Ford Explorer

EXPLORER_TIP parameters

The Ford Explorer has 2 EXPLORER_TIP parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Throttle inlet pressure absolute EXPLORER_TIP_ABSConfirmed

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0
  • Every250 ms
  • Testing for 1990 to 2012, 2014 to 2015, 2019, 2024

Example reply from a 2026 Ford Explorer.

Bits 0 to 15 of the reply, 16 bits.

0x314F = 12623 → (12623 × 0.0011064263) = 13.966419 psi

Formula
(val × 0.0011064263)
Range
0 to 60 psi
Unit
psi

Confirmed for 2013, 2016 to 2018, 2020 to 2023, 2025 to 2026. In testing for 1990 to 2004, 2006 to 2007, 2009 to 2010, 2012, 2014. Not supported for 2005, 2008, 2011, 2015, 2019, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Throttle inlet pressure absolute EXPLORER_TIP_ABSConfirmed

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0
  • Every250 ms
  • Testing for 1990 to 2012, 2014 to 2015, 2019, 2024

Example reply from a 2026 Ford Explorer.

Bits 0 to 15 of the reply, 16 bits.

0x314F = 12623 → (12623 × 0.0011064263) = 13.966419 psi

Formula
(val × 0.0011064263)
Range
0 to 60 psi
Unit
psi

Confirmed for 2013, 2016 to 2018, 2020 to 2023, 2025 to 2026. In testing for 1990 to 2004, 2006 to 2007, 2009 to 2010, 2012, 2014. Not supported for 2005, 2008, 2011, 2015, 2019, 2024.

Throttle inlet pressure sensor voltage EXPLORER_TIP_VConfirmed

  • Request22 03 3C
  • Service 22DID 033C
  • Module7E0
  • Every250 ms
  • Testing for 1990 to 2012, 2014 to 2015, 2019, 2024

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0048828125)
Range
0 to 5 V
Unit
V

Confirmed for 2013, 2016 to 2018, 2020 to 2023, 2025 to 2026. In testing for 1990 to 2004, 2006 to 2007, 2009 to 2010, 2012, 2014. Not supported for 2005, 2008, 2011, 2015, 2019, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.