Battery parameters
The Honda Element has 2 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2007. Supported for 2008 to 2009.
Distance traveled since last charge ELEMENT_BAT_DISTConfirmed
- Request
22 22 40 - Service 22
DID 2240 - Module
DA0E → 0E - Every
30 s - Testing for 2010 to 2011
Bits 80 to 111 of the reply, 32 bits.
- Formula
val- Range
- 0 to 250000 km
- Unit
- km
Confirmed for 2008 to 2009. In testing for 2010 to 2011.