Transmission parameters
The Mitsubishi RVR has 47 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Accelerator pedal MITSUBISHI_CVT_ACCELERATOR
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Anti-lock brake actuator signal MITSUBISHI_CVT_ABS_ACTUATOR_SIG
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Clutch 1 slip speed MITSUBISHI_CLUTCH_1_SLIP_AT_VSS
- Request
21 A6 - Service 21
PID A6 - Module
7E1 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 1991 to 2002, 2010 to 2024.
Clutch 1 temperature MITSUBISHI_CLUTCH_1_T
- Request
21 A5 - Service 21
PID A5 - Module
7E1 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 50)- Range
- -50 to 65485 °C
- Unit
- °C
In testing for 1991 to 2002, 2010 to 2024.
Clutch 2 temperature MITSUBISHI_CLUTCH_2_T
- Request
21 A5 - Service 21
PID A5 - Module
7E1 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val − 50)- Range
- -50 to 65485 °C
- Unit
- °C
In testing for 1991 to 2002, 2010 to 2024.
Current gear MITSUBISHI_AT_CUR_GEAR
- Request
21 04 - Service 21
PID 04 - Module
7E1 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.
Current gear ratio MITSUBISHI_CURRENT_GEAR_AT_RATIO
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.
Drive selected MITSUBISHI_CVT_SELECTOR_D
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Fluid degradation MITSUBISHI_CVT_OIL_DEGRADATION
Pelican can show this parameter as the CVT deterioration.
- Request
21 10 - Service 21
PID 10 - Module
7E1 - Every
3600 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.
Fluid degradation, output 3 MITSUBISHI_CVT_OUT3_OIL_DEGRADATION
- Request
21 10 - Service 21
PID 10 - Module
7E1 - Every
3600 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.
Gear MITSUBISHI_GEAR
- Request
22 15 0E - Service 22
DID 150E - Module
DA18 → 18 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.
Gear number MITSUBISHI_CVT_GEAR_AT_NUMBER
- Request
21 06 - Service 21
PID 06 - Module
7E1 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 1 to 256
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.
Input speed MITSUBISHI_INPUT_VSS
- Request
21 02 - Service 21
PID 02 - Module
7E1 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 1991 to 2002, 2010 to 2024.
Input torque MITSUBISHI_AT_INPUT_TORQUE
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
(val × 32 ÷ 5)- Range
- -819.2 to 812.8 N·m
- Unit
- N·m
In testing for 1991 to 2002, 2010 to 2024.
Line pressure MITSUBISHI_AT_LINE_PRES
- Request
21 04 - Service 21
PID 04 - Module
7E1 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 6.3 ÷ 255)- Range
- 0 to 6.3
- Unit
- Raw value
In testing for 1991 to 2002, 2010 to 2024.
Lock-up solenoid monitor current MITSUBISHI_CVT_LU_SOLENOID_MONITOR_MA
- Request
21 05 - Service 21
PID 05 - Module
7E1 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 1991 to 2002, 2010 to 2024.
Lock-up solenoid output current MITSUBISHI_CVT_LU_SOLENOID_OUTPUT_MA
- Request
21 05 - Service 21
PID 05 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 1991 to 2002, 2010 to 2024.
Lock-up/select changeover solenoid monitor MITSUBISHI_CVT_LU_SEL_CHANGEOVER_SOL_MONITOR
- Request
21 05 - Service 21
PID 05 - Module
7E1 - Every
1 s - Testing
Bit 115 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Lock-up/select changeover solenoid output MITSUBISHI_CVT_LU_SEL_CHANGEOVER_SOL_OUTPUT
- Request
21 05 - Service 21
PID 05 - Module
7E1 - Every
1 s - Testing
Bit 107 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Low selected MITSUBISHI_CVT_SELECTOR_L
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Neutral selected MITSUBISHI_CVT_SELECTOR_N
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Operating time MITSUBISHI_CVT_TOTAL_TIME
- Request
21 10 - Service 21
PID 10 - Module
7E1 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 6)- Range
- 0 to 10922.5
- Unit
- Raw value
In testing for 1991 to 2002, 2010 to 2024.
Output speed MITSUBISHI_OUTPUT_VSS
- Request
21 02 - Service 21
PID 02 - Module
7E1 - Every
250 ms - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 rpm
- Unit
- rpm
In testing for 1991 to 2002, 2010 to 2024.
