Mitsubishi Triton

Transmission parameters

The Mitsubishi Triton has 24 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Transmission fluid temperature TRITON_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 02
  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 40 to 47 of the reply, 8 bits.

0x4D = 77 → (77 − 40) = 37 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Accelerator pedal TRITON_CVT_ACCELERATORConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Anti-lock brake actuator signal TRITON_CVT_ABS_ACTUATOR_SIGConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 23 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Drive selected TRITON_CVT_SELECTOR_DConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 0 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Gear TRITON_GEAR

  • Request22 15 0E
  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2023 to 2026.

Gear number TRITON_CVT_GEAR_AT_NUMBERConfirmed

  • Request21 06
  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

0x01 = 1 → (1 + 1) = 2

Formula
(val + 1)
Range
1 to 256
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Input speed TRITON_INPUT_VSSConfirmed

  • Request21 02
  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 23 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 2) = 0 rpm

Formula
(val ÷ 2)
Range
0 to 32767.5 rpm
Unit
rpm

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Lock-up solenoid monitor current TRITON_CVT_LU_SOLENOID_MONITOR_MA

  • Request21 05
  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Bits 48 to 63 of the reply, 16 bits.

Formula
val
Range
0 to 65535 mA
Unit
mA

In testing for 1988 to 2017, 2019 to 2026.

Lock-up solenoid output current TRITON_CVT_LU_SOLENOID_OUTPUT_MAConfirmed

  • Request21 05
  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0 mA

Formula
val
Range
0 to 65535 mA
Unit
mA

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Lock-up/select changeover solenoid monitor TRITON_CVT_LU_SEL_CHANGEOVER_SOL_MONITOR

  • Request21 05
  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Bit 115 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2017, 2019 to 2026.

Lock-up/select changeover solenoid output TRITON_CVT_LU_SEL_CHANGEOVER_SOL_OUTPUT

  • Request21 05
  • Service 21PID 05
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Bit 107 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2017, 2019 to 2026.

Low selected TRITON_CVT_SELECTOR_LConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 5 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Neutral selected TRITON_CVT_SELECTOR_NConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 1 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Output speed TRITON_OUTPUT_VSSConfirmed

  • Request21 02
  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 39 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 2) = 0 rpm

Formula
(val ÷ 2)
Range
0 to 32767.5 rpm
Unit
rpm

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Paddle shift mode TRITON_CVT_SELECTOR_DS_7E1_06Confirmed

  • Request21 06
  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 12 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Park selected TRITON_CVT_SELECTOR_PConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 3 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Primary pressure TRITON_PRIMARY_PRES_7E1_01Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 1.332854 − 85.26)
Range
-85.26 to 254 psi
Unit
psi

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Reverse selected TRITON_CVT_SELECTOR_RConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 2 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Slip speed TRITON_SLIP_AT_VSS_7E1_02Confirmed

  • Request21 02
  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 64 to 71 of the reply, 8 bits.

0xFF = 255 → (255 − 51) = 204 rpm

Formula
(val − 51)
Range
-51 to 204 rpm
Unit
rpm

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Sport mode selected TRITON_CVT_SELECTOR_DSConfirmed

  • Request21 06
  • Service 21PID 06
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 3 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Stability control actuator signal TRITON_CVT_ASC_ACTUATOR_SIGConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 17 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Traction control actuator signal TRITON_CVT_TCL_ACTUATOR_SIGConfirmed

  • Request21 07
  • Service 21PID 07
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 19 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Transmission fluid temperature TRITON_ATF_TConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 02
  • Service 21PID 02
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 40 to 47 of the reply, 8 bits.

0x4D = 77 → (77 − 40) = 37 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Transmission fluid temperature, pan TRITON_ATF_T_PAN

  • Request22 15 0E
  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature, pipe TRITON_ATF_T_PIPE

  • Request22 15 0E
  • Service 22DID 150E
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2023 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.