INFINITI QX70

Battery parameters

The INFINITI QX70 has 513 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery current INFINITI_12V_CURR

  • Request22 11 83
  • Service 22DID 1183
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 256)
Range
-128 to 128 A
Unit
A

In testing for 2003 to 2017.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery current INFINITI_12V_CURR

  • Request22 11 83
  • Service 22DID 1183
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 256)
Range
-128 to 128 A
Unit
A

In testing for 2003 to 2017.

12V battery voltage INFINITI_VPWR

Pelican can show this parameter as the starter battery voltage.

  • Request22 11 03
  • Service 22DID 1103
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 12.5)
Range
0 to 30 V
Unit
V

In testing for 2003 to 2017.

Absolute time since first ignition INFINITI_ABS_TIME_SINCE_FIRST

  • Request22 92 61
  • Service 22DID 9261
  • ModuleDADB → DAF1DB
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2003 to 2017.

Accelerator pedal position sensor 1, volts INFINITI_ACCEL_PEDAL_POS_SENS_1

  • Request22 12 0D
  • Service 22DID 120D
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Accelerator pedal position sensor 2, volts INFINITI_ACCEL_PEDAL_POS_SENS_2

  • Request22 12 0E
  • Service 22DID 120E
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

ALTERNATOR set point VOLTAGE INFINITI_ALTERNATOR_SETPOINT_V

  • Request21 69
  • Service 21PID 69
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310 V
Unit
V

In testing for 2003 to 2017.

Bus bar 1 flag INFINITI_BUSBAR_NO_1

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 1 voltage INFINITI_BUSBAR_V_NO_1

  • Request22 92 21
  • Service 22DID 9221
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.000976563)
Range
-32 to 31.99 V
Unit
V

In testing for 2003 to 2017.

Bus bar 2 flag INFINITI_BUSBAR_NO_2

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 2 voltage INFINITI_BUSBAR_V_NO_2

  • Request22 92 22
  • Service 22DID 9222
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.000976563)
Range
-32 to 31.99 V
Unit
V

In testing for 2003 to 2017.

Bus bar 3 flag INFINITI_BUSBAR_NO_3

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 3 voltage INFINITI_BUSBAR_V_NO_3

  • Request22 92 23
  • Service 22DID 9223
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.000976563)
Range
-32 to 31.99 V
Unit
V

In testing for 2003 to 2017.

Bus bar 4 flag INFINITI_BUSBAR_NO_4

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 4 voltage INFINITI_BUSBAR_V_NO_4

  • Request22 92 24
  • Service 22DID 9224
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.000976563)
Range
-32 to 31.99 V
Unit
V

In testing for 2003 to 2017.

Bus bar 5 flag INFINITI_BUSBAR_NO_5

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 5 voltage INFINITI_BUSBAR_V_NO_5

  • Request22 92 25
  • Service 22DID 9225
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.000976563)
Range
-32 to 31.99 V
Unit
V

In testing for 2003 to 2017.

Bus bar 6 flag INFINITI_BUSBAR_NO_6

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 6 voltage INFINITI_BUSBAR_V_NO_6

  • Request22 92 26
  • Service 22DID 9226
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.000976563)
Range
-32 to 31.99 V
Unit
V

In testing for 2003 to 2017.

Bus bar 7 flag INFINITI_BUSBAR_NO_7

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 7 voltage INFINITI_BUSBAR_V_NO_7

  • Request22 92 27
  • Service 22DID 9227
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.000976563)
Range
-32 to 31.99 V
Unit
V

In testing for 2003 to 2017.

Bus bar 8 flag INFINITI_BUSBAR_NO_8

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 8 voltage INFINITI_BUSBAR_V_NO_8

  • Request22 92 28
  • Service 22DID 9228
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.000976563)
Range
-32 to 31.99 V
Unit
V

In testing for 2003 to 2017.

Bus bar 9 flag INFINITI_BUSBAR_NO_9

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 10 flag INFINITI_BUSBAR_NO_10

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 11 flag INFINITI_BUSBAR_NO_11

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Bus bar 12 flag INFINITI_BUSBAR_NO_12

  • Request22 91 CC
  • Service 22DID 91CC
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 1 flag INFINITI_CELL_NUMBER_1

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 255 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 1 state of health flag INFINITI_SOH_CELL_1

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 255 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 1 voltage INFINITI_HVBAT_CELL_1_V

  • Request22 90 21
  • Service 22DID 9021
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 2 flag INFINITI_CELL_NUMBER_2

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 254 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 2 state of health flag INFINITI_SOH_CELL_2

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 254 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 2 voltage INFINITI_HVBAT_CELL_2_V

  • Request22 90 22
  • Service 22DID 9022
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 3 flag INFINITI_CELL_NUMBER_3

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 253 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 3 state of health flag INFINITI_SOH_CELL_3

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 253 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 3 voltage INFINITI_HVBAT_CELL_3_V

  • Request22 90 23
  • Service 22DID 9023
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 4 flag INFINITI_CELL_NUMBER_4

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 252 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 4 state of health flag INFINITI_SOH_CELL_4

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 252 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 4 voltage INFINITI_HVBAT_CELL_4_V

  • Request22 90 24
  • Service 22DID 9024
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 5 flag INFINITI_CELL_NUMBER_5

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 251 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 5 state of health flag INFINITI_SOH_CELL_5

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 251 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 5 voltage INFINITI_HVBAT_CELL_5_V

  • Request22 90 25
  • Service 22DID 9025
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 6 flag INFINITI_CELL_NUMBER_6

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 250 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 6 state of health flag INFINITI_SOH_CELL_6

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 250 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 6 voltage INFINITI_HVBAT_CELL_6_V

  • Request22 90 26
  • Service 22DID 9026
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 7 flag INFINITI_CELL_NUMBER_7

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 249 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 7 state of health flag INFINITI_SOH_CELL_7

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 249 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 7 voltage INFINITI_HVBAT_CELL_7_V

  • Request22 90 27
  • Service 22DID 9027
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 8 flag INFINITI_CELL_NUMBER_8

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 248 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 8 state of health flag INFINITI_SOH_CELL_8

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 248 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 8 voltage INFINITI_HVBAT_CELL_8_V

  • Request22 90 28
  • Service 22DID 9028
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 9 flag INFINITI_CELL_NUMBER_9

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 247 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 9 state of health flag INFINITI_SOH_CELL_9

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 247 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 9 voltage INFINITI_HVBAT_CELL_9_V

