKODA_HVBAT_MOD4_C1_SOC
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 4 cell 1 voltage SKODA_HVBAT_MOD4_C1_V
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 4 cell 2 state of charge SKODA_HVBAT_MOD4_C2_SOC
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 4 cell 2 voltage SKODA_HVBAT_MOD4_C2_V
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 4 cell 3 state of charge SKODA_HVBAT_MOD4_C3_SOC
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 4 cell 3 voltage SKODA_HVBAT_MOD4_C3_V
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 4 cell 4 state of charge SKODA_HVBAT_MOD4_C4_SOC
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 4 cell 4 voltage SKODA_HVBAT_MOD4_C4_V
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 4 cell 5 state of charge SKODA_HVBAT_MOD4_C5_SOC
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 4 cell 5 voltage SKODA_HVBAT_MOD4_C5_V
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 4 cell 6 state of charge SKODA_HVBAT_MOD4_C6_SOC
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 4 cell 6 voltage SKODA_HVBAT_MOD4_C6_V
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 4 id SKODA_HVBAT_MOD4_ID
- Request
22 18 53 - Service 22
DID 1853 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 5 cell 1 state of charge SKODA_HVBAT_MOD5_C1_SOC
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 5 cell 1 voltage SKODA_HVBAT_MOD5_C1_V
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 5 cell 2 state of charge SKODA_HVBAT_MOD5_C2_SOC
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 5 cell 2 voltage SKODA_HVBAT_MOD5_C2_V
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 5 cell 3 state of charge SKODA_HVBAT_MOD5_C3_SOC
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 5 cell 3 voltage SKODA_HVBAT_MOD5_C3_V
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 5 cell 4 state of charge SKODA_HVBAT_MOD5_C4_SOC
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 5 cell 4 voltage SKODA_HVBAT_MOD5_C4_V
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 5 cell 5 state of charge SKODA_HVBAT_MOD5_C5_SOC
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 5 cell 5 voltage SKODA_HVBAT_MOD5_C5_V
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 5 cell 6 state of charge SKODA_HVBAT_MOD5_C6_SOC
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 5 cell 6 voltage SKODA_HVBAT_MOD5_C6_V
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 5 id SKODA_HVBAT_MOD5_ID
- Request
22 18 54 - Service 22
DID 1854 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 6 cell 1 state of charge SKODA_HVBAT_MOD6_C1_SOC
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 6 cell 1 voltage SKODA_HVBAT_MOD6_C1_V
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 6 cell 2 state of charge SKODA_HVBAT_MOD6_C2_SOC
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 6 cell 2 voltage SKODA_HVBAT_MOD6_C2_V
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 6 cell 3 state of charge SKODA_HVBAT_MOD6_C3_SOC
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 6 cell 3 voltage SKODA_HVBAT_MOD6_C3_V
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 6 cell 4 state of charge SKODA_HVBAT_MOD6_C4_SOC
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 6 cell 4 voltage SKODA_HVBAT_MOD6_C4_V
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 6 cell 5 state of charge SKODA_HVBAT_MOD6_C5_SOC
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 6 cell 5 voltage SKODA_HVBAT_MOD6_C5_V
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 6 cell 6 state of charge SKODA_HVBAT_MOD6_C6_SOC
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 6 cell 6 voltage SKODA_HVBAT_MOD6_C6_V
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 6 id SKODA_HVBAT_MOD6_ID
- Request
22 18 55 - Service 22
DID 1855 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 7 cell 1 state of charge SKODA_HVBAT_MOD7_C1_SOC
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 7 cell 1 voltage SKODA_HVBAT_MOD7_C1_V
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 7 cell 2 state of charge SKODA_HVBAT_MOD7_C2_SOC
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 7 cell 2 voltage SKODA_HVBAT_MOD7_C2_V
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 7 cell 3 state of charge SKODA_HVBAT_MOD7_C3_SOC
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 7 cell 3 voltage SKODA_HVBAT_MOD7_C3_V
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 7 cell 4 state of charge SKODA_HVBAT_MOD7_C4_SOC
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 7 cell 4 voltage SKODA_HVBAT_MOD7_C4_V
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 7 cell 5 state of charge SKODA_HVBAT_MOD7_C5_SOC
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 7 cell 5 voltage SKODA_HVBAT_MOD7_C5_V
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 7 cell 6 state of charge SKODA_HVBAT_MOD7_C6_SOC
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 7 cell 6 voltage SKODA_HVBAT_MOD7_C6_V
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 7 id SKODA_HVBAT_MOD7_ID
- Request
22 18 56 - Service 22
DID 1856 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 8 cell 1 state of charge SKODA_HVBAT_MOD8_C1_SOC
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 8 cell 1 voltage SKODA_HVBAT_MOD8_C1_V
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 8 cell 2 state of charge SKODA_HVBAT_MOD8_C2_SOC
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 8 cell 2 voltage SKODA_HVBAT_MOD8_C2_V
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 8 cell 3 state of charge SKODA_HVBAT_MOD8_C3_SOC
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 8 cell 3 voltage SKODA_HVBAT_MOD8_C3_V
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 8 cell 4 state of charge SKODA_HVBAT_MOD8_C4_SOC
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 8 cell 4 voltage SKODA_HVBAT_MOD8_C4_V
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 8 cell 5 state of charge SKODA_HVBAT_MOD8_C5_SOC
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 8 cell 5 voltage SKODA_HVBAT_MOD8_C5_V
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 8 cell 6 state of charge SKODA_HVBAT_MOD8_C6_SOC
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 8 cell 6 voltage SKODA_HVBAT_MOD8_C6_V
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 8 id SKODA_HVBAT_MOD8_ID
- Request
22 18 57 - Service 22
DID 1857 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 9 cell 1 state of charge SKODA_HVBAT_MOD9_C1_SOC
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 9 cell 1 voltage SKODA_HVBAT_MOD9_C1_V
