Engine parameters
The Hyundai Ioniq Electric has 279 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
4WD calculated clutch power IONIQEV_AWD_CALC_CLU_POWER
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 39.062 ÷ 10000)- Range
- 0 to 255 kWh
- Unit
- kWh
In testing for 2016 to 2022.
4WD calculated engine power IONIQEV_AWD_CALC_ENG_POWER
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val × 9.766 ÷ 10000)- Range
- 0 to 64 kWh
- Unit
- kWh
In testing for 2016 to 2022.
4WD calculated, commanded torque IONIQEV_AWD_CALC_CMD_TQ
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 8)- Range
- -4096 to 4095.875 N·m
- Unit
- N·m
In testing for 2016 to 2022.
4WD clutch, actual pressure IONIQEV_AWD_CLU_ACT_P
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 144 to 159 of the reply, 16 bits. The value is signed.
- Formula
(val × 19.53 ÷ 10000)- Range
- -63.99 to 63.99 bar
- Unit
- bar
In testing for 2016 to 2022.
4WD clutch, actual torque IONIQEV_AWD_CLU_ACT_TQ
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 8)- Range
- -4096 to 4095.875 N·m
- Unit
- N·m
In testing for 2016 to 2022.
4WD max clutch stress IONIQEV_AWD_MAX_CLU_STRESS
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val × 19.531 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
4WD pump current IONIQEV_AWD_PMP_CURRENT
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
(val × 78.125 ÷ 10000)- Range
- -256 to 255 A
- Unit
- A
In testing for 2016 to 2022.
4WD pump PWM duty IONIQEV_AWD_PMP_PWM_DUTY
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2017 to 2018.
Adaptation value for lower stop of wastegate actuator IONIQEV_ADPT_LO_STOP
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- -5.01 to 5.01 V
- Unit
- V
In testing for 2016 to 2022.
Air conditioning pressure IONIQEV_AC_P
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 13.79)- Range
- 0 to 3516.45 kPa
- Unit
- kPa
In testing for 2016 to 2022.
Air conditioning relay IONIQEV_AC_RELAY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 101 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2017 to 2018.
Automatic transmission fluid temperature IONIQEV_ATF_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2022.
AUX amps LDC IONIQEV_AUX_AMPS_LDC
- Request
21 02 - Service 21
PID 02 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2016 to 2022.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017.
Barometric pressure IONIQEV_BAROMETRIC_PRESSURE
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 319 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 kPa
- Unit
- kPa
In testing for 2016 to 2022.
Battery management ignition IONIQEV_BAT_MANAGEMENT_IGN
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 405 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Battery management main relay IONIQEV_BAT_MANAGEMENT_MAIN
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 79 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Boost pressure IONIQEV_BOOST_P
- Request
22 E0 F2 - Service 22
DID E0F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2016 to 2022.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017.
Calculated oil temperature IONIQEV_CALC_OIL_T
- Request
22 E0 11 - Service 22
DID E011 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2022.
Catalyst damaging misfires total all cylinders IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total all cylinders IONIQEV_CATDMG_MIS_TOT_ALL
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 1 IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 1 IONIQEV_CATDMG_MIS_TOT_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 2 IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 2 IONIQEV_CATDMG_MIS_TOT_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 3 IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 3 IONIQEV_CATDMG_MIS_TOT_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 4 IONIQEV_CATALYST_DAMAGING_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 4 IONIQEV_CATDMG_MIS_TOT_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 5 IONIQEV_CATDMG_MIS_TOT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst damaging misfires total, cylinder 6 IONIQEV_CATDMG_MIS_TOT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2017 to 2018.
Catalyst temperature bank 1, sensor 2 CATEMP12SAE J1979Confirmed
- Request
01 3E - Service 01
PID 3E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2017 to 2018.
Clutch solenoid duty IONIQEV_CLUTCH_SOLENOID_DUTY
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2022.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Request
01 2C - Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2017.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017.
Commanded evaporative purge IONIQEV_COMMANDED_EVAPORATIVE_PURGE
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2016 to 2022.