  • Request22 90 29
  • Service 22DID 9029
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 10 flag INFINITI_CELL_NUMBER_10

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 246 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 10 state of health flag INFINITI_SOH_CELL_10

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 246 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 10 voltage INFINITI_HVBAT_CELL_10_V

  • Request22 90 2A
  • Service 22DID 902A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 11 flag INFINITI_CELL_NUMBER_11

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 245 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 11 state of health flag INFINITI_SOH_CELL_11

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 245 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 11 voltage INFINITI_HVBAT_CELL_11_V

  • Request22 90 2B
  • Service 22DID 902B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 12 flag INFINITI_CELL_NUMBER_12

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 244 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 12 state of health flag INFINITI_SOH_CELL_12

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 244 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 12 voltage INFINITI_HVBAT_CELL_12_V

  • Request22 90 2C
  • Service 22DID 902C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 13 flag INFINITI_CELL_NUMBER_13

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 243 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 13 state of health flag INFINITI_SOH_CELL_13

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 243 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 13 voltage INFINITI_HVBAT_CELL_13_V

  • Request22 90 2D
  • Service 22DID 902D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 14 flag INFINITI_CELL_NUMBER_14

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 242 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 14 state of health flag INFINITI_SOH_CELL_14

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 242 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 14 voltage INFINITI_HVBAT_CELL_14_V

  • Request22 90 2E
  • Service 22DID 902E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 15 flag INFINITI_CELL_NUMBER_15

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 241 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 15 state of health flag INFINITI_SOH_CELL_15

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 241 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 15 voltage INFINITI_HVBAT_CELL_15_V

  • Request22 90 2F
  • Service 22DID 902F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 16 flag INFINITI_CELL_NUMBER_16

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 240 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 16 state of health flag INFINITI_SOH_CELL_16

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 240 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 16 voltage INFINITI_HVBAT_CELL_16_V

  • Request22 90 30
  • Service 22DID 9030
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 17 flag INFINITI_CELL_NUMBER_17

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 239 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 17 state of health flag INFINITI_SOH_CELL_17

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 239 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 17 voltage INFINITI_HVBAT_CELL_17_V

  • Request22 90 31
  • Service 22DID 9031
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 18 flag INFINITI_CELL_NUMBER_18

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 238 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 18 state of health flag INFINITI_SOH_CELL_18

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 238 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 18 voltage INFINITI_HVBAT_CELL_18_V

  • Request22 90 32
  • Service 22DID 9032
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 19 flag INFINITI_CELL_NUMBER_19

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 19 state of health flag INFINITI_SOH_CELL_19

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 237 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 19 voltage INFINITI_HVBAT_CELL_19_V

  • Request22 90 33
  • Service 22DID 9033
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 20 flag INFINITI_CELL_NUMBER_20

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 20 state of health flag INFINITI_SOH_CELL_20

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 236 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 20 voltage INFINITI_HVBAT_CELL_20_V

  • Request22 90 34
  • Service 22DID 9034
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 21 flag INFINITI_CELL_NUMBER_21

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 21 state of health flag INFINITI_SOH_CELL_21

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 235 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 21 voltage INFINITI_HVBAT_CELL_21_V

  • Request22 90 35
  • Service 22DID 9035
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 22 flag INFINITI_CELL_NUMBER_22

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 22 state of health flag INFINITI_SOH_CELL_22

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 234 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 22 voltage INFINITI_HVBAT_CELL_22_V

  • Request22 90 36
  • Service 22DID 9036
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 23 flag INFINITI_CELL_NUMBER_23

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 23 state of health flag INFINITI_SOH_CELL_23

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 233 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 23 voltage INFINITI_HVBAT_CELL_23_V

  • Request22 90 37
  • Service 22DID 9037
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 24 flag INFINITI_CELL_NUMBER_24

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 24 state of health flag INFINITI_SOH_CELL_24

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 232 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 24 voltage INFINITI_HVBAT_CELL_24_V

  • Request22 90 38
  • Service 22DID 9038
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 25 flag INFINITI_CELL_NUMBER_25

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 231 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 25 state of health flag INFINITI_SOH_CELL_25

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 231 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 25 voltage INFINITI_HVBAT_CELL_25_V

  • Request22 90 39
  • Service 22DID 9039
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 26 flag INFINITI_CELL_NUMBER_26

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 230 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 26 state of health flag INFINITI_SOH_CELL_26

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 230 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 26 voltage INFINITI_HVBAT_CELL_26_V

  • Request22 90 3A
  • Service 22DID 903A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 27 flag INFINITI_CELL_NUMBER_27

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 229 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 27 state of health flag INFINITI_SOH_CELL_27

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 229 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 27 voltage INFINITI_HVBAT_CELL_27_V

  • Request22 90 3B
  • Service 22DID 903B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 28 flag INFINITI_CELL_NUMBER_28

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 228 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 28 state of health flag INFINITI_SOH_CELL_28

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 228 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 28 voltage INFINITI_HVBAT_CELL_28_V

  • Request22 90 3C
  • Service 22DID 903C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 29 flag INFINITI_CELL_NUMBER_29

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 227 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 29 state of health flag INFINITI_SOH_CELL_29

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 227 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 29 voltage INFINITI_HVBAT_CELL_29_V

  • Request22 90 3D
  • Service 22DID 903D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 30 flag INFINITI_CELL_NUMBER_30

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 226 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 30 state of health flag INFINITI_SOH_CELL_30

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 226 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 30 voltage INFINITI_HVBAT_CELL_30_V

  • Request22 90 3E
  • Service 22DID 903E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 31 flag INFINITI_CELL_NUMBER_31

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 225 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 31 state of health flag INFINITI_SOH_CELL_31

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 225 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 31 voltage INFINITI_HVBAT_CELL_31_V

  • Request22 90 3F
  • Service 22DID 903F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 32 flag INFINITI_CELL_NUMBER_32

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 224 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 32 state of health flag INFINITI_SOH_CELL_32

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 224 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 32 voltage INFINITI_HVBAT_CELL_32_V

  • Request22 90 41
  • Service 22DID 9041
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 33 flag INFINITI_CELL_NUMBER_33

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 223 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 33 state of health flag INFINITI_SOH_CELL_33

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 223 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 33 voltage INFINITI_HVBAT_CELL_33_V

  • Request22 90 42
  • Service 22DID 9042
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 34 flag INFINITI_CELL_NUMBER_34

