Kia Forte

Battery parameters

The Kia Forte has 24 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12 V battery state of charge FORTE_AUX_SOCConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2016, 2018 to 2019, 2021 to 2022

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2008 to 2016, 2018 to 2019, 2021 to 2022. Supported for 2017, 2020, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12 V battery state of charge FORTE_AUX_SOCConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2016, 2018 to 2019, 2021 to 2022

Bits 320 to 327 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2008 to 2016, 2018 to 2019, 2021 to 2022. Supported for 2017, 2020, 2024.

12 V battery state of health FORTE_AUX_SOHConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2008 to 2016, 2018 to 2019, 2021 to 2022

Bits 328 to 335 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 2008 to 2016, 2018 to 2019, 2021 to 2022. Supported for 2017, 2020, 2024.

12V battery charge FORTE_VPWR

  • Request22 E0 04
  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2008 to 2022, 2024

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2008 to 2009, 2011 to 2012, 2015. Supported for 2023. Not supported for 2010, 2013 to 2014, 2016 to 2022, 2024.

Battery capacity, battery sensor FORTE_BAT_CAP_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
val
Range
0 to 255 Ah
Unit
Ah

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery charge flag, battery sensor FORTE_BAT_CHG_FLAG_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 183 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery current FORTE_BAT_CURRENT

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The value is signed.

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7 A
Unit
A

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery current, battery sensor FORTE_BAT_CURRENT_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 A
Unit
A

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery health aging flag, battery sensor FORTE_BAT_HEALTH_AGING

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 182 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery is in use to crank the engine flag, battery sensor FORTE_BAT_CRANK_ENG_FLAG

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 181 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery quiescent current flag, battery sensor FORTE_BAT_QUIESCENT

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 180 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery sensor invalid condition flag, battery sensor FORTE_BATSENS_INVALID_COND

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 179 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery state of charge, battery sensor FORTE_BAT_ST_CHG_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery state of function, battery sensor FORTE_BAT_ST_FUNCTION

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val × 12.75 ÷ 255)
Range
0 to 12.75 V
Unit
V

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery state of health, battery sensor FORTE_BAT_ST_HEALTH

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery temperature FORTE_BAT_T

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5 °C
Unit
°C

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery temperature, battery sensor FORTE_BAT_T_BATSENS

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery voltage FORTE_BAT_V

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val × 10 ÷ 10000 + 6)
Range
0 to 71.535 V
Unit
V

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Battery voltage, battery sensor FORTE_BAT_V_BATSENS

Pelican can show this parameter as the starter battery voltage.

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 12.75 ÷ 255 + 6)
Range
0 to 18.75 V
Unit
V

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2010, 2017, 2019 to 2024. Supported for 2011 to 2014, 2016, 2018.

Relative accelerator pedal position voltage FORTE_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Response error from battery sensor flag, battery sensor FORTE_RESPONSE_ERROR

  • Request22 ED 27
  • Service 22DID ED27
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 178 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Throttle position sensor voltage #1 FORTE_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Throttle position sensor voltage #2 FORTE_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Wastegate position voltage FORTE_WASTEGATE_POS_V

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
-5.01 to 5.01 V
Unit
V

In testing for 2008 to 2022. Not supported for 2023 to 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.