Subaru Impreza

Engine parameters

The Subaru Impreza has 97 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine oil temperature IMPREZA_EOT_V2Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 E7
  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1992 to 2014, 2016 to 2026

Example reply from a 2015 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x83 = 131 → (131 − 40) = 91 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015. In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2014, 2018 to 2021, 2023 to 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute evap system vapor pressure EVAP_VPASAE J1979Confirmed

Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 53
  • Service 01PID 53
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kPa
Unit
kPa

Confirmed for 2015, 2024.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2009 to 2010, 2012 to 2015, 2018 to 2021, 2024. Supported for 2008, 2017, 2023, 2025.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2008 to 2015, 2018 to 2021, 2023 to 2025. Supported for 2017.

Ambient temperature for control IMPREZA_AMBIENT_T_CTRL

  • Request22 12 D1
  • Service 22DID 12D1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015, 2019 to 2021.

Ambient temperature for sensor signal IMPREZA_AMBIENT_T_SENS_SIGConfirmed

  • Request22 12 CE
  • Service 22DID 12CE
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1992 to 2014, 2016 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x83 = 131 → (131 ÷ 2 − 40) = 25.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2015, 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2008 to 2015, 2018 to 2021, 2023 to 2025. Supported for 2017.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Request01 2C
  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2008 to 2015, 2018 to 2021, 2023 to 2025.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2009, 2012 to 2015, 2018, 2024.

Continuously variable transmission temperature IMPREZA_CVT_TConfirmed

  • Request22 10 D2
  • Service 22DID 10D2
  • Module7A3 → 7AB
  • Every5 s
  • Testing for 1992 to 2023, 2026

Example reply from a 2025 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x4B = 75 → (75 − 50) = 25 °C

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

Confirmed for 2024 to 2025. In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023.

Coolant temperature IMPREZA_ECT

  • Request22 00 05
  • Service 22DID 0005
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2009, 2012 to 2014, 2016 to 2017, 2022, 2025 to 2026. Not supported for 2002, 2008, 2010 to 2011, 2015, 2018 to 2021, 2023 to 2024.

Coolant temperature IMPREZA_ECT_7E0

  • Request22 00 05
  • Service 22DID 0005
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2009, 2013, 2016 to 2017, 2022, 2025 to 2026. Not supported for 2002, 2008, 2010 to 2012, 2014 to 2015, 2018 to 2021, 2023 to 2024.

Cumulative ash ratio IMPREZA_CUM_ASH_RAT

  • Request22 11 49
  • Service 22DID 1149
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1992 to 2001, 2003 to 2007, 2009, 2012 to 2014, 2016 to 2017, 2022, 2025 to 2026. Not supported for 2002, 2008, 2010 to 2011, 2015, 2018 to 2021, 2023 to 2024.

Cumulative ash ratio IMPREZA_CUM_ASH_RAT_7E0

  • Request22 11 49
  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015, 2019 to 2021.

Diesel particulate filter regeneration attempts IMPREZA_DPF_REGEN_CNT

  • Request22 11 A1
  • Service 22DID 11A1
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Drive motor inverter temperature a IMPREZA_DRIVEMOTOR_INVERTER_T_A

  • Request22 10 66
  • Service 22DID 1066
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Drive motor inverter temperature b IMPREZA_DRIVEMOTOR_INVERTER_T_B

  • Request22 10 67
  • Service 22DID 1067
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Drive motor inverter temperature c IMPREZA_DRIVEMOTOR_INVERTER_T_C

  • Request22 10 68
  • Service 22DID 1068
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Drive motor temperature a IMPREZA_DRIVEMOTOR_T_A

  • Request22 10 6D
  • Service 22DID 106D
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 55)
Range
-55 to 200 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Drive motor temperature b IMPREZA_DRIVEMOTOR_T_B

  • Request22 10 6E
  • Service 22DID 106E
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 55)
Range
-55 to 200 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

EGR error EGR_ERRSAE J1979Confirmed

  • Request01 2D
  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Electric load feedback value IMPREZA_ELEC_LOAD_FEEDBACKConfirmed