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 9 cell 2 state of charge SKODA_HVBAT_MOD9_C2_SOC
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 9 cell 2 voltage SKODA_HVBAT_MOD9_C2_V
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 9 cell 3 state of charge SKODA_HVBAT_MOD9_C3_SOC
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 9 cell 3 voltage SKODA_HVBAT_MOD9_C3_V
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 9 cell 4 state of charge SKODA_HVBAT_MOD9_C4_SOC
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 9 cell 4 voltage SKODA_HVBAT_MOD9_C4_V
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 9 cell 5 state of charge SKODA_HVBAT_MOD9_C5_SOC
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 9 cell 5 voltage SKODA_HVBAT_MOD9_C5_V
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 9 cell 6 state of charge SKODA_HVBAT_MOD9_C6_SOC
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 9 cell 6 voltage SKODA_HVBAT_MOD9_C6_V
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 9 id SKODA_HVBAT_MOD9_ID
- Request
22 18 58 - Service 22
DID 1858 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 10 cell 1 state of charge SKODA_HVBAT_MOD10_C1_SOC
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 10 cell 1 voltage SKODA_HVBAT_MOD10_C1_V
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 10 cell 2 state of charge SKODA_HVBAT_MOD10_C2_SOC
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 10 cell 2 voltage SKODA_HVBAT_MOD10_C2_V
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 10 cell 3 state of charge SKODA_HVBAT_MOD10_C3_SOC
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 10 cell 3 voltage SKODA_HVBAT_MOD10_C3_V
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 10 cell 4 state of charge SKODA_HVBAT_MOD10_C4_SOC
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 10 cell 4 voltage SKODA_HVBAT_MOD10_C4_V
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 10 cell 5 state of charge SKODA_HVBAT_MOD10_C5_SOC
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 10 cell 5 voltage SKODA_HVBAT_MOD10_C5_V
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 10 cell 6 state of charge SKODA_HVBAT_MOD10_C6_SOC
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 10 cell 6 voltage SKODA_HVBAT_MOD10_C6_V
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 10 id SKODA_HVBAT_MOD10_ID
- Request
22 18 59 - Service 22
DID 1859 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 11 cell 1 state of charge SKODA_HVBAT_MOD11_C1_SOC
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 11 cell 1 voltage SKODA_HVBAT_MOD11_C1_V
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 11 cell 2 state of charge SKODA_HVBAT_MOD11_C2_SOC
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 11 cell 2 voltage SKODA_HVBAT_MOD11_C2_V
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 11 cell 3 state of charge SKODA_HVBAT_MOD11_C3_SOC
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 11 cell 3 voltage SKODA_HVBAT_MOD11_C3_V
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 11 cell 4 state of charge SKODA_HVBAT_MOD11_C4_SOC
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 11 cell 4 voltage SKODA_HVBAT_MOD11_C4_V
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 11 cell 5 state of charge SKODA_HVBAT_MOD11_C5_SOC
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 11 cell 5 voltage SKODA_HVBAT_MOD11_C5_V
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 11 cell 6 state of charge SKODA_HVBAT_MOD11_C6_SOC
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 11 cell 6 voltage SKODA_HVBAT_MOD11_C6_V
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 11 id SKODA_HVBAT_MOD11_ID
- Request
22 18 5A - Service 22
DID 185A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 12 cell 1 state of charge SKODA_HVBAT_MOD12_C1_SOC
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 12 cell 1 voltage SKODA_HVBAT_MOD12_C1_V
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 12 cell 2 state of charge SKODA_HVBAT_MOD12_C2_SOC
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 12 cell 2 voltage SKODA_HVBAT_MOD12_C2_V
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 12 cell 3 state of charge SKODA_HVBAT_MOD12_C3_SOC
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 12 cell 3 voltage SKODA_HVBAT_MOD12_C3_V
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 12 cell 4 state of charge SKODA_HVBAT_MOD12_C4_SOC
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 12 cell 4 voltage SKODA_HVBAT_MOD12_C4_V
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 12 cell 5 state of charge SKODA_HVBAT_MOD12_C5_SOC
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 12 cell 5 voltage SKODA_HVBAT_MOD12_C5_V
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 12 cell 6 state of charge SKODA_HVBAT_MOD12_C6_SOC
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 12 cell 6 voltage SKODA_HVBAT_MOD12_C6_V
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 12 id SKODA_HVBAT_MOD12_ID
- Request
22 18 5B - Service 22
DID 185B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 13 cell 1 state of charge SKODA_HVBAT_MOD13_C1_SOC
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 13 cell 1 voltage SKODA_HVBAT_MOD13_C1_V
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 13 cell 2 state of charge SKODA_HVBAT_MOD13_C2_SOC
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 13 cell 2 voltage SKODA_HVBAT_MOD13_C2_V
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 13 cell 3 state of charge SKODA_HVBAT_MOD13_C3_SOC
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 13 cell 3 voltage SKODA_HVBAT_MOD13_C3_V
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 13 cell 4 state of charge SKODA_HVBAT_MOD13_C4_SOC
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 13 cell 4 voltage SKODA_HVBAT_MOD13_C4_V
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 13 cell 5 state of charge SKODA_HVBAT_MOD13_C5_SOC
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 13 cell 5 voltage SKODA_HVBAT_MOD13_C5_V
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 13 cell 6 state of charge SKODA_HVBAT_MOD13_C6_SOC
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 13 cell 6 voltage SKODA_HVBAT_MOD13_C6_V
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 13 id SKODA_HVBAT_MOD13_ID
- Request
22 18 5C - Service 22
DID 185C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 14 cell 1 state of charge SKODA_HVBAT_MOD14_C1_SOC
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 14 cell 1 voltage SKODA_HVBAT_MOD14_C1_V
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 14 cell 2 state of charge SKODA_HVBAT_MOD14_C2_SOC