Commanded throttle actuator IONIQEV_COMMANDED_THROTTLE_ACTUATOR
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2016 to 2022.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017.
Commanded torque IONIQEV_COMMANDED_TORQUE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 N·m
- Unit
- N·m
In testing for 2016 to 2022.
Coolant IONIQEV_COOLANT_FAN
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Coolant fan PWM IONIQEV_CLT_FAN_PWM
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val × 15.21 ÷ 10000)- Range
- 0 to 99.67 %
- Unit
- %
In testing for 2016 to 2022.
Coolant temperature IONIQEV_HVAC_COOLANT_T
- Request
22 01 02 - Service 22
DID 0102 - Module
7B3 → 7BB - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2016 to 2022.
Crankshaft torque IONIQEV_CRANK_TQ
- Request
22 ED 05 - Service 22
DID ED05 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 600 ÷ 255)- Range
- 0 to 600 N·m
- Unit
- N·m
In testing for 2016 to 2022.
Cylinder 1 injection time, 1st pulse IONIQEV_CYL_1_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Cylinder 1 injection time, 2nd pulse IONIQEV_CYL_1_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Cylinder 2 injection time, 1st pulse IONIQEV_CYL_2_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Cylinder 2 injection time, 2nd pulse IONIQEV_CYL_2_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Cylinder 3 injection time, 1st pulse IONIQEV_CYL_3_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Cylinder 3 injection time, 2nd pulse IONIQEV_CYL_3_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Cylinder 4 injection time, 1st pulse IONIQEV_CYL_4_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Cylinder 4 injection time, 2nd pulse IONIQEV_CYL_4_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Diesel particulate filter differential pressure IONIQEV_DPF_DIFF_P
- Request
22 E0 F1 - Service 22
DID E0F1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val × 4.3137 − 100)- Range
- -100 to 999.9935
- Unit
- Raw value
In testing for 2016 to 2022.
Diesel particulate filter differential pressure IONIQEV_DPF_DIFF_P_7E0
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
(val × 431.373 ÷ 100)- Range
- 0 to 1100
- Unit
- Raw value
In testing for 2016 to 2022.
Diesel particulate filter differential pressure IONIQEV_DPF_DIFFERENTIAL_PRESSURE
- Request
21 1B - Service 21
PID 1B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5
- Unit
- Raw value
In testing for 2016 to 2022.
Diesel particulate filter regeneration count IONIQEV_DPF_REGEN_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 440 to 447 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Diesel particulate filter regeneration state IONIQEV_DPF_REGENERATION_STATE
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 207 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Diesel particulate filter soot mass IONIQEV_DPF_SOOT_MASS
- Request
22 ED 94 - Service 22
DID ED94 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 99 ÷ 255)- Range
- 0 to 99 g
- Unit
- g
In testing for 2016 to 2022.
Diesel particulate filter successful regeneration count IONIQEV_DPF_SUCCESSFUL_REGEN
- Request
22 E0 F2 - Service 22
DID E0F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Diesel particulate filter total sulfur mass IONIQEV_DPF_TOT_SULFUR_MASS
- Request
22 ED 29 - Service 22
DID ED29 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.15259)- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2016 to 2022.
Direct injection time 1 IONIQEV_DI_TIME_1
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2022.
Direct injection time 2 IONIQEV_DI_TIME_2
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2022.
Direct injection time 3 IONIQEV_DI_TIME_3
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2022.
Direct injection time 4 IONIQEV_DI_TIME_4
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2022.
Direct injection time 5 IONIQEV_DI_TIME_5
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2022.
Direct injection time 6 IONIQEV_DI_TIME_6
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2022.
Disconnector actuator motor current IONIQEV_DISCONNECTOR_ACTUATOR_MOTOR_CURRENT
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits. The value is signed.
- Formula
(val × 2)- Range
- -256 to 254 A
- Unit
- A
In testing for 2016 to 2022.
Disconnector disengage last time IONIQEV_DISCONNECTOR_DISENGAGE_LAST_TIME
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 ms
- Unit
- ms
In testing for 2016 to 2022.
