Control parameters
The Mitsubishi RVR has 5 control parameters.
● Confirmed◆ In testing○ Supported× Not supported
Brake pedal MITSUBISHI_CVT_BRAKE
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Brake status MITSUBISHI_AWC_BRAKE_STS
- Request
21 0D - Service 21
PID 0D - Module
7B6 → 7B7 - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Brake switch MITSUBISHI_MPI_BRAKE_SWITCH
- Request
21 1D - Service 21
PID 1D - Module
7E0 - Every
250 ms - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Normal brake closed status MITSUBISHI_MPI_NORMAL_BRAKE_CLOSED_STS
- Request
21 1D - Service 21
PID 1D - Module
7E0 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Parking brake MITSUBISHI_AWC_PARKING_BRAKE
- Request
21 0D - Service 21
PID 0D - Module
7B6 → 7B7 - Every
250 ms - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.