Ford Ranger

Engine parameters

The Ford Ranger has 204 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Accelerator position RANGER_ACC_POSConfirmed

  • Request22 03 2B
  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2022, 2024. Supported for 2009, 2019, 2021, 2023, 2025 to 2026.

Accelerator position RANGER_ACC_POSConfirmed

  • Request22 03 2B
  • Service 22DID 032B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0 %

Formula
(val ÷ 2)
Range
0 to 100 %
Unit
%

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Actual EGR A duty cycle/position EGR_A_ACTSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Actual EGR B duty cycle/position EGR_B_ACTSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Actual engine percent torque RANGER_PCM_ACT_ENG_PCT_TRQConfirmed

  • Request22 F4 62
  • Service 22DID F462
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x7D = 125 → (125 − 125) = 0 %

Formula
(val − 125)
Range
0 to 100 %
Unit
%

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Actual engine torque TQ_ACTSAE J1979Confirmed

  • Request01 62
  • Service 01PID 62
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2020, 2024. Supported for 2019, 2021 to 2023, 2025.

Air conditioning pressure RANGER_AC_P_7E0Confirmed

  • Request22 FD 18
  • Service 22DID FD18
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 12.156863) = 0 kPa

Formula
(val × 12.156863)
Range
0 to 3100 kPa
Unit
kPa

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2012 to 2014, 2018, 2020 to 2021, 2024 to 2025. Supported for 2006, 2009, 2011, 2019, 2022 to 2023.

Alternator current output RANGER_ALTERNATOR_CURRENT

  • Request22 D1 13
  • Service 22DID D113
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3276 A
Unit
A

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2013 to 2014, 2020, 2024. Supported for 2009, 2011 to 2012, 2018 to 2019, 2021 to 2023, 2025 to 2026.

Barometric pressure RANGER_BAROConfirmed

  • Request22 03 53
  • Service 22DID 0353
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x018A = 394 → (394 × 615 ÷ 16963) = 14.284619 psi

Formula
(val × 615 ÷ 16963)
Range
8 to 20 psi
Unit
psi

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Barometric pressure RANGER_BAROMETRIC_P

  • Request22 11 27
  • Service 22DID 1127
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 338639 ÷ 80000)
Range
0 to 1079.4118 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Barometric pressure sensor voltage RANGER_BARO_VConfirmed

  • Request22 03 5A
  • Service 22DID 035A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Battery current RANGER_BAT_CURRENT_726

  • Request22 40 90
  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 511.7)
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Boost RANGER_BOOST

  • Request22 14 40
  • Service 22DID 1440
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 psi
Unit
psi

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Bypass valve RANGER_BPV_OPENConfirmed

  • Request22 04 27
  • Service 22DID 0427
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 255) = 0

Formula
(val ÷ 255)
Range
0 to 1
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2012 to 2014, 2018 to 2022, 2024 to 2026. Supported for 2006, 2009, 2011, 2023.

Camshaft position error, exhaust RANGER_VCT_EXH_ERRConfirmed

  • Request22 03 1B
  • Service 22DID 031B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
0 to 50 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position error, intake RANGER_VCT_INT_ERRConfirmed

  • Request22 03 1A
  • Service 22DID 031A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-50 to 50 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position, exhaust actual RANGER_VCT_EXH_ACTConfirmed

  • Request22 03 19
  • Service 22DID 0319
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
0 to 50 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position, exhaust desired RANGER_VCT_EXH_DESConfirmed

  • Request22 03 BB
  • Service 22DID 03BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-2047 to 2047 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position, intake actual RANGER_VCT_INT_ACTConfirmed

  • Request22 03 18
  • Service 22DID 0318
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-2048 to 2047.93 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft position, intake desired RANGER_VCT_INT_DESConfirmed

  • Request22 03 BC
  • Service 22DID 03BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 16) = 0 °

Formula
(val ÷ 16)
Range
-2047 to 2047 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft solenoid duty cycle, exhaust RANGER_VCT_EXH_DUTYConfirmed

  • Request22 03 17
  • Service 22DID 0317
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 25 ÷ 8192) = 0 %

Formula
(val × 25 ÷ 8192)
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Camshaft solenoid duty cycle, intake RANGER_VCT_INT_DUTYConfirmed

  • Request22 03 16
  • Service 22DID 0316
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 25 ÷ 8192) = 0 %

Formula
(val × 25 ÷ 8192)
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Catalyst temperature RANGER_CAT_TEMPConfirmed

  • Request22 F4 3C
  • Service 22DID F43C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x100B = 4107 → (4107 ÷ 10 − 40) = 370.7 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020. Supported for 2009, 2018 to 2019, 2021 to 2026.

Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed

  • Request01 3E
  • Service 01PID 3E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020. Supported for 2018 to 2019, 2021 to 2022.

Charge air temperature RANGER_CATConfirmed

  • Request22 04 61
  • Service 22DID 0461
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x04FE = 1278 → (1278 ÷ 64 − 40) = -20.03125 °C

Formula
(val ÷ 64 − 40)
Range
-40 to 189 °C
Unit
°C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Charge air temperature sensor voltage RANGER_CAT_SENS_V

  • Request22 04 60
  • Service 22DID 0460
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2024.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Request01 2C
  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013 to 2014, 2020. Supported for 2009, 2011 to 2012, 2018 to 2019, 2021 to 2022.

Commanded EGR A duty cycle/position EGR_A_CMDSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Commanded EGR B duty cycle/position EGR_B_CMDSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2019, 2022, 2024 to 2026. Supported for 2021, 2023.

Commanded generator duty RANGER_CMD_GEN_DUTY

  • Request22 16 E8
  • Service 22DID 16E8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.003052)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013 to 2014, 2020. Supported for 2011 to 2012, 2018 to 2019, 2021 to 2022.

Coolant temperature RANGER_ECTConfirmed

  • Request22 03 8F
  • Service 22DID 038F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x082E = 2094 → (2094 ÷ 64) = 32.71875 °C

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Current gear RANGER_GEARConfirmed

The automatic transmission gear. Numbers aren't yet mapped to named gears.

  • Request22 1E 12
  • Service 22DID 1E12
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014, 2018 to 2021, 2023 to 2025. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017, 2022, 2026. Not supported for 2006, 2008, 2012 to 2013.

Cylinder 1 misfire count RANGER_MIS_CNT_1

  • Request22 16 0E
  • Service 22DID 160E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 2 misfire count RANGER_MIS_CNT_2

  • Request22 16 0F
  • Service 22DID 160F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 3 misfire count RANGER_MIS_CNT_3

  • Request22 16 10
  • Service 22DID 1610
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 4 misfire count RANGER_MIS_CNT_4

  • Request22 16 11
  • Service 22DID 1611
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 5 misfire count RANGER_MIS_CNT_5

  • Request22 16 12
  • Service 22DID 1612
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 6 misfire count RANGER_MIS_CNT_6

  • Request22 16 13
  • Service 22DID 1613
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 7 misfire count RANGER_MIS_CNT_7

  • Request22 16 14
  • Service 22DID 1614
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder 8 misfire count RANGER_MIS_CNT_8

  • Request22 16 15
  • Service 22DID 1615
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder head temperature RANGER_CYL_HEAD_T

  • Request22 05 1D
  • Service 22DID 051D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder head temperature RANGER_CYL_HEAD_T_7E0

  • Request22 16 24
  • Service 22DID 1624
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder head temperature RANGER_PCM_CYL_HEAD_T_CORRConfirmed

  • Request22 03 34
  • Service 22DID 0334
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x067F = 1663 → (1663 ÷ 64) = 25.984375 °C

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Cylinder head temperature, alternate RANGER_CYL_HEAD_T_ALT

  • Request22 16 85
  • Service 22DID 1685
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 281 ÷ 1000)
Range
0 to 18415 °F
Unit
°F

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Cylinder head temperature, sensor 2 RANGER_PCM_CYL_HEAD_T_SENS_2_RAWConfirmed

  • Request22 05 FC
  • Service 22DID 05FC
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0B66 = 2918 → (2918 ÷ 64) = 45.59375 °C

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Distance since DTC clear RANGER_DIST_DTC_CLRConfirmed

  • Request22 F4 31
  • Service 22DID F431
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x142A = 5162 → 5,162 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Distance with MIL RANGER_MIL_DISTConfirmed

  • Request22 F4 21
  • Service 22DID F421
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Driver's demand engine torque TQ_DDSAE J1979Confirmed

  • Request01 61
  • Service 01PID 61
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2020. Supported for 2019, 2021 to 2025.

EGR A error EGR_A_ERRSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024.

