Engine parameters
The Acura Integra has 98 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Actual engine torque TQ_ACTSAE J1979Confirmed
- Request
01 62 - Service 01
PID 62 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2023 to 2025. Supported for 2026.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2024 to 2026.
Air/gas ratio INTEGRA_AIRGAS_RATIOConfirmed
- Request
22 26 11 - Service 22
DID 2611 - Module
DA10 → 10 - Every
250 ms - Testing for 1988 to 2006
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025. Supported for 2023.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025. Supported for 2023.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2026.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025. Supported for 2023.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2025. Supported for 2023.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2023 to 2026.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2023 to 2024.
Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2023 to 2024.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2025 to 2026.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed
- Request
01 8E - Service 01
PID 8E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 125)- Range
- -125 to 130 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Engine reference torque TQ_REFSAE J1979Confirmed
- Request
01 63 - Service 01
PID 63 - Module
7E0 → 7E8 - Every
86400 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 23 - Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Fuel/air commanded equivalence ratio INTEGRA_FUELAIR_CARConfirmed
- Request
22 26 61 - Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing for 1988 to 2006
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 2229.081633)- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Generator INTEGRA_GENERATORConfirmed
- Request
22 26 10 - Service 22
DID 2610 - Module
DA10 → 10 - Every
5 s - Testing for 1988 to 2006
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Knock control INTEGRA_KNOCK_CONTROLConfirmed
ECU's determination of fuel quality.
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 1988 to 2006
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Raw value
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Request
01 56 - Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Maintenance, air cleaner INTEGRA_MAINT_AIR_CLN
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 2006, 2023 to 2026.
Maintenance, brake fluid INTEGRA_MAINT_BRK_FLD
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 2006, 2023 to 2026.
Maintenance, cabin filter INTEGRA_MAINT_CABIN_FLT
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 2006, 2023 to 2026.
Maintenance, engine coolant INTEGRA_MAINT_COOL
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 2006, 2023 to 2026.
Maintenance, general inspection INTEGRA_MAINT_INSP
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 2006, 2023 to 2026.
Maintenance, oil & filter INTEGRA_MAINT_OIL_FLT
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 2006, 2023 to 2026.
Maintenance, spark plugs & valves INTEGRA_MAINT_SPARK
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 2006, 2023 to 2026.
Maintenance, transmission fluid INTEGRA_MAINT_TRANS_FLD
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 2006, 2023 to 2026.
Mass Air Flow Sensor A MAFASAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2024 to 2025. Supported for 2023.
Mass Air Flow Sensor B MAFBSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2024 to 2025. Supported for 2023.
Misfire count, cylinder 1 INTEGRA_MIS_1Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1988 to 2006
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Misfire count, cylinder 2 INTEGRA_MIS_2Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1988 to 2006
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Misfire count, cylinder 3 INTEGRA_MIS_3Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1988 to 2006
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Misfire count, cylinder 4 INTEGRA_MIS_4Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 1988 to 2006
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Relative Throttle A Position TP_A_RELSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2023 to 2024.
Relative Throttle B Position TP_B_RELSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2023 to 2024.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2023 to 2026.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Request
01 55 - Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2025. Supported for 2023 to 2024.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Variable valve timing duty INTEGRA_VTC_DUTYConfirmed
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 1988 to 2006
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2026. In testing for 1988 to 2006.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025.
Engine › Internal
Boost bressure A control status BP_ASAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 78 to 79 of the reply, 2 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | BP_A_OL | Open loop |
2 | BP_A_CL | Closed loop |
3 | BP_A_FAULT | Fault |
Confirmed for 2025. Supported for 2023.
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023.
Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025.
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2024 to 2025. Supported for 2023, 2026.
MAF Sensor A supported MAFA_SUPSAE J1979Confirmed
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
MAF Sensor B supported MAFB_SUPSAE J1979Confirmed
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2025. Supported for 2023 to 2024.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2025. Supported for 2023 to 2024.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2025. Supported for 2023 to 2024.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2025. Supported for 2023 to 2024.
Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2024 to 2026.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2023 to 2025.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2024 to 2025. Supported for 2023, 2026.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023, 2026.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2024 to 2026.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8196)- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2023 to 2025.