The Chevrolet Impala has 3 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2007, 2011, 2013 to 2014, 2016 to 2017. Supported for 1996, 2018.
Ignition 1 voltage IMPALA_IGN_1_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 11 41 - Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1988 to 1996, 2000 to 2020.
M control module voltage IMPALA_M_CTRL_MODULE_V
- Request
22 00 42 - Service 22
DID 0042 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V