Ford E-Series Wagon

FORD_VCT_INT parameters

The Ford E-Series Wagon has 4 FORD_VCT_INT parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Variable camshaft timing intake cam desired FORD_VCT_INT_DES

  • Request22 03 BC
  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2047 to 2047 °
Unit
°

In testing for 1988 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Variable camshaft timing intake cam desired FORD_VCT_INT_DES

  • Request22 03 BC
  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2047 to 2047 °
Unit
°

In testing for 1988 to 2026.

Variable camshaft timing intake camshaft actual FORD_VCT_INT_ACT

  • Request22 03 18
  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 0 °
Unit
°

In testing for 1988 to 2026.

Variable camshaft timing intake camshaft error FORD_VCT_INT_ERR

  • Request22 03 1A
  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-50 to 50 °
Unit
°

In testing for 1988 to 2026.

Variable camshaft timing intake camshaft solenoid duty cycle FORD_VCT_INT_DUTY

  • Request22 03 16
  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0030517578)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.