Disconnector end point IONIQEV_DISCONNECTOR_END_POINT
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 mm
- Unit
- mm
In testing for 2016 to 2022.
Disconnector inverter PWM duty IONIQEV_DISCONNECTOR_INVERTER_PWM_DUTY
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 78.125 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Disconnector meet point IONIQEV_DISCONNECTOR_MEET_POINT
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 mm
- Unit
- mm
In testing for 2016 to 2022.
Disconnector stroke position IONIQEV_DISCONNECTOR_STROKE_POSITION
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 mm
- Unit
- mm
In testing for 2016 to 2022.
Disconnector zero count offset IONIQEV_DISCONNECTOR_ZERO_COUNT_OFFSET
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 2016 to 2022.
Drive motor speed IONIQEV_RPM
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Dual-clutch transmission clutch 1, pressure sensor A IONIQEV_DUAL_CLU_TRANS_CLU_1_P
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2016 to 2022.
Dual-clutch transmission clutch 2, pressure sensor B IONIQEV_DUAL_CLU_TRANS_CLU_2_P_B
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2016 to 2022.
Dual-clutch transmission fluid temperature 1 IONIQEV_DUAL_CLU_ATF_T_1
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2022.
Dual-clutch transmission fluid temperature 2 IONIQEV_DUAL_CLU_ATF_T_2
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2022.
Dual-clutch transmission line pressure, sensor C IONIQEV_DUAL_CLU_TRANS_LINE_P_C
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2016 to 2022.
EGR error EGR_ERRSAE J1979Confirmed
- Request
01 2D - Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2017.
Emission relevant misfires total all cylinders IONIQEV_EMIS_MIS_TOT_ALL
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total all cylinders IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 1 IONIQEV_EMIS_MIS_TOT_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 1 IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 2 IONIQEV_EMIS_MIS_TOT_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 2 IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 3 IONIQEV_EMIS_MIS_TOT_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 3 IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 4 IONIQEV_EMIS_MIS_TOT_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 4 IONIQEV_EMISSION_RELEVANT_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 5 IONIQEV_EMIS_MIS_TOT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission relevant misfires total, cylinder 6 IONIQEV_EMIS_MIS_TOT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017 to 2018.
Engine oil temperature IONIQEV_EOT
- Request
22 ED 02 - Service 22
DID ED02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val − 4)- Range
- -4 to 215 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Engine oil temperature IONIQEV_EOT_7E0Confirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 272 to 279 of the reply, 8 bits.
0xA1 = 161 → (161 × 3 ÷ 4 − 48) = 72.75 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Engine oil temperature IONIQEV_EOT_7E0_7E0
- Request
22 ED 07 - Service 22
DID ED07 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 0.7843 − 50)- Range
- -50 to 149.9965 °C
- Unit
- °C
In testing for 2016 to 2022.
Engine RPM IONIQEV_RPM_7E5
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2016 to 2022.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2017 to 2018.
Engine run time, total IONIQEV_ENG_RUN_TIME_TOT
- Request
21 0E - Service 21
PID 0E - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 6)- Range
- 0 to 393209.9999 min
- Unit
- min
In testing for 2016 to 2022.
Engine, actual torque IONIQEV_ENG_ACT_TQ
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 23529 ÷ 10000)- Range
- 0 to 599.9895 N·m
- Unit
- N·m
In testing for 2016 to 2022.
Exhaust camshaft position IONIQEV_EXH_CAM_POS
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2016 to 2022.
Exhaust gas temperature IONIQEV_EXHAUST_GAS_T
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 368 to 375 of the reply, 8 bits.
- Formula
(val × 4.709803922 + 99)- Range
- 99 to 1300 °C
- Unit
- °C
In testing for 2016 to 2022.
Exhaust temperature 1, upstream of oxidation catalyst IONIQEV_EXH_T_1_UP_OXICAT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 296 to 303 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2016 to 2022.
Exhaust temperature 2, upstream of DPF IONIQEV_EXH_T_2_UP_DPF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2016 to 2022.
Front left tire temperature IONIQEV_FL_TT
Pelican can show this parameter as the front left tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2022.
