Honda CR-V Hybrid

Battery parameters

The Honda CR-V Hybrid has 197 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery coolant temperature CRVH_BATTERY_COOLANT_TEMPERATUREConfirmed

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 88 to 95 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery coolant temperature CRVH_BATTERY_COOLANT_TEMPERATUREConfirmed

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 88 to 95 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2026.

Battery module power CRVH_BATTERY_MODULE_POWERConfirmed

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 168 to 183 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 0.016) = 0 kW

Formula
(val × 0.016)
Range
-524.288 to 524.272 kW
Unit
kW

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2026.

Cell voltage limit during charge CRVH_CEL_V_LIM

  • Request22 20 29
  • Service 22DID 2029
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Charging voltage target CRVH_CHG_V_TGT

  • Request22 20 29
  • Service 22DID 2029
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Distance traveled since last charge CRVH_BAT_DIST

  • Request22 22 40
  • Service 22DID 2240
  • ModuleDA0E → 0E
  • Every30 s
  • Testing

Bits 80 to 111 of the reply, 32 bits.

Formula
val
Range
0 to 250000 km
Unit
km

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

High voltage battery cells, max state of charge CRVH_CELL_MAX_SOCConfirmed

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

High voltage battery cells, max state of charge CRVH_CELL_MIN_SOCConfirmed

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

High voltage battery module 1A temperature CRVH_HVB_MOD_1A_TConfirmed

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

High voltage battery module 1B temperature CRVH_HVB_MOD_1B_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

High voltage battery module 2A temperature CRVH_HVB_MOD_2A_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 488 to 503 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

High voltage battery module 3A temperature CRVH_HVB_MOD_3A_TConfirmed

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

High voltage battery module 3B temperature CRVH_HVB_MOD_3B_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

High voltage battery module 4B temperature CRVH_HVB_MOD_4B_T

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA16 → 16
  • Every5 s
  • Testing

Bits 520 to 535 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

High voltage battery total capacity CRVH_HVB_CAPConfirmed

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

High voltage battery total current CRVH_HVB_C_TOTALConfirmed

Pelican can show this parameter as the traction battery current.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-100 to 200 A
Unit
A

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

High voltage battery voltage CRVH_HVB_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

High voltage battery voltage, line B CRVH_HVB_V_B

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

HV battery cell max state of charge CRVH_HV_BATTERY_CELL_MAX_STATE_OF_CHARGEConfirmed

  • Request22 20 12
  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 208 to 223 of the reply, 16 bits. The value is signed.

0x0E36 = 3638 → (3638 ÷ 100) = 36.38 %

Formula
(val ÷ 100)
Range
-327.68 to 100 %
Unit
%

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2026.

HV battery current CRVH_HV_BATTERY_CURRENTConfirmed

  • Request22 20 10
  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 32 to 47 of the reply, 16 bits. The value is signed.

0x0091 = 145 → (145 ÷ 100) = 1.45 A

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2026.

HV battery fan 3 speed CRVH_HV_BATTERY_FAN_3_SPEED

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 288 to 295 of the reply, 8 bits.

Formula
(val × 100)
Range
0 to 25500 rpm
Unit
rpm

In testing for 2017 to 2022, 2024 to 2026. Supported for 2023, 2027.

HV battery max cell voltage CRVH_HV_BATTERY_MAX_CELL_VOLTAGE

  • Request22 22 22
  • Service 22DID 2222
  • ModuleDBEF
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2026. Not supported for 2023, 2027.

HV battery usable capacity CRVH_HV_BATTERY_USABLE_CAPACITYConfirmed

  • Request22 20 12
  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 32 to 39 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2026.

Normal charger input voltage CRVH_CHG_V_IN

  • Request22 20 21
  • Service 22DID 2021
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 500 V
Unit
V

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Normal charger output voltage CRVH_CHG_V_OUT

  • Request22 20 21
  • Service 22DID 2021
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 500 V
Unit
V

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

State of charge CRVH_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

State of charge CRVH_STATE_OF_CHARGEConfirmed

  • Request22 20 12
  • Service 22DID 2012
  • ModuleDBEF
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Example reply from a 2027 Honda CR-V Hybrid.

Bits 40 to 47 of the reply, 8 bits.

0x1D = 29 → 29 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2026.