EGR B error EGR_B_ERRSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2024.

EGR error EGR_ERRSAE J1979Confirmed

  • Request01 2D
  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2013 to 2014, 2020. Supported for 2011 to 2012, 2018 to 2019, 2021 to 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012 to 2014, 2018 to 2022, 2024 to 2026. Supported for 2006, 2009, 2011, 2023.

Engine Friction - Percent Torque TQ_FRSAE J1979Confirmed

  • Request01 8E
  • Service 01PID 8E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2020.

Engine load RANGER_ENG_LOAD_PCTConfirmed

  • Request22 F4 04
  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Engine load, actual RANGER_ENG_LOAD_ACTConfirmed

  • Request22 F4 43
  • Service 22DID F443
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Engine oil pressure RANGER_EOPConfirmed

  • Request22 F4 5C
  • Service 22DID F45C
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014, 2018. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Supported for 2021. Not supported for 2006, 2008, 2012 to 2013, 2019, 2024.

Engine oil pressure - desired RANGER_EOP_DES

  • Request22 05 EF
  • Service 22DID 05EF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Engine oil temperature EOTSAE J1979Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request01 5C
  • Service 01PID 5C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 210 °C
Unit
°C

Confirmed for 2020. Supported for 2019, 2021 to 2024.

Engine oil temperature RANGER_EOTConfirmed

  • Request22 13 10
  • Service 22DID 1310
  • Module7DF
  • Every30 s
  • Testing

Example reply from a 2014 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x12 = 18 → 18

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2012 to 2014. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017, 2020, 2023, 2025 to 2026. Not supported for 2006, 2008, 2018 to 2019, 2021 to 2022, 2024.

Engine reference torque RANGER_PCM_ENG_REFERENCE_TRQConfirmed

  • Request22 F4 63
  • Service 22DID F463
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x02B2 = 690 → 690 N·m

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Engine reference torque TQ_REFSAE J1979Confirmed

  • Request01 63
  • Service 01PID 63
  • Module7E0 → 7E8
  • Every86400 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

Confirmed for 2020. Supported for 2019, 2021, 2023 to 2025.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2013 to 2014, 2018, 2020, 2022, 2024. Supported for 2006, 2009, 2011 to 2012, 2019, 2021, 2023, 2025 to 2026.

Engine run time RANGER_ERT

  • Request22 11 26
  • Service 22DID 1126
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021 to 2022, 2024.

Engine speed RANGER_RPMConfirmed

  • Request22 F4 0C
  • Service 22DID F40C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 4) = 0 rpm

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Evaporative pressure sensor voltage RANGER_EVAP_VConfirmed

  • Request22 03 8E
  • Service 22DID 038E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x078B = 1931 → (1931 ÷ 1000) = 1.931 V

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Evaporative purge RANGER_EVAP_PURGE_CMDConfirmed

  • Request22 11 66
  • Service 22DID 1166
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 100 ÷ 32768) = 0 %

Formula
(val × 100 ÷ 32768)
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Exhaust gas recirculation RANGER_EGR

  • Request22 F4 2C
  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust gas recirculation duty cycle RANGER_EGR_DUTY

  • Request22 11 3C
  • Service 22DID 113C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust gas recirculation open RANGER_EGR_OPEN

  • Request22 05 2E
  • Service 22DID 052E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTASAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2024.

Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTBSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2024.

Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTCSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2024.

Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTDSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020, 2024.

Exhaust gas recirculation temperature RANGER_EGR_T

  • Request22 05 43
  • Service 22DID 0543
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust gas temperature 1 RANGER_EXH_GAS_T_1

  • Request22 03 F4
  • Service 22DID 03F4
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5)
Range
0 to 1275 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust gas temperature 2 RANGER_EXH_GAS_T_2

  • Request22 03 F5
  • Service 22DID 03F5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5)
Range
0 to 1275 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel injection timing FUEL_TIMINGSAE J1979Confirmed

Start of main fuel injection relative to Top Dead Center (TDC). Positive degrees indicate before TDC, negative degrees indicate after TDC.

  • Request01 5D
  • Service 01PID 5D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 − 38665)
Range
-210 to 301.992 °
Unit
°

Confirmed for 2020. Supported for 2019, 2021 to 2025.

