Honda Pilot

Clock parameters

The Honda Pilot has 3 clock parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Time since engine start PILOT_RUNTMConfirmed

How long it's been since the engine started.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2003 to 2016, 2018 to 2023, 2026

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2017, 2024 to 2025. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Time since engine start PILOT_RUNTMConfirmed

How long it's been since the engine started.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA10 → 10
  • Every5 s
  • Testing for 2003 to 2016, 2018 to 2023, 2026

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2017, 2024 to 2025. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2019.

Time since engine start PILOT_RUNTM_PCMConfirmed

How long it's been since the engine started.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA0E → 0E
  • Every5 s
  • Testing for 2003 to 2018, 2020 to 2026

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2019. In testing for 2003 to 2016, 2018, 2020 to 2023, 2026. Not supported for 2017, 2024 to 2025.

Time since engine start PILOT_RUNTM_V2Confirmed

How long it's been since the engine started.

  • Request22 26 60
  • Service 22DID 2660
  • ModuleDA11 → 11
  • Every5 s
  • Testing for 2003 to 2012, 2014 to 2026

Bits 368 to 383 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2013. In testing for 2003 to 2006, 2008 to 2012, 2014 to 2016, 2018, 2021 to 2022, 2026. Not supported for 2007, 2017, 2019 to 2020, 2023 to 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.