Clock parameters
The Acura RDX has 4 clock parameters.
● Confirmed◆ In testing○ Supported× Not supported
Time since engine start ACURA_RUNTMConfirmed
How long it's been since the engine started.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2019 to 2020, 2022, 2024. In testing for 2007 to 2012, 2014, 2016 to 2018, 2021, 2023, 2025 to 2026. Not supported for 2013, 2015.
Time since engine start ACURA_RUNTM_PCM
How long it's been since the engine started.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2007 to 2026.
Time since engine start ACURA_RUNTM_V2Confirmed
How long it's been since the engine started.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA11 → 11 - Every
5 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2013. In testing for 2007 to 2012, 2014, 2016 to 2018, 2021, 2023, 2025 to 2026. Not supported for 2015, 2019 to 2020, 2022, 2024.
Time since engine start RUNTMSAE J1979Confirmed
Increments while the engine is running. Freezes if the engine stalls. Resets to zero during every control module power-up and when entering the key-on, engine off position. Limited to 65,535 seconds and will not wrap around to zero.
- Request
01 1F - Service 01
PID 1F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
Confirmed for 2015. Supported for 2013, 2019 to 2022, 2024.