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 14 cell 2 voltage SKODA_HVBAT_MOD14_C2_V
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 14 cell 3 state of charge SKODA_HVBAT_MOD14_C3_SOC
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 14 cell 3 voltage SKODA_HVBAT_MOD14_C3_V
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 14 cell 4 state of charge SKODA_HVBAT_MOD14_C4_SOC
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 14 cell 4 voltage SKODA_HVBAT_MOD14_C4_V
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 14 cell 5 state of charge SKODA_HVBAT_MOD14_C5_SOC
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 14 cell 5 voltage SKODA_HVBAT_MOD14_C5_V
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 14 cell 6 state of charge SKODA_HVBAT_MOD14_C6_SOC
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 14 cell 6 voltage SKODA_HVBAT_MOD14_C6_V
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 14 id SKODA_HVBAT_MOD14_ID
- Request
22 18 5D - Service 22
DID 185D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 15 cell 1 state of charge SKODA_HVBAT_MOD15_C1_SOC
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 15 cell 1 voltage SKODA_HVBAT_MOD15_C1_V
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 15 cell 2 state of charge SKODA_HVBAT_MOD15_C2_SOC
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 15 cell 2 voltage SKODA_HVBAT_MOD15_C2_V
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 15 cell 3 state of charge SKODA_HVBAT_MOD15_C3_SOC
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 15 cell 3 voltage SKODA_HVBAT_MOD15_C3_V
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 15 cell 4 state of charge SKODA_HVBAT_MOD15_C4_SOC
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 15 cell 4 voltage SKODA_HVBAT_MOD15_C4_V
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 15 cell 5 state of charge SKODA_HVBAT_MOD15_C5_SOC
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 15 cell 5 voltage SKODA_HVBAT_MOD15_C5_V
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 15 cell 6 state of charge SKODA_HVBAT_MOD15_C6_SOC
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 15 cell 6 voltage SKODA_HVBAT_MOD15_C6_V
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 15 id SKODA_HVBAT_MOD15_ID
- Request
22 18 5E - Service 22
DID 185E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 16 cell 1 state of charge SKODA_HVBAT_MOD16_C1_SOC
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 16 cell 1 voltage SKODA_HVBAT_MOD16_C1_V
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 16 cell 2 state of charge SKODA_HVBAT_MOD16_C2_SOC
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 16 cell 2 voltage SKODA_HVBAT_MOD16_C2_V
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 16 cell 3 state of charge SKODA_HVBAT_MOD16_C3_SOC
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 16 cell 3 voltage SKODA_HVBAT_MOD16_C3_V
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 16 cell 4 state of charge SKODA_HVBAT_MOD16_C4_SOC
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 16 cell 4 voltage SKODA_HVBAT_MOD16_C4_V
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 16 cell 5 state of charge SKODA_HVBAT_MOD16_C5_SOC
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 16 cell 5 voltage SKODA_HVBAT_MOD16_C5_V
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 16 cell 6 state of charge SKODA_HVBAT_MOD16_C6_SOC
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 16 cell 6 voltage SKODA_HVBAT_MOD16_C6_V
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 16 id SKODA_HVBAT_MOD16_ID
- Request
22 18 5F - Service 22
DID 185F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 17 cell 1 state of charge SKODA_HVBAT_MOD17_C1_SOC
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 17 cell 1 voltage SKODA_HVBAT_MOD17_C1_V
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 17 cell 2 state of charge SKODA_HVBAT_MOD17_C2_SOC
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 17 cell 2 voltage SKODA_HVBAT_MOD17_C2_V
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 17 cell 3 state of charge SKODA_HVBAT_MOD17_C3_SOC
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 17 cell 3 voltage SKODA_HVBAT_MOD17_C3_V
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 17 cell 4 state of charge SKODA_HVBAT_MOD17_C4_SOC
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 17 cell 4 voltage SKODA_HVBAT_MOD17_C4_V
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 17 cell 5 state of charge SKODA_HVBAT_MOD17_C5_SOC
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 17 cell 5 voltage SKODA_HVBAT_MOD17_C5_V
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 17 cell 6 state of charge SKODA_HVBAT_MOD17_C6_SOC
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 17 cell 6 voltage SKODA_HVBAT_MOD17_C6_V
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 17 id SKODA_HVBAT_MOD17_ID
- Request
22 18 60 - Service 22
DID 1860 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 18 cell 1 state of charge SKODA_HVBAT_MOD18_C1_SOC
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 18 cell 1 voltage SKODA_HVBAT_MOD18_C1_V
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 18 cell 2 state of charge SKODA_HVBAT_MOD18_C2_SOC
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 18 cell 2 voltage SKODA_HVBAT_MOD18_C2_V
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 18 cell 3 state of charge SKODA_HVBAT_MOD18_C3_SOC
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 18 cell 3 voltage SKODA_HVBAT_MOD18_C3_V
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 18 cell 4 state of charge SKODA_HVBAT_MOD18_C4_SOC
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 18 cell 4 voltage SKODA_HVBAT_MOD18_C4_V
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 18 cell 5 state of charge SKODA_HVBAT_MOD18_C5_SOC
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 18 cell 5 voltage SKODA_HVBAT_MOD18_C5_V
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 18 cell 6 state of charge SKODA_HVBAT_MOD18_C6_SOC
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 18 cell 6 voltage SKODA_HVBAT_MOD18_C6_V
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 18 id SKODA_HVBAT_MOD18_ID
- Request
22 18 61 - Service 22
DID 1861 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 19 cell 1 state of charge SKODA_HVBAT_MOD19_C1_SOC
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 19 cell 1 voltage SKODA_HVBAT_MOD19_C1_V
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 19 cell 2 state of charge SKODA_HVBAT_MOD19_C2_SOC
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 19 cell 2 voltage SKODA_HVBAT_MOD19_C2_V