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 222 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 34 state of health flag INFINITI_SOH_CELL_34

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 222 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 34 voltage INFINITI_HVBAT_CELL_34_V

  • Request22 90 43
  • Service 22DID 9043
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 35 flag INFINITI_CELL_NUMBER_35

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 221 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 35 state of health flag INFINITI_SOH_CELL_35

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 221 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 35 voltage INFINITI_HVBAT_CELL_35_V

  • Request22 90 44
  • Service 22DID 9044
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 36 flag INFINITI_CELL_NUMBER_36

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 220 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 36 state of health flag INFINITI_SOH_CELL_36

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 220 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 36 voltage INFINITI_HVBAT_CELL_36_V

  • Request22 90 45
  • Service 22DID 9045
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 37 flag INFINITI_CELL_NUMBER_37

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 219 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 37 state of health flag INFINITI_SOH_CELL_37

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 219 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 37 voltage INFINITI_HVBAT_CELL_37_V

  • Request22 90 46
  • Service 22DID 9046
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 38 flag INFINITI_CELL_NUMBER_38

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 218 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 38 state of health flag INFINITI_SOH_CELL_38

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 218 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 38 voltage INFINITI_HVBAT_CELL_38_V

  • Request22 90 47
  • Service 22DID 9047
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 39 flag INFINITI_CELL_NUMBER_39

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 217 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 39 state of health flag INFINITI_SOH_CELL_39

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 217 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 39 voltage INFINITI_HVBAT_CELL_39_V

  • Request22 90 48
  • Service 22DID 9048
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 40 flag INFINITI_CELL_NUMBER_40

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 216 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 40 state of health flag INFINITI_SOH_CELL_40

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 216 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 40 voltage INFINITI_HVBAT_CELL_40_V

  • Request22 90 49
  • Service 22DID 9049
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 41 flag INFINITI_CELL_NUMBER_41

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 215 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 41 state of health flag INFINITI_SOH_CELL_41

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 215 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 41 voltage INFINITI_HVBAT_CELL_41_V

  • Request22 90 4A
  • Service 22DID 904A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 42 flag INFINITI_CELL_NUMBER_42

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 214 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 42 state of health flag INFINITI_SOH_CELL_42

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 214 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 42 voltage INFINITI_HVBAT_CELL_42_V

  • Request22 90 4B
  • Service 22DID 904B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 43 flag INFINITI_CELL_NUMBER_43

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 213 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 43 state of health flag INFINITI_SOH_CELL_43

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 213 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 43 voltage INFINITI_HVBAT_CELL_43_V

  • Request22 90 4C
  • Service 22DID 904C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 44 flag INFINITI_CELL_NUMBER_44

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 212 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 44 state of health flag INFINITI_SOH_CELL_44

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 212 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 44 voltage INFINITI_HVBAT_CELL_44_V

  • Request22 90 4D
  • Service 22DID 904D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 45 flag INFINITI_CELL_NUMBER_45

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 211 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 45 state of health flag INFINITI_SOH_CELL_45

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 211 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 45 voltage INFINITI_HVBAT_CELL_45_V

  • Request22 90 4E
  • Service 22DID 904E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 46 flag INFINITI_CELL_NUMBER_46

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 210 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 46 state of health flag INFINITI_SOH_CELL_46

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 210 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 46 voltage INFINITI_HVBAT_CELL_46_V

  • Request22 90 4F
  • Service 22DID 904F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 47 flag INFINITI_CELL_NUMBER_47

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 209 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 47 state of health flag INFINITI_SOH_CELL_47

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 209 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 47 voltage INFINITI_HVBAT_CELL_47_V

  • Request22 90 50
  • Service 22DID 9050
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 48 flag INFINITI_CELL_NUMBER_48

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 208 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 48 state of health flag INFINITI_SOH_CELL_48

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 208 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 48 voltage INFINITI_HVBAT_CELL_48_V

  • Request22 90 51
  • Service 22DID 9051
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 49 flag INFINITI_CELL_NUMBER_49

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 49 state of health flag INFINITI_SOH_CELL_49

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 49 voltage INFINITI_HVBAT_CELL_49_V

  • Request22 90 52
  • Service 22DID 9052
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 50 flag INFINITI_CELL_NUMBER_50

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 50 state of health flag INFINITI_SOH_CELL_50

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 206 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 50 voltage INFINITI_HVBAT_CELL_50_V

  • Request22 90 53
  • Service 22DID 9053
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 51 flag INFINITI_CELL_NUMBER_51

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 51 state of health flag INFINITI_SOH_CELL_51

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 205 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 51 voltage INFINITI_HVBAT_CELL_51_V

  • Request22 90 54
  • Service 22DID 9054
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 52 flag INFINITI_CELL_NUMBER_52

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 52 state of health flag INFINITI_SOH_CELL_52

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 204 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 52 voltage INFINITI_HVBAT_CELL_52_V

  • Request22 90 55
  • Service 22DID 9055
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 53 flag INFINITI_CELL_NUMBER_53

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 203 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 53 state of health flag INFINITI_SOH_CELL_53

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 203 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 53 voltage INFINITI_HVBAT_CELL_53_V

  • Request22 90 56
  • Service 22DID 9056
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 54 flag INFINITI_CELL_NUMBER_54

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 202 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 54 state of health flag INFINITI_SOH_CELL_54

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 202 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 54 voltage INFINITI_HVBAT_CELL_54_V

  • Request22 90 57
  • Service 22DID 9057
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 55 flag INFINITI_CELL_NUMBER_55

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 201 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 55 state of health flag INFINITI_SOH_CELL_55

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 201 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 55 voltage INFINITI_HVBAT_CELL_55_V

  • Request22 90 58
  • Service 22DID 9058
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 56 flag INFINITI_CELL_NUMBER_56

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 200 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 56 state of health flag INFINITI_SOH_CELL_56

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 200 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 56 voltage INFINITI_HVBAT_CELL_56_V

  • Request22 90 59
  • Service 22DID 9059
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 57 flag INFINITI_CELL_NUMBER_57

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 199 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 57 state of health flag INFINITI_SOH_CELL_57

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 199 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 57 voltage INFINITI_HVBAT_CELL_57_V

  • Request22 90 5A
  • Service 22DID 905A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 58 flag INFINITI_CELL_NUMBER_58

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 198 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 58 state of health flag INFINITI_SOH_CELL_58

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 198 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 58 voltage INFINITI_HVBAT_CELL_58_V