Fuel pressure sensor voltage, low RANGER_LPFP_SENS_VConfirmed

  • Request22 05 4D
  • Service 22DID 054D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel pressure, low actual RANGER_LPFP_ACTConfirmed

  • Request22 05 48
  • Service 22DID 0548
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0329 = 809 → (809 × 10000 ÷ 137892) = 58.669103 psi

Formula
(val × 10000 ÷ 137892)
Range
0 to 200 psi
Unit
psi

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel pressure, low desired RANGER_LPFP_DESConfirmed

  • Request22 04 1F
  • Service 22DID 041F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x9F = 159 → (159 × 435 ÷ 1000) = 69.165 psi

Formula
(val × 435 ÷ 1000)
Range
0 to 110 psi
Unit
psi

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel pump duty cycle, low pressure RANGER_LPFP_DUTYConfirmed

  • Request22 03 07
  • Service 22DID 0307
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x1953 = 6483 → (6483 × 25 ÷ 8192) = 19.784546 %

Formula
(val × 25 ÷ 8192)
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel pump pulse width, bank 2 RANGER_FUEL_PMP_WIDTH_BANK_2

  • Request22 11 42
  • Service 22DID 1142
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 23
  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2013 to 2014. Supported for 2011 to 2012, 2019, 2021 to 2026.

Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 59
  • Service 01PID 59
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2020. Supported for 2019, 2021 to 2025.

Fuel rail pressure, desired RANGER_HPFP_DESConfirmed

  • Request22 03 DC
  • Service 22DID 03DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0024 = 36 → (36 × 10) = 360 kPa

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Fuel rail sensor voltage, high pressure RANGER_HPFP_VConfirmed

  • Request22 03 24
  • Service 22DID 0324
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Fuel trim, long term RANGER_LTFTConfirmed

  • Request22 F4 07
  • Service 22DID F407
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x7B = 123 → (123 × 100 ÷ 128 − 100) = -3.90625 %

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Fuel trim, short term RANGER_STFTConfirmed

  • Request22 F4 06
  • Service 22DID F406
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x75 = 117 → (117 × 100 ÷ 128 − 100) = -8.59375 %

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Generator control RANGER_GEN_CTRL

  • Request22 03 78
  • Service 22DID 0378
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.003052)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Generator current RANGER_GEN_CURRENTConfirmed

  • Request22 04 F7
  • Service 22DID 04F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xF880 = -1920 → (-1920 × 781 ÷ 50000) = -29.9904 A

Formula
(val × 781 ÷ 50000)
Range
-511.8361 to 511.8205 A
Unit
A

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Grill shutter duty cycle RANGER_GRILL_SHUT_DCConfirmed

  • Request22 07 07
  • Service 22DID 0707
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Grill shutter position RANGER_GRILL_SHUTTER_POSConfirmed

  • Request22 05 80
  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Ignition correction, cylinder 1 RANGER_IGN_CORR_CYL1Confirmed

  • Request22 03 EC
  • Service 22DID 03EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 512) = 0 °

Formula
(val ÷ 512)
Range
-64 to 63.9 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Ignition timing, cylinder 1 RANGER_IGN_TIM_CYL1Confirmed

  • Request22 11 6B
  • Service 22DID 116B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0004 = 4 → (4 ÷ 4) = 1 °

Formula
(val ÷ 4)
Range
-80 to 80 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

In car temperature RANGER_CAR_T

  • Request22 DD 04
  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 8)
Range
0 to 31.875 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Injection mode RANGER_INJ_MODEConfirmed

  • Request22 04 6F
  • Service 22DID 046F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x07 = 7 → 7

Formula
val
Range
0 to 7
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Injector impulse width RANGER_INJ_IMPULSE_WIDTH

  • Request22 11 41
  • Service 22DID 1141
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000022)
Range
0 to 0.05 s
Unit
s

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013 to 2014. Supported for 2006, 2009, 2011 to 2012, 2018 to 2026.

Intake air temperature 2 RANGER_IAT_2

  • Request22 16 A8
  • Service 22DID 16A8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 9 − 17.777778)
Range
-17.77 to 36390 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2013 to 2014, 2020. Supported for 2009, 2011 to 2012, 2018 to 2019, 2021 to 2026.

