ECU parameters
The Acura TLX has 9 ECU parameters.
● Confirmed◆ In testing○ Supported× Not supported
Knock control TLX_KNOCK_CTRLConfirmed
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing for 2016 to 2019, 2022 to 2024
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Number
Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.
Misfire count, cylinder 1 TLX_MISFIRE_1Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2016 to 2019, 2022 to 2024
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.
Misfire count, cylinder 2 TLX_MISFIRE_2Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2016 to 2019, 2022 to 2024
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.
Misfire count, cylinder 3 TLX_MISFIRE_3Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2016 to 2019, 2022 to 2024
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.
Misfire count, cylinder 4 TLX_MISFIRE_4Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2016 to 2019, 2022 to 2024
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.
Misfire count, cylinder 5 TLX_MISFIRE_5Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2016 to 2019, 2022 to 2024
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.
Misfire count, cylinder 6 TLX_MISFIRE_6Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing for 2016 to 2019, 2022 to 2024
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.
Oil pressure TLX_EOP
- Request
22 22 03 - Service 22
DID 2203 - Module
DA1D → 1D - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 2016 to 2019, 2022 to 2024. Not supported for 2015, 2020 to 2021, 2025.
Variable valve control TLX_VTEC_CTRLConfirmed
- Request
22 26 12 - Service 22
DID 2612 - Module
DA10 → 10 - Every
250 ms - Testing for 2016 to 2019, 2022 to 2024
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2015, 2020 to 2021, 2025. In testing for 2016 to 2019, 2022 to 2024.