  • Request22 12 8D
  • Service 22DID 128D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 100) = 0 g/s

Formula
(val ÷ 100)
Range
0 to 2.55 g/s
Unit
g/s

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Electric waste gate valve position sensor learning value at fully-closed position IMPREZA_EWG_VALVE_POSITION_SENSOR_LEARNING_CLOSED

  • Request22 10 D2
  • Service 22DID 10D2
  • Module7A2 → 7AA
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 39.8 ÷ 255 − 10)
Range
-10 to 29 mm
Unit
mm

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2009 to 2010, 2012 to 2015, 2018 to 2021, 2023 to 2024. Supported for 2008, 2011, 2017, 2025.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Request01 8E
  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request01 5C
  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 210 °C
Unit
°C

Confirmed for 2015, 2018 to 2021, 2023 to 2024.

Engine oil temperature IMPREZA_EOT_V2Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 E7
  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1992 to 2014, 2016 to 2026

Example reply from a 2015 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x83 = 131 → (131 − 40) = 91 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015. In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2014, 2018 to 2021, 2023 to 2025.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Request01 63
  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2024.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2009 to 2010, 2012 to 2015, 2018 to 2021, 2024. Supported for 2008, 2011, 2017, 2023, 2025.

Estimated catalyst temperature IMPREZA_ESTIMATED_CATALYST_T

  • Request22 11 4B
  • Service 22DID 114B
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 − 40)
Range
-40 to 1235 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Estimated DPF temperature IMPREZA_ESTIMATED_DPF_T

  • Request22 11 4C
  • Service 22DID 114C
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 − 40)
Range
-40 to 1235 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 32
  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4000)
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2009. Supported for 2008, 2010 to 2011, 2020.

Exhaust gas recirculation target valve opening angle IMPREZA_EGR_TARGET_VALVE_OPENING_ANGLE

  • Request22 11 1B
  • Service 22DID 111B
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Exhaust gas temperature at DPF inlet IMPREZA_EGT_DPF_INLET

  • Request22 00 3E
  • Service 22DID 003E
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Exhaust gas temperature, catalyst inlet IMPREZA_EGT_AT_CATALYST_INLET

  • Request22 00 3C
  • Service 22DID 003C
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Exhaust VVT cleaning self-recovery counter IMPREZA_EXH_VVT_CLEANINGConfirmed

  • Request22 11 BF
  • Service 22DID 11BF
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Exhaust VVT retard angle left IMPREZA_EXH_VVT_RETARD_ANG_LEFTConfirmed

  • Request22 10 ED
  • Service 22DID 10ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2014, 2016 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x32 = 50 → (50 − 50) = 0 °

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

Confirmed for 2015, 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010.

Exhaust VVT retard angle right IMPREZA_EXH_VVT_RETARD_ANGConfirmed

  • Request22 10 EC
  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2014, 2016 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x32 = 50 → (50 − 50) = 0 °

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

Confirmed for 2015, 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010.

Exhaust VVT retard, target angle left IMPREZA_EXH_VVT_RETARD_TGT_ANGConfirmed

  • Request22 12 92
  • Service 22DID 1292
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x32 = 50 → (50 − 50) = 0 °

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Exhaust VVT retard, target angle right IMPREZA_EXH_VVT_RETARD_TGTConfirmed

  • Request22 12 91
  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x32 = 50 → (50 − 50) = 0 °

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Fuel temperature IMPREZA_FUEL_T

  • Request22 10 A7
  • Service 22DID 10A7
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Idle A/C load correction IMPREZA_IDLE_AC_LOAD_CORRConfirmed

  • Request22 12 8C
  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 100) = 0 g/s

Formula
(val ÷ 100)
Range
0 to 2.55 g/s
Unit
g/s

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Idle dirty throttle correction IMPREZA_IDLE_DIRTY_THROTTLEConfirmed

  • Request22 12 8E
  • Service 22DID 128E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 15 of the reply, 16 bits.