Battery › Cells

Battery capacity, line B CRVH_HVB_CAP_B

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 Ah
Unit
Ah

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 1 CRVH_CEL_V_B1

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 2 CRVH_CEL_V_B2

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 3 CRVH_CEL_V_B3

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 4 CRVH_CEL_V_B4

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 5 CRVH_CEL_V_B5

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 6 CRVH_CEL_V_B6

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 7 CRVH_CEL_V_B7

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 8 CRVH_CEL_V_B8

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 328 to 343 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 9 CRVH_CEL_V_B9

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 344 to 359 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 10 CRVH_CEL_V_B10

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 11 CRVH_CEL_V_B11

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 12 CRVH_CEL_V_B12

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 13 CRVH_CEL_V_B13

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 14 CRVH_CEL_V_B14

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 15 CRVH_CEL_V_B15

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 16 CRVH_CEL_V_B16

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 456 to 471 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 17 CRVH_CEL_V_B17

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 472 to 487 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 18 CRVH_CEL_V_B18

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 19 CRVH_CEL_V_B19

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 504 to 519 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 20 CRVH_CEL_V_B20

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 520 to 535 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 21 CRVH_CEL_V_B21

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 536 to 551 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 22 CRVH_CEL_V_B22

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 552 to 567 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 23 CRVH_CEL_V_B23

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 568 to 583 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 24 CRVH_CEL_V_B24

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 25 CRVH_CEL_V_B25

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 26 CRVH_CEL_V_B26

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 616 to 631 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 27 CRVH_CEL_V_B27

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 632 to 647 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 28 CRVH_CEL_V_B28

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 648 to 663 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 29 CRVH_CEL_V_B29

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 664 to 679 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 30 CRVH_CEL_V_B30

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 680 to 695 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 31 CRVH_CEL_V_B31

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 696 to 711 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 32 CRVH_CEL_V_B32

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 712 to 727 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 33 CRVH_CEL_V_B33

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 728 to 743 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 34 CRVH_CEL_V_B34

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 744 to 759 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 35 CRVH_CEL_V_B35

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 760 to 775 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 36 CRVH_CEL_V_B36

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 776 to 791 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 37 CRVH_CEL_V_B37

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 792 to 807 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 38 CRVH_CEL_V_B38

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 808 to 823 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 39 CRVH_CEL_V_B39

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 824 to 839 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 40 CRVH_CEL_V_B40

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 840 to 855 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 41 CRVH_CEL_V_B41

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 856 to 871 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 42 CRVH_CEL_V_B42

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 872 to 887 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 43 CRVH_CEL_V_B43

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 888 to 903 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 44 CRVH_CEL_V_B44

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 904 to 919 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 45 CRVH_CEL_V_B45

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 920 to 935 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 46 CRVH_CEL_V_B46

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 936 to 951 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 47 CRVH_CEL_V_B47

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 952 to 967 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 48 CRVH_CEL_V_B48

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 968 to 983 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 49 CRVH_CEL_V_B49

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 984 to 999 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 50 CRVH_CEL_V_B50

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 51 CRVH_CEL_V_B51

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 52 CRVH_CEL_V_B52

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 53 CRVH_CEL_V_B53

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 54 CRVH_CEL_V_B54

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 55 CRVH_CEL_V_B55

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 56 CRVH_CEL_V_B56

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 57 CRVH_CEL_V_B57

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 58 CRVH_CEL_V_B58

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 59 CRVH_CEL_V_B59

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 60 CRVH_CEL_V_B60

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 61 CRVH_CEL_V_B61

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 62 CRVH_CEL_V_B62

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 63 CRVH_CEL_V_B63

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 64 CRVH_CEL_V_B64

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 65 CRVH_CEL_V_B65

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 66 CRVH_CEL_V_B66

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 67 CRVH_CEL_V_B67

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 68 CRVH_CEL_V_B68

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 69 CRVH_CEL_V_B69

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 70 CRVH_CEL_V_B70

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 71 CRVH_CEL_V_B71

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 72 CRVH_CEL_V_B72

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 73 CRVH_CEL_V_B73

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 74 CRVH_CEL_V_B74

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 75 CRVH_CEL_V_B75

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 76 CRVH_CEL_V_B76

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 77 CRVH_CEL_V_B77

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 78 CRVH_CEL_V_B78

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 79 CRVH_CEL_V_B79

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 80 CRVH_CEL_V_B80

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 81 CRVH_CEL_V_B81

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 82 CRVH_CEL_V_B82

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 83 CRVH_CEL_V_B83

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Cell voltage, 84 CRVH_CEL_V_B84

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Individual cell max SOC, line B CRVH_CEL_MAX_SOC_B

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Individual cell min SOC, line B CRVH_CEL_MIN_SOC_B

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA16 → 16
  • Every1 s
  • Testing

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2017 to 2022, 2024 to 2025. Not supported for 2023, 2026 to 2027.

