Control parameters
The Audi Q3 has 8 control parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Request
01 11 - Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013, 2017 to 2018, 2020, 2023, 2025. Supported for 2019, 2021 to 2022, 2024.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Request
01 47 - Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2020, 2023, 2025. Supported for 2021 to 2022, 2024.
Directional stability control active Q3_MQB_CSS_ACTConfirmed
- Request
22 18 B6 - Service 22
DID 18B6 - Module
713 → 77D - Every
1 s - Testing for 2011 to 2016, 2021 to 2026
Example reply from a 2020 Audi Q3.
Bit 6 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017 to 2020. In testing for 2011 to 2012, 2014 to 2016, 2022, 2024, 2026. Not supported for 2013, 2021, 2023, 2025.
Directional stability control last activation distance Q3_MQB_CSS_ODO_LASTConfirmed
- Request
22 18 B6 - Service 22
DID 18B6 - Module
713 → 77D - Every
1 s - Testing for 2011 to 2016, 2021 to 2026
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 1 km
- Unit
- km
Confirmed for 2017 to 2020. In testing for 2011 to 2012, 2014 to 2016, 2022, 2024, 2026. Not supported for 2013, 2021, 2023, 2025.
Directional stability control steering torque Q3_MQB_CSS_STR_TRQConfirmed
- Request
22 18 B6 - Service 22
DID 18B6 - Module
713 → 77D - Every
1 s - Testing for 2011 to 2016, 2021 to 2026
Example reply from a 2020 Audi Q3.
Bits 32 to 47 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 1000) = 0 N·m
- Formula
(val ÷ 1000)- Range
- 0 to 1 N·m
- Unit
- N·m
Confirmed for 2017 to 2020. In testing for 2011 to 2012, 2014 to 2016, 2022, 2024, 2026. Not supported for 2013, 2021, 2023, 2025.
Hill descent control active Q3_MQB_HDC_ACTConfirmed
- Request
22 18 08 - Service 22
DID 1808 - Module
713 → 77D - Every
1 s - Testing for 2011 to 2016, 2021 to 2026
Example reply from a 2020 Audi Q3.
Bit 6 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2017 to 2020. In testing for 2011 to 2012, 2014 to 2016, 2022, 2024, 2026. Not supported for 2013, 2021, 2023, 2025.
Hill descent control incline angle Q3_MQB_HDC_INCConfirmed
- Request
22 18 08 - Service 22
DID 1808 - Module
713 → 77D - Every
1 s - Testing for 2011 to 2016, 2021 to 2026
Example reply from a 2020 Audi Q3.
Bits 8 to 15 of the reply, 8 bits.
0xFE = 254 → 254 %
- Formula
val- Range
- 0 to 255 %
- Unit
- %
Confirmed for 2017 to 2020. In testing for 2011 to 2012, 2014 to 2016, 2022, 2024, 2026. Not supported for 2013, 2021, 2023, 2025.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Request
01 45 - Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2023. Supported for 2013, 2017, 2019 to 2022, 2024.