0x7576 = 30070 → (30070 ÷ 100 − 300) = 0.7 g/s

Formula
(val ÷ 100 − 300)
Range
-300 to 355 g/s
Unit
g/s

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Idle mass air flow IMPREZA_IDLE_MAFConfirmed

  • Request22 12 89
  • Service 22DID 1289
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 15 of the reply, 16 bits.

0x012C = 300 → (300 ÷ 100) = 3 g/s

Formula
(val ÷ 100)
Range
0 to 655 g/s
Unit
g/s

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Idle mass air flow feedback correction IMPREZA_IDLE_MAF_FEEDBACKConfirmed

  • Request22 12 8A
  • Service 22DID 128A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 15 of the reply, 16 bits.

0x7515 = 29973 → (29973 ÷ 100 − 300) = -0.27 g/s

Formula
(val ÷ 100 − 300)
Range
-300 to 355 g/s
Unit
g/s

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Idle speed control learning value IMPREZA_IDLE_SPD_CTRLConfirmed

  • Request22 12 8B
  • Service 22DID 128B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 15 of the reply, 16 bits.

0x7520 = 29984 → (29984 ÷ 100 − 300) = -0.16 g/s

Formula
(val ÷ 100 − 300)
Range
-300 to 355 g/s
Unit
g/s

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Inlet air temperature IMPREZA_INLET_AIR_T

  • Request22 30 7A
  • Service 22DID 307A
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 1.8 − 40)
Range
-30 to 300 °F
Unit
°F

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Inlet air temperature, after air filter IMPREZA_INLET_AIR_T_AFTER_AIR_FILTER

  • Request22 11 1F
  • Service 22DID 111F
  • Module7A2 → 7AA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2016 to 2017, 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Intake VVT advance, target angle left IMPREZA_INT_VVT_ADVANCE_TGT_ANGConfirmed

  • Request22 12 90
  • Service 22DID 1290
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x1E = 30 → (30 − 50) = -20 °

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Intake VVT advance, target angle right IMPREZA_INT_VVT_ADVANCE_TGTConfirmed

  • Request22 12 8F
  • Service 22DID 128F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x1E = 30 → (30 − 50) = -20 °

Formula
(val − 50)
Range
-50 to 205 °
Unit
°

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Intake VVT cleaning self-recovery counter IMPREZA_INT_VVT_CLEANINGConfirmed

  • Request22 11 BE
  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Inverter temperature estimated IMPREZA_INVERTER_T_ESTIMATED

  • Request22 10 65
  • Service 22DID 1065
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2022, 2026. Not supported for 2002, 2008 to 2015, 2018 to 2021, 2023 to 2025.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Main throttle sensor IMPREZA_MAIN_THROTTLE_SENSConfirmed

  • Request22 12 77
  • Service 22DID 1277
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1992 to 2014, 2016 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x23 = 35 → (35 ÷ 50) = 0.7 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2015, 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010.

Mass air flow, average IMPREZA_MAF_AVGConfirmed

  • Request22 12 ED
  • Service 22DID 12ED
  • Module7A2
  • Every250 ms
  • Testing for 1992 to 2023, 2026

Example reply from a 2025 Subaru Impreza.

Bits 0 to 15 of the reply, 16 bits.

0x015A = 346 → (346 ÷ 100) = 3.46 g/s

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2024 to 2025. In testing for 1992 to 2001, 2003 to 2007, 2016, 2022, 2026. Not supported for 2002, 2008 to 2015, 2017 to 2021, 2023.

Primary boost control IMPREZA_PRIMARY_BOOST_CTRL

  • Request22 10 AC
  • Service 22DID 10AC
  • Module7A2 → 7AA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015, 2019 to 2021.

Primary boost control IMPREZA_PRIMARY_BOOST_CTRL_7E0

  • Request22 10 AC
  • Service 22DID 10AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015, 2019 to 2021.

Purge density learn value IMPREZA_PURGE_DENSITY_LEARNConfirmed

  • Request22 12 95
  • Service 22DID 1295
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1992 to 2018, 2022 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 332 ÷ 425 − 100)
Range
-100 to 99.1999 %
Unit
%

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2008 to 2015, 2018 to 2021, 2023 to 2025. Supported for 2017.

