Tata Tiago

Engine parameters

The Tata Tiago has 21 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient temperature TATA_AMBIENT_T

  • Request22 99 24
  • Service 22DID 9924
  • Module7E4
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Ambient temperature TATA_AMBIENT_T

  • Request22 99 24
  • Service 22DID 9924
  • Module7E4
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2026.

Cabin temperature TATA_CABIN_T

  • Request22 DD 04
  • Service 22DID DD04
  • Module7E4
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Charging status TATA_CHARGING

  • Request22 FE 0C
  • Service 22DID FE0C
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Connection status: connected TATA_CONNECTION_STS_CONNECTED

  • Request22 FE 0C
  • Service 22DID FE0C
  • Module7E5
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Contact ready TATA_CONTACT_READY

  • Request22 DA 2A
  • Service 22DID DA2A
  • Module732
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2016 to 2026.

DCDC, current out TATA_DCDC_CUR_OUT

  • Request22 42 08
  • Service 22DID 4208
  • Module753
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 A
Unit
A

In testing for 2016 to 2026.

Diesel particulate filter calculated max soot concentration TATA_DPF_CALC_MAX_SOOT

  • Request22 05 98
  • Service 22DID 0598
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 %
Unit
%

In testing for 2016 to 2026.

Diesel particulate filter remaining volume TATA_DPF_REMAINING_VOLUME

  • Request22 04 17
  • Service 22DID 0417
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 L
Unit
L

In testing for 2016 to 2026.

Diesel particulate filter soot TATA_DPF_SOOT

  • Request22 06 35
  • Service 22DID 0635
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5
Unit
Raw value

In testing for 2016 to 2026.

Diesel particulate filter soot mass TATA_DPF_SOOT_MASS

  • Request22 06 1F
  • Service 22DID 061F
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100
Unit
Raw value

In testing for 2016 to 2026.

Driving mode TATA_DRIVING_MODE

  • Request22 3B 4D
  • Service 22DID 3B4D
  • Module710
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Elapsed TATA_ELAPSED

  • Request22 DD 00
  • Service 22DID DD00
  • Module7E4
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

In testing for 2016 to 2026.

Exhaust fluid mass TATA_SCR_FLUID_MASS

  • Request22 05 FC
  • Service 22DID 05FC
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Raw value

In testing for 2016 to 2026.

Sump oil temperature TATA_SUMP_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request22 03 F3
  • Service 22DID 03F3
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Suspension height TATA_SUSPENSION_HEIGHT

  • Request22 3B 3C
  • Service 22DID 3B3C
  • Module710
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Suspension height front TATA_SUSPENSION_HEIGHT_FRONT

  • Request22 3B 71
  • Service 22DID 3B71
  • Module710
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Suspension height rear TATA_SUSPENSION_HEIGHT_REAR

  • Request22 3B 72
  • Service 22DID 3B72
  • Module710
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Suspension pressure front left TATA_SUSPENSION_PRES_FL

  • Request22 3B 04
  • Service 22DID 3B04
  • Module710
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 psi
Unit
psi

In testing for 2016 to 2026.

Suspension pressure front right TATA_SUSPENSION_PRES_FR

  • Request22 3B 03
  • Service 22DID 3B03
  • Module710
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 psi
Unit
psi

In testing for 2016 to 2026.

Suspension pressure rear left TATA_SUSPENSION_PRES_RL

  • Request22 3B 06
  • Service 22DID 3B06
  • Module710
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 psi
Unit
psi

In testing for 2016 to 2026.

Suspension pressure rear right TATA_SUSPENSION_PRES_RR

  • Request22 3B 05
  • Service 22DID 3B05
  • Module710
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 psi
Unit
psi

In testing for 2016 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.