  • Request22 90 5B
  • Service 22DID 905B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 59 flag INFINITI_CELL_NUMBER_59

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 197 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 59 state of health flag INFINITI_SOH_CELL_59

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 197 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 59 voltage INFINITI_HVBAT_CELL_59_V

  • Request22 90 5C
  • Service 22DID 905C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 60 flag INFINITI_CELL_NUMBER_60

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 196 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 60 state of health flag INFINITI_SOH_CELL_60

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 196 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 60 voltage INFINITI_HVBAT_CELL_60_V

  • Request22 90 5D
  • Service 22DID 905D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 61 flag INFINITI_CELL_NUMBER_61

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 195 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 61 state of health flag INFINITI_SOH_CELL_61

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 195 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 61 voltage INFINITI_HVBAT_CELL_61_V

  • Request22 90 5E
  • Service 22DID 905E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 62 flag INFINITI_CELL_NUMBER_62

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 194 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 62 state of health flag INFINITI_SOH_CELL_62

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 194 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 62 voltage INFINITI_HVBAT_CELL_62_V

  • Request22 90 5F
  • Service 22DID 905F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 63 flag INFINITI_CELL_NUMBER_63

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 193 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 63 state of health flag INFINITI_SOH_CELL_63

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 193 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 63 voltage INFINITI_HVBAT_CELL_63_V

  • Request22 90 61
  • Service 22DID 9061
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 64 flag INFINITI_CELL_NUMBER_64

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 192 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 64 state of health flag INFINITI_SOH_CELL_64

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 192 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 64 voltage INFINITI_HVBAT_CELL_64_V

  • Request22 90 62
  • Service 22DID 9062
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 65 flag INFINITI_CELL_NUMBER_65

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 191 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 65 state of health flag INFINITI_SOH_CELL_65

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 191 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 65 voltage INFINITI_HVBAT_CELL_65_V

  • Request22 90 63
  • Service 22DID 9063
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 66 flag INFINITI_CELL_NUMBER_66

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 66 state of health flag INFINITI_SOH_CELL_66

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 190 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 66 voltage INFINITI_HVBAT_CELL_66_V

  • Request22 90 64
  • Service 22DID 9064
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 67 flag INFINITI_CELL_NUMBER_67

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 189 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 67 state of health flag INFINITI_SOH_CELL_67

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 189 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 67 voltage INFINITI_HVBAT_CELL_67_V

  • Request22 90 65
  • Service 22DID 9065
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 68 flag INFINITI_CELL_NUMBER_68

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 188 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 68 state of health flag INFINITI_SOH_CELL_68

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 188 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 68 voltage INFINITI_HVBAT_CELL_68_V

  • Request22 90 66
  • Service 22DID 9066
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 69 flag INFINITI_CELL_NUMBER_69

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 187 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 69 state of health flag INFINITI_SOH_CELL_69

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 187 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 69 voltage INFINITI_HVBAT_CELL_69_V

  • Request22 90 67
  • Service 22DID 9067
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 70 flag INFINITI_CELL_NUMBER_70

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 70 state of health flag INFINITI_SOH_CELL_70

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 186 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 70 voltage INFINITI_HVBAT_CELL_70_V

  • Request22 90 68
  • Service 22DID 9068
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 71 flag INFINITI_CELL_NUMBER_71

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 185 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 71 state of health flag INFINITI_SOH_CELL_71

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 185 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 71 voltage INFINITI_HVBAT_CELL_71_V

  • Request22 90 69
  • Service 22DID 9069
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 72 flag INFINITI_CELL_NUMBER_72

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 184 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 72 state of health flag INFINITI_SOH_CELL_72

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 184 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 72 voltage INFINITI_HVBAT_CELL_72_V

  • Request22 90 6A
  • Service 22DID 906A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 73 flag INFINITI_CELL_NUMBER_73

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 73 state of health flag INFINITI_SOH_CELL_73

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 73 voltage INFINITI_HVBAT_CELL_73_V

  • Request22 90 6B
  • Service 22DID 906B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 74 flag INFINITI_CELL_NUMBER_74

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 74 state of health flag INFINITI_SOH_CELL_74

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 74 voltage INFINITI_HVBAT_CELL_74_V

  • Request22 90 6C
  • Service 22DID 906C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 75 flag INFINITI_CELL_NUMBER_75

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 75 state of health flag INFINITI_SOH_CELL_75

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 75 voltage INFINITI_HVBAT_CELL_75_V

  • Request22 90 6D
  • Service 22DID 906D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 76 flag INFINITI_CELL_NUMBER_76

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 76 state of health flag INFINITI_SOH_CELL_76

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 76 voltage INFINITI_HVBAT_CELL_76_V

  • Request22 90 6E
  • Service 22DID 906E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 77 flag INFINITI_CELL_NUMBER_77

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 77 state of health flag INFINITI_SOH_CELL_77

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 77 voltage INFINITI_HVBAT_CELL_77_V

  • Request22 90 6F
  • Service 22DID 906F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 78 flag INFINITI_CELL_NUMBER_78

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 177 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 78 state of health flag INFINITI_SOH_CELL_78

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 78 voltage INFINITI_HVBAT_CELL_78_V

  • Request22 90 70
  • Service 22DID 9070
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 79 state of health flag INFINITI_SOH_CELL_79

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 177 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 79 voltage INFINITI_HVBAT_CELL_79_V

  • Request22 90 71
  • Service 22DID 9071
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 80 flag INFINITI_CELL_NUMBER_80

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 176 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 80 state of health flag INFINITI_SOH_CELL_80

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 176 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 80 voltage INFINITI_HVBAT_CELL_80_V

  • Request22 90 72
  • Service 22DID 9072
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 81 flag INFINITI_CELL_NUMBER_81

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 81 state of health flag INFINITI_SOH_CELL_81

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 81 voltage INFINITI_HVBAT_CELL_81_V

  • Request22 90 73
  • Service 22DID 9073
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 82 flag INFINITI_CELL_NUMBER_82

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 82 state of health flag INFINITI_SOH_CELL_82

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 174 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 82 voltage INFINITI_HVBAT_CELL_82_V

  • Request22 90 74
  • Service 22DID 9074
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 83 flag INFINITI_CELL_NUMBER_83

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 83 state of health flag INFINITI_SOH_CELL_83

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 173 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 83 voltage INFINITI_HVBAT_CELL_83_V

