Jeep Renegade

Transmission parameters

The Jeep Renegade has 10 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Automatic transmission temperature RENEGADE_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 1D 09
  • Service 22DID 1D09
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2014 to 2017, 2019 to 2020, 2022 to 2026. Not supported for 2018, 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Automatic transmission temperature RENEGADE_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 1D 09
  • Service 22DID 1D09
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2014 to 2017, 2019 to 2020, 2022 to 2026. Not supported for 2018, 2021.

Current gear RENEGADE_GEAR_CURRENTConfirmed

  • Request22 05 1A
  • Service 22DID 051A
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014, 2016 to 2017, 2022 to 2026

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2015, 2018 to 2021. In testing for 2014, 2016 to 2017, 2022 to 2023, 2025 to 2026. Not supported for 2024.

Desired gear RENEGADE_GEAR_DESIREDConfirmed

  • Request22 05 1A
  • Service 22DID 051A
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014, 2016 to 2017, 2022 to 2026

Bits 0 to 3 of the reply, 4 bits.

Formula
val
Range
0 to 15
Unit
Number

Confirmed for 2015, 2018 to 2021. In testing for 2014, 2016 to 2017, 2022 to 2023, 2025 to 2026. Not supported for 2024.

Gear RENEGADE_GEAR

  • Request22 1D 12
  • Service 22DID 1D12
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2014 to 2017, 2019 to 2020, 2022 to 2026. Not supported for 2018, 2021.

Gear engaged RENEGADE_GEAR_ECUConfirmed

  • Request22 19 2D
  • Service 22DID 192D
  • ModuleDA10 → 10
  • Every1 s
  • Testing for 2014 to 2017, 2022 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 9
Unit
Number

Confirmed for 2018 to 2021. In testing for 2014, 2016 to 2017, 2022 to 2026. Not supported for 2015.

Gearbox output speed RENEGADE_GEARBOX_RPMConfirmed

  • Request22 21 02
  • Service 22DID 2102
  • ModuleDA18 → 18
  • Every1 s
  • Testing for 2014, 2016 to 2017, 2022 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 rpm
Unit
rpm

Confirmed for 2015, 2018 to 2021. In testing for 2014, 2016 to 2017, 2022 to 2026.

TCM reported torque RENEGADE_TCM_TORQUEConfirmed

  • Request22 10 18
  • Service 22DID 1018
  • ModuleDA18 → 18
  • Every2 s
  • Testing for 2014, 2016 to 2017, 2022 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 500)
Range
-500 to 1000 N·m
Unit
N·m

Confirmed for 2015, 2018 to 2021. In testing for 2014, 2016 to 2017, 2022 to 2026.

Transmission fluid temperature RENEGADE_ATF_T_4THGENConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 04 FE
  • Service 22DID 04FE
  • ModuleDA18 → 18
  • Every5 s
  • Testing for 2014, 2016 to 2017, 2022 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015, 2018 to 2021. In testing for 2014, 2016 to 2017, 2022 to 2026.

Transmission input speed RENEGADE_AT_INPUT_RPM

  • Request22 1D 08
  • Service 22DID 1D08
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2014 to 2017, 2020, 2022 to 2026. Not supported for 2018 to 2019, 2021.

Transmission output speed RENEGADE_AT_OUTPUT_RPM

  • Request22 1D 07
  • Service 22DID 1D07
  • ModuleDA18
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2014 to 2017, 2020, 2022 to 2026. Not supported for 2018 to 2019, 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.