Actual gear ratio SUBARU_ACTUAL_GEAR_RATIO

  • Request22 11 3E
  • Service 22DID 113E
  • Module7A3 → 7AB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 256 ÷ 65535)
Range
0 to 256
Unit
Number

In testing for 1994 to 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Actual gear ratio SUBARU_ACTUAL_GEAR_RATIO

  • Request22 11 3E
  • Service 22DID 113E
  • Module7A3 → 7AB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 256 ÷ 65535)
Range
0 to 256
Unit
Number

In testing for 1994 to 2021.

AWD transfer clutch duty SUBARU_AWD_TRANSFER_DUTY

  • Request22 10 65
  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 1994 to 2021.

CVT fluid temperature SUBARU_CVT_T_V2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 10 17
  • Service 22DID 1017
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 1994 to 2021.

CVT gear ratio, actual SUBARU_CVT_RATIO

  • Request22 30 DA
  • Service 22DID 30DA
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 255)
Range
0 to 257
Unit
Number

In testing for 1994 to 2021.

CVT gear ratio, target SUBARU_CVT_RATIO_TGT

  • Request22 30 F8
  • Service 22DID 30F8
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 255)
Range
0 to 257
Unit
Number

In testing for 1994 to 2021.

CVT primary pulley speed SUBARU_CVT_PRI_PULLEY_RPM

  • Request22 30 0E
  • Service 22DID 300E
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1994 to 2021.

CVT secondary pulley speed SUBARU_CVT_SEC_PULLEY_RPM

  • Request22 30 D0
  • Service 22DID 30D0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1994 to 2021.

Target gear ratio SUBARU_TARGET_GEAR_RATIO

  • Request22 11 3D
  • Service 22DID 113D
  • Module7A3 → 7AB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 256 ÷ 65535)
Range
0 to 0.9961089494
Unit
Number

In testing for 1994 to 2021.

Torque converter lock-up duty SUBARU_CVT_LOCKUP_DUTY

  • Request22 10 45
  • Service 22DID 1045
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 1994 to 2021.

Turbine speed SUBARU_CVT_TURBINE_RPM

  • Request22 10 67
  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 32)
Range
0 to 8160 rpm
Unit
rpm

In testing for 1994 to 2021.