Paddle shift mode MITSUBISHI_CVT_SELECTOR_DS_7E1_06
- Request
21 06 - Service 21
PID 06 - Module
7E1 - Every
250 ms - Testing
Bit 12 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Park selected MITSUBISHI_CVT_SELECTOR_P
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Primary pressure MITSUBISHI_PRIMARY_PRES
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 3.627392)- Range
- 0 to 924 psi
- Unit
- psi
In testing for 1991 to 2002, 2010 to 2024.
Primary pressure MITSUBISHI_PRIMARY_PRES_7E1_01
- Request
21 01 - Service 21
PID 01 - Module
7E1 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 1.332854 − 85.26)- Range
- -85.26 to 254 psi
- Unit
- psi
In testing for 1991 to 2002, 2010 to 2024.
Primary pulley speed MITSUBISHI_CVT_PRIMARY_VSS
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 32 − 64)- Range
- -64 to 8096 rpm
- Unit
- rpm
In testing for 1991 to 2002, 2010 to 2024.
Real engine torque MITSUBISHI_AT_REAL_ENGINE_TORQUE
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits. The value is signed.
- Formula
(val × 32 ÷ 5)- Range
- -819.2 to 812.8 N·m
- Unit
- N·m
In testing for 1991 to 2002, 2010 to 2024.
Reverse selected MITSUBISHI_CVT_SELECTOR_R
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Secondary pressure MITSUBISHI_SECONDARY_PRES
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 3.627392)- Range
- 0 to 924 psi
- Unit
- psi
In testing for 1991 to 2002, 2010 to 2024.
Secondary pulley speed MITSUBISHI_CVT_SECONDARY_VSS
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 64 − 128)- Range
- -128 to 16192 rpm
- Unit
- rpm
In testing for 1991 to 2002, 2010 to 2024.
Sleep revolution MITSUBISHI_AT_SLEEP_REVOLUTION
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 1991 to 2002, 2010 to 2024.
Slip speed MITSUBISHI_SLIP_AT_VSS
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 1991 to 2002, 2010 to 2024.
Slip speed MITSUBISHI_SLIP_AT_VSS_7E1_02
- Request
21 02 - Service 21
PID 02 - Module
7E1 - Every
250 ms - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 51)- Range
- -51 to 204 rpm
- Unit
- rpm
In testing for 1991 to 2002, 2010 to 2024.
Sport mode selected MITSUBISHI_CVT_SELECTOR_DS
- Request
21 06 - Service 21
PID 06 - Module
7E1 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Stability control actuator signal MITSUBISHI_CVT_ASC_ACTUATOR_SIG
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Target gear ratio MITSUBISHI_TARGET_GEAR_AT_RATIO
- Request
21 04 - Service 21
PID 04 - Module
7E1 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.
Torque ratio MITSUBISHI_AT_TORQUE_RATIO
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val × 3.98 ÷ 255)- Range
- 0 to 3.98
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.
Traction control actuator signal MITSUBISHI_CVT_TCL_ACTUATOR_SIG
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1991 to 2002, 2010 to 2024.
Transmission fluid temperature MITSUBISHI_AT_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 55)- Range
- -55 to 200 °C
- Unit
- °C
In testing for 1991 to 2002, 2010 to 2024.
Transmission fluid temperature MITSUBISHI_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 02 - Service 21
PID 02 - Module
7E1 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1991 to 2002, 2010 to 2024.
Transmission fluid temperature MITSUBISHI_ATF_T_DA18_2170
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 21 70 - Service 22
DID 2170 - Module
DA18 → 18 - Every
5 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1991 to 2002, 2010 to 2024.
Transmission fluid temperature, pan MITSUBISHI_ATF_T_PAN
- Request
22 15 0E - Service 22
DID 150E - Module
DA18 → 18 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1991 to 2002, 2010 to 2024.
Transmission fluid temperature, pipe MITSUBISHI_ATF_T_PIPE
- Request
22 15 0E - Service 22
DID 150E - Module
DA18 → 18 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1991 to 2002, 2010 to 2024.
Transmission temperature MITSUBISHI_T_M_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 33 - Service 21
PID 33 - Module
7E1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1991 to 2002, 2010 to 2024.
Transmission temperature sensor count MITSUBISHI_CVT_T_RAW
- Request
21 03 - Service 21
PID 03 - Module
7E1 - Every
250 ms - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1991 to 2002, 2010 to 2024.