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 19 cell 3 state of charge SKODA_HVBAT_MOD19_C3_SOC
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 19 cell 3 voltage SKODA_HVBAT_MOD19_C3_V
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 19 cell 4 state of charge SKODA_HVBAT_MOD19_C4_SOC
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 19 cell 4 voltage SKODA_HVBAT_MOD19_C4_V
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 19 cell 5 state of charge SKODA_HVBAT_MOD19_C5_SOC
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 19 cell 5 voltage SKODA_HVBAT_MOD19_C5_V
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 19 cell 6 state of charge SKODA_HVBAT_MOD19_C6_SOC
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 19 cell 6 voltage SKODA_HVBAT_MOD19_C6_V
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 19 id SKODA_HVBAT_MOD19_ID
- Request
22 18 62 - Service 22
DID 1862 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 20 cell 1 state of charge SKODA_HVBAT_MOD20_C1_SOC
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 20 cell 1 voltage SKODA_HVBAT_MOD20_C1_V
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 20 cell 2 state of charge SKODA_HVBAT_MOD20_C2_SOC
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 20 cell 2 voltage SKODA_HVBAT_MOD20_C2_V
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 20 cell 3 state of charge SKODA_HVBAT_MOD20_C3_SOC
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 20 cell 3 voltage SKODA_HVBAT_MOD20_C3_V
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 20 cell 4 state of charge SKODA_HVBAT_MOD20_C4_SOC
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 20 cell 4 voltage SKODA_HVBAT_MOD20_C4_V
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 20 cell 5 state of charge SKODA_HVBAT_MOD20_C5_SOC
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 20 cell 5 voltage SKODA_HVBAT_MOD20_C5_V
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 20 cell 6 state of charge SKODA_HVBAT_MOD20_C6_SOC
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 20 cell 6 voltage SKODA_HVBAT_MOD20_C6_V
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 20 id SKODA_HVBAT_MOD20_ID
- Request
22 18 63 - Service 22
DID 1863 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 21 cell 1 state of charge SKODA_HVBAT_MOD21_C1_SOC
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 21 cell 1 voltage SKODA_HVBAT_MOD21_C1_V
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 21 cell 2 state of charge SKODA_HVBAT_MOD21_C2_SOC
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 21 cell 2 voltage SKODA_HVBAT_MOD21_C2_V
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 21 cell 3 state of charge SKODA_HVBAT_MOD21_C3_SOC
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 21 cell 3 voltage SKODA_HVBAT_MOD21_C3_V
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 21 cell 4 state of charge SKODA_HVBAT_MOD21_C4_SOC
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 21 cell 4 voltage SKODA_HVBAT_MOD21_C4_V
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 21 cell 5 state of charge SKODA_HVBAT_MOD21_C5_SOC
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 21 cell 5 voltage SKODA_HVBAT_MOD21_C5_V
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 21 cell 6 state of charge SKODA_HVBAT_MOD21_C6_SOC
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 21 cell 6 voltage SKODA_HVBAT_MOD21_C6_V
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 21 id SKODA_HVBAT_MOD21_ID
- Request
22 18 64 - Service 22
DID 1864 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 22 cell 1 state of charge SKODA_HVBAT_MOD22_C1_SOC
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 22 cell 1 voltage SKODA_HVBAT_MOD22_C1_V
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 22 cell 2 state of charge SKODA_HVBAT_MOD22_C2_SOC
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 22 cell 2 voltage SKODA_HVBAT_MOD22_C2_V
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 22 cell 3 state of charge SKODA_HVBAT_MOD22_C3_SOC
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 22 cell 3 voltage SKODA_HVBAT_MOD22_C3_V
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 22 cell 4 state of charge SKODA_HVBAT_MOD22_C4_SOC
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 22 cell 4 voltage SKODA_HVBAT_MOD22_C4_V
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 22 cell 5 state of charge SKODA_HVBAT_MOD22_C5_SOC
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 22 cell 5 voltage SKODA_HVBAT_MOD22_C5_V
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 22 cell 6 state of charge SKODA_HVBAT_MOD22_C6_SOC
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 22 cell 6 voltage SKODA_HVBAT_MOD22_C6_V
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 22 id SKODA_HVBAT_MOD22_ID
- Request
22 18 65 - Service 22
DID 1865 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 23 cell 1 state of charge SKODA_HVBAT_MOD23_C1_SOC
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 23 cell 1 voltage SKODA_HVBAT_MOD23_C1_V
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 23 cell 2 state of charge SKODA_HVBAT_MOD23_C2_SOC
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 23 cell 2 voltage SKODA_HVBAT_MOD23_C2_V
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 23 cell 3 state of charge SKODA_HVBAT_MOD23_C3_SOC
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 23 cell 3 voltage SKODA_HVBAT_MOD23_C3_V
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 23 cell 4 state of charge SKODA_HVBAT_MOD23_C4_SOC
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 23 cell 4 voltage SKODA_HVBAT_MOD23_C4_V
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 23 cell 5 state of charge SKODA_HVBAT_MOD23_C5_SOC
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 23 cell 5 voltage SKODA_HVBAT_MOD23_C5_V
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 23 cell 6 state of charge SKODA_HVBAT_MOD23_C6_SOC
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 23 cell 6 voltage SKODA_HVBAT_MOD23_C6_V
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 23 id SKODA_HVBAT_MOD23_ID
- Request
22 18 66 - Service 22
DID 1866 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 24 cell 1 state of charge SKODA_HVBAT_MOD24_C1_SOC
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 24 cell 1 voltage SKODA_HVBAT_MOD24_C1_V
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 24 cell 2 state of charge SKODA_HVBAT_MOD24_C2_SOC
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 24 cell 2 voltage SKODA_HVBAT_MOD24_C2_V