Sub throttle sensor IMPREZA_SUB_THROTTLE_SENSConfirmed

  • Request22 12 76
  • Service 22DID 1276
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1992 to 2014, 2016 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x4E = 78 → (78 ÷ 50) = 1.56 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2015, 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2009, 2012 to 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2017, 2019 to 2021, 2023, 2025.

Transmission fluid temperature IMPREZA_ATF_T

  • Request22 10 6B
  • Service 22DID 106B
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1992 to 2001, 2003 to 2007, 2009, 2013, 2016 to 2017, 2022, 2025 to 2026. Not supported for 2002, 2008, 2010 to 2012, 2014 to 2015, 2018 to 2021, 2023 to 2024.

Transmission lock-up IMPREZA_TRANS_LOCK_UPConfirmed

  • Request22 12 99
  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Trip counter IMPREZA_TRIP_CNTConfirmed

  • Request22 10 1E
  • Service 22DID 101E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1992 to 2014, 2016 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 15 of the reply, 16 bits.

0x1856 = 6230 → 6,230

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2015, 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010.

Tumble generator valve position sensor left IMPREZA_TUMBLE_GEN_VLV_POS_SENSConfirmed

  • Request22 10 B0
  • Service 22DID 10B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x37 = 55 → (55 ÷ 50) = 1.1 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Tumble generator valve position sensor right IMPREZA_TUMBLE_GEN_VLV_POSConfirmed

  • Request22 10 AF
  • Service 22DID 10AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1992 to 2018, 2022 to 2026

Example reply from a 2021 Subaru Impreza.

Bits 0 to 7 of the reply, 8 bits.

0x35 = 53 → (53 ÷ 50) = 1.06 V

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

Confirmed for 2019 to 2021. In testing for 1992 to 2009, 2011 to 2014, 2016 to 2018, 2022 to 2026. Not supported for 2010, 2015.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2009, 2012 to 2015, 2018, 2024.

Engine › AuxInputs

Auto Trans Neutral Drive Status N/D_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Glow plug lamp status GPL_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Manual Trans Neutral Gear Status N/G_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Power Take Off (PTO) Output Status PTO_STAT_AUXSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Recommended gear GEAR_RCMDSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 11 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Engine › AuxInputs › Internal

Auto trans neutral drive status supported N/D_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Glow plug lamp status supported GPL_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Manual trans neutral gear status supported N/G_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Power Take Off (PTO) output status supported PTO_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Recommended gear supported GEAR_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2012, 2015, 2018, 2024.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2009, 2012, 2015, 2018, 2020, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019, 2021, 2023, 2025.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2009, 2012, 2015, 2018, 2020, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019, 2021, 2023, 2025.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2009, 2012, 2015, 2018, 2020, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019, 2021, 2023, 2025.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2009, 2012, 2015, 2018, 2020, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019, 2021, 2023, 2025.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2009, 2012, 2015, 2018, 2020, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019, 2021, 2023, 2025.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2009, 2012, 2015, 2018, 2020, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019, 2021, 2023, 2025.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2009, 2012, 2015, 2018, 2020, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019, 2021, 2023, 2025.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2009, 2012, 2015, 2018, 2020, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019, 2021, 2023, 2025.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2012, 2015, 2018 to 2020, 2023 to 2024. Supported for 2008 to 2011, 2013 to 2014, 2021, 2025.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2009, 2012, 2015, 2018 to 2020, 2023 to 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2021, 2025.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Request01 15
  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2009, 2012, 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019 to 2021, 2023, 2025.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2009, 2012, 2015, 2018, 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2019 to 2021, 2023, 2025.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2012, 2015, 2018 to 2020, 2023 to 2024. Supported for 2008 to 2011, 2013 to 2014, 2021, 2025.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8196)
Range
0 to 7.999 V
Unit
V

Confirmed for 2009, 2012, 2015, 2018 to 2020, 2023 to 2024. Supported for 2008, 2010 to 2011, 2013 to 2014, 2017, 2021, 2025.