Battery parameters
The Hyundai Venue has 13 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12v battery charge VENUE_VPWR_V3
- Request
22 E0 04 - Service 22
DID E004 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.
Aux battery state of charge VENUE_AUX_SOCConfirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 320 to 327 of the reply, 8 bits.
0x00 = 0 → 0 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Aux battery state of health VENUE_AUX_SOHConfirmed
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 328 to 335 of the reply, 8 bits.
0x00 = 0 → 0 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Control module voltage VENUE_CONTROL_MODULE_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2019 to 2024, 2026. Not supported for 2025.
Control module voltage after ignition VENUE_CONTROL_MODULE_VOLTAGE_AFTER_IGNITION
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2019 to 2024, 2026. Not supported for 2025.
Coolant temperature sensor voltage VENUE_COOLANT_T_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319 V
- Unit
- V
In testing for 2019 to 2024, 2026. Not supported for 2025.
IAT sensor voltage VENUE_IAT_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319 V
- Unit
- V
In testing for 2019 to 2024, 2026. Not supported for 2025.
Manifold absolute pressure sensor voltage VENUE_MAP_SENSOR_VOLTAGE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319 V
- Unit
- V
In testing for 2019 to 2024, 2026. Not supported for 2025.
Relative accelerator pedal position voltage VENUE_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 V
- Unit
- V
In testing for 2019 to 2026.
Supply voltage VENUE_SUPPLY_VOLTAGE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2019 to 2026.
System voltage VENUE_SYSTEM_VOLTAGE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2019 to 2026.
Throttle position sensor voltage #1 VENUE_THROTTLE_POSITION_SENSOR_VOLTAGE__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2019 to 2026.
Throttle position sensor voltage #2 VENUE_THROTTLE_POSITION_SENSOR_VOLTAGE__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2019 to 2026.