INFINITI QX70

Fuel parameters

The INFINITI QX70 has 7 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air/fuel ratio adjustment, bank 2 INFINITI_AF_ADJ_B2

  • Request22 11 24
  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 %
Unit
%

In testing for 2003 to 2017.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air/fuel ratio adjustment, bank 2 INFINITI_AF_ADJ_B2

  • Request22 11 24
  • Service 22DID 1124
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 100)
Range
-100 to 155 %
Unit
%

In testing for 2003 to 2017.

Fuel level input INFINITI_FLI_INPUT

  • Request22 11 14
  • Service 22DID 1114
  • ModuleDA18 → 18
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 25)
Range
0 to 10.2 V
Unit
V

In testing for 2003 to 2017.

Fuel pump flow INFINITI_FUEL_PMP_FLOW

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 8)
Range
0 to 31.87 g/s
Unit
g/s

In testing for 2003 to 2017.

Fuel rail temperature INFINITI_FUEL_RAIL_T

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2003 to 2017.

Fuel tank temperature INFINITI_FUEL_TANK_T

  • Request21 AD
  • Service 21PID AD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2003 to 2017.

Fuel temperature INFINITI_FUEL_T

  • Request22 11 11
  • Service 22DID 1111
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2003 to 2017.

Remaining fuel INFINITI_REMAINING_FUEL

  • Request22 11 86
  • Service 22DID 1186
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 L
Unit
L

In testing for 2003 to 2017.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.