Front right tire temperature IONIQEV_FR_TT
Pelican can show this parameter as the front right tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2022.
Fuel rail pressure (absolute) FRP_ABSSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 59 - Service 01
PID 59 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2017 to 2018.
Gasoline direct injection time bank a, 1 IONIQEV_GDI_IT_A1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2022.
Gasoline direct injection time bank a, 2 IONIQEV_GDI_IT_A2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2022.
Gasoline direct injection time bank a, 3 IONIQEV_GDI_IT_A3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2022.
Gasoline direct injection time bank a, 4 IONIQEV_GDI_IT_A4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2022.
Gasoline direct injection time bank b, 1 IONIQEV_GDI_IT_B1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2022.
Gasoline direct injection time bank b, 2 IONIQEV_GDI_IT_B2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2022.
Gasoline direct injection time bank b, 3 IONIQEV_GDI_IT_B3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2022.
Gasoline direct injection time bank b, 4 IONIQEV_GDI_IT_B4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2022.
Heat IONIQEV_HEAT
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2016 to 2022.
Heat sink temperature IONIQEV_HEAT_SINK_T
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2016 to 2022.
Hv_charging IONIQEV_HV_CHG
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 72 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Idle control mode IONIQEV_IDLE_CONTROL_MODE
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Ignition retard due to knock control 1 IONIQEV_IGN_RETARD_KNOCK_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Ignition retard due to knock control 2 IONIQEV_IGN_RETARD_KNOCK_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Ignition retard due to knock control 3 IONIQEV_IGN_RETARD_KNOCK_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Ignition retard due to knock control 4 IONIQEV_IGN_RETARD_KNOCK_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Ignition voltage IONIQEV_IGN_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10 ÷ 10000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2022.
Injection duration cylinder 1 IONIQEV_INJ_DUR_1Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0001 = 1 → (1 ÷ 1220.7) = 0.000819 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Injection duration cylinder 2 IONIQEV_INJ_DUR_2Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0001 = 1 → (1 ÷ 1220.7) = 0.000819 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Injection duration cylinder 3 IONIQEV_INJ_DUR_3Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0001 = 1 → (1 ÷ 1220.7) = 0.000819 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Injection duration cylinder 4 IONIQEV_INJ_DUR_4Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0001 = 1 → (1 ÷ 1220.7) = 0.000819 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Injection impulse 1, cylinder 1 IONIQEV_INJ_IMPULSE_1_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 1, cylinder 2 IONIQEV_INJ_IMPULSE_1_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 1, cylinder 3 IONIQEV_INJ_IMPULSE_1_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 1, cylinder 4 IONIQEV_INJ_IMPULSE_1_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 2, cylinder 1 IONIQEV_INJ_IMPULSE_2_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 2, cylinder 2 IONIQEV_INJ_IMPULSE_2_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 2, cylinder 3 IONIQEV_INJ_IMPULSE_2_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 2, cylinder 4 IONIQEV_INJ_IMPULSE_2_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 3, cylinder 1 IONIQEV_INJ_IMPULSE_3_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 3, cylinder 2 IONIQEV_INJ_IMPULSE_3_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 3, cylinder 3 IONIQEV_INJ_IMPULSE_3_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
In testing for 2016 to 2022.
Injection impulse 3, cylinder 4 IONIQEV_INJ_IMPULSE_3_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
In testing for 2016 to 2022.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017 to 2018.
Intake air temperature IONIQEV_EITConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 264 to 271 of the reply, 8 bits.
0x70 = 112 → (112 × 3 ÷ 4 − 48) = 36 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Intake camshaft position IONIQEV_INT_CAM_POS
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2016 to 2022.
Intake camshaft position actual IONIQEV_INTAKE_CAMSHAFT_POSITION_ACTUAL
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2016 to 2022.
Intake camshaft position commanded IONIQEV_INTAKE_CAMSHAFT_POSITION_COMMANDED
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2016 to 2022.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2017.
Inverter temperature IONIQEV_HVAC_INVERTER_T
- Request
22 01 02 - Service 22
DID 0102 - Module
7B3 → 7BB - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2016 to 2022.
