Chevrolet Impala

Engine parameters

The Chevrolet Impala has 104 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Calculated engine oil temperature IMPALA_EOT_CALCConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 11 54
  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x77 = 119 → (119 − 40) = 79 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

1-2 shift error IMPALA_1_2_SHIFT_ERROR

  • Request22 19 97
  • Service 22DID 1997
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1988 to 1996, 2000 to 2020.

1-2 shift time IMPALA_1_2_SHIFT_TIME

  • Request22 19 93
  • Service 22DID 1993
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1988 to 1996, 2000 to 2020.

2-3 shift error IMPALA_2_3_SHIFT_ERROR

  • Request22 19 98
  • Service 22DID 1998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1988 to 1996, 2000 to 2020.

2-3 shift time IMPALA_2_3_SHIFT_TIME

  • Request22 19 94
  • Service 22DID 1994
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1988 to 1996, 2000 to 2020.

3-4 shift error IMPALA_3_4_SHIFT_ERROR

  • Request22 19 99
  • Service 22DID 1999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1988 to 1996, 2000 to 2020.

3-4 shift time IMPALA_3_4_SHIFT_TIME

  • Request22 19 95
  • Service 22DID 1995
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1988 to 1996, 2000 to 2020.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2007, 2011, 2013.

Active grille cold temperature mode IMPALA_ACTIVE_GRILLE_COLD_T

  • Request22 23 9B
  • Service 22DID 239B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Active grille shutter position IMPALA_ACTIVE_GRILLE_SHUTTER_POS

  • Request22 23 66
  • Service 22DID 2366
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1996, 2000 to 2020.

Active grille shutter position command IMPALA_ACTIVE_GRILLE

  • Request22 23 64
  • Service 22DID 2364
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1996, 2000 to 2020.

Air conditioning high side pressure IMPALA_AC_HIGH_SIDE_P

  • Request22 15 64
  • Service 22DID 1564
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2.02)
Range
0 to 515.1 psi
Unit
psi

In testing for 1988 to 1996, 2000 to 2020.

Air filter life remaining IMPALA_AIRFILT_LIFE

  • Request22 36 A7
  • Service 22DID 36A7
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1988 to 1996, 2000 to 2020.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2007, 2011, 2013 to 2014, 2017, 2019. Supported for 1996, 2016, 2018, 2020.

Air/fuel ratio, commanded IMPALA_AIR_FUEL_RAT_CMD

  • Request22 11 9E
  • Service 22DID 119E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Ambient air temperature 2 IMPALA_AIR_TEMP_AMBIENT_2

  • Request22 23 2C
  • Service 22DID 232C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1996, 2000 to 2020.

Axle torque driver requested IMPALA_AXLE_TQ_DRIVER_REQ

  • Request22 24 34
  • Service 22DID 2434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 22534)
Range
-22534 to 43001 N·m
Unit
N·m

In testing for 1988 to 1996, 2000 to 2020.

Balance rate, cylinder 1 IMPALA_BALANCE_RATE_CYL_1

  • Request22 16 2F
  • Service 22DID 162F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Balance rate, cylinder 2 IMPALA_BALANCE_RATE_CYL_2

  • Request22 16 30
  • Service 22DID 1630
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Balance rate, cylinder 3 IMPALA_BALANCE_RATE_CYL_3

  • Request22 16 31
  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Balance rate, cylinder 4 IMPALA_BALANCE_RATE_CYL_4

  • Request22 16 32
  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Balance rate, cylinder 5 IMPALA_BALANCE_RATE_CYL_5

  • Request22 16 33
  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Balance rate, cylinder 6 IMPALA_BALANCE_RATE_CYL_6

  • Request22 16 34
  • Service 22DID 1634
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2011, 2013. Supported for 1996, 2007, 2014, 2016 to 2019.

Barometric pressure, V6 IMPALA_BAROMETRIC_P_V6

  • Request22 12 51
  • Service 22DID 1251
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1988 to 1996, 2000 to 2020.

