Honda HR-V

Electrical parameters

The Honda HR-V has 6 electrical parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Brake fluid pressure HRV_BRK_FLD_P

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 5
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Brake fluid pressure HRV_BRK_FLD_P

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 5
Unit
Raw value

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Brake pedal stroke HRV_BRK_PED_STK

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 50 mm
Unit
mm

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Brake pressure HRV_BRK_PConfirmed

  • Request22 40 05
  • Service 22DID 4005
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2022, 2024 to 2026

Bits 56 to 71 of the reply, 16 bits.

Formula
(val − 25)
Range
0 to 120 bar
Unit
bar

Confirmed for 2023. In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026. Not supported for 2022.

Brake switch HRV_BRK_SWConfirmed

  • Request22 40 04
  • Service 22DID 4004
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 1998 to 2006, 2013 to 2022, 2024 to 2026

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026. Not supported for 2022.

Master cylinder stroke HRV_MSTR_CYL_STK

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 mm
Unit
mm

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Slave cylinder stroke HRV_SLV_CYL_STK

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 mm
Unit
mm

In testing for 1998 to 2006, 2013 to 2021, 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.