Climate parameters
The Mitsubishi Triton has 30 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C compressor drive flag TRITON_AC_A_C_COMPRESSOR_DRIVE_FLAGConfirmed
- Request
21 70 - Service 21
PID 70 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bit 7 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
A/C compressor drive request TRITON_AC_A_C_COMPRESSOR_DRIVE_REQUESTConfirmed
- Request
21 23 - Service 21
PID 23 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bit 7 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Air conditioning switch TRITON_AC_SWITCHConfirmed
- Request
21 23 - Service 21
PID 23 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bit 6 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Air temperature sensor TRITON_AC_AIR_THERMO_SNSConfirmed
- Request
21 10 - Service 21
PID 10 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 4 − 16) = -16 °C
- Formula
(val ÷ 4 − 16)- Range
- -16 to 47.75 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Ambient air temperature TRITON_AC_AATConfirmed
- Request
21 11 - Service 21
PID 11 - Module
688 → 511 - Every
5 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2 − 40) = -40 °C
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Compressor ON/OFF count TRITON_AC_COMPRESSOR_ON_OFF_COUNTConfirmed
- Request
21 80 - Service 21
PID 80 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 24 to 47 of the reply, 24 bits.
0x04C015 = 311317 → 311,317
- Formula
val- Range
- 0 to 16777215
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Compressor work time TRITON_AC_COMPRESSOR_WORK_TIMEConfirmed
- Request
21 81 - Service 21
PID 81 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 128 to 151 of the reply, 24 bits.
0x06192C = 399660 → (399660 × 5) = 1,998,300
- Formula
(val × 5)- Range
- 0 to 83886075
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Conditioner work time TRITON_AC_CONDITIONER_WORK_TIMEConfirmed
- Request
21 81 - Service 21
PID 81 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 104 to 127 of the reply, 24 bits.
0x14C869 = 1362025 → (1362025 × 5) = 6,810,125
- Formula
(val × 5)- Range
- 0 to 83886075
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Corrected driver temperature setting TRITON_AC_DRIVER_T_CORRConfirmed
- Request
21 34 - Service 21
PID 34 - Module
688 → 511 - Every
5 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0 °C
- Formula
(val ÷ 2)- Range
- 0 to 50 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Corrected passenger temperature setting TRITON_AC_PASSENGER_T_CORRConfirmed
- Request
21 34 - Service 21
PID 34 - Module
688 → 511 - Every
5 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 24 to 31 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0 °C
- Formula
(val ÷ 2)- Range
- 0 to 50 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Driver side output speed TRITON_AC_OUTPUT_VSS_DRConfirmed
- Request
21 22 - Service 21
PID 22 - Module
688 → 511 - Every
5 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0
- Formula
(val ÷ 2)- Range
- 0 to 16
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Driver temperature setting TRITON_AC_DRIVER_TConfirmed
- Request
21 34 - Service 21
PID 34 - Module
688 → 511 - Every
5 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0 °C
- Formula
(val ÷ 2)- Range
- 0 to 50 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Engine coolant temperature TRITON_AC_ECTConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
21 10 - Service 21
PID 10 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 32 to 39 of the reply, 8 bits.
0x00 = 0 → (0 − 40) = -40 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Engine RPM TRITON_AC_RPMConfirmed
Pelican can show this parameter as the engine speed.
- Request
21 13 - Service 21
PID 13 - Module
688 → 511 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 8 to 23 of the reply, 16 bits.
0x0000 = 0 → 0 rpm
- Formula
val- Range
- 0 to 7000 rpm
- Unit
- rpm
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Fan M1 work time TRITON_AC_FAN_M1_WORK_TIMEConfirmed
- Request
21 83 - Service 21
PID 83 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 40 to 63 of the reply, 24 bits.
0x06E7F3 = 452595 → (452595 × 5) = 2,262,975
- Formula
(val × 5)- Range
- 0 to 83886075
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Fan M2 work time TRITON_AC_FAN_M2_WORK_TIMEConfirmed
- Request
21 83 - Service 21
PID 83 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 64 to 87 of the reply, 24 bits.