  • Request22 90 75
  • Service 22DID 9075
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 84 flag INFINITI_CELL_NUMBER_84

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 84 state of health flag INFINITI_SOH_CELL_84

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 172 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 84 voltage INFINITI_HVBAT_CELL_84_V

  • Request22 90 76
  • Service 22DID 9076
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 85 flag INFINITI_CELL_NUMBER_85

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 85 state of health flag INFINITI_SOH_CELL_85

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 171 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 85 voltage INFINITI_HVBAT_CELL_85_V

  • Request22 90 77
  • Service 22DID 9077
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 86 flag INFINITI_CELL_NUMBER_86

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 86 state of health flag INFINITI_SOH_CELL_86

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 170 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 86 voltage INFINITI_HVBAT_CELL_86_V

  • Request22 90 78
  • Service 22DID 9078
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 87 flag INFINITI_CELL_NUMBER_87

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 169 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 87 state of health flag INFINITI_SOH_CELL_87

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 169 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 87 voltage INFINITI_HVBAT_CELL_87_V

  • Request22 90 79
  • Service 22DID 9079
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 88 flag INFINITI_CELL_NUMBER_88

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 168 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 88 state of health flag INFINITI_SOH_CELL_88

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 168 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 88 voltage INFINITI_HVBAT_CELL_88_V

  • Request22 90 7A
  • Service 22DID 907A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 89 flag INFINITI_CELL_NUMBER_89

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 167 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 89 state of health flag INFINITI_SOH_CELL_89

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 167 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 89 voltage INFINITI_HVBAT_CELL_89_V

  • Request22 90 7B
  • Service 22DID 907B
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 90 flag INFINITI_CELL_NUMBER_90

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 166 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 90 state of health flag INFINITI_SOH_CELL_90

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 166 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 90 voltage INFINITI_HVBAT_CELL_90_V

  • Request22 90 7C
  • Service 22DID 907C
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 91 flag INFINITI_CELL_NUMBER_91

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 165 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 91 state of health flag INFINITI_SOH_CELL_91

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 165 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 91 voltage INFINITI_HVBAT_CELL_91_V

  • Request22 90 7D
  • Service 22DID 907D
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 92 flag INFINITI_CELL_NUMBER_92

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 164 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 92 state of health flag INFINITI_SOH_CELL_92

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 164 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 92 voltage INFINITI_HVBAT_CELL_92_V

  • Request22 90 7E
  • Service 22DID 907E
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 93 flag INFINITI_CELL_NUMBER_93

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 163 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 93 state of health flag INFINITI_SOH_CELL_93

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 163 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 93 voltage INFINITI_HVBAT_CELL_93_V

  • Request22 90 7F
  • Service 22DID 907F
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 94 flag INFINITI_CELL_NUMBER_94

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 162 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 94 state of health flag INFINITI_SOH_CELL_94

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 162 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 94 voltage INFINITI_HVBAT_CELL_94_V

  • Request22 90 81
  • Service 22DID 9081
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 95 flag INFINITI_CELL_NUMBER_95

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 161 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 95 state of health flag INFINITI_SOH_CELL_95

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 161 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 95 voltage INFINITI_HVBAT_CELL_95_V

  • Request22 90 82
  • Service 22DID 9082
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell 96 flag INFINITI_CELL_NUMBER_96

  • Request22 92 56
  • Service 22DID 9256
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 160 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 96 state of health flag INFINITI_SOH_CELL_96

  • Request22 92 7A
  • Service 22DID 927A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 160 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cell 96 voltage INFINITI_HVBAT_CELL_96_V

  • Request22 90 83
  • Service 22DID 9083
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cell with the highest voltage INFINITI_CELL_HIGHEST_V

  • Request22 90 08
  • Service 22DID 9008
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val + 1)
Range
0 to 256
Unit
Number

In testing for 2003 to 2017.

Cell with the lowest voltage INFINITI_CELL_LOWEST_V

  • Request22 90 0A
  • Service 22DID 900A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val + 1)
Range
0 to 256
Unit
Number

In testing for 2003 to 2017.

Cells overvoltage INFINITI_CELLS_OVERVOLAGE

  • Request22 92 16
  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Cells undervoltage INFINITI_CELLS_UNDERVOLTAGE

  • Request22 92 16
  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Charging mode INFINITI_CHARGE_MODE

Pelican can show this parameter as the charging state.

  • Request22 11 4E
  • Service 22DID 114E
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0NOT_CHARGINGNot charging
1CHARGING_L1L1 charging (100-120V)
2CHARGING_L2L2 charging (200-240V)
3CHARGING_L3L3 quick charging

In testing for 2003 to 2017.

Charging power INFINITI_CHRG_PWR

Power entering the high voltage battery while charging.

  • Request22 12 36
  • Service 22DID 1236
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100)
Range
0 to 6553500 W
Unit
W

In testing for 2003 to 2017.

Computer power supply INFINITI_COMPUTER_POWER_SUP

  • Request22 90 11
  • Service 22DID 9011
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Cumulative energy when discharging INFINITI_CUM_ENERGY

  • Request22 92 45
  • Service 22DID 9245
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-2147483 to 2147483 kWh
Unit
kWh

In testing for 2003 to 2017.

DC battery capacity INFINITI_DC_BAT_CAP

  • Request22 91 C8
  • Service 22DID 91C8
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 1000)
Range
0 to 16777 kWh
Unit
kWh

In testing for 2003 to 2017.

DC battery current INFINITI_DC_BAT_CURRENT

  • Request22 21 CC
  • Service 22DID 21CC
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × -1 ÷ 4 + 500)
Range
-15883 to 500 A
Unit
A

In testing for 2003 to 2017.

DC battery state of charge INFINITI_DC_BAT_ST_CHG

  • Request22 90 02
  • Service 22DID 9002
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2003 to 2017.

DC battery state of health INFINITI_DC_BAT_ST_HEALTH

  • Request22 90 03
  • Service 22DID 9003
  • ModuleDADA → DAF1DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2003 to 2017.

DC battery voltage INFINITI_DC_BAT_V

  • Request22 20 FE
  • Service 22DID 20FE
  • ModuleDADA → DAF1DA
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2003 to 2017.

EVAP pressure sensor voltage INFINITI_EVAP_P_SENS_V

  • Request22 11 15
  • Service 22DID 1115
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 2003 to 2017.

Exhaust gas recirculation temperature sensor voltage INFINITI_EGR_T_SENS_V

  • Request22 11 05
  • Service 22DID 1105
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 2003 to 2017.

