Battery parameters
The Tata Harrier has 29 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery TATA_12V_BATTERY
- Request
22 DD 02 - Service 22
DID DD02 - Module
753 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 2019 to 2026.
Battery capacity, maximum TATA_BATTERY_SOH_CAPACITY_MAX
- Request
22 49 1A - Service 22
DID 491A - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Battery capacity, minimum TATA_BATTERY_SOH_CAPACITY_MIN
- Request
22 49 19 - Service 22
DID 4919 - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Battery coolant in TATA_BATTERY_COOLANT_IN
- Request
22 49 1C - Service 22
DID 491C - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- -20 to 30 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery coolant out TATA_BATTERY_COOLANT_OUT
- Request
22 49 1B - Service 22
DID 491B - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- -20 to 30
- Unit
- Number
In testing for 2019 to 2026.
Battery power TATA_BATTERY_SOH_POWER
- Request
22 49 15 - Service 22
DID 4915 - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2019 to 2026.
Battery power, maximum TATA_BATTERY_SOH_POWER_MAX
- Request
22 49 17 - Service 22
DID 4917 - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2019 to 2026.
Battery power, minimum TATA_BATTERY_SOH_POWER_MIN
- Request
22 49 16 - Service 22
DID 4916 - Module
7E4 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5
- Unit
- Number
In testing for 2019 to 2026.
Battery state of health, average TATA_HVB_SOH
Pelican can show this parameter as the state of health.
- Request
22 49 18 - Service 22
DID 4918 - Module
7E4 → 7EC - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Battery temperature TATA_HVB_T
- Request
22 49 07 - Service 22
DID 4907 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature, maximum TATA_BATTERY_T_MAX
- Request
22 49 05 - Service 22
DID 4905 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery temperature, minimum TATA_BATTERY_T_MIN
- Request
22 49 06 - Service 22
DID 4906 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2026.
Battery voltage TATA_BAT_V
- Request
22 11 72 - Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 625 ÷ 10000)- Range
- 0 to 15.9375 V
- Unit
- V
In testing for 2019 to 2026.
Battery, maximum regen TATA_BATTERY_MAX_REGEN
- Request
22 49 13 - Service 22
DID 4913 - Module
7E4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 2019 to 2026.
Cell voltage, maximum TATA_HVB_CELL_V_MAX
- Request
22 49 03 - Service 22
DID 4903 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 32767 mV
- Unit
- mV
In testing for 2019 to 2026.
Cell voltage, minimum TATA_HVB_CELL_V_MIN
- Request
22 49 04 - Service 22
DID 4904 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 32767 mV
- Unit
- mV
In testing for 2019 to 2026.
Charge voltage TATA_CHARGE_V
- Request
22 49 8F - Service 22
DID 498F - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 200 to 240 V
- Unit
- V
In testing for 2019 to 2026.
Charge, current TATA_CHARGE_CUR
- Request
22 49 8F - Service 22
DID 498F - Module
7E5 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 40 A
- Unit
- A
In testing for 2019 to 2026.
Charger mode TATA_CHARGER_MODE
- Request
22 FE 0C - Service 22
DID FE0C - Module
7E5 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Charging state TATA_CHG_STATE
- Request
22 FD 37 - Service 22
DID FD37 - Module
7E5 - Every
10 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
29 | DC_CHARGING | DC fast charging |
48 | AC_CHARGING | AC charging |
In testing for 2019 to 2026.
Charging state, vehicle TATA_VEHICLE_STATE
- Request
22 FE 0C - Service 22
DID FE0C - Module
7E5 - Every
1 s - Testing
Bits 0 to 3 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_CHARGING | Not charging |
6 | CHARGING | Charging |
9 | INIT | Initializing |
10 | WAITING | Waiting |
In testing for 2019 to 2026.
Current TATA_HVB_CURR
- Request
22 49 0C - Service 22
DID 490C - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 40)- Range
- -500 to 1000 A
- Unit
- A
In testing for 2019 to 2026.
DCDC HV voltage in TATA_DCDC_HV_V_IN
- Request
22 48 37 - Service 22
DID 4837 - Module
753 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2019 to 2026.
DCDC voltage out TATA_DCDC_V_OUT
- Request
22 42 0A - Service 22
DID 420A - Module
753 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2019 to 2026.
High voltage battery voltage TATA_HVB_V
- Request
22 49 0F - Service 22
DID 490F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 450 V
- Unit
- V
In testing for 2019 to 2026.
Max discharge TATA_MAX_DISCHARGE
- Request
22 49 12 - Service 22
DID 4912 - Module
7E4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 80 kW
- Unit
- kW
In testing for 2019 to 2026.
State of charge TATA_SOC
Pelican can show this parameter as the state of charge.
- Request
22 49 10 - Service 22
DID 4910 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
State of charge, maximum TATA_SOC_MAX
- Request
22 49 14 - Service 22
DID 4914 - Module
7E4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
State of charge, minimum TATA_SOC_MIN
- Request
22 49 11 - Service 22
DID 4911 - Module
7E4 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.