Inverter temperature IONIQEV_INVERTER_T
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2016 to 2022.
Isolation resistance IONIQEV_ISOLATION_RES
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kΩ
- Unit
- kΩ
In testing for 2016 to 2022.
Knock detected IONIQEV_KNOCK_DETECTED
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Knock learn, cylinder 1 IONIQEV_KNOCK_LEARN_1
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2016, 2019 to 2022
Bits 160 to 167 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.
Knock learn, cylinder 2 IONIQEV_KNOCK_LEARN_2
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2016, 2019 to 2022
Bits 168 to 175 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.
Knock learn, cylinder 3 IONIQEV_KNOCK_LEARN_3
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2016, 2019 to 2022
Bits 176 to 183 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.
Knock learn, cylinder 4 IONIQEV_KNOCK_LEARN_4
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2016, 2019 to 2022
Bits 184 to 191 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.
Knock retard cylinder #1 IONIQEV_KNOCK_RETARD_CYLINDER_1
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder #2 IONIQEV_KNOCK_RETARD_CYLINDER_2
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder #3 IONIQEV_KNOCK_RETARD_CYLINDER_3
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder #4 IONIQEV_KNOCK_RETARD_CYLINDER_4
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 1 IONIQEV_KNOCK_RETARD_CYL_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 1, alternate IONIQEV_KNOCK_RETARD_1_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 1, alternate IONIQEV_KNOCK_RETARD_CYL_1_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 2 IONIQEV_KNOCK_RETARD_CYL_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 2, alternate IONIQEV_KNOCK_RETARD_2_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 2, alternate IONIQEV_KNOCK_RETARD_CYL_2_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 3 IONIQEV_KNOCK_RETARD_CYL_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 3, alternate IONIQEV_KNOCK_RETARD_3_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 3, alternate IONIQEV_KNOCK_RETARD_CYL_3_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 4 IONIQEV_KNOCK_RETARD_CYL_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 4, alternate IONIQEV_KNOCK_RETARD_4_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard cylinder 4, alternate IONIQEV_KNOCK_RETARD_CYL_4_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2022.
Knock retard, cylinder 1 IONIQEV_KNOCK_RETARD_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 96 to 103 of the reply, 8 bits. The value is signed.
0x71 = 113 → (113 ÷ 5) = 22.6 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Knock retard, cylinder 2 IONIQEV_KNOCK_RETARD_2Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 104 to 111 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Knock retard, cylinder 3 IONIQEV_KNOCK_RETARD_3Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 112 to 119 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Knock retard, cylinder 4 IONIQEV_KNOCK_RETARD_4Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 120 to 127 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Lock switch IONIQEV_LOCK_SWITCH
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bit 151 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017 to 2018.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Request
01 56 - Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2017 to 2018.
Main injection volume IONIQEV_MAIN_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.392156863)- Range
- 0 to 100 L
- Unit
- L
In testing for 2016 to 2022.
Malfunction indicator IONIQEV_MALFUNCTION_INDICATOR
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Mass air flow rate IONIQEV_MAF_RATE
- Request
22 E0 10 - Service 22
DID E010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.
- Formula
(val × 0.04239)- Range
- 0 to 10.8
- Unit
- Raw value
In testing for 2016 to 2022.
Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running IONIQEV_MAX_ADPT_LO_MECH_STOP_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2016 to 2022.
Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop IONIQEV_MAX_ADPT_LO_MECH_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2016 to 2022.
Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running IONIQEV_MIN_ADPT_LO_MECH_STOP_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2016 to 2022.
Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop IONIQEV_MIN_ADPT_LO_MECH_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2016 to 2022.
