Front left tire pressure HOLDEN_TP_FL_2
Pelican can show this parameter as the front left tire pressure.
- Request
22 50 05 - Service 22
DID 5005 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Front left tire pressure HOLDEN_TP_FL_V3
Pelican can show this parameter as the front left tire pressure.
- Request
22 50 05 - Service 22
DID 5005 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Front left tire sensor ID HOLDEN_TID_FL
- Request
22 40 05 - Service 22
DID 4005 - Module
DA40 → 40 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 1988 to 2020.
Front left tire sensor ID HOLDEN_TID_FL_V2
- Request
22 40 05 - Service 22
DID 4005 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 1988 to 2020.
Front left wheel speed HOLDEN_FL_WHEEL_VSS
- Request
22 4A 7A - Service 22
DID 4A7A - Module
DA28 → 2AF128 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1988 to 2020.
Front right tire pressure HOLDEN_TP_FR_2
Pelican can show this parameter as the front right tire pressure.
- Request
22 50 06 - Service 22
DID 5006 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Front right tire pressure HOLDEN_TP_FR_V3
Pelican can show this parameter as the front right tire pressure.
- Request
22 50 06 - Service 22
DID 5006 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Front right tire sensor ID HOLDEN_TID_FR
- Request
22 40 06 - Service 22
DID 4006 - Module
DA40 → 40 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 1988 to 2020.
Front right tire sensor ID HOLDEN_TID_FR_V2
- Request
22 40 06 - Service 22
DID 4006 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 1988 to 2020.
Front right wheel speed HOLDEN_FR_WHEEL_VSS
- Request
22 4A 7A - Service 22
DID 4A7A - Module
DA28 → 2AF128 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1988 to 2020.
Left front tire pressure HOLDEN_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Request
22 24 8E - Service 22
DID 248E - Module
DA11 → 2AF111 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2005, 2007 to 2010, 2012 to 2017, 2019 to 2020. Not supported for 2006, 2011, 2018.
Left front tire pressure HOLDEN_TP_FL_V2
Pelican can show this parameter as the front left tire pressure.
- Request
22 24 8E - Service 22
DID 248E - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2020.
Left rear tire pressure HOLDEN_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Request
22 24 91 - Service 22
DID 2491 - Module
DA11 → 2AF111 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2005, 2007 to 2010, 2012 to 2017, 2019 to 2020. Not supported for 2006, 2011, 2018.
Left rear tire pressure HOLDEN_TP_RL_V2
Pelican can show this parameter as the rear left tire pressure.
- Request
22 24 91 - Service 22
DID 2491 - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2020.
Rear left tire pressure HOLDEN_TP_RL_2
Pelican can show this parameter as the rear left tire pressure.
- Request
22 50 08 - Service 22
DID 5008 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Rear left tire pressure HOLDEN_TP_RL_V3
Pelican can show this parameter as the rear left tire pressure.
- Request
22 50 08 - Service 22
DID 5008 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Rear left tire sensor ID HOLDEN_TID_RL
- Request
22 40 08 - Service 22
DID 4008 - Module
DA40 → 40 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 1988 to 2020.
Rear left tire sensor ID HOLDEN_TID_RL_V2
- Request
22 40 08 - Service 22
DID 4008 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 1988 to 2020.
Rear left wheel speed HOLDEN_RL_WHEEL_VSS
- Request
22 4A 7A - Service 22
DID 4A7A - Module
DA28 → 2AF128 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1988 to 2020.
Rear right tire pressure HOLDEN_TP_RR_2
Pelican can show this parameter as the rear right tire pressure.
- Request
22 50 07 - Service 22
DID 5007 - Module
DA40 → 40 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Rear right tire pressure HOLDEN_TP_RR_V3
Pelican can show this parameter as the rear right tire pressure.
- Request
22 50 07 - Service 22
DID 5007 - Module
241 → 641 - Every
15 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 2020.
Rear right tire sensor ID HOLDEN_TID_RR
- Request
22 40 07 - Service 22
DID 4007 - Module
DA40 → 40 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 1988 to 2020.
Rear right tire sensor ID HOLDEN_TID_RR_V2
- Request
22 40 07 - Service 22
DID 4007 - Module
241 → 641 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Hexadecimal
In testing for 1988 to 2020.
Rear right wheel speed HOLDEN_RR_WHEEL_VSS
- Request
22 4A 7A - Service 22
DID 4A7A - Module
DA28 → 2AF128 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1988 to 2020.
Right front tire pressure HOLDEN_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Request
22 24 8F - Service 22
DID 248F - Module
DA11 → 2AF111 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2005, 2007 to 2010, 2012 to 2017, 2019 to 2020. Not supported for 2006, 2011, 2018.
Right front tire pressure HOLDEN_TP_FR_V2
Pelican can show this parameter as the front right tire pressure.
- Request
22 24 8F - Service 22
DID 248F - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2020.
Right rear tire pressure HOLDEN_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Request
22 24 90 - Service 22
DID 2490 - Module
DA11 → 2AF111 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2005, 2007 to 2010, 2012 to 2017, 2019 to 2020. Not supported for 2006, 2011, 2018.
Right rear tire pressure HOLDEN_TP_RR_V2
Pelican can show this parameter as the rear right tire pressure.
- Request
22 24 90 - Service 22
DID 2490 - Module
7E0 → 7E8 - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 2020.