Fan unit INFINITI_FAN_UNIT

  • Request22 91 EF
  • Service 22DID 91EF
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2003 to 2017.

Fan unit feed INFINITI_FAN_UNIT_FEED

  • Request22 92 5A
  • Service 22DID 925A
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 Hz
Unit
Hz

In testing for 2003 to 2017.

Fault finding version INFINITI_FAULT_FINDING

  • Request22 F1 A0
  • Service 22DID F1A0
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2017.

Fuel pressure sensor voltage INFINITI_FUEL_P_SENS_V

  • Request22 12 0C
  • Service 22DID 120C
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 4 ÷ 13107)
Range
0 to 20 V
Unit
V

In testing for 2003 to 2017.

Fuel rail temperature sensor voltage INFINITI_FUEL_RAIL_T_SENS_V

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2017.

Fuel tank temperature sensor voltage INFINITI_FUEL_TANK_T_SENS_V

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2003 to 2017.

High voltage battery capacity INFINITI_HVBAT_CAP

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 280 to 303 of the reply, 24 bits.

Formula
(val ÷ 10000)
Range
0 to 1000 Ah
Unit
Ah

In testing for 2003 to 2017.

High voltage battery capacity INFINITI_HVBAT_CAP_PRE18

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 264 to 287 of the reply, 24 bits.

Formula
(val ÷ 10000)
Range
0 to 1000 Ah
Unit
Ah

In testing for 2003 to 2017.

High voltage battery charge INFINITI_HVBAT_SOC

Pelican can show this parameter as the state of charge.

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 248 to 271 of the reply, 24 bits.

Formula
(val ÷ 8190 − 17)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2017.

High voltage battery charge INFINITI_HVBAT_SOC_PRE18

Pelican can show this parameter as the state of charge.

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 232 to 255 of the reply, 24 bits.

Formula
(val ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2017.

High voltage battery health INFINITI_HVBAT_SOH

When the battery is new, its health should be ~100%.

Pelican can show this parameter as the state of health.

  • Request21 61
  • Service 21PID 61
  • Module79B → 7BB
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2003 to 2017.

High voltage battery voltage INFINITI_HVBAT_VOLT

Pelican can show this parameter as the traction battery voltage.

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2003 to 2017.

High voltage battery voltage INFINITI_HVBAT_VOLT_PRE18

Pelican can show this parameter as the traction battery voltage.

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2003 to 2017.

Highest cell voltage level INFINITI_HIGHEST_CELL_V_LEVEL

  • Request22 90 07
  • Service 22DID 9007
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

HV battery current INFINITI_HVBAT_I

Pelican can show this parameter as the traction battery current.

  • Request22 12 48
  • Service 22DID 1248
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383.5 A
Unit
A

In testing for 2003 to 2017.

HV battery pack 1 temperature INFINITI_HVBAT_PACK_1_T

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2003 to 2017.

HV battery pack 2 temperature INFINITI_HVBAT_PACK_2_T

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2003 to 2017.

HV battery pack 4 temperature INFINITI_HVBAT_PACK_4_T

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2003 to 2017.

HV battery pack 5 temperature INFINITI_HVBAT_PACK_5_T

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2003 to 2017.

HV battery pack voltage INFINITI_HVBAT_PACK_V

Pelican can show this parameter as the traction battery voltage.

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,536 to 1,551 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 2003 to 2017.

HV bus voltage INFINITI_HVBAT_BUS_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,552 to 1,567 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 2003 to 2017.

L1/L2 charge port plug state INFINITI_CHARGE_PLUG

Pelican can show this parameter as the plug state.

  • Request22 12 34
  • Service 22DID 1234
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0UNPLUGGEDNot plugged in
1PLUGGED_PARTIALPartially plugged in
2PLUGGEDPlugged in

In testing for 2003 to 2017.

Lowest cell voltage level INFINITI_LOWEST_CELL_V_LEVEL

  • Request22 90 09
  • Service 22DID 9009
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.000976563)
Range
0 to 63.99 V
Unit
V

In testing for 2003 to 2017.

Manifold pressure sensor voltage INFINITI_MANIFOLD_P_SENS_V

  • Request22 11 2A
  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 2003 to 2017.

Maximum cell voltage INFINITI_MAX_CELL_V

  • Request21 03
  • Service 21PID 03
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 4.5 V
Unit
V

In testing for 2003 to 2017.

Minimum cell voltage INFINITI_MIN_CELL_V

  • Request21 03
  • Service 21PID 03
  • Module79B → 7BB
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 4.5 V
Unit
V

In testing for 2003 to 2017.

Module 1 temperature INFINITI_MODULE_T_NUMBER_1

  • Request22 91 31
  • Service 22DID 9131
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 1 temperature sensor flag INFINITI_T_SENS_MODULE_N_1

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 2 temperature INFINITI_MODULE_T_NUMBER_2

  • Request22 91 32
  • Service 22DID 9132
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 2 temperature sensor flag INFINITI_T_SENS_MODULE_N_2

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 3 temperature INFINITI_MODULE_T_NUMBER_3

  • Request22 91 33
  • Service 22DID 9133
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 3 temperature sensor flag INFINITI_T_SENS_MODULE_N_3

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 4 temperature INFINITI_MODULE_T_NUMBER_4

  • Request22 91 34
  • Service 22DID 9134
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 4 temperature sensor flag INFINITI_T_SENS_MODULE_N_4

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 5 temperature INFINITI_MODULE_T_NUMBER_5

  • Request22 91 35
  • Service 22DID 9135
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 5 temperature sensor flag INFINITI_T_SENS_MODULE_N_5

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 6 temperature INFINITI_MODULE_T_NUMBER_6

  • Request22 91 36
  • Service 22DID 9136
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 6 temperature sensor flag INFINITI_T_SENS_MODULE_N_6

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 7 temperature INFINITI_MODULE_T_NUMBER_7

  • Request22 91 37
  • Service 22DID 9137
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 7 temperature sensor flag INFINITI_T_SENS_MODULE_N_7

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 8 temperature INFINITI_MODULE_T_NUMBER_8

  • Request22 91 38
  • Service 22DID 9138
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 8 temperature sensor flag INFINITI_T_SENS_MODULE_N_8

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 9 temperature INFINITI_MODULE_T_NUMBER_9

  • Request22 91 39
  • Service 22DID 9139
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 9 temperature sensor flag INFINITI_T_SENS_MODULE_N_9

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 10 temperature INFINITI_MODULE_T_NUMBER_10

  • Request22 91 3A
  • Service 22DID 913A
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 10 temperature sensor flag INFINITI_T_SENS_MODULE_N_10

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 11 temperature INFINITI_MODULE_T_NUMBER_11

  • Request22 91 3B
  • Service 22DID 913B
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 11 temperature sensor flag INFINITI_T_SENS_MODULE_N_11

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module 12 temperature INFINITI_MODULE_T_NUMBER_12

  • Request22 91 3C
  • Service 22DID 913C
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Module 12 temperature sensor flag INFINITI_T_SENS_MODULE_N_12

  • Request22 91 2F
  • Service 22DID 912F
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Module with the minimum temperature INFINITI_MODULE_MIN_T

  • Request22 92 42
  • Service 22DID 9242
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2017.