Misfire count #1 IONIQEV_MIS_1
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7D8 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Misfire count #2 IONIQEV_MIS_2
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7D8 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Misfire count #3 IONIQEV_MIS_3
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7D8 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Misfire count #4 IONIQEV_MIS_4
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7D8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Misfires current total IONIQEV_MIS_CURRENT_TOT
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 584 to 591 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Misfires current, cylinder 1 IONIQEV_MIS_CURRENT_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 536 to 543 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Misfires current, cylinder 2 IONIQEV_MIS_CURRENT_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 544 to 551 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Misfires current, cylinder 3 IONIQEV_MIS_CURRENT_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 552 to 559 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Misfires current, cylinder 4 IONIQEV_MIS_CURRENT_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 560 to 567 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Misfires current, cylinder 5 IONIQEV_MIS_CURRENT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 568 to 575 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Misfires current, cylinder 6 IONIQEV_MIS_CURRENT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 576 to 583 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Misfires harmful for catalyst, cylinder 1 IONIQEV_MIS_HARMFUL_CAT_1
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires harmful for catalyst, cylinder 2 IONIQEV_MIS_HARMFUL_CAT_2
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires harmful for catalyst, cylinder 3 IONIQEV_MIS_HARMFUL_CAT_3
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires harmful for catalyst, cylinder 4 IONIQEV_MIS_HARMFUL_CAT_4
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, current, cylinder 1 IONIQEV_MISFIRES_C1_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, current, cylinder 2 IONIQEV_MISFIRES_C2_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, current, cylinder 3 IONIQEV_MISFIRES_C3_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, current, cylinder 4 IONIQEV_MISFIRES_C4_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, cylinder 1 IONIQEV_MIS_1_7E0_7E0
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, cylinder 2 IONIQEV_MIS_2_7E0_7E0
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, cylinder 3 IONIQEV_MIS_3_7E0_7E0
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, cylinder 4 IONIQEV_MIS_4_7E0_7E0
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Motor actual torque IONIQEV_MOTOR_ACTUAL_TORQUE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2016 to 2022.
Motor phase current IONIQEV_MOTOR_PHASE_CURRENT_RMS
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016 to 2022.
Motor RPM IONIQEV_MOTOR_RPM
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2016 to 2022.
Motor temperature IONIQEV_MOTOR_T
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2016 to 2022.
Motor-driven power steering current IONIQEV_MDPS_MOTOR_CURRENTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
250 ms - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 88 to 95 of the reply, 8 bits. The value is signed.
0x00 = 0 → 0 A
- Formula
val- Range
- -128 to 127 A
- Unit
- A
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Nominal torque value IONIQEV_NOMINAL_TORQUE_VALUE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2016 to 2022.
Operating time IONIQEV_OP_TIME
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 368 to 399 of the reply, 32 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 1193046
- Unit
- Raw value
In testing for 2016 to 2022.
Overheat protection, active IONIQEV_OVERHEAT_PROTECTION
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 132 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Oxygen sensor 1 bank 1 IONIQEV_OXYGEN_SENSOR_11
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2016 to 2022.
Oxygen sensor 2 bank 1 IONIQEV_OXYGEN_SENSOR_21
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2016 to 2022.
Pilot injection volume IONIQEV_PILOT_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2016 to 2022.
Post injection volume IONIQEV_POST_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2016 to 2022.
Pressure sensor IONIQEV_PRESSURE_SENSOR
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 bar
- Unit
- bar
In testing for 2016 to 2022.
Rail pressure control valve IONIQEV_RAIL_P_CTRL_VLV
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 55 of the reply.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 0.3921
- Unit
- Off or on
In testing for 2016 to 2022.
Rear left tire temperature IONIQEV_RL_TT
Pelican can show this parameter as the rear left tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2022.
Rear right tire temperature IONIQEV_RR_TT
Pelican can show this parameter as the rear right tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2022.
Regeneration demand counter by soot load IONIQEV_REGEN_DEMAND_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 320 to 327 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Requested torque IONIQEV_REQUESTED_TORQUE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.001526)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Requested torque limitation from traction control IONIQEV_REQ_TQ_LIM_TRACTION
- Request
22 ED 06 - Service 22
DID ED06 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017 to 2018.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Request
01 55 - Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2017 to 2018.
Successful regeneration state IONIQEV_SUCCESSFUL_REGEN_ST
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 424 to 431 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2022.
Throttle position #1 IONIQEV_THROTTLE_POSITION__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2016 to 2022.