Intake temperature fault RANGER_IAT_FAULTConfirmed

  • Request22 07 00
  • Service 22DID 0700
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Intake temperature sensor voltage RANGER_IAT_SENS_VConfirmed

  • Request22 12 79
  • Service 22DID 1279
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0174 = 372 → (372 × 5 ÷ 1023) = 1.818182 V

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Intake temperature, alternate RANGER_IAT_ALT2Confirmed

  • Request22 F4 0F
  • Service 22DID F40F
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x3F = 63 → (63 − 40) = 23 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Knock counter, cylinder 1 RANGER_PCM_CYL_1_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 AC
  • Service 22DID 05AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 2 RANGER_PCM_CYL_2_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 AD
  • Service 22DID 05AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x02 = 2 → 2

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 3 RANGER_PCM_CYL_3_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 AE
  • Service 22DID 05AE
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 4 RANGER_PCM_CYL_4_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 AF
  • Service 22DID 05AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 5 RANGER_PCM_CYL_5_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 B0
  • Service 22DID 05B0
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock counter, cylinder 6 RANGER_PCM_CYL_6_KNK_COMB_PERF_CNTConfirmed

  • Request22 05 B1
  • Service 22DID 05B1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock sensor, 1 RANGER_KS1_RAWConfirmed

  • Request22 04 03
  • Service 22DID 0403
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0017 = 23 → 23

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Knock sensor, 2 RANGER_KS2_RAWConfirmed

  • Request22 04 04
  • Service 22DID 0404
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0013 = 19 → 19

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Lambda correction RANGER_CL_LCConfirmed

  • Request22 03 BD
  • Service 22DID 03BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 8192) = 0

Formula
(val ÷ 8192)
Range
-4 to 3.9
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Lambda, commanded RANGER_CLConfirmed

The ratio of oxygen in the combustion chamber compared to the amount that should have been present for ideal combustion.

  • Request22 03 0F
  • Service 22DID 030F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x5536 = 21814 → (21814 ÷ 32768) = 0.66571

Formula
(val ÷ 32768)
Range
0 to 1.9999
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Manifold absolute pressure, high resolution RANGER_MAP_HIRESConfirmed

  • Request22 03 70
  • Service 22DID 0370
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0054 = 84 → (84 ÷ 4) = 21 kPa

Formula
(val ÷ 4)
Range
0 to 16383.75 kPa
Unit
kPa

Confirmed for 2022, 2024. In testing for 2019 to 2021, 2023, 2025 to 2026.

Manifold pressure RANGER_MAPConfirmed

  • Request22 F4 0B
  • Service 22DID F40B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10000 ÷ 68947)
Range
0 to 36 psi
Unit
psi

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Manifold pressure sensor voltage RANGER_MAP_VConfirmed

Typically varies from 1 volt at idle to 5 volts during wide open throttle.

  • Request22 03 01
  • Service 22DID 0301
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Manifold temperature RANGER_MCTConfirmed

  • Request22 03 CA
  • Service 22DID 03CA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x3E = 62 → 62 °C

Formula
val
Range
0 to 148.889 °C
Unit
°C

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Mass Air Flow Sensor A MAFASAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2018, 2020, 2024 to 2025.

Mass Air Flow Sensor B MAFBSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 g/s
Unit
g/s

Confirmed for 2018, 2020, 2024 to 2025.

Misfire acceleration, cylinder 1 RANGER_PCM_MISF_ACCEL_CYL1_NORMConfirmed

  • Request22 03 82
  • Service 22DID 0382
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 2 RANGER_PCM_MISF_ACCEL_CYL2_NORMConfirmed

  • Request22 03 88
  • Service 22DID 0388
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 3 RANGER_PCM_MISF_ACCEL_CYL3_NORMConfirmed

  • Request22 03 8A
  • Service 22DID 038A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 4 RANGER_PCM_MISF_ACCEL_CYL4_NORMConfirmed

  • Request22 03 8B
  • Service 22DID 038B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 5 RANGER_PCM_MISF_ACCEL_CYL5_NORMConfirmed

  • Request22 03 8C
  • Service 22DID 038C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire acceleration, cylinder 6 RANGER_PCM_MISF_ACCEL_CYL6_NORMConfirmed

  • Request22 03 98
  • Service 22DID 0398
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 64) = 0

Formula
(val ÷ 64)
Range
-2 to 1.98
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Misfire events, latest cycle RANGER_PCM_MISF_EVENTS_LATEST_CYCConfirmed

  • Request22 03 45
  • Service 22DID 0345
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 31 of the reply, 32 bits.