Cabin A/C high side sensor voltage IMPALA_CABIN_AC_HIGH_SIDE_V

  • Request22 11 44
  • Service 22DID 1144
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 1988 to 1996, 2000 to 2020.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2007, 2011, 2013 to 2014, 2017, 2019. Supported for 1996, 2016, 2018, 2020.

Calculated engine oil pressure IMPALA_EOP_CALCConfirmed

  • Request22 1C 1B
  • Service 22DID 1C1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 400 ÷ 100) = 0 kPa

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Calculated engine oil temperature IMPALA_EOT_CALCConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 11 54
  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x77 = 119 → (119 − 40) = 79 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2007, 2011, 2013. Supported for 1996, 2014, 2016 to 2019.

Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed

  • Request01 3D
  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2013. Supported for 1996, 2018.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2007, 2011, 2013 to 2014, 2017, 2019.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2011, 2013. Supported for 1996, 2007, 2014, 2016 to 2020.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2011, 2013.

Cooling fan motor command IMPALA_COOLING_FAN_MOTOR_CMDConfirmed

  • Request22 13 AF
  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Cruise control status IMPALA_CRUISE_CTRL_STAT

  • Request22 20 67
  • Service 22DID 2067
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2007, 2011, 2013 to 2014, 2017, 2019. Supported for 1996, 2016, 2018, 2020.

Engine oil absolute pressure IMPALA_EOP_ABSConfirmed

  • Request22 23 44
  • Service 22DID 2344
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 400 ÷ 100) = 0 kPa

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Engine oil life remaining IMPALA_EO_LIFE_REMAINING

  • Request22 4D C0
  • Service 22DID 4DC0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1996, 2000 to 2020.

Engine oil pressure IMPALA_EOPConfirmed

  • Request22 23 45
  • Service 22DID 2345
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 400 ÷ 100) = 0 kPa

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Engine oil pressure IMPALA_EOP_DA11

  • Request22 14 70
  • Service 22DID 1470
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1988 to 1996, 2000 to 2020.

Engine oil pressure 2 IMPALA_EOP_2

Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.

  • Request22 11 5C
  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 5 − 21.6)
Range
-21.6 to 131.39 psi
Unit
psi

In testing for 1988 to 1996, 2000 to 2020.

Engine oil pressure control solenoid valve command IMPALA_EOP_CTRL_SOLENOID_VALVE_CMDConfirmed

  • Request22 33 18
  • Service 22DID 3318
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bit 0 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Engine oil temperature IMPALA_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 00 5C
  • Service 22DID 005C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1996, 2000 to 2020.

Engine oil temperature 2 IMPALA_EOT_2

  • Request22 15 3E
  • Service 22DID 153E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1996, 2000 to 2020.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2011, 2013. Supported for 1996, 2007, 2014, 2016 to 2020.

Engine torque IMPALA_ENG_TQ

  • Request22 19 DE
  • Service 22DID 19DE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1988 to 1996, 2000 to 2020.

Engine torque IMPALA_ENG_TQ_7E0

  • Request22 20 3F
  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 N·m
Unit
N·m

In testing for 1988 to 1996, 2000 to 2020.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 32
  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4000)
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2011, 2013. Supported for 2007, 2014, 2016 to 2020.

Evaporative emissions purge IMPALA_EVAPORATIVE

  • Request22 11 70
  • Service 22DID 1170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1996, 2000 to 2020.

Exhaust gas recirculation duty cycle IMPALA_EGR_DUTY

  • Request22 11 71
  • Service 22DID 1171
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1996, 2000 to 2020.

Exhaust gas recirculation voltage IMPALA_EGR_V

  • Request22 11 4B
  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 1988 to 1996, 2000 to 2020.

Fuel pressure FPSAE J1979Confirmed

  • Request01 0A
  • Service 01PID 0A
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3)
Range
0 to 765 kPa
Unit
kPa

Confirmed for 2013. Supported for 2014, 2016 to 2020.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 23
  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2013. Supported for 2014, 2016 to 2020.

