Engine parameters
The Dodge Charger has 74 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2011, 2026.
Air conditioning high side pressure CHARGER_AC_HIGH_SIDE_P
- Request
22 03 29 - Service 22
DID 0329 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 14)- Range
- 0 to 3570 kPa
- Unit
- kPa
In testing for 2006 to 2023.
Air conditioning high side pressure CHARGER_AC_HIGH_SIDE_P_7E0
- Request
21 A7 - Service 21
PID A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 55)- Range
- 0 to 1191 psi
- Unit
- psi
In testing for 2006 to 2018.
Ambient air temperature CHARGER_AAT_7E0
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2006 to 2018.
Ambient temperature CHARGER_AAT
- Request
22 01 27 - Service 22
DID 0127 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
In testing for 2006 to 2023.
Automatic transmission fluid temperature CHARGER_ATF_T_3RDGEN_V2Confirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 5C - Service 21
PID 5C - Module
7E1 → 7E9 - Every
1 s - Testing for 2007 to 2026
Example reply from a 2006 Dodge Charger.
Bits 32 to 39 of the reply, 8 bits.
0x4A = 74 → (74 − 50) = 24 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2006. In testing for 2007 to 2012, 2014. Not supported for 2013, 2015, 2018 to 2019, 2026.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Barometric pressure CHARGER_BAROMETRIC_P
- Request
22 01 09 - Service 22
DID 0109 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 2006 to 2023.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2006, 2018 to 2019, 2026. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023.
Catalyst modeled temperature CHARGER_CAT_MODEL_T
- Request
22 01 2B - Service 22
DID 012B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 1000 °C
- Unit
- °C
In testing for 2006 to 2023.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed
- Request
01 3D - Service 01
PID 3D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2018 to 2019. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2006, 2018 to 2019, 2026.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018 to 2019.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2006, 2018 to 2019, 2026. Supported for 2011 to 2013, 2015 to 2017, 2021, 2023.
Engine oil pressure CHARGER_EOP
- Request
22 02 2A - Service 22
DID 022A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 29 ÷ 50)- Range
- 0 to 147.8999 psi
- Unit
- psi
In testing for 2006 to 2023.
Engine oil temperature CHARGER_EOT_212D
Pelican can show this parameter as the engine oil temperature.
- Request
21 2D - Service 21
PID 2D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
In testing for 2006 to 2023.
Engine operational status CHARGER_ENGINE_STATUSConfirmed
- Request
22 10 02 - Service 22
DID 1002 - Module
DA10 → 10 - Every
30 s - Testing for 2006 to 2025
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2026. In testing for 2007 to 2017, 2020 to 2025. Not supported for 2006, 2018 to 2019.
Engine RPM CHARGER_RPM_ECUConfirmed
- Request
22 10 00 - Service 22
DID 1000 - Module
DA10 → 10 - Every
1 s - Testing for 2006 to 2025
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 rpm
- Unit
- rpm
Confirmed for 2026. In testing for 2007 to 2017, 2020 to 2025. Not supported for 2006, 2018 to 2019.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Request
01 32 - Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4000)- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2018 to 2019. Supported for 2012 to 2013, 2015 to 2017, 2021, 2023, 2026.
Exhaust camshaft 1 to crankshaft offset CHARGER_EXH_CAM_1_OFFSET
- Request
22 06 1B - Service 22
DID 061B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2006 to 2018.
Fuel pressure FPSAE J1979Confirmed
- Request
01 0A - Service 01
PID 0A - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 3)- Range
- 0 to 765 kPa
- Unit
- kPa
Confirmed for 2019. Supported for 2018, 2021, 2026.
Injector pulse width, cylinder 1 CHARGER_INJ_WIDTH_CYL_1
- Request
22 02 34 - Service 22
DID 0234 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2006 to 2023.
Injector pulse width, cylinder 2 CHARGER_INJ_WIDTH_CYL_2
- Request
22 02 35 - Service 22
DID 0235 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2006 to 2023.
Injector pulse width, cylinder 3 CHARGER_INJ_WIDTH_CYL_3
- Request
22 02 36 - Service 22
DID 0236 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2006 to 2023.
Injector pulse width, cylinder 4 CHARGER_INJ_WIDTH_CYL_4
- Request
22 02 37 - Service 22
DID 0237 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 2006 to 2023.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019.
Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019.
Intake air temperature, bank 1, sensor 3 IAT_13SAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019.
Intake camshaft 1 to crankshaft offset CHARGER_INT_CAM_1_OFFSET
- Request
22 06 C2 - Service 22
DID 06C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 2006 to 2023.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Intake manifold air pressure CHARGER_MAP
- Request
22 01 74 - Service 22
DID 0174 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 2006 to 2023.
Intake manifold air temperature CHARGER_IAT_01FF
- Request
22 01 FF - Service 22
DID 01FF - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 2006 to 2023.
Intake manifold air temperature CHARGER_IAT_1935
- Request
22 19 35 - Service 22
DID 1935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 40)- Range
- -40 to 65495 °F
- Unit
- °F
In testing for 2006 to 2018.
Intake manifold air temperature CHARGER_IAT_70B8
- Request
22 70 B8 - Service 22
DID 70B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0198412698 − 40)- Range
- -40 to 1260.2976 °C
- Unit
- °C
In testing for 2006 to 2018.
Knock sensor 1 CHARGER_KNOCK_SENS_1
- Request
22 01 A9 - Service 22
DID 01A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 2006 to 2023.
Knock sensor 2 CHARGER_KNOCK_SENS_2
- Request
22 01 AA - Service 22
DID 01AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 2006 to 2023.
Line pressure CHARGER_LINE_P
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 2006 to 2018.
Line pressure duty cycle CHARGER_LINE_P_DUTY
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 655)- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2018.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed
- Request
01 09 - Service 01
PID 09 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Multi-displacement system active CHARGER_MDS_ACTIVE
- Request
22 0E CA - Service 22
DID 0ECA - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2023.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 08 - Service 01
PID 08 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Short term knock retard CHARGER_SHORT_TERM_KNOCK
- Request
22 01 AE - Service 22
DID 01AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 °
- Unit
- °
In testing for 2006 to 2018.
Throttle inlet air temperature filtered CHARGER_THROTTLE_INLET_AIR_T
- Request
22 14 B1 - Service 22
DID 14B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 2006 to 2023.
Throttle inlet pressure CHARGER_THROTTLE_INLET_P
- Request
22 12 47 - Service 22
DID 1247 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 160)- Range
- 0 to 409.5937 kPa
- Unit
- kPa
In testing for 2006 to 2023.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2018 to 2019. Supported for 2006, 2011 to 2013, 2015 to 2017, 2021, 2023, 2026.
Transmission main cylinder pressure CHARGER_MAIN_CYL_P
- Request
22 50 34 - Service 22
DID 5034 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513 bar
- Unit
- bar
In testing for 2006 to 2023.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2018 to 2019.
Variable valve timing oil pressure CHARGER_VARIABLE_VLV_TIM_OIL_P
- Request
22 06 9E - Service 22
DID 069E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 2006 to 2023.
Variable valve timing oil temperature CHARGER_VARIABLE_VLV_TIM_OIL_T
- Request
22 06 9F - Service 22
DID 069F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 2006 to 2023.
Engine › Internal
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018, 2026.
O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2019. Supported for 2006, 2011 to 2013, 2015 to 2018, 2021, 2023, 2026.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2018, 2026.