DTC parameters
The Mazda MX-5 has 55 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2006 to 2007, 2009 to 2011, 2013 to 2017, 2019 to 2021, 2023 to 2026. Supported for 2018.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Request
01 21 - Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2011, 2014 to 2017, 2024 to 2025. Supported for 2006 to 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
DTC that caused required freeze frame data storage DTCFRZFSAE J1979Confirmed
0 indicates no freeze frame data.
- Request
01 02 - Service 01
PID 02 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Hexadecimal
Confirmed for 2016 to 2017, 2024 to 2025. Supported for 2015, 2018 to 2021, 2023, 2026.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
Pelican can show this parameter as the checkEngineLightOn.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Malfunction indicator lamp MX5_MIL_SWConfirmed
- Request
22 11 03 - Service 22
DID 1103 - Module
7E0 → 7E8 - Every
1 s - Testing for 1989 to 2005, 2008, 2012
Example reply from a 2015 Mazda MX-5.
Bit 2 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2006 to 2007, 2009 to 2011, 2013 to 2015. In testing for 1989 to 2001, 2003 to 2005, 2008, 2012. Not supported for 2002, 2016, 2019 to 2020.
Number of DTCs MX5_DTC_CNTConfirmed
- Request
22 02 00 - Service 22
DID 0200 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1989 to 2005, 2008, 2012
Example reply from a 2015 Mazda MX-5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2006 to 2007, 2009 to 2011, 2013 to 2015. In testing for 1989 to 2001, 2003 to 2005, 2008, 2012. Not supported for 2002, 2016, 2019 to 2020.
Number of DTCs (on demand) MX5_DTC_CNTDConfirmed
- Request
22 02 02 - Service 22
DID 0202 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1989 to 2005, 2008, 2012, 2017 to 2018, 2022
Example reply from a 2026 Mazda MX-5.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2006 to 2007, 2009 to 2011, 2013 to 2016, 2019 to 2021, 2023 to 2026. In testing for 1989 to 2001, 2003 to 2005, 2008, 2012, 2018, 2022. Not supported for 2002, 2017.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
Pelican can show this parameter as the storedDTCCount.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Request
01 30 - Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2011, 2014 to 2017, 2024 to 2025. Supported for 2006 to 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
DTCs › Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
DTCs › Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2016, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2017 to 2021, 2023, 2026.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2006, 2011, 2014 to 2017, 2024 to 2025. Supported for 2007, 2009 to 2010, 2013, 2018 to 2021, 2023, 2026.