Subaru WRX

Engine parameters

The Subaru WRX has 64 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Absolute evap system vapor pressure EVAP_VPAConfirmed

Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 53
  • Service 01PID 53
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kPa
Unit
kPa

Confirmed for 2015 to 2018, 2020 to 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute evap system vapor pressure EVAP_VPASAE J1979Confirmed

Normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 53
  • Service 01PID 53
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327.675 kPa
Unit
kPa

Confirmed for 2015 to 2018, 2020 to 2023.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2015 to 2023. Supported for 2024.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2020, 2022 to 2023.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2015 to 2024.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2015 to 2023. Supported for 2024.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2015 to 2024.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2015 to 2023. Supported for 2024.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Request01 2C
  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2016 to 2018, 2021 to 2023. Supported for 2015, 2019 to 2020, 2024.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2015 to 2024.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2015 to 2023. Supported for 2024.

Commanded secondary air status AIR_STATSAE J1979Confirmed

  • Request01 12
  • Service 01PID 12
  • Module7E0 → 7E8
  • Every60 s

Bits 5 to 7 of the reply, 3 bits.

Unit
Named states
States
Raw valueStateMeaning
1UPSUpstream of first catalytic converter
2DNSDownstream of first catalytic converter inlet
4OFFAtmosphere / off
8DIAGPump commanded on for diagnostics

Confirmed for 2015, 2019 to 2020. Supported for 2016.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2015 to 2023.

Commanded wastegate A position WG_A_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2023.

Commanded wastegate B position WG_B_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2023.

EGR error EGR_ERRSAE J1979Confirmed

  • Request01 2D
  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2016 to 2018, 2021 to 2023. Supported for 2015, 2019 to 2020, 2024.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015 to 2024.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Request01 8E
  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2020, 2022 to 2023.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request01 5C
  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 210 °C
Unit
°C

Confirmed for 2016 to 2024.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Request01 63
  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2020, 2022 to 2023.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2015 to 2023. Supported for 2024.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015 to 2016, 2019 to 2020.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2016 to 2018, 2021 to 2023.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2016 to 2018, 2021 to 2023.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2015 to 2021.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2015 to 2023. Supported for 2024.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2015 to 2024.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2015 to 2024.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2015 to 2023.

Wastegate A position WG_A_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2023.

Wastegate B position WG_B_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2023.

Engine › AuxInputs

Auto Trans Neutral Drive Status N/D_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 14 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Glow plug lamp status GPL_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 12 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Manual Trans Neutral Gear Status N/G_STATSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 13 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Power Take Off (PTO) Output Status PTO_STAT_AUXSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Recommended gear GEAR_RCMDSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 11 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Engine › AuxInputs › Internal

Auto trans neutral drive status supported N/D_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Glow plug lamp status supported GPL_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Manual trans neutral gear status supported N/G_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Power Take Off (PTO) output status supported PTO_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Recommended gear supported GEAR_SUPSAE J1979Confirmed

  • Request01 65
  • Service 01PID 65
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2021, 2023.

Engine › Internal

Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2023.

Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2023.

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016 to 2018, 2021 to 2023.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016 to 2018, 2021 to 2023.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016 to 2018, 2021 to 2023.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016 to 2018, 2021 to 2023.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016 to 2018, 2021 to 2023.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2016 to 2018, 2021 to 2023.

Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2023.

Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2023.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023. Supported for 2016, 2019, 2022, 2024.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023. Supported for 2016, 2019, 2022, 2024.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023. Supported for 2016, 2019, 2022, 2024.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023. Supported for 2016, 2019, 2022, 2024.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023. Supported for 2016, 2019, 2022, 2024.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023. Supported for 2016, 2019, 2022, 2024.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023. Supported for 2016, 2019, 2022, 2024.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2015, 2017 to 2018, 2020 to 2021, 2023. Supported for 2016, 2019, 2022, 2024.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2015, 2017, 2019 to 2023. Supported for 2016, 2024.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2015, 2017 to 2023. Supported for 2016, 2024.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Request01 15
  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2015, 2018, 2020 to 2021. Supported for 2016 to 2017, 2019, 2022 to 2024.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2015, 2018, 2020 to 2021. Supported for 2016 to 2017, 2019, 2022 to 2024.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2015, 2017, 2019 to 2023. Supported for 2016, 2024.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8196)
Range
0 to 7.999 V
Unit
V

Confirmed for 2015, 2017 to 2023. Supported for 2016, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.