Honda e

Fuel parameters

The Honda e has 5 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air-fuel mixture heater HONDA_AIR_FUEL_MIXTURE

  • Request22 26 6D
  • Service 22DID 266D
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2020 to 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air-fuel mixture heater HONDA_AIR_FUEL_MIXTURE

  • Request22 26 6D
  • Service 22DID 266D
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2020 to 2024.

Fuel level HONDA_FLV

Pelican can show this parameter as the fuel tank level.

  • Request22 70 29
  • Service 22DID 7029
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 L
Unit
L

In testing for 2020 to 2024.

Fuel pressure sensor A, raw count HONDA_SENS_FUEL_P_RAW_CNT

  • Request22 26 15
  • Service 22DID 2615
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2024.

Fuel/air commanded equivalence ratio HONDA_FUEL_AIR_RAT_PCM

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024.

Fuel/air commanded equivalence ratio HONDA_FUEL_AIR_RATIO

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?