0x00000001 = 1 → 1

Formula
val
Range
0 to 4294967295
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Navigation altitude RANGER_SYNC_GPS_ALTITUDE

  • Request22 80 12
  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Navigation heading RANGER_SYNC_GPS_HEADING

  • Request22 80 12
  • Service 22DID 8012
  • Module7D0 → 7D8
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °
Unit
°

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

O2 sensor voltage, rear RANGER_RO2_VConfirmed

  • Request22 03 5F
  • Service 22DID 035F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 1 V
Unit
V

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Octane adjustment RANGER_OARConfirmed

  • Request22 03 E8
  • Service 22DID 03E8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16384)
Range
0 to 1
Unit
Number

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Oil life remaining RANGER_PCM_ENG_OIL_LIFE_REMConfirmed

  • Request22 05 4B
  • Service 22DID 054B
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x40 = 64 → 64 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Oil pressure RANGER_PCM_ENG_EOP_RAWConfirmed

  • Request22 04 15
  • Service 22DID 0415
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0062 = 98 → 98 kPa

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Shift gear RANGER_GEAR_SHFTConfirmed

  • Request22 1E 23
  • Service 22DID 1E23
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014, 2018. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017, 2019, 2021 to 2026. Not supported for 2006, 2008, 2012 to 2013, 2020.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2019, 2022, 2024 to 2025. Supported for 2006, 2009, 2021, 2023, 2026.

Sump oil temperature measured RANGER_SUMP_OIL_T_MEAS

  • Request22 03 F3
  • Service 22DID 03F3
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Throttle angle, actual RANGER_ETC_ANG_ACTConfirmed

  • Request22 09 3C
  • Service 22DID 093C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.99 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Throttle angle, desired RANGER_ETC_ANG_DESConfirmed

  • Request22 09 1A
  • Service 22DID 091A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.99 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Throttle control trim angle, learned RANGER_ETC_TRIM_LRNConfirmed

  • Request22 03 38
  • Service 22DID 0338
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 512) = 0 °

Formula
(val ÷ 512)
Range
-64 to 63.9 °
Unit
°

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Throttle inlet pressure RANGER_TIP_ABSConfirmed

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x3270 = 12912 → (12912 × 37 ÷ 33441) = 14.286176 psi

Formula
(val × 37 ÷ 33441)
Range
0 to 60 psi
Unit
psi

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Throttle inlet pressure sensor voltage RANGER_TIP_VConfirmed

  • Request22 03 3C
  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Throttle inlet pressure, desired RANGER_TIP_DES_ABSConfirmed

  • Request22 04 66
  • Service 22DID 0466
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x3143 = 12611 → (12611 × 37 ÷ 33441) = 13.953141 psi

Formula
(val × 37 ÷ 33441)
Range
0 to 72.5 psi
Unit
psi

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Time since last oil change RANGER_TIME_SINCE_OIL

  • Request22 05 3F
  • Service 22DID 053F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 200 ÷ 13107)
Range
0 to 1000
Unit
Raw value

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque converter slip RANGER_TQ_CONV_SLIP

  • Request22 11 B8
  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1.638538424)
Range
0 to 39996.0104 rpm
Unit
rpm

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque into torque converter RANGER_TQ_INTO_TQ_CONV

  • Request22 09 CB
  • Service 22DID 09CB
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1.35581795)
Range
0 to 48336.1353 N·m
Unit
N·m

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque into torque converter RANGER_TQ_INTO_TQ_CONV_7E0

  • Request22 16 3A
  • Service 22DID 163A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.2711635897)
Range
0 to 69.1467 N·m
Unit
N·m

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Torque request RANGER_TRQ_CTRL_REQConfirmed

  • Request22 03 AF
  • Service 22DID 03AF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 1988 to 2021, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026. Not supported for 2021.

Total Engine Run Time RUN_TIMESAE J1979Confirmed

  • Request01 7F
  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 39 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024.

Total Idle Run Time IDLE_TIMESAE J1979Confirmed

  • Request01 7F
  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 40 to 71 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024.

Total misfire count RANGER_TOT_MIS_CNT

  • Request22 16 16
  • Service 22DID 1616
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Total Run Time With PTO Active PTO_TIMESAE J1979Confirmed

  • Request01 7F
  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bits 72 to 103 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

Confirmed for 2024.