Throttle position #2 IONIQEV_THROTTLE_POSITION__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2016 to 2022.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2017.
Timing advance #1 IONIQEV_TIMING_ADVANCE_1
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2016 to 2022.
Timing advance #2 IONIQEV_TIMING_ADVANCE_2
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2016 to 2022.
Timing advance #3 IONIQEV_TIMING_ADVANCE_3
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2016 to 2022.
Timing advance #4 IONIQEV_TIMING_ADVANCE_4
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2016 to 2022.
Torque converter slip IONIQEV_TORQUE_CONVERTER_SLIP_7E1
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2016 to 2022.
Torque converter slip IONIQEV_TQ_CONV_SLIP
- Request
21 A0 - Service 21
PID A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2016 to 2022.
Transmission fluid temperature IONIQEV_ATF_T_7E0
- Request
21 A0 - Service 21
PID A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2022.
Turbo boost pressure IONIQEV_TB_PRES
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 0.008291)- Range
- 0 to 543 kPa
- Unit
- kPa
In testing for 2016 to 2022.
Turbo boost pressure IONIQEV_TURBO_BOOST_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 829.1 ÷ 10000)- Range
- 0 to 5433
- Unit
- Raw value
In testing for 2016 to 2022.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2017 to 2018.
Variable valve timing temperature IONIQEV_CVVT_T
Continuously variable valve timing temperature.
- Request
21 18 - Service 21
PID 18 - Module
7E0 → 7D8 - Every
250 ms - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val − 48)- Range
- -48 to 207 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Waste gate duty IONIQEV_WG_DUTY
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val × 0.00305176)- Range
- 0 to 199 %
- Unit
- %
In testing for 2016 to 2022.
Waste gate position IONIQEV_WG_POS
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399 %
- Unit
- %
In testing for 2016 to 2022.
Waste gate set point IONIQEV_WG_SP
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399 %
- Unit
- %
In testing for 2016 to 2022.
Waste gate voltage IONIQEV_WG_V
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 0.000152588)- Range
- 0 to 9.99 V
- Unit
- V
In testing for 2016 to 2022.
Wastegate control PWM, wastegate actuator IONIQEV_WASTEGATE_CTRL_PWM
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 32767)- Range
- -100 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Wastegate position target, wastegate actuator IONIQEV_WASTEGATE_POS_TGT
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 200 ÷ 32767)- Range
- -200 to 200 %
- Unit
- %
In testing for 2016 to 2022.
Wastegate position, wastegate actuator IONIQEV_WASTEGATE_POS
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 200 ÷ 32767)- Range
- -200 to 200 %
- Unit
- %
In testing for 2016 to 2022.
Engine › Misfires
Emission-relevant misfires, cylinder #1 IONIQEV_MIS_CNT_EMIS_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission-relevant misfires, cylinder #2 IONIQEV_MIS_CNT_EMIS_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission-relevant misfires, cylinder #3 IONIQEV_MIS_CNT_EMIS_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Emission-relevant misfires, cylinder #4 IONIQEV_MIS_CNT_EMIS_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires harmful for catalyst cylinder 1 IONIQEV_MIS_CAT_1
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires harmful for catalyst cylinder 2 IONIQEV_MIS_CAT_2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires harmful for catalyst cylinder 3 IONIQEV_MIS_CAT_3
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires harmful for catalyst cylinder 4 IONIQEV_MIS_CAT_4
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires total counter, all cylinders IONIQEV_MIS_CNT_ALL
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires total counter, cylinder #1 IONIQEV_MIS_CNT_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires total counter, cylinder #2 IONIQEV_MIS_CNT_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires total counter, cylinder #3 IONIQEV_MIS_CNT_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires total counter, cylinder #4 IONIQEV_MIS_CNT_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, cylinder 1 IONIQEV_MIS_1_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, cylinder 2 IONIQEV_MIS_2_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, cylinder 3 IONIQEV_MIS_3_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Misfires, cylinder 4 IONIQEV_MIS_4_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2022.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.