Motor-driven fan unit request INFINITI_MOTOR_DRIVEN_FAN

  • Request22 91 C9
  • Service 22DID 91C9
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 %
Unit
%

In testing for 2003 to 2017.

Open circuit voltage INFINITI_OPEN_CIRCUIT_V

  • Request22 90 05
  • Service 22DID 9005
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2003 to 2017.

Refrigerant fluid sensor voltage INFINITI_REFRIGERANT_FLUID_V

  • Request22 12 23
  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Roll-over sensor voltage INFINITI_ROLL_OVER_SENS_V

  • Request22 12 1F
  • Service 22DID 121F
  • ModuleDA18 → 18
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Secondary battery management board 1 INFINITI_SECONDARY_BMS_NO_1

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 2 INFINITI_SECONDARY_BMS_NO_2

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 3 INFINITI_SECONDARY_BMS_NO_3

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 29 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 4 INFINITI_SECONDARY_BMS_NO_4

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 28 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 5 INFINITI_SECONDARY_BMS_NO_5

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 27 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 6 INFINITI_SECONDARY_BMS_NO_6

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 26 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 7 INFINITI_SECONDARY_BMS_NO_7

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 8 INFINITI_SECONDARY_BMS_NO_8

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 24 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 9 INFINITI_SECONDARY_BMS_NO_9

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 23 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 10 INFINITI_SECONDARY_BMS_NO_10

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 11 INFINITI_SECONDARY_BMS_NO_11

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 21 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Secondary battery management board 12 INFINITI_SECONDARY_BMS_NO_12

  • Request22 91 29
  • Service 22DID 9129
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 20 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

State of charge, as the dash shows it INFINITI_SOC_DASH

Pelican can show this parameter as the state of charge.

  • Request22 0E 2D
  • Service 22DID 0E2D
  • Module743 → 763
  • Every30 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2003 to 2017.

Throttle position sensor 1, volts INFINITI_THROTTLE_POS_SENS_1

  • Request22 12 0F
  • Service 22DID 120F
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Throttle position sensor 2, volts INFINITI_THROTTLE_POS_SENS_2

  • Request22 12 10
  • Service 22DID 1210
  • ModuleDA18 → 18
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Traction battery compartment temperature INFINITI_TRACTION_BAT_T

  • Request22 90 12
  • Service 22DID 9012
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Traction battery current INFINITI_TRACTION_BAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Request22 92 84
  • Service 22DID 9284
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val × -1 ÷ 1000)
Range
-2147483 to 2147483 A
Unit
A

In testing for 2003 to 2017.

Traction battery input water temperature INFINITI_TRACTION_BAT_INPUT_T

  • Request22 91 CD
  • Service 22DID 91CD
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Traction battery interlock INFINITI_TRACTION_BAT_INTERLOCK

  • Request22 91 F7
  • Service 22DID 91F7
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2017.

Traction battery maximum temperature INFINITI_TRACTION_BAT_MAX_T

  • Request22 90 14
  • Service 22DID 9014
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Traction battery minimum temperature INFINITI_TRACTION_BAT_MIN_T

  • Request22 90 13
  • Service 22DID 9013
  • ModuleDADB → DAF1DB
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 40)
Range
-40 to 4055 °C
Unit
°C

In testing for 2003 to 2017.

Traction battery overcurrent INFINITI_TRACTION_BAT_OVERCURRENT

  • Request22 92 16
  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Traction battery overheating INFINITI_TRACTION_BAT

  • Request22 92 16
  • Service 22DID 9216
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2003 to 2017.

Traction battery service plug interlock INFINITI_TRACTION_BAT_SERVICE

  • Request22 91 F6
  • Service 22DID 91F6
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2003 to 2017.

Traction battery state of charge INFINITI_TRACTION_BAT_SOC

Pelican can show this parameter as the state of charge.

  • Request22 90 01
  • Service 22DID 9001
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 3)
Range
-3 to 652 %
Unit
%

In testing for 2003 to 2017.

Traction battery total mileage INFINITI_TRACTION_BAT_TOT

  • Request22 91 CF
  • Service 22DID 91CF
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 32 + 67108864)
Range
0 to 134217727 km
Unit
km

In testing for 2003 to 2017.

Traction battery voltage INFINITI_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 90 06
  • Service 22DID 9006
  • ModuleDADB → DAF1DB
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 1000 V
Unit
V

In testing for 2003 to 2017.

Upstream oxygen sensor voltage INFINITI_UP_OXYGEN_SENS_V

  • Request22 12 25
  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 200)
Range
0 to 327 V
Unit
V

In testing for 2003 to 2017.