Heated oxygen sensor IMPALA_HEATED_OXYGEN_SENS

  • Request22 11 45
  • Service 22DID 1145
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mV
Unit
mV

In testing for 1988 to 1996, 2000 to 2020.

Idle air control position IMPALA_IDLE_AIR_CTRL_POS

  • Request22 11 72
  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Ignition input on/off/start IMPALA_IGN_INPUT_ON_OFF

  • Request22 20 D0
  • Service 22DID 20D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Ignition power mode IMPALA_IGN_POWER_MODE

  • Request22 20 7E
  • Service 22DID 207E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Injector duty cycle bank 1 IMPALA_INJECTOR_DUTY_CYCLE_BANK_1Confirmed

  • Request22 12 C3
  • Service 22DID 12C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 15 of the reply, 16 bits.

0x0037 = 55 → (55 × 150 ÷ 10000) = 0.825 ms

Formula
(val × 150 ÷ 10000)
Range
0 to 983.025 ms
Unit
ms

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Injector duty cycle bank 2 IMPALA_INJECTOR_DUTY_CYCLE_BANK_2Confirmed

  • Request22 12 C4
  • Service 22DID 12C4
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 15 of the reply, 16 bits.

0x0049 = 73 → (73 × 150 ÷ 10000) = 1.095 ms

Formula
(val × 150 ÷ 10000)
Range
0 to 983.025 ms
Unit
ms

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Injector pulse width, cylinder 1 IMPALA_INJ_WIDTH_CYL_1

  • Request22 11 93
  • Service 22DID 1193
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 65.535)
Range
0 to 1000 ms
Unit
ms

In testing for 1988 to 1996, 2000 to 2020.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2011. Supported for 1996, 2007, 2013 to 2014, 2016 to 2020.

Intake air temperature 2 IMPALA_IAT_2

  • Request22 15 38
  • Service 22DID 1538
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1996, 2000 to 2020.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2011. Supported for 2007, 2013 to 2014, 2016 to 2020.

Knock retard IMPALA_KNOCK_RETARDConfirmed

  • Request22 11 A6
  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 22 ÷ 100) = 0 °

Formula
(val × 22 ÷ 100)
Range
0 to 56.1 °
Unit
°

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Knock retard, alternate IMPALA_KNOCK_RETARD_ALT

  • Request22 12 5D
  • Service 22DID 125D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 1988 to 1996, 2000 to 2020.

Knock sensor active counter IMPALA_KNOCK_SENS_ACTIVE

  • Request22 12 5E
  • Service 22DID 125E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Last shift time IMPALA_LAST_SHIFT_TIME

  • Request22 19 92
  • Service 22DID 1992
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1988 to 1996, 2000 to 2020.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2011. Supported for 1996, 2007, 2013 to 2014, 2016 to 2020.

Mass airflow sensor IMPALA_MAFConfirmed

Pelican can show this parameter as the mass air flow.

  • Request22 00 10
  • Service 22DID 0010
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2020

Example reply from a 2017 Chevrolet Impala.

Bits 0 to 15 of the reply, 16 bits.

0x017B = 379 → (379 × 100 ÷ 10000) = 3.79 g/s

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2017. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2020.

MIL cause IMPALA_MIL_CAUSE

  • Request22 13 5F
  • Service 22DID 135F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

MIL status IMPALA_MIL_STAT

  • Request22 20 20
  • Service 22DID 2020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Misfire history, cylinder 1 IMPALA_MIS_HISTORY_1

  • Request22 12 01
  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Misfire history, cylinder 2 IMPALA_MIS_HISTORY_2

  • Request22 12 02
  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Misfire history, cylinder 3 IMPALA_MIS_HISTORY_3

  • Request22 12 03
  • Service 22DID 1203
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Misfire history, cylinder 4 IMPALA_MIS_HISTORY_4

  • Request22 12 04
  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Misfire history, cylinder 5 IMPALA_MIS_HISTORY_5

  • Request22 11 F8
  • Service 22DID 11F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Misfire history, cylinder 6 IMPALA_MIS_HISTORY_6

  • Request22 11 F9
  • Service 22DID 11F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1996, 2000 to 2020.