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 24 cell 3 state of charge SKODA_HVBAT_MOD24_C3_SOC
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 24 cell 3 voltage SKODA_HVBAT_MOD24_C3_V
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 24 cell 4 state of charge SKODA_HVBAT_MOD24_C4_SOC
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 24 cell 4 voltage SKODA_HVBAT_MOD24_C4_V
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 24 cell 5 state of charge SKODA_HVBAT_MOD24_C5_SOC
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 24 cell 5 voltage SKODA_HVBAT_MOD24_C5_V
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 24 cell 6 state of charge SKODA_HVBAT_MOD24_C6_SOC
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 24 cell 6 voltage SKODA_HVBAT_MOD24_C6_V
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 24 id SKODA_HVBAT_MOD24_ID
- Request
22 18 67 - Service 22
DID 1867 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 25 cell 1 state of charge SKODA_HVBAT_MOD25_C1_SOC
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 25 cell 1 voltage SKODA_HVBAT_MOD25_C1_V
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 25 cell 2 state of charge SKODA_HVBAT_MOD25_C2_SOC
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 25 cell 2 voltage SKODA_HVBAT_MOD25_C2_V
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 25 cell 3 state of charge SKODA_HVBAT_MOD25_C3_SOC
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 25 cell 3 voltage SKODA_HVBAT_MOD25_C3_V
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 25 cell 4 state of charge SKODA_HVBAT_MOD25_C4_SOC
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 25 cell 4 voltage SKODA_HVBAT_MOD25_C4_V
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 25 cell 5 state of charge SKODA_HVBAT_MOD25_C5_SOC
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 25 cell 5 voltage SKODA_HVBAT_MOD25_C5_V
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 25 cell 6 state of charge SKODA_HVBAT_MOD25_C6_SOC
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 25 cell 6 voltage SKODA_HVBAT_MOD25_C6_V
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 25 id SKODA_HVBAT_MOD25_ID
- Request
22 18 68 - Service 22
DID 1868 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 26 cell 1 state of charge SKODA_HVBAT_MOD26_C1_SOC
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 26 cell 1 voltage SKODA_HVBAT_MOD26_C1_V
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 26 cell 2 state of charge SKODA_HVBAT_MOD26_C2_SOC
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 26 cell 2 voltage SKODA_HVBAT_MOD26_C2_V
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 26 cell 3 state of charge SKODA_HVBAT_MOD26_C3_SOC
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 26 cell 3 voltage SKODA_HVBAT_MOD26_C3_V
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 26 cell 4 state of charge SKODA_HVBAT_MOD26_C4_SOC
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 26 cell 4 voltage SKODA_HVBAT_MOD26_C4_V
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 26 cell 5 state of charge SKODA_HVBAT_MOD26_C5_SOC
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 26 cell 5 voltage SKODA_HVBAT_MOD26_C5_V
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 26 cell 6 state of charge SKODA_HVBAT_MOD26_C6_SOC
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 26 cell 6 voltage SKODA_HVBAT_MOD26_C6_V
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 26 id SKODA_HVBAT_MOD26_ID
- Request
22 18 69 - Service 22
DID 1869 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 27 cell 1 state of charge SKODA_HVBAT_MOD27_C1_SOC
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 27 cell 1 voltage SKODA_HVBAT_MOD27_C1_V
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 27 cell 2 state of charge SKODA_HVBAT_MOD27_C2_SOC
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 27 cell 2 voltage SKODA_HVBAT_MOD27_C2_V
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 27 cell 3 state of charge SKODA_HVBAT_MOD27_C3_SOC
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 27 cell 3 voltage SKODA_HVBAT_MOD27_C3_V
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 27 cell 4 state of charge SKODA_HVBAT_MOD27_C4_SOC
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 27 cell 4 voltage SKODA_HVBAT_MOD27_C4_V
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 27 cell 5 state of charge SKODA_HVBAT_MOD27_C5_SOC
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 27 cell 5 voltage SKODA_HVBAT_MOD27_C5_V
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 27 cell 6 state of charge SKODA_HVBAT_MOD27_C6_SOC
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 27 cell 6 voltage SKODA_HVBAT_MOD27_C6_V
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 27 id SKODA_HVBAT_MOD27_ID
- Request
22 18 6A - Service 22
DID 186A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 28 cell 1 state of charge SKODA_HVBAT_MOD28_C1_SOC
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 28 cell 1 voltage SKODA_HVBAT_MOD28_C1_V
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 28 cell 2 state of charge SKODA_HVBAT_MOD28_C2_SOC
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 28 cell 2 voltage SKODA_HVBAT_MOD28_C2_V
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 28 cell 3 state of charge SKODA_HVBAT_MOD28_C3_SOC
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 28 cell 3 voltage SKODA_HVBAT_MOD28_C3_V
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 28 cell 4 state of charge SKODA_HVBAT_MOD28_C4_SOC
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 28 cell 4 voltage SKODA_HVBAT_MOD28_C4_V
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 28 cell 5 state of charge SKODA_HVBAT_MOD28_C5_SOC
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 28 cell 5 voltage SKODA_HVBAT_MOD28_C5_V
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 28 cell 6 state of charge SKODA_HVBAT_MOD28_C6_SOC
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 28 cell 6 voltage SKODA_HVBAT_MOD28_C6_V
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 28 id SKODA_HVBAT_MOD28_ID
- Request
22 18 6B - Service 22
DID 186B - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 29 cell 1 state of charge SKODA_HVBAT_MOD29_C1_SOC
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 29 cell 1 voltage SKODA_HVBAT_MOD29_C1_V
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 29 cell 2 state of charge SKODA_HVBAT_MOD29_C2_SOC
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 29 cell 2 voltage SKODA_HVBAT_MOD29_C2_V
