Cadillac XT5

Transmission parameters

The Cadillac XT5 has 15 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Current gear, variant 3 XT5_CURRENT_GEAR_VAR_3Confirmed

  • Request22 32 01
  • Service 22DID 3201
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Current gear XT5_CURRENT_GEAR_7E0

  • Request22 19 9A
  • Service 22DID 199A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2017, 2019 to 2026. Not supported for 2018.

Current gear, variant 3 XT5_CURRENT_GEAR_VAR_3Confirmed

  • Request22 32 01
  • Service 22DID 3201
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter position indicator XT5_SHIFTER_POSConfirmed

  • Request22 1B 1A
  • Service 22DID 1B1A
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x77 = 119 → (119 − 146) = -27

Formula
(val − 146)
Range
-146 to 109
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter X position sensor 1 duty cycle XT5_SHIFTER_X_POS_SENS_1Confirmed

  • Request22 1B 1B
  • Service 22DID 1B1B
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x7C = 124 → 124

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter X position sensor 1 frequency XT5_SHIFTER_X_POS_SENS_1_FREQUENCYConfirmed

  • Request22 1B 1F
  • Service 22DID 1B1F
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x64 = 100 → 100

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter X position sensor 2 duty cycle XT5_SHIFTER_X_POS_SENS_2Confirmed

  • Request22 1B 1D
  • Service 22DID 1B1D
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x84 = 132 → 132

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter X position sensor 2 frequency XT5_SHIFTER_X_POS_SENS_2_FREQUENCYConfirmed

  • Request22 1B 21
  • Service 22DID 1B21
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x64 = 100 → 100

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter Y position sensor 1 duty cycle XT5_SHIFTER_Y_POS_SENS_1Confirmed

  • Request22 1B 1C
  • Service 22DID 1B1C
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x95 = 149 → 149

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter Y position sensor 1 frequency XT5_SHIFTER_Y_POS_SENS_1_FREQUENCYConfirmed

  • Request22 1B 20
  • Service 22DID 1B20
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter Y position sensor 2 duty cycle XT5_SHIFTER_Y_POS_SENS_2Confirmed

  • Request22 1B 1E
  • Service 22DID 1B1E
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x6C = 108 → 108

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Shifter Y position sensor 2 frequency XT5_SHIFTER_Y_POS_SENS_2_FREQUENCYConfirmed

  • Request22 1B 22
  • Service 22DID 1B22
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0x64 = 100 → 100

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission park position switch 1 XT5_TRANS_PARK_POS_1Confirmed

  • Request22 1B 23
  • Service 22DID 1B23
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0xA3 = 163 → 163

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission park position switch 2 XT5_TRANS_PARK_POS_2Confirmed

  • Request22 1B 24
  • Service 22DID 1B24
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0xA3 = 163 → 163

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission shift interlock switch 1 XT5_TRANS_SHIFT_1Confirmed

  • Request22 1B 25
  • Service 22DID 1B25
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0xC2 = 194 → 194

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Transmission shift interlock switch 2 XT5_TRANS_SHIFT_2Confirmed

  • Request22 1B 26
  • Service 22DID 1B26
  • Module7E3 → 7EB
  • Every1 s
  • Testing for 2016 to 2017, 2019 to 2026

Example reply from a 2018 Cadillac XT5.

Bits 0 to 7 of the reply, 8 bits.

0xC3 = 195 → 195

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.