Transfer case fluid temperature RANGER_TRANSFER_CASE_FLUID_T

  • Request22 07 0D
  • Service 22DID 070D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 °C
Unit
°C

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission fluid temperature, variant 1 RANGER_ATF_T_VAR_1

  • Request22 16 74
  • Service 22DID 1674
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8)
Range
0 to 8191 °F
Unit
°F

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission fluid temperature, variant 6 RANGER_ATF_T_VAR_6

  • Request22 09 2C
  • Service 22DID 092C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °F
Unit
°F

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Transmission oil temperature RANGER_TOTConfirmed

  • Request22 1E 1C
  • Service 22DID 1E1C
  • Module7DF
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014, 2018 to 2019, 2021 to 2026. In testing for 2005, 2007, 2009 to 2011, 2015 to 2017. Not supported for 2006, 2008, 2012 to 2013, 2020.

Turbo boost RANGER_TURBO_BOOST

  • Request22 09 DB
  • Service 22DID 09DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Turbo inlet pressure RANGER_TURBO_INLET_P

  • Request22 05 BE
  • Service 22DID 05BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 kPa
Unit
kPa

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2020, 2024. Supported for 2018 to 2019, 2021 to 2023, 2025.

Warm-ups since DTC clear RANGER_WARMUP_CLRConfirmed

  • Request22 F4 30
  • Service 22DID F430
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 7 of the reply, 8 bits.

0x3C = 60 → 60

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Wastegate control RANGER_WASTEGATE_CTRL

  • Request22 16 E1
  • Service 22DID 16E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 763 ÷ 50000)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Wastegate duty cycle RANGER_WGDCConfirmed

  • Request22 04 62
  • Service 22DID 0462
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2020, 2023, 2025 to 2026

Example reply from a 2024 Ford Ranger.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 100 ÷ 32768) = 0 %

Formula
(val × 100 ÷ 32768)
Range
0 to 100 %
Unit
%

Confirmed for 2021 to 2022, 2024. In testing for 2019 to 2020, 2023, 2025 to 2026.

Engine › Internal

Actual EGR A supported EGR_A_ACT_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Actual EGR A supported EGR_B_ACT_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost bressure A control status BP_ASAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 78 to 79 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_A_OLOpen loop
2BP_A_CLClosed loop
3BP_A_FAULTFault

Confirmed for 2024.

Boost bressure A control status BP_BSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 76 to 77 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
1BP_B_OLOpen loop
2BP_B_CLClosed loop
3BP_B_FAULTFault

Confirmed for 2024.

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded EGR A supported EGR_A_CMD_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Commanded EGR A supported EGR_B_CMD_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR A error supported EGR_A_ERR_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR A error supported EGR_B_ERR_SUPSAE J1979Confirmed

  • Request01 69
  • Service 01PID 69
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUPSAE J1979Confirmed

  • Request01 6B
  • Service 01PID 6B
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2024.

Engine Percent Torque At Idle, Point 1 TQ_MAX1SAE J1979Confirmed

  • Request01 64
  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine Percent Torque At Point 2 TQ_MAX2SAE J1979Confirmed

  • Request01 64
  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine Percent Torque At Point 3 TQ_MAX3SAE J1979Confirmed

  • Request01 64
  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine Percent Torque At Point 4 TQ_MAX4SAE J1979Confirmed

  • Request01 64
  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

Engine Percent Torque At Point 5 TQ_MAX5SAE J1979Confirmed

  • Request01 64
  • Service 01PID 64
  • Module7E0 → 7E8
  • Every3600 s

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 125)
Range
-125 to 130 %
Unit
%

Confirmed for 2024.

MAF Sensor A supported MAFA_SUPSAE J1979Confirmed

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020, 2024 to 2025.

MAF Sensor B supported MAFB_SUPSAE J1979Confirmed

  • Request01 66
  • Service 01PID 66
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020, 2024 to 2025.

Total Engine Run Time supported? RUN_TIME_SUPSAE J1979Confirmed

  • Request01 7F
  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Total Idle Run Time supported? IDLE_TIME_SUPSAE J1979Confirmed

  • Request01 7F
  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Total Run Time With PTO Active supported? PTO_TIME_SUPSAE J1979Confirmed

  • Request01 7F
  • Service 01PID 7F
  • Module7E0 → 7E8
  • Every1 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2024.

Engine › OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2019, 2022, 2024 to 2026. Supported for 2021, 2023.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2019, 2022, 2024 to 2026. Supported for 2021, 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.