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 29 cell 3 state of charge SKODA_HVBAT_MOD29_C3_SOC
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 29 cell 3 voltage SKODA_HVBAT_MOD29_C3_V
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 29 cell 4 state of charge SKODA_HVBAT_MOD29_C4_SOC
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 29 cell 4 voltage SKODA_HVBAT_MOD29_C4_V
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 29 cell 5 state of charge SKODA_HVBAT_MOD29_C5_SOC
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 29 cell 5 voltage SKODA_HVBAT_MOD29_C5_V
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 29 cell 6 state of charge SKODA_HVBAT_MOD29_C6_SOC
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 29 cell 6 voltage SKODA_HVBAT_MOD29_C6_V
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 29 id SKODA_HVBAT_MOD29_ID
- Request
22 18 6C - Service 22
DID 186C - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 30 cell 1 state of charge SKODA_HVBAT_MOD30_C1_SOC
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 30 cell 1 voltage SKODA_HVBAT_MOD30_C1_V
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 30 cell 2 state of charge SKODA_HVBAT_MOD30_C2_SOC
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 30 cell 2 voltage SKODA_HVBAT_MOD30_C2_V
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 30 cell 3 state of charge SKODA_HVBAT_MOD30_C3_SOC
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 30 cell 3 voltage SKODA_HVBAT_MOD30_C3_V
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 30 cell 4 state of charge SKODA_HVBAT_MOD30_C4_SOC
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 30 cell 4 voltage SKODA_HVBAT_MOD30_C4_V
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 30 cell 5 state of charge SKODA_HVBAT_MOD30_C5_SOC
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 30 cell 5 voltage SKODA_HVBAT_MOD30_C5_V
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 30 cell 6 state of charge SKODA_HVBAT_MOD30_C6_SOC
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 30 cell 6 voltage SKODA_HVBAT_MOD30_C6_V
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 30 id SKODA_HVBAT_MOD30_ID
- Request
22 18 6D - Service 22
DID 186D - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 31 cell 1 state of charge SKODA_HVBAT_MOD31_C1_SOC
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 31 cell 1 voltage SKODA_HVBAT_MOD31_C1_V
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 31 cell 2 state of charge SKODA_HVBAT_MOD31_C2_SOC
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 31 cell 2 voltage SKODA_HVBAT_MOD31_C2_V
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 31 cell 3 state of charge SKODA_HVBAT_MOD31_C3_SOC
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 31 cell 3 voltage SKODA_HVBAT_MOD31_C3_V
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 31 cell 4 state of charge SKODA_HVBAT_MOD31_C4_SOC
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 31 cell 4 voltage SKODA_HVBAT_MOD31_C4_V
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 31 cell 5 state of charge SKODA_HVBAT_MOD31_C5_SOC
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 31 cell 5 voltage SKODA_HVBAT_MOD31_C5_V
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 31 cell 6 state of charge SKODA_HVBAT_MOD31_C6_SOC
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 31 cell 6 voltage SKODA_HVBAT_MOD31_C6_V
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 31 id SKODA_HVBAT_MOD31_ID
- Request
22 18 6E - Service 22
DID 186E - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 31 id SKODA_HVBAT_MOD33_ID
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 32 cell 1 state of charge SKODA_HVBAT_MOD32_C1_SOC
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 32 cell 1 voltage SKODA_HVBAT_MOD32_C1_V
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 32 cell 2 state of charge SKODA_HVBAT_MOD32_C2_SOC
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 32 cell 2 voltage SKODA_HVBAT_MOD32_C2_V
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 32 cell 3 state of charge SKODA_HVBAT_MOD32_C3_SOC
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 32 cell 3 voltage SKODA_HVBAT_MOD32_C3_V
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 32 cell 4 state of charge SKODA_HVBAT_MOD32_C4_SOC
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 32 cell 4 voltage SKODA_HVBAT_MOD32_C4_V
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 32 cell 5 state of charge SKODA_HVBAT_MOD32_C5_SOC
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 32 cell 5 voltage SKODA_HVBAT_MOD32_C5_V
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 32 cell 6 state of charge SKODA_HVBAT_MOD32_C6_SOC
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 32 cell 6 voltage SKODA_HVBAT_MOD32_C6_V
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 32 id SKODA_HVBAT_MOD32_ID
- Request
22 18 6F - Service 22
DID 186F - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2023.
HV battery module 33 cell 1 state of charge SKODA_HVBAT_MOD33_C1_SOC
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 33 cell 1 voltage SKODA_HVBAT_MOD33_C1_V
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 33 cell 2 state of charge SKODA_HVBAT_MOD33_C2_SOC
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 33 cell 2 voltage SKODA_HVBAT_MOD33_C2_V
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 33 cell 3 state of charge SKODA_HVBAT_MOD33_C3_SOC
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 33 cell 3 voltage SKODA_HVBAT_MOD33_C3_V
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 33 cell 4 state of charge SKODA_HVBAT_MOD33_C4_SOC
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 33 cell 4 voltage SKODA_HVBAT_MOD33_C4_V
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 33 cell 5 state of charge SKODA_HVBAT_MOD33_C5_SOC
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 33 cell 5 voltage SKODA_HVBAT_MOD33_C5_V
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
HV battery module 33 cell 6 state of charge SKODA_HVBAT_MOD33_C6_SOC
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2023.
HV battery module 33 cell 6 voltage SKODA_HVBAT_MOD33_C6_V
- Request
22 18 70 - Service 22
DID 1870 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.5 V
- Unit
- V
In testing for 2012 to 2023.
Battery › Internal
Average battery consumption SKODA_HVBAT_CSMP_AVG_INT
- Request
22 2A B4 - Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2012 to 2023.
Estimated electric power reserve SKODA_RANGE_EST_INT
- Request
22 2A B4 - Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2012 to 2023.