Individual cell voltage A1 CRVH_CEL_V_A1Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 216 to 231 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A2 CRVH_CEL_V_A2Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 232 to 247 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A3 CRVH_CEL_V_A3Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 248 to 263 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A4 CRVH_CEL_V_A4Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 264 to 279 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A5 CRVH_CEL_V_A5Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 280 to 295 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A6 CRVH_CEL_V_A6Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 296 to 311 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A7 CRVH_CEL_V_A7Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 312 to 327 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A8 CRVH_CEL_V_A8Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 328 to 343 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A9 CRVH_CEL_V_A9Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 344 to 359 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A10 CRVH_CEL_V_A10Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 360 to 375 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A11 CRVH_CEL_V_A11Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 376 to 391 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A12 CRVH_CEL_V_A12Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A13 CRVH_CEL_V_A13Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 408 to 423 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A14 CRVH_CEL_V_A14Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 424 to 439 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A15 CRVH_CEL_V_A15Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 440 to 455 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A16 CRVH_CEL_V_A16Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 456 to 471 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A17 CRVH_CEL_V_A17Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 472 to 487 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A18 CRVH_CEL_V_A18Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A19 CRVH_CEL_V_A19Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 504 to 519 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A20 CRVH_CEL_V_A20Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 520 to 535 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A21 CRVH_CEL_V_A21Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 536 to 551 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A22 CRVH_CEL_V_A22Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 552 to 567 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A23 CRVH_CEL_V_A23Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 568 to 583 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A24 CRVH_CEL_V_A24Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A25 CRVH_CEL_V_A25Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A26 CRVH_CEL_V_A26Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 616 to 631 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A27 CRVH_CEL_V_A27Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 632 to 647 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A28 CRVH_CEL_V_A28Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 648 to 663 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A29 CRVH_CEL_V_A29Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 664 to 679 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A30 CRVH_CEL_V_A30Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 680 to 695 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A31 CRVH_CEL_V_A31Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 696 to 711 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A32 CRVH_CEL_V_A32Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 712 to 727 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A33 CRVH_CEL_V_A33Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 728 to 743 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A34 CRVH_CEL_V_A34Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 744 to 759 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A35 CRVH_CEL_V_A35Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 760 to 775 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A36 CRVH_CEL_V_A36Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 776 to 791 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A37 CRVH_CEL_V_A37Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 792 to 807 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A38 CRVH_CEL_V_A38Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 808 to 823 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A39 CRVH_CEL_V_A39Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 824 to 839 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A40 CRVH_CEL_V_A40Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 840 to 855 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A41 CRVH_CEL_V_A41Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 856 to 871 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A42 CRVH_CEL_V_A42Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 872 to 887 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A43 CRVH_CEL_V_A43Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 888 to 903 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A44 CRVH_CEL_V_A44Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 904 to 919 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A45 CRVH_CEL_V_A45Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 920 to 935 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A46 CRVH_CEL_V_A46Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 936 to 951 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A47 CRVH_CEL_V_A47Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 952 to 967 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A48 CRVH_CEL_V_A48Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 968 to 983 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A49 CRVH_CEL_V_A49Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 984 to 999 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A50 CRVH_CEL_V_A50Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,000 to 1,015 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A51 CRVH_CEL_V_A51Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,016 to 1,031 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A52 CRVH_CEL_V_A52Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,032 to 1,047 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A53 CRVH_CEL_V_A53Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,048 to 1,063 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A54 CRVH_CEL_V_A54Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,064 to 1,079 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A55 CRVH_CEL_V_A55Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,080 to 1,095 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A56 CRVH_CEL_V_A56Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,096 to 1,111 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A57 CRVH_CEL_V_A57Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,112 to 1,127 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A58 CRVH_CEL_V_A58Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,128 to 1,143 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A59 CRVH_CEL_V_A59Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,144 to 1,159 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A60 CRVH_CEL_V_A60Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,160 to 1,175 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A61 CRVH_CEL_V_A61Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,176 to 1,191 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A62 CRVH_CEL_V_A62Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,192 to 1,207 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A63 CRVH_CEL_V_A63Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,208 to 1,223 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A64 CRVH_CEL_V_A64Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,224 to 1,239 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A65 CRVH_CEL_V_A65Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,240 to 1,255 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A66 CRVH_CEL_V_A66Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,256 to 1,271 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A67 CRVH_CEL_V_A67Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,272 to 1,287 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A68 CRVH_CEL_V_A68Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,288 to 1,303 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A69 CRVH_CEL_V_A69Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,304 to 1,319 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A70 CRVH_CEL_V_A70Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,320 to 1,335 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A71 CRVH_CEL_V_A71Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,336 to 1,351 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A72 CRVH_CEL_V_A72Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,352 to 1,367 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A73 CRVH_CEL_V_A73Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,368 to 1,383 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A74 CRVH_CEL_V_A74Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,384 to 1,399 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A75 CRVH_CEL_V_A75Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,400 to 1,415 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A76 CRVH_CEL_V_A76Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,416 to 1,431 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A77 CRVH_CEL_V_A77Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,432 to 1,447 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A78 CRVH_CEL_V_A78Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,448 to 1,463 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A79 CRVH_CEL_V_A79Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,464 to 1,479 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A80 CRVH_CEL_V_A80Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,480 to 1,495 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A81 CRVH_CEL_V_A81Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,496 to 1,511 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A82 CRVH_CEL_V_A82Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,512 to 1,527 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A83 CRVH_CEL_V_A83Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,528 to 1,543 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Individual cell voltage A84 CRVH_CEL_V_A84Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2017 to 2022, 2024 to 2026

Bits 1,544 to 1,559 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2023, 2027. In testing for 2017 to 2022, 2024 to 2025. Not supported for 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.