Misfires, current, cylinder 1 IMPALA_MISFIRES_C1_CURConfirmed

  • Request22 12 06
  • Service 22DID 1206
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Misfires, current, cylinder 2 IMPALA_MISFIRES_C2_CURConfirmed

  • Request22 12 05
  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Misfires, current, cylinder 3 IMPALA_MISFIRES_C3_CURConfirmed

  • Request22 12 07
  • Service 22DID 1207
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Misfires, current, cylinder 4 IMPALA_MISFIRES_C4_CURConfirmed

  • Request22 12 08
  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Misfires, current, cylinder 5 IMPALA_MISFIRES_C5_CURConfirmed

  • Request22 11 EA
  • Service 22DID 11EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Misfires, current, cylinder 6 IMPALA_MISFIRES_C6_CURConfirmed

  • Request22 11 EB
  • Service 22DID 11EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Outside air temperature IMPALA_AAT

  • Request22 11 61
  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1996, 2000 to 2020.

Pressure control solenoid current, actual IMPALA_P_CTRL_SOLENOID_ACT

  • Request22 19 9E
  • Service 22DID 199E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1988 to 1996, 2000 to 2020.

Pressure control solenoid current, reference IMPALA_P_CTRL_SOLENOID

  • Request22 19 9F
  • Service 22DID 199F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1988 to 1996, 2000 to 2020.

Remaining oil life IMPALA_REMAINING_OIL_LIFE

  • Request22 11 9F
  • Service 22DID 119F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1988 to 1996, 2000 to 2020.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2007, 2011, 2013, 2017. Supported for 1996, 2014, 2016, 2018 to 2020.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 08
  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2013, 2017. Supported for 1996, 2014, 2016, 2018 to 2020.

Throttle position calculated IMPALA_THROTTLE_POS_CALC

  • Request22 28 10
  • Service 22DID 2810
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1996, 2000 to 2020.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2011. Supported for 1996, 2007, 2013 to 2014, 2016 to 2020.

Total knock retard IMPALA_TOTAL_KNOCK_RETARDConfirmed

  • Request22 12 D9
  • Service 22DID 12D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 45 ÷ 100) = 0 °

Formula
(val × 45 ÷ 100)
Range
0 to 114.75 °
Unit
°

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Total misfire IMPALA_TOTAL_MISFIREConfirmed

  • Request22 12 00
  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017, 2020. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019.

Transmission fluid temperature IMPALA_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 19 40
  • Service 22DID 1940
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 1988 to 1996, 2000 to 2016, 2018 to 2019

Example reply from a 2017 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x77 = 119 → (119 − 40) = 79 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017. In testing for 1988 to 1996, 2000 to 2016, 2018 to 2019. Supported for 2020.

Transmission fluid temperature, variant 1 IMPALA_ATF_T_VAR_1Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 19 40
  • Service 22DID 1940
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 1996, 2000 to 2019

Example reply from a 2020 Chevrolet Impala.

Bits 0 to 7 of the reply, 8 bits.

0x75 = 117 → (117 − 40) = 77 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020. In testing for 1988 to 1996, 2000 to 2019.

Transmission fluid temperature, variant 6 IMPALA_ATF_T_VAR_6

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 28 0D
  • Service 22DID 280D
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1996, 2000 to 2020.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007. Supported for 1996, 2011, 2013 to 2014, 2016 to 2020.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007. Supported for 1996, 2011, 2013 to 2014, 2016 to 2020.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007. Supported for 1996, 2011, 2013 to 2014, 2016 to 2020.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007. Supported for 1996, 2011, 2013 to 2014, 2016 to 2020.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007. Supported for 1996, 2011, 2013 to 2014, 2016 to 2020.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007. Supported for 1996, 2011, 2013 to 2014, 2016 to 2020.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007. Supported for 1996, 2011, 2013 to 2014, 2016 to 2020.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2007. Supported for 1996, 2011, 2013 to 2014, 2016 to 2020.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.