Battery › Modules
HV battery module temperature, #5 SKODA_HVBAT_MOD_T_5
- Request
22 1E B2 - Service 22
DID 1EB2 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #6 SKODA_HVBAT_MOD_T_6
- Request
22 1E B3 - Service 22
DID 1EB3 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #7 SKODA_HVBAT_MOD_T_7
- Request
22 1E B4 - Service 22
DID 1EB4 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #8 SKODA_HVBAT_MOD_T_8
- Request
22 1E B5 - Service 22
DID 1EB5 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #9 SKODA_HVBAT_MOD_T_9
- Request
22 1E B6 - Service 22
DID 1EB6 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #10 SKODA_HVBAT_MOD_T_10
- Request
22 1E B7 - Service 22
DID 1EB7 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #11 SKODA_HVBAT_MOD_T_11
- Request
22 1E B8 - Service 22
DID 1EB8 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #12 SKODA_HVBAT_MOD_T_12
- Request
22 1E B9 - Service 22
DID 1EB9 - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #13 SKODA_HVBAT_MOD_T_13
- Request
22 1E BA - Service 22
DID 1EBA - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #14 SKODA_HVBAT_MOD_T_14
- Request
22 1E BB - Service 22
DID 1EBB - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #15 SKODA_HVBAT_MOD_T_15
- Request
22 1E BC - Service 22
DID 1EBC - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
HV battery module temperature, #16 SKODA_HVBAT_MOD_T_16
- Request
22 1E BD - Service 22
DID 1EBD - Module
FC00 → FE007B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 1, temperature 1 SKODA_HVBAT_MOD1_T1
- Request
22 18 21 - Service 22
DID 1821 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 1, temperature 2 SKODA_HVBAT_MOD1_T2
- Request
22 18 21 - Service 22
DID 1821 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 1, temperature 3 SKODA_HVBAT_MOD1_T3
- Request
22 18 21 - Service 22
DID 1821 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 2, temperature 1 SKODA_HVBAT_MOD2_T1
- Request
22 18 22 - Service 22
DID 1822 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 2, temperature 2 SKODA_HVBAT_MOD2_T2
- Request
22 18 22 - Service 22
DID 1822 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 2, temperature 3 SKODA_HVBAT_MOD2_T3
- Request
22 18 22 - Service 22
DID 1822 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 3, temperature 1 SKODA_HVBAT_MOD3_T1
- Request
22 18 23 - Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 3, temperature 2 SKODA_HVBAT_MOD3_T2
- Request
22 18 23 - Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 3, temperature 3 SKODA_HVBAT_MOD3_T3
- Request
22 18 23 - Service 22
DID 1823 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 4, temperature 1 SKODA_HVBAT_MOD4_T1
- Request
22 18 24 - Service 22
DID 1824 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 4, temperature 2 SKODA_HVBAT_MOD4_T2
- Request
22 18 24 - Service 22
DID 1824 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 4, temperature 3 SKODA_HVBAT_MOD4_T3
- Request
22 18 24 - Service 22
DID 1824 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 5, temperature 1 SKODA_HVBAT_MOD5_T1
- Request
22 18 25 - Service 22
DID 1825 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 5, temperature 2 SKODA_HVBAT_MOD5_T2
- Request
22 18 25 - Service 22
DID 1825 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 5, temperature 3 SKODA_HVBAT_MOD5_T3
- Request
22 18 25 - Service 22
DID 1825 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 6, temperature 1 SKODA_HVBAT_MOD6_T1
- Request
22 18 26 - Service 22
DID 1826 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 6, temperature 2 SKODA_HVBAT_MOD6_T2
- Request
22 18 26 - Service 22
DID 1826 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 6, temperature 3 SKODA_HVBAT_MOD6_T3
- Request
22 18 26 - Service 22
DID 1826 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 7, temperature 1 SKODA_HVBAT_MOD7_T1
- Request
22 18 27 - Service 22
DID 1827 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 7, temperature 2 SKODA_HVBAT_MOD7_T2
- Request
22 18 27 - Service 22
DID 1827 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 7, temperature 3 SKODA_HVBAT_MOD7_T3
- Request
22 18 27 - Service 22
DID 1827 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 8, temperature 1 SKODA_HVBAT_MOD8_T1
- Request
22 18 28 - Service 22
DID 1828 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 8, temperature 2 SKODA_HVBAT_MOD8_T2
- Request
22 18 28 - Service 22
DID 1828 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 8, temperature 3 SKODA_HVBAT_MOD8_T3
- Request
22 18 28 - Service 22
DID 1828 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 9, temperature 1 SKODA_HVBAT_MOD9_T1
- Request
22 18 29 - Service 22
DID 1829 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 9, temperature 2 SKODA_HVBAT_MOD9_T2
- Request
22 18 29 - Service 22
DID 1829 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 9, temperature 3 SKODA_HVBAT_MOD9_T3
- Request
22 18 29 - Service 22
DID 1829 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 10, temperature 1 SKODA_HVBAT_MOD10_T1
- Request
22 18 2A - Service 22
DID 182A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 10, temperature 2 SKODA_HVBAT_MOD10_T2
- Request
22 18 2A - Service 22
DID 182A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 10, temperature 3 SKODA_HVBAT_MOD10_T3
- Request
22 18 2A - Service 22
DID 182A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 11, temperature 1 SKODA_HVBAT_MOD11_T1
- Request
22 18 2B - Service 22
DID 182B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 11, temperature 2 SKODA_HVBAT_MOD11_T2
- Request
22 18 2B - Service 22
DID 182B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 11, temperature 3 SKODA_HVBAT_MOD11_T3
- Request
22 18 2B - Service 22
DID 182B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 12, temperature 1 SKODA_HVBAT_MOD12_T1
- Request
22 18 2C - Service 22
DID 182C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 12, temperature 2 SKODA_HVBAT_MOD12_T2
- Request
22 18 2C - Service 22
DID 182C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 12, temperature 3 SKODA_HVBAT_MOD12_T3
- Request
22 18 2C - Service 22
DID 182C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 13, temperature 1 SKODA_HVBAT_MOD13_T1
- Request
22 18 2D - Service 22
DID 182D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 13, temperature 2 SKODA_HVBAT_MOD13_T2
- Request
22 18 2D - Service 22
DID 182D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 13, temperature 3 SKODA_HVBAT_MOD13_T3
- Request
22 18 2D - Service 22
DID 182D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 14, temperature 1 SKODA_HVBAT_MOD14_T1
- Request
22 18 2E - Service 22
DID 182E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 14, temperature 2 SKODA_HVBAT_MOD14_T2
- Request
22 18 2E - Service 22
DID 182E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 14, temperature 3 SKODA_HVBAT_MOD14_T3
- Request
22 18 2E - Service 22
DID 182E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 15, temperature 1 SKODA_HVBAT_MOD15_T1
- Request
22 18 2F - Service 22
DID 182F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 15, temperature 2 SKODA_HVBAT_MOD15_T2
- Request
22 18 2F - Service 22
DID 182F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 15, temperature 3 SKODA_HVBAT_MOD15_T3