0x023BF7 = 146423 → (146423 × 5) = 732,115
- Formula
(val × 5)- Range
- 0 to 83886075
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Idle up request TRITON_AC_IDLE_UP_REQUESTConfirmed
- Request
21 23 - Service 21
PID 23 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → 0 rpm
- Formula
val- Range
- 0 to 255 rpm
- Unit
- rpm
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Interior temperature TRITON_AC_INTERIOR_TConfirmed
- Request
21 10 - Service 21
PID 10 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 4 − 16) = -16 °C
- Formula
(val ÷ 4 − 16)- Range
- -16 to 47.75 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Leak indicator TRITON_AC_LEAK_INDICATORConfirmed
- Request
21 32 - Service 21
PID 32 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bit 7 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Leak indicator at 20% TRITON_AC_LEAK_INDICATOR_20Confirmed
- Request
21 32 - Service 21
PID 32 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bit 5 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Max pressure TRITON_AC_MAX_PRESConfirmed
- Request
21 81 - Service 21
PID 81 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 96 to 103 of the reply, 8 bits.
0x00 = 0 → (0 × 3.3 ÷ 255) = 0
- Formula
(val × 3.3 ÷ 255)- Range
- 0 to 3.3
- Unit
- Raw value
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Output mode TRITON_AC_OUTPUT_MODEConfirmed
- Request
21 22 - Service 21
PID 22 - Module
688 → 511 - Every
5 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 16
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Passenger side output speed TRITON_AC_OUTPUT_VSS_ASConfirmed
- Request
21 22 - Service 21
PID 22 - Module
688 → 511 - Every
5 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0
- Formula
(val ÷ 2)- Range
- 0 to 16
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Passenger temperature setting TRITON_AC_PASSENGER_TConfirmed
- Request
21 34 - Service 21
PID 34 - Module
688 → 511 - Every
5 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0 °C
- Formula
(val ÷ 2)- Range
- 0 to 50 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Pressure TRITON_AC_PRESConfirmed
- Request
21 10 - Service 21
PID 10 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → (0 × 3.3 ÷ 255) = 0
- Formula
(val × 3.3 ÷ 255)- Range
- 0 to 3.3
- Unit
- Raw value
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Rear defogger ON/OFF count TRITON_AC_REAR_DEFOGGER_ON_OFF_COUNTConfirmed
- Request
21 80 - Service 21
PID 80 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 48 to 63 of the reply, 16 bits.
0x00A0 = 160 → 160
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Recirculation time TRITON_AC_RECIRCULATION_TIMEConfirmed
- Request
21 81 - Service 21
PID 81 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 176 to 191 of the reply, 16 bits.
0x0E67 = 3687 → (3687 × 5) = 18,435 min
- Formula
(val × 5)- Range
- 0 to 327675 min
- Unit
- min
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Solar sensor TRITON_AC_SOLAR_SNSConfirmed
- Request
21 10 - Service 21
PID 10 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 24 to 31 of the reply, 8 bits.
0x00 = 0 → (0 × 5.5 ÷ 255) = 0
- Formula
(val × 5.5 ÷ 255)- Range
- 0 to 5.5
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
System work time TRITON_AC_SYSTEM_WORK_TIMEConfirmed
- Request
21 80 - Service 21
PID 80 - Module
688 → 511 - Every
3600 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 0 to 23 of the reply, 24 bits.
0x17E278 = 1565304 → (1565304 × 5) = 7,826,520
- Formula
(val × 5)- Range
- 0 to 83886075
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Vehicle speed TRITON_AC_VSSConfirmed
Pelican can show this parameter as the speed.
- Request
21 13 - Service 21
PID 13 - Module
688 → 511 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 24 to 39 of the reply, 16 bits.
0x0000 = 0 → 0 km/h
- Formula
val- Range
- 0 to 250 km/h
- Unit
- km/h
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.