Mazda RX-7

Climate parameters

The Mazda RX-7 has 25 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor current MAZDA_AC_COMP_A

  • Request22 99 AB
  • Service 22DID 99AB
  • Module7C7 → 7CF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 A
Unit
A

In testing for 1988 to 2002.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor current MAZDA_AC_COMP_A

  • Request22 99 AB
  • Service 22DID 99AB
  • Module7C7 → 7CF
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 A
Unit
A

In testing for 1988 to 2002.

A/C compressor pressure MAZDA_AC_P

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

In testing for 1988 to 2002.

A/C compressor pressure sensor voltage MAZDA_AC_P_SENS_V

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

In testing for 1988 to 2002.

A/C compressor, state MAZDA_AC_STATE

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2002.

A/C refrigerant pressure MAZDA_PCM_A_C_REFRIG_P

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

In testing for 1988 to 2002.

Ambient air temperature MAZDA_AAT

  • Request22 DD 05
  • Service 22DID DD05
  • Module723 → 72B
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2002.

Ambient temperature, alternate MAZDA_AAT_ALT

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 1988 to 2002.

Auxiliary water pump duty cycle MAZDA_AUXILIARY_WATER_PMP

  • Request22 43 36
  • Service 22DID 4336
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1988 to 2002.

Coolant heater operation mode MAZDA_COOLANT_HTR_OP_MODE

  • Request22 48 DF
  • Service 22DID 48DF
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2DEGRADEDDegraded
3SHUTDOWNShutdown
4SHORTShort
5NO_RESPONSENo response
6UNKNOWNUnknown
7STOPStop

In testing for 1988 to 2002.

Coolant heater power MAZDA_COOLANT_HTR_PWR

  • Request22 48 DE
  • Service 22DID 48DE
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 kW
Unit
kW

In testing for 1988 to 2002.

Evaporator temperature MAZDA_EVAPORATOR_T

  • Request22 98 4F
  • Service 22DID 984F
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 1988 to 2002.

Evaporator temperature v.2 MAZDA_EVAPORATOR_T_V_2

  • Request22 98 20
  • Service 22DID 9820
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 16 ÷ 5)
Range
-409 to 406 °C
Unit
°C

In testing for 1988 to 2002.

Exterior temperature MAZDA_AAT_V3

  • Request22 DD 05
  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2002.

Fuel-operated heater, inlet water temperature MAZDA_FOH_INLET_WATER_T

  • Request22 43 BE
  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2002.

Fuel-operated heater, outlet water temperature MAZDA_FOH_OUTLET_WATER_T

  • Request22 43 BE
  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2002.

Heat exchanger temperature MAZDA_HEAT_EXCHANGER_T

  • Request22 98 50
  • Service 22DID 9850
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 1988 to 2002.

Heat exchanger temperature v.2 MAZDA_HEAT_EXCHANGER_T_V_2

  • Request22 43 37
  • Service 22DID 4337
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 16 ÷ 5)
Range
-409 to 406 °C
Unit
°C

In testing for 1988 to 2002.

High-voltage coolant heater coolant inlet temperature MAZDA_HVCH_CLT_INLET_T

  • Request22 43 44
  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2002.

High-voltage coolant heater coolant outlet temperature MAZDA_HVCH_CLT_OUTLET_T

  • Request22 43 44
  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2002.

High-voltage coolant heater current consumption MAZDA_HVCH_CURRENT_CONS

  • Request22 43 45
  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 A
Unit
A

In testing for 1988 to 2002.

High-voltage coolant heater power consumption MAZDA_HVCH_POWER_CONS

  • Request22 43 45
  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 20)
Range
0 to 1310700 W
Unit
W

In testing for 1988 to 2002.

High-voltage coolant heater required power consumption MAZDA_HVCH_REQUIRED_POWER

  • Request22 43 45
  • Service 22DID 4345
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val × 20)
Range
0 to 1310700 W
Unit
W

In testing for 1988 to 2002.

Interior temperature MAZDA_IAT

  • Request22 DD 04
  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2002.

Interior temperature MAZDA_INTERIOR_T

  • Request22 98 43
  • Service 22DID 9843
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4 ÷ 5 − 60)
Range
-60 to 144 °C
Unit
°C

In testing for 1988 to 2002.

Motor internal temperature MAZDA_MOTOR_IAT

  • Request22 DD EF
  • Service 22DID DDEF
  • Module725 → 72D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 8)
Range
-4096 to 4095.875 °C
Unit
°C

In testing for 1988 to 2002.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.