- Request
22 18 2F - Service 22
DID 182F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 16, temperature 1 SKODA_HVBAT_MOD16_T1
- Request
22 18 30 - Service 22
DID 1830 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 16, temperature 2 SKODA_HVBAT_MOD16_T2
- Request
22 18 30 - Service 22
DID 1830 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 16, temperature 3 SKODA_HVBAT_MOD16_T3
- Request
22 18 30 - Service 22
DID 1830 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 17, temperature 1 SKODA_HVBAT_MOD17_T1
- Request
22 18 31 - Service 22
DID 1831 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 17, temperature 2 SKODA_HVBAT_MOD17_T2
- Request
22 18 31 - Service 22
DID 1831 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 17, temperature 3 SKODA_HVBAT_MOD17_T3
- Request
22 18 31 - Service 22
DID 1831 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 18, temperature 1 SKODA_HVBAT_MOD18_T1
- Request
22 18 32 - Service 22
DID 1832 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 18, temperature 2 SKODA_HVBAT_MOD18_T2
- Request
22 18 32 - Service 22
DID 1832 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 18, temperature 3 SKODA_HVBAT_MOD18_T3
- Request
22 18 32 - Service 22
DID 1832 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 19, temperature 1 SKODA_HVBAT_MOD19_T1
- Request
22 18 33 - Service 22
DID 1833 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 19, temperature 2 SKODA_HVBAT_MOD19_T2
- Request
22 18 33 - Service 22
DID 1833 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 19, temperature 3 SKODA_HVBAT_MOD19_T3
- Request
22 18 33 - Service 22
DID 1833 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 20, temperature 1 SKODA_HVBAT_MOD20_T1
- Request
22 18 34 - Service 22
DID 1834 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 20, temperature 2 SKODA_HVBAT_MOD20_T2
- Request
22 18 34 - Service 22
DID 1834 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 20, temperature 3 SKODA_HVBAT_MOD20_T3
- Request
22 18 34 - Service 22
DID 1834 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 21, temperature 1 SKODA_HVBAT_MOD21_T1
- Request
22 18 35 - Service 22
DID 1835 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 21, temperature 2 SKODA_HVBAT_MOD21_T2
- Request
22 18 35 - Service 22
DID 1835 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 21, temperature 3 SKODA_HVBAT_MOD21_T3
- Request
22 18 35 - Service 22
DID 1835 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 22, temperature 1 SKODA_HVBAT_MOD22_T1
- Request
22 18 36 - Service 22
DID 1836 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 22, temperature 2 SKODA_HVBAT_MOD22_T2
- Request
22 18 36 - Service 22
DID 1836 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 22, temperature 3 SKODA_HVBAT_MOD22_T3
- Request
22 18 36 - Service 22
DID 1836 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 23, temperature 1 SKODA_HVBAT_MOD23_T1
- Request
22 18 37 - Service 22
DID 1837 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 23, temperature 2 SKODA_HVBAT_MOD23_T2
- Request
22 18 37 - Service 22
DID 1837 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 23, temperature 3 SKODA_HVBAT_MOD23_T3
- Request
22 18 37 - Service 22
DID 1837 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 24, temperature 1 SKODA_HVBAT_MOD24_T1
- Request
22 18 38 - Service 22
DID 1838 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 24, temperature 2 SKODA_HVBAT_MOD24_T2
- Request
22 18 38 - Service 22
DID 1838 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 24, temperature 3 SKODA_HVBAT_MOD24_T3
- Request
22 18 38 - Service 22
DID 1838 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 25, temperature 1 SKODA_HVBAT_MOD25_T1
- Request
22 18 39 - Service 22
DID 1839 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 25, temperature 2 SKODA_HVBAT_MOD25_T2
- Request
22 18 39 - Service 22
DID 1839 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 25, temperature 3 SKODA_HVBAT_MOD25_T3
- Request
22 18 39 - Service 22
DID 1839 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 26, temperature 1 SKODA_HVBAT_MOD26_T1
- Request
22 18 3A - Service 22
DID 183A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 26, temperature 2 SKODA_HVBAT_MOD26_T2
- Request
22 18 3A - Service 22
DID 183A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 26, temperature 3 SKODA_HVBAT_MOD26_T3
- Request
22 18 3A - Service 22
DID 183A - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 27, temperature 1 SKODA_HVBAT_MOD27_T1
- Request
22 18 3B - Service 22
DID 183B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 27, temperature 2 SKODA_HVBAT_MOD27_T2
- Request
22 18 3B - Service 22
DID 183B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 27, temperature 3 SKODA_HVBAT_MOD27_T3
- Request
22 18 3B - Service 22
DID 183B - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 28, temperature 1 SKODA_HVBAT_MOD28_T1
- Request
22 18 3C - Service 22
DID 183C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 28, temperature 2 SKODA_HVBAT_MOD28_T2
- Request
22 18 3C - Service 22
DID 183C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 28, temperature 3 SKODA_HVBAT_MOD28_T3
- Request
22 18 3C - Service 22
DID 183C - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 29, temperature 1 SKODA_HVBAT_MOD29_T1
- Request
22 18 3D - Service 22
DID 183D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 29, temperature 2 SKODA_HVBAT_MOD29_T2
- Request
22 18 3D - Service 22
DID 183D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 29, temperature 3 SKODA_HVBAT_MOD29_T3
- Request
22 18 3D - Service 22
DID 183D - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 30, temperature 1 SKODA_HVBAT_MOD30_T1
- Request
22 18 3E - Service 22
DID 183E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 30, temperature 2 SKODA_HVBAT_MOD30_T2
- Request
22 18 3E - Service 22
DID 183E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 30, temperature 3 SKODA_HVBAT_MOD30_T3
- Request
22 18 3E - Service 22
DID 183E - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 31, temperature 1 SKODA_HVBAT_MOD31_T1
- Request
22 18 3F - Service 22
DID 183F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 31, temperature 2 SKODA_HVBAT_MOD31_T2
- Request
22 18 3F - Service 22
DID 183F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 31, temperature 3 SKODA_HVBAT_MOD31_T3
- Request
22 18 3F - Service 22
DID 183F - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 32, temperature 1 SKODA_HVBAT_MOD32_T1
- Request
22 18 40 - Service 22
DID 1840 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 32, temperature 2 SKODA_HVBAT_MOD32_T2
- Request
22 18 40 - Service 22
DID 1840 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 32, temperature 3 SKODA_HVBAT_MOD32_T3
- Request
22 18 40 - Service 22
DID 1840 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 33, temperature 1 SKODA_HVBAT_MOD33_T1
- Request
22 18 41 - Service 22
DID 1841 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 33, temperature 2 SKODA_HVBAT_MOD33_T2
- Request
22 18 41 - Service 22
DID 1841 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.
Module 33, temperature 3 SKODA_HVBAT_MOD33_T3
- Request
22 18 41 - Service 22
DID 1841 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2023.