Battery › Cells

HV battery cell 1 voltage INFINITI_HVBAT_CELL_1_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 2 voltage INFINITI_HVBAT_CELL_2_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 3 voltage INFINITI_HVBAT_CELL_3_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 4 voltage INFINITI_HVBAT_CELL_4_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 5 voltage INFINITI_HVBAT_CELL_5_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 6 voltage INFINITI_HVBAT_CELL_6_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 7 voltage INFINITI_HVBAT_CELL_7_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 8 voltage INFINITI_HVBAT_CELL_8_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 9 voltage INFINITI_HVBAT_CELL_9_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 10 voltage INFINITI_HVBAT_CELL_10_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 11 voltage INFINITI_HVBAT_CELL_11_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 12 voltage INFINITI_HVBAT_CELL_12_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 13 voltage INFINITI_HVBAT_CELL_13_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 14 voltage INFINITI_HVBAT_CELL_14_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 15 voltage INFINITI_HVBAT_CELL_15_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 16 voltage INFINITI_HVBAT_CELL_16_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 17 voltage INFINITI_HVBAT_CELL_17_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 18 voltage INFINITI_HVBAT_CELL_18_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 19 voltage INFINITI_HVBAT_CELL_19_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 20 voltage INFINITI_HVBAT_CELL_20_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 21 voltage INFINITI_HVBAT_CELL_21_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 22 voltage INFINITI_HVBAT_CELL_22_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 23 voltage INFINITI_HVBAT_CELL_23_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 24 voltage INFINITI_HVBAT_CELL_24_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 25 voltage INFINITI_HVBAT_CELL_25_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 26 voltage INFINITI_HVBAT_CELL_26_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 27 voltage INFINITI_HVBAT_CELL_27_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 28 voltage INFINITI_HVBAT_CELL_28_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 29 voltage INFINITI_HVBAT_CELL_29_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 30 voltage INFINITI_HVBAT_CELL_30_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 31 voltage INFINITI_HVBAT_CELL_31_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 32 voltage INFINITI_HVBAT_CELL_32_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 33 voltage INFINITI_HVBAT_CELL_33_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 34 voltage INFINITI_HVBAT_CELL_34_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 35 voltage INFINITI_HVBAT_CELL_35_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 36 voltage INFINITI_HVBAT_CELL_36_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 37 voltage INFINITI_HVBAT_CELL_37_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 38 voltage INFINITI_HVBAT_CELL_38_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 39 voltage INFINITI_HVBAT_CELL_39_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 40 voltage INFINITI_HVBAT_CELL_40_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 41 voltage INFINITI_HVBAT_CELL_41_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 42 voltage INFINITI_HVBAT_CELL_42_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 43 voltage INFINITI_HVBAT_CELL_43_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 44 voltage INFINITI_HVBAT_CELL_44_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 45 voltage INFINITI_HVBAT_CELL_45_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 46 voltage INFINITI_HVBAT_CELL_46_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 47 voltage INFINITI_HVBAT_CELL_47_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 48 voltage INFINITI_HVBAT_CELL_48_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 49 voltage INFINITI_HVBAT_CELL_49_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 50 voltage INFINITI_HVBAT_CELL_50_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 51 voltage INFINITI_HVBAT_CELL_51_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 52 voltage INFINITI_HVBAT_CELL_52_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 53 voltage INFINITI_HVBAT_CELL_53_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 54 voltage INFINITI_HVBAT_CELL_54_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 55 voltage INFINITI_HVBAT_CELL_55_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 56 voltage INFINITI_HVBAT_CELL_56_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 57 voltage INFINITI_HVBAT_CELL_57_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 58 voltage INFINITI_HVBAT_CELL_58_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 59 voltage INFINITI_HVBAT_CELL_59_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 60 voltage INFINITI_HVBAT_CELL_60_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 61 voltage INFINITI_HVBAT_CELL_61_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 62 voltage INFINITI_HVBAT_CELL_62_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 63 voltage INFINITI_HVBAT_CELL_63_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 64 voltage INFINITI_HVBAT_CELL_64_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 65 voltage INFINITI_HVBAT_CELL_65_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 66 voltage INFINITI_HVBAT_CELL_66_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 67 voltage INFINITI_HVBAT_CELL_67_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 68 voltage INFINITI_HVBAT_CELL_68_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 69 voltage INFINITI_HVBAT_CELL_69_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 70 voltage INFINITI_HVBAT_CELL_70_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 71 voltage INFINITI_HVBAT_CELL_71_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 72 voltage INFINITI_HVBAT_CELL_72_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 73 voltage INFINITI_HVBAT_CELL_73_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 74 voltage INFINITI_HVBAT_CELL_74_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 75 voltage INFINITI_HVBAT_CELL_75_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 76 voltage INFINITI_HVBAT_CELL_76_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 77 voltage INFINITI_HVBAT_CELL_77_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 78 voltage INFINITI_HVBAT_CELL_78_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 79 voltage INFINITI_HVBAT_CELL_79_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 80 voltage INFINITI_HVBAT_CELL_80_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 81 voltage INFINITI_HVBAT_CELL_81_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 82 voltage INFINITI_HVBAT_CELL_82_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 83 voltage INFINITI_HVBAT_CELL_83_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 84 voltage INFINITI_HVBAT_CELL_84_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 85 voltage INFINITI_HVBAT_CELL_85_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 86 voltage INFINITI_HVBAT_CELL_86_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 87 voltage INFINITI_HVBAT_CELL_87_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 88 voltage INFINITI_HVBAT_CELL_88_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 89 voltage INFINITI_HVBAT_CELL_89_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 90 voltage INFINITI_HVBAT_CELL_90_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 91 voltage INFINITI_HVBAT_CELL_91_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 92 voltage INFINITI_HVBAT_CELL_92_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 93 voltage INFINITI_HVBAT_CELL_93_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 94 voltage INFINITI_HVBAT_CELL_94_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 95 voltage INFINITI_HVBAT_CELL_95_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

HV battery cell 96 voltage INFINITI_HVBAT_CELL_96_V_V2

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2003 to 2017.

Battery › Draw

Power used by air conditioning INFINITI_AC_PWR_EST

  • Request22 12 61
  • Service 22DID 1261
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 W
Unit
W

In testing for 2003 to 2017.

Power used by auxiliary equipment (lights, radio, navigation, rear defroster, etc...). INFINITI_AUX_PWR

  • Request22 11 52
  • Service 22DID 1152
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100)
Range
0 to 25500 W
Unit
W

In testing for 2003 to 2017.

Power used by both the A/C and PTC heater. INFINITI_AC_PWR

  • Request22 11 51
  • Service 22DID 1151
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 250)
Range
0 to 63750 W
Unit
W

In testing for 2003 to 2017.

Power used by cabin positive temperature coefficient (PTC) heaters. INFINITI_HTR_PWR

  • Request22 12 62
  • Service 22DID 1262
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 250)
Range
0 to 63750 W
Unit
W

In testing for 2003 to 2017.

Battery › Statistics

Quick charge count INFINITI_L1L2CHRG_CNT

Increments each time an L1/L2 charge occurs, even if only partially.

  • Request22 12 05
  • Service 22DID 1205
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2017.

Quick charge count INFINITI_QCKCHRG_CNT

Increments each time a quick charge occurs, even if only partially.

  • Request22 12 03
  • Service 